999 resultados para parallel frequency converters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Even though frequency analysis of body sway is widely applied in clinical studies, the lack of standardized procedures concerning power spectrum estimation may provide unreliable descriptors. Stabilometric tests were applied to 35 subjects (20-51 years, 54-95 kg, 1.6-1.9 m) and the power spectral density function was estimated for the anterior-posterior center of pressure time series. The median frequency was compared between power spectra estimated according to signal partitioning, sampling rate, test duration, and detrending methods. The median frequency reliability for different test durations was assessed using the intraclass correlation coefficient. When increasing number of segments, shortening test duration or applying linear detrending, the median frequency values increased significantly up to 137%. Even the shortest test duration provided reliable estimates as observed with the intraclass coefficient (0.74-0.89 confidence interval for a single 20-s test). Clinical assessment of balance may benefit from a standardized protocol for center of pressure spectral analysis that provides an adequate relationship between resolution and variance. An algorithm to estimate center of pressure power density spectrum is also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the effect of the number of weekly repetitions of a static stretching program on the flexibility, hamstring tightness and electromyographic activity of the hamstring and of the triceps surae muscles. Thirty-one healthy subjects with hamstring tightness, defined as the inability to perform total knee extension, and shortened triceps surae, defined by a tibiotarsal angle wider than 90° during trunk flexion, were divided into three groups: G1 performed the stretching exercises once a week; G2, three times a week, and G3, five times a week. The parameters were determined before and after the stretching program. Flexibility improved in all groups after intervention, from 7.65 ± 10.38 to 3.67 ± 12.08 in G1, from 10.73 ± 12.07 to 0.77 ± 10.45 in G2, and from 14.20 ± 10.75 to 6.85 ± 12.19 cm in G3 (P < 0.05 for all comparisons). The increase in flexibility was higher in G2 than in G1 (P = 0.018), while G2 and G3 showed no significant difference (G1: 4 ± 2.17, G2: 10 ± 5.27; G3: 7.5 ± 4.77 cm). Hamstring tightness improved in all groups, from 37.90 ± 6.44 to 29 ± 11.65 in G1, from 39.82 ± 9.63 to 21.91 ± 8.40 in G2, and from 37.20 ± 6.63 to 26.10 ± 5.72° in G3 (P < 0.05 for all comparisons). During stretching, a statistically significant difference was observed in electromyographic activity of biceps femoris muscle between G1 and G3 (P = 0.048) and G2 and G3 (P = 0.0009). No significant differences were found in electromyographic activity during maximal isometric contraction. Stretching exercises performed three times a week were sufficient to improve flexibility and range of motion compared to subjects exercising once a week, with results similar to those of subjects who exercised five times a week.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nature and frequency of cystic fibrosis mutations in Brazil is not uniform due to the highly varied ethnic composition of the population. The average frequency of the F508del mutation has been reported to be 48.6%. Other common mutations in Brazil are G542X, R1162X, and N1303K. The aim of this study was to analyze the frequency of 8 mutations (F508del, G542X, R1162X, N1303K, W1282X, G85E, 3120+1G>A, and 711+1G>T) in a sample of 111 newborn patients with cystic fibrosis diagnosed by the Cystic Fibrosis Neonatal Screening Program of Minas Gerais State. The mutations were tested by allele-specific oligonucleotide PCR with specially designed primers. An allele frequency of 48.2% was observed for the F508del mutation, and allele frequencies of 5.41, 4.50, 4.05, and 3.60% were found for the R1162X, G542X, 3120+1G>A, and G85E mutations, respectively. The genotypes obtained were in Hardy-Weinberg equilibrium. These data demonstrate that the 8-mutation panel studied here has extensive coverage (68%) for the cystic fibrosis mutations in Minas Gerais. These data improve our knowledge of cystic fibrosis in Brazil, particularly in this region. In addition, this investigation contributed to the establishment of a sensitive and population-specific mutation panel, which can be helpful for molecular diagnosis of cystic fibrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to evaluate the characteristics of acute kidney injury (AKI) in AIDS patients and the value of RIFLE classification for predicting outcome. The study was conducted on AIDS patients admitted to an infectious diseases hospital inBrazil. The patients with AKI were classified according to the RIFLE classification: R (risk), I (injury), F (failure), L (loss), and E (end-stage renal disease). Univariate and multivariate analyses were used to evaluate the factors associated with AKI. A total of 532 patients with a mean age of 35 ± 8.5 years were included in this study. AKI was observed in 37% of the cases. Patients were classified as "R" (18%), "I" (7.7%) and "F" (11%). Independent risk factors for AKI were thrombocytopenia (OR = 2.9, 95%CI = 1.5-5.6, P < 0.001) and elevation of aspartate aminotransferase (AST) (OR = 3.5, 95%CI = 1.8-6.6, P < 0.001). General mortality was 25.7% and