945 resultados para pitch contour
Resumo:
High resolution digital elevation models (DEMs) of Santiaguito and Pacaya volcanoes, Guatemala, were used to estimate volume changes and eruption rates between 1954 and 2001. The DEMs were generated from contour maps and aerial photography, which were analyzed in ArcGIS 9.0®. Because both volcanoes were growing substantially over the five decade period, they provide a good data set for exploring effective methodology for estimating volume changes. The analysis shows that the Santiaguito dome complex grew by 0.78 ± 0.07 km3 (0.52 ± 0.05 m3 s-1) over the 1954-2001 period with nearly all the growth occurring on the El Brujo (1958-75) and Caliente domes (1971-2001). Adding information from field data prior to 1954, the total volume extruded from Santiaguito since 1922 is estimated at 1.48 ± 0.19 km3. Santiaguito’s growth rate is lower than most other volcanic domes, but it has been sustained over a much longer period and has undergone a change toward more exogenous and progressively slower extrusion with time. At Santiaguito some of the material being added at the dome is subsequently transported downstream by block and ash flows, mudflows and floods, creating channel shifting and areas of aggradation and erosion. At Pacaya volcano a total volume of 0.21 ± 0.05 km3 was erupted between 1961 and 2001 for an average extrusion rate of 0.17 ± 0.04 m3 s-1. Both the Santiaguito and Pacaya eruption rate estimates reported here are minima, because they do not include estimates of materials which are transported downslope after eruption and data on ashfall which may result in significant volumes of material spread over broad areas. Regular analysis of high resolution DEMs using the methods outlined here, would help quantify the effects of fluvial changes to downstream populated areas, as well as assist in tracking hazards related to dome collapse and eruption.
Resumo:
FEAST is a recently developed eigenvalue algorithm which computes selected interior eigenvalues of real symmetric matrices. It uses contour integral resolvent based projections. A weakness is that the existing algorithm relies on accurate reasoned estimates of the number of eigenvalues within the contour. Examining the singular values of the projections on moderately-sized, randomly-generated test problems motivates orthogonalization-based improvements to the algorithm. The singular value distributions provide experimentally robust estimates of the number of eigenvalues within the contour. The algorithm is modified to handle both Hermitian and general complex matrices. The original algorithm (based on circular contours and Gauss-Legendre quadrature) is extended to contours and quadrature schemes that are recursively subdividable. A general complex recursive algorithm is implemented on rectangular and diamond contours. The accuracy of different quadrature schemes for various contours is investigated.
Resumo:
Clinical assessments after Total Knee Arthroplasty (TKA) show persisting pain after implantation in over 20% of patients. Impingement of soft tissue around the knee, due to imprecise geometry of the tibial implant, can be one reason for persisting ailment. Two hundred and thirty seven MRI scans were evaluated using an active contour detection algorithm (snake) to obtain a high-resolution mean anatomical shape of the tibial plateau. Differences between female and male, older and younger (
Resumo:
Music plays an important role in the daily life of cochlear implant (CI) users, but electrical hearing and speech processing pose challenges for enjoying music. Studies of unilateral CI (UCI) users' music perception have found that these subjects have little difficulty recognizing tempo and rhythm but great difficulty with pitch, interval and melody. The present study is an initial step towards understanding music perception in bilateral CI (BCI) users. The Munich Music Questionnaire was used to investigate music listening habits and enjoyment in 23 BCI users compared to 2 control groups: 23 UCI users and 23 normal-hearing (NH) listeners. Bilateral users appeared to have a number of advantages over unilateral users, though their enjoyment of music did not reach the level of NH listeners.
Resumo:
RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.
Resumo:
In this paper we present a model-based approach for real-time camera pose estimation in industrial scenarios. The line model which is used for tracking is generated by rendering a polygonal model and extracting contours out of the rendered scene. By un-projecting a point on the contour with the depth value stored in the z-buffer, the 3D coordinates of the contour can be calculated. For establishing 2D/3D correspondences the 3D control points on the contour are projected into the image and a perpendicular search for gradient maxima for every point on the contour is performed. Multiple hypotheses of 2D image points corresponding to a 3D control point make the pose estimation robust against ambiguous edges in the image.
Resumo:
Dem Thema Baustellenlogistik wurde sowohl in der Baubranche selbst als auch in der Forschung in den letzten Jahren nur begrenzte Aufmerksamkeit gewidmet. Durch die Optimierung der baunahen Prozesse, wie beispielsweise Transport von Stück- und Schüttgütern, lassen sich noch weit reichende Einsparpotenziale realisieren. Im Rahmen eines AiF Forschungsprojektes wurde am Lehrstuhl für Fördertechnik Materialfluss Logistik (fml) der TU München in Zusammenarbeit mit Industriepartnern ein Flottentelematiksystem für die Baubranche unter Berücksichtigung der besonderen Randbedingungen, entwickelt und in einem langfristigen Pilotversuch getestet. Ein zentraler Bestandteil des Systems stellt die Anbindung an ein übergeordnetes Back Office System (SAP) dar, an das alle relevanten Informationen übermittelt werden und somit für die Abrechung und statistische Auswertungen zur Verfügung stehen.
Resumo:
During decades Distance Transforms have proven to be useful for many image processing applications, and more recently, they have started to be used in computer graphics environments. The goal of this paper is to propose a new technique based on Distance Transforms for detecting mesh elements which are close to the objects' external contour (from a given point of view), and using this information for weighting the approximation error which will be tolerated during the mesh simplification process. The obtained results are evaluated in two ways: visually and using an objective metric that measures the geometrical difference between two polygonal meshes.
Resumo:
In his compelling case study of local governance and community safety in the UK Thames Valley, Kevin Stenson makes several important contributions to the field of governmentality studies. While the paper’s merits are far-reaching, to this reader’s assessment they can be summarized in the following key areas: 1) Empirically, the article enhances our knowledge of the political economic transformation of a region otherwise overlooked in social science research ; 2) Conceptually, Stenson offers several theoretical and analytical refrains that, while becoming increasingly commonplace, are nonetheless still germane and rightly oriented to offer push back against otherwise totalizing, reified accounts of roll back/roll out neoliberalism. A welcomed new approach is offered as a corrective, The Realist Governmentality perspective, which emphasizes the interrelated and co-constitutive nature of politics, local culture, and habitus in processes related to the restructuring of social governance; 3) Methodologically, the paper makes a pitch for the ways in which finely grained, nuanced, mixed-method/ethnographic analyses have the potential to further problematize and recast a field of governmentality studies far too often dominated by discursive and textual approaches.
Resumo:
Dans le contexte global actuel, les autorités judiciaires ou administratives sont régulièrement confrontées à des situations présentant des éléments d'extranéité pour lesquelles un acte en dehors de la juridiction saisie est souvent nécessaire. Le principe de droit international public de territorialité délimite toutefois les pouvoirs étatiques; ces limites peuvent être surmontées par le recours aux mécanismes de l'entraide. Dans la pratique, le contour des limites territoriales des activités de l'Etat pose de nombreuses questions et crée autant d'incertitudes. Cet ouvrage veut donner une réponse à ces questions, notamment par une analyse approfondie de l'article 271 CP appliqué dans le cadre d’une procédure civile internationale. L'ouvrage présente et explique en outre le fonctionnement de l'entraide internationale en matière civile, en particuliers celui des Conventions de La Haye de 1965 et de 1970. Les auteurs développent également les fondements de l'entraide internationale civile en matière de notification et d'obtention de preuves. Il s'agit ainsi d'un ouvrage qui présente tant les aspects pratiques que les aspects théoriques de l'entraide et qui s'adresse aux praticiens - avocats ou juges -, aux universitaires et aux étudiants.
Resumo:
In this study, we compared direction detection thresholds of passive self-motion in the dark between artistic gymnasts and controls. Twenty-four professional female artistic gymnasts (ranging from 7 to 20 years) and age-matched controls were seated on a motion platform and asked to discriminate the direction of angular (yaw, pitch, roll) and linear (leftward–rightward) motion. Gymnasts showed lower thresholds for the linear leftward–rightward motion. Interestingly, there was no difference for the angular motions. These results show that the outstanding self-motion abilities in artistic gymnasts are not related to an overall higher sensitivity in self-motion perception. With respect to vestibular processing, our results suggest that gymnastic expertise is exclusively linked to superior interpretation of otolith signals when no change in canal signals is present. In addition, thresholds were overall lower for the older (14–20 years) than for the younger (7–13 years) participants, indicating the maturation of vestibular sensitivity from childhood to adolescence.