was higher among patients with AKI (40.2 vs17%, P < 0.001). AKI was associated with death and mortality increased according to RIFLE classification - "R" (OR 2.4), "I" (OR 3.0) and "F" (OR 5.1), P < 0.001. AKI is a frequent complication in AIDS patients, which is associated with increased mortality. RIFLE classification is an important indicator of poor outcome for AIDS patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most frequently reported Chinese renal biopsy data have originated from southeastern China. The present study analyzed the renal biopsy data from northeastern China. The records of 1550 consecutive native patients who were diagnosed with primary glomerular diseases (PGD) after renal biopsy at our hospital during 2005-2009 were used. These patients were divided into four age groups for stratified analysis: <15, 15-44, 45-59, and ≥60 years old. Among PGD, minimal change disease (MCD) was the most common histologically diagnosed disease (30.7%), followed by IgA nephropathy (IgAN), mesangial proliferative glomerulonephritis (MsPGN), membranous nephropathy (MN), membranoproliferative glomerulonephritis (MPGN), focal segmental glomerulosclerosis (FSGS), and endocapillary proliferative glomerulonephritis (EnPGN). MCD was the disease most frequently observed (43.7%) in the <15-year-old group. MsPGN was the most common disease in the elderly group (38.1%). MsPGN was more prevalent in females (27.8%), whereas MCD was more prevalent in males (35.3%). Primary glomerular diseases constituted the most commonly encountered group of diseases with a high prevalence of MCD, which predominantly affected males and young adults. The prevalence of MCD was high in northeastern China. Further study is necessary to expand the epidemiologic data available for renal disease in China.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to compare the effect of electroacupuncture (EA) and carprofen (CP) on postoperative incisional pain using the plantar incision (PI) model in rats. A 1-cm longitudinal incision was made through skin, fascia and muscles of a hind paw of male Wistar rats and the development of mechanical and thermal hypersensitivity was determined over 4 days using the von Frey and Hargreaves methods, respectively. Based on the experimental treatments received on the third postoperative day, the animals were divided into the following groups: PI+CP (CP, 2 mg/kg, po); PI+EAST36 (100-Hz EA applied bilaterally at the Zusanli point (ST36)); PI+EANP (EA applied to a non-acupoint region); PI+IMMO (immobilization only); PI (vehicle). In the von Frey test, the PI+EAST36 group had higher withdrawal force thresholds in response to mechanical stimuli than the PI, PI+IMMO and PI+EANP groups at several times studied. Furthermore, the PI+EAST36 group showed paw withdrawal thresholds in response to mechanical stimuli that were similar to those of the PI+CP group. In the Hargreaves test, all groups had latencies higher than those observed with PI. The PI+EAST36 group was similar to the PI+IMMO, PI+EANP and PI+CP groups. We conclude that 100-Hz EA at the ST36 point, but not at non-acupoints, can reduce mechanical nociception in the rat model of incisional pain, and its effectiveness is comparable to that of carprofen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serotonergic mechanisms have an important function in the central control of circulation. Here, the acute effects of three selective serotonin (5-HT) reuptake inhibitors (SSRIs) on autonomic and cardiorespiratory variables were measured in rats. Although SSRIs require 2-3 weeks to achieve their full antidepressant effects, it has been shown that they cause an immediate inhibition of 5-HT reuptake. Seventy male Wistar rats were anesthetized with urethane and instrumented to record blood pressure, heart rate, renal sympathetic nerve activity (RSNA), and respiratory frequency. At lower doses, the acute cardiovascular effects of fluoxetine, paroxetine and sertraline administered intravenously were insignificant and variable. At middle and higher doses, a general pattern was observed, with significant reductions in sympathetic nerve activity. At 10 min, fluoxetine (3 and 10 mg/kg) reduced RSNA by -33±4.7 and -31±5.4%, respectively, without changes in blood pressure; 3 and 10 mg/kg paroxetine reduced RSNA by -35±5.4 and -31±5.5%, respectively, with an increase in blood pressure +26.3±2.5; 3 mg/kg sertraline reduced RSNA by -59.4±8.6%, without changes in blood pressure. Sympathoinhibition began 5 min after injection and lasted approximately 30 min. For fluoxetine and sertraline, but not paroxetine, there was a reduction in heart rate that was nearly parallel to the sympathoinhibition. The effect of these drugs on the other variables was insignificant. In conclusion, acute peripheral administration of SSRIs caused early autonomic cardiovascular effects, particularly sympathoinhibition, as measured by RSNA. Although a peripheral action cannot be ruled out, such effects are presumably mostly central.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The CYP2D6 enzyme is crucial for the metabolism of tamoxifen. The CYP2D6 gene is highly polymorphic, and individuals can be extensive, intermediate, or poor tamoxifen metabolizers. The aim of this study was to determine the frequencies of the CYP2D6 *3, *4, and *10 alleles in women with breast cancer who were treated with tamoxifen and analyze the association of enzyme activity with prognostic factors and disease-free survival. We observed a high frequency of CYP2D6 *10, with an allelic frequency of 0.14 (14.4%). The *3 allele was not present in the studied population, and *4 had an allelic frequency of 0.13 (13.8%). We conclude that patients with reduced CYP2D6 activity did not present worse tumor characteristics or decreased disease-free survival than women with normal enzyme activity, as the difference was not statistically significant. We also observed a high frequency of CYP2D6 *10, which had not been previously described in this specific population. This study is the first in north-northeastern Brazil that aimed to contribute to the knowledge of the Brazilian regional profile for CYP2D6 polymorphisms and their phenotypes. These findings add to the knowledge of the distribution of different polymorphic CYP2D6 alleles and the potential role of CYP2D6 genotyping in clinical practice prior to choosing therapeutic protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myocardial ischemia, as well as the induction agents used in anesthesia, may cause corrected QT interval (QTc) prolongation. The objective of this randomized, double-blind trial was to determine the effects of high- vs conventional-dose bolus rocuronium on QTc duration and the incidence of dysrhythmias following anesthesia induction and intubation. Fifty patients about to undergo coronary artery surgery were randomly allocated to receive conventional-dose (0.6 mg/kg, group C, n=25) or high-dose (1.2 mg/kg, group H, n=25) rocuronium after induction with etomidate and fentanyl. QTc, heart rate, and mean arterial pressure were recorded before induction (T0), after induction (T1), after rocuronium (just before laryngoscopy; T2), 2 min after intubation (T3), and 5 min after intubation (T4). The occurrence of dysrhythmias was recorded. In both groups, QTc was significantly longer at T3 than at baseline [475 vs 429 ms in group C (P=0.001), and 459 vs 434 ms in group H (P=0.005)]. The incidence of dysrhythmias in group C (28%) and in group H (24%) was similar. The QTc after high-dose rocuronium was not significantly longer than after conventional-dose rocuronium in patients about to undergo coronary artery surgery who were induced with etomidate and fentanyl. In both groups, compared with baseline, QTc was most prolonged at 2 min after intubation, suggesting that QTc prolongation may be due to the nociceptive stimulus of intubation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neoadjuvant chemotherapy has practical and theoretical advantages over adjuvant chemotherapy strategy in breast cancer (BC) management. Moreover, metronomic delivery has a more favorable toxicity profile. The present study examined the feasibility of neoadjuvant metronomic chemotherapy in two cohorts [HER2+ (TraQme) and HER2− (TAME)] of locally advanced BC. Twenty patients were prospectively enrolled (TraQme, n=9; TAME, n=11). Both cohorts received weekly paclitaxel at 100 mg/m2 during 8 weeks followed by weekly doxorubicin at 24 mg/m2 for 9 weeks in combination with oral cyclophosphamide at 100 mg/day (fixed dose). The HER2+ cohort received weekly trastuzumab. The study was interrupted because of safety issues. Thirty-six percent of patients in the TAME cohort and all patients from the TraQme cohort had stage III BC. Of note, 33% from the TraQme cohort and 66% from the TAME cohort displayed hormone receptor positivity in tumor tissue. The pathological complete response rates were 55% and 18% among patients enrolled in the TraQme and TAME cohorts, respectively. Patients in the TraQme cohort had more advanced BC stages at diagnosis, higher-grade pathological classification, and more tumors lacking hormone receptor expression, compared to the TAME cohort. The toxicity profile was also different. Two patients in the TraQme cohort developed pneumonitis, and in the TAME cohort we observed more hematological toxicity and hand-foot syndrome. The neoadjuvant metronomic chemotherapy regimen evaluated in this trial was highly effective in achieving a tumor response, especially in the HER2+ cohort. Pneumonitis was a serious, unexpected adverse event observed in this group. Further larger and randomized trials are warranted to evaluate the association between metronomic chemotherapy and trastuzumab treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The levels of serum inflammatory cytokines and the activation of nuclear factor kappa B (NF-κB) and hypoxia inducible factor-1α (HIF-1α) in heart tissues in response to different frequencies of intermittent hypoxia (IH) and the antioxidant tempol were evaluated. Wistar rats (64 males, 200-220 g) were randomly divided into 6 experimental groups and 2 control groups. Four groups were exposed to IH 10, 20, 30, or 40 times/h. The other 2 experimental groups were challenged with IH (30 times/h) plus tempol, either beginning on day 0 (IH30T0) or on day 29 (IH30T29). After 6 weeks of challenge, serum levels of tumor necrosis factor (TNF)-α, intracellular adhesion molecule (ICAM)-1, and interleukin-10 were measured, and western blot analysis was used to detect NF-κB p65 and HIF-1α in myocardial tissues. Serum levels of TNF-α and ICAM-1 and myocardial expression of NF-κB p65 and HIF-1α were all significantly higher in IH rats than in controls (P<0.001). Increased IH frequency resulted in more