Resumo:
OBJECTIVES The purpose of this study was to assess the occurrence, predictors, and mechanisms of optical coherence tomography (OCT)-detected coronary evaginations following drug-eluting stent (DES) implantation. BACKGROUND Angiographic ectasias and aneurysms in stented segments have been associated with a risk of late stent thrombosis. Using OCT, some stented segments show coronary evaginations reminiscent of ectasias. METHODS Evaginations were defined as outward bulges in the luminal contour between struts. They were considered major evaginations (MEs) when extending ≥3 mm along the vessel length, with a depth ≥10% of the stent diameter. A total of 228 patients who had sirolimus (SES)-, paclitaxel-, biolimus-, everolimus (EES)-, or zotarolimus (ZES)-eluting stents implanted in 254 lesions, were analysed after 1, 2, or 5 years; and serial assessment using OCT and intravascular ultrasound (IVUS) was performed post-intervention and after 1 year in 42 patients. RESULTS Major evaginations occurred frequently at all time points in SES (∼26%) and were rarely seen in EES (3%) and ZES (2%, P = 0.003). Sirolimus-eluting stent implantation was the strongest independent predictor of ME [adjusted OR (95% CI) 9.1 (1.1-77.4), P = 0.008]. Malapposed and uncovered struts were more common in lesions with vs. without ME (77 vs. 25%, P < 0.001 and 95 vs. 20%, P < 0.001, respectively) as was thrombus [49 vs. 14%, OR 7.3 (95% CI: 1.7-31.2), P = 0.007]. Post-intervention intra-stent dissection and protrusion of the vessel wall into the lumen were associated with an increased risk of evagination at follow-up [OR (95% CI): 2.9 (1.8-4.9), P < 0.001 and 3.3 (1.6-6.9), P = 0.001, respectively]. In paired IVUS analyses, lesions with ME showed a larger increase in the external elastic membrane area (20% area change) compared with lesions without ME (5% area change, P < 0.001). CONCLUSION Optical coherence tomography-detected MEs are a specific morphological footprint of early-generation SES and are nearly absent in newer-generation ZES and EES. Evaginations appear to be related to vessel injury at baseline; are associated with positive vessel remodelling; and correlate with uncoverage, malapposition, and thrombus at follow-up.
Resumo:
Several strategies relying on kriging have recently been proposed for adaptively estimating contour lines and excursion sets of functions under severely limited evaluation budget. The recently released R package KrigInv 3 is presented and offers a sound implementation of various sampling criteria for those kinds of inverse problems. KrigInv is based on the DiceKriging package, and thus benefits from a number of options concerning the underlying kriging models. Six implemented sampling criteria are detailed in a tutorial and illustrated with graphical examples. Different functionalities of KrigInv are gradually explained. Additionally, two recently proposed criteria for batch-sequential inversion are presented, enabling advanced users to distribute function evaluations in parallel on clusters or clouds of machines. Finally, auxiliary problems are discussed. These include the fine tuning of numerical integration and optimization procedures used within the computation and the optimization of the considered criteria.
Resumo:
Impingement of the lesser trochanter on the ischium or the posterior acetabular rim is not a frequent pathology, but has recently received increased recognition. We have seen 14 cases over a period of 14 years, but concentrate on eight hips showing complex deformities revealing similar characteristics. All eight hips had a residual Perthes or a Perthes-like disease with an elliptically deformed femoral head, but a congurent joint a short or absent femoral neck, a high riding greater trochanter, and a reduced vertical distance between the head and the lesser trochanter. Impingement took place between the lesser trochanter and the ischium or the posteroinferior acetabular border, but was hardly recognisable due to the predominant intraarticular impingement of the nonspherical femoral head and the extraarticular impingement of the greater trochanter. In three cases the impingement showed reproducible subluxation of the hip. While in our hips, excision was the preferred treatment for impingement due to an oversized lesser trochanter, distal advancement was used in the hips with the Perthes morphology; the surgical time was not longer. The overall clinical results in this group however were dominated by a substantial increase in the range of motion (ROM), dependent mainly on the achieved contour of the femoral head and the relative lengthening of the neck. Strength of active hip flexion was normal. Recurrent subluxation disappeared and no complications were recorded.
Resumo:
Aims: Angiographic ectasias and aneurysms in stented segments have been associated with late stent thrombosis. Using optical coherence tomography (OCT), some stented segments show coronary evaginations reminiscent of ectasias. The purpose of this study was to explore, using computational fluid-dynamic (CFD) simulations, whether OCT-detected coronary evaginations can induce local changes in blood flow. Methods and results: OCT-detected evaginations are defined as outward bulges in the luminal vessel contour between struts, with the depth of the bulge exceeding the actual strut thickness. Evaginations can be characterised cross ectionally by depth and along the stented segment by total length. Assuming an ellipsoid shape, we modelled 3-D evaginations with different sizes by varying the depth from 0.2-1.0 mm, and the length from 1-9 mm. For the flow simulation we used average flow velocity data from non-diseased coronary arteries. The change in flow with varying evagination sizes was assessed using a particle tracing test where the particle transit time within the segment with evagination was compared with that of a control vessel. The presence of the evagination caused a delayed particle transit time which increased with the evagination size. The change in flow consisted locally of recirculation within the evagination, as well as flow deceleration due to a larger lumen - seen as a deflection of flow towards the evagination. Conclusions: CFD simulation of 3-D evaginations and blood flow suggests that evaginations affect flow locally, with a flow disturbance that increases with increasing evagination size.