significant changes. Administration of tempol in IH rats significantly reduced levels of TNF-α, ICAM-1, NF-κB and HIF-1α compared with the non-tempol-treated group (F=16.936, P<0.001). IH induced an inflammatory response in a frequency-dependent manner. Additionally, HIF-1α and NF-κB were increased following IH administration. Importantly, tempol treatment attenuated this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To deliver the energy saving potential, there is a need for easily implementable methods to monitor the system output. This is because information is needed to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable speed drives have proven to be able to give information on the system output without additional metering; however, the current model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The whole research of the current Master Thesis project is related to Big Data transfer over Parallel Data Link and my main objective is to assist the Saint-Petersburg National Research University ITMO research team to accomplish this project and apply Green IT methods for the data transfer system. The goal of the team is to transfer Big Data by using parallel data links with SDN Openflow approach. My task as a team member was to compare existing data transfer applications in case to verify which results the highest data transfer speed in which occasions and explain the reasons. In the context of this thesis work a comparison between 5 different utilities was done, which including Fast Data Transfer (FDT), BBCP, BBFTP, GridFTP, and FTS3. A number of scripts where developed which consist of creating random binary data to be incompressible to have fair comparison between utilities, execute the Utilities with specified parameters, create log files, results, system parameters, and plot graphs to compare the results. Transferring such an enormous variety of data can take a long time, and hence, the necessity appears to reduce the energy consumption to make them greener. In the context of Green IT approach, our team used Cloud Computing infrastructure called OpenStack. It’s more efficient to allocated specific amount of hardware resources to test different scenarios rather than using the whole resources from our testbed. Testing our implementation with OpenStack infrastructure results that the virtual channel does not consist of any traffic and we can achieve the highest possible throughput. After receiving the final results we are in place to identify which utilities produce faster data transfer in different scenarios with specific TCP parameters and we can use them in real network data links.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electric energy demand has been growing constantly as the global population increases. To avoid electric energy shortage, renewable energy sources and energy conservation are emphasized all over the world. The role of power electronics in energy saving and development of renewable energy systems is significant. Power electronics is applied in wind, solar, fuel cell, and micro turbine energy systems for the energy conversion and control. The use of power electronics introduces an energy saving potential in such applications as motors, lighting, home appliances, and consumer electronics. Despite the advantages of power converters, their penetration into the market requires that they have a set of characteristics such as high reliability and power density, cost effectiveness, and low weight, which are dictated by the emerging applications. In association with the increasing requirements, the design of the power converter is becoming more complicated, and thus, a multidisciplinary approach to the modelling of the converter is required. In this doctoral dissertation, methods and models are developed for the design of a multilevel power converter and the analysis of the related electromagnetic, thermal, and reliability issues. The focus is on the design of the main circuit. The electromagnetic model of the laminated busbar system and the IGBT modules is established with the aim of minimizing the stray inductance of the commutation loops that degrade the converter power capability. The circular busbar system is proposed to achieve equal current sharing among parallel-connected devices and implemented in the non-destructive test set-up. In addition to the electromagnetic model, a thermal model of the laminated busbar system is developed based on a lumped parameter thermal model. The temperature and temperature-dependent power losses of the busbars are estimated by the proposed algorithm. The Joule losses produced by non-sinusoidal currents flowing through the busbars in the converter are estimated taking into account the skin and proximity effects, which have a strong influence on the AC resistance of the busbars. The lifetime estimation algorithm was implemented to investigate the influence of the cooling solution on the reliability of the IGBT modules. As efficient cooling solutions have a low thermal inertia, they cause excessive temperature cycling of the IGBTs. Thus, a reliability analysis is required when selecting the cooling solutions for a particular application. The control of the cooling solution based on the use of a heat flux sensor is proposed to reduce the amplitude of the temperature cycles. The developed methods and models are verified experimentally by a laboratory prototype.