951 resultados para ocular ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes methods to circumvent the need to attach physical markers to bones for anatomical referencing in computer-assisted orthopedic surgery. Using ultrasound, a bone could be non-invasively referenced, and so the problem is formulated as the need for dynamic registration. A method for correspondence establishment is presented, and the matching step is based on three least-squares algorithms: two that are typically used in registration methods such as ICP, and the third is a form of the Unscented Kalman filter that was adapted to work in this context. A simulation was developed in order to reliably evaluate and compare the dynamic registration methods

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Pericard 6 (P6) is one of the most frequently used acupuncture points, especially in preventing nausea and vomiting. At this point, the median nerve is located very superficially. OBJECTIVES: To investigate the distance between the needle tip and the median nerve during acupuncture at P6, we conducted a prospective observational ultrasound (US) imaging study. We tested the hypothesis that de qi (a sensation that is typical of acupuncture needling) is evoked when the needle comes into contact with the epineural tissue and thereby prevents nerve penetration. SETTINGS/LOCATION: The outpatient pain clinic of the Medical University of Vienna, Austria. SUBJECTS: Fifty (50) patients receiving acupuncture treatment including P6 bilaterally. INTERVENTIONS: Patients were examined at both forearms using US (a 10-MHz linear transducer) after insertion of the needle at P6. OUTCOME MEASURES: The distance between the needle tip and the median nerve, the number of nerve contacts and nerve penetrations, as well as the number of successfully elicited de qi sensations were recorded. RESULTS: Complete data could be obtained from 97 cases. The mean distance from the needle tip to the nerve was 1.8 mm (standard deviation 2.2; range 0-11.3). Nerve contacts were recorded in 52 cases, in 14 of which the nerve was penetrated by the needle. De qi was elicited in 85 cases. We found no association between the number of nerve contacts and de qi. The 1-week follow-up showed no complications or neurologic problems. CONCLUSIONS: This is the first investigation demonstrating the relationship between acupuncture needle placement and adjacent neural structures using US technology. The rate of median nerve penetrations by the acupuncture needle at P6 was surprisingly high, but these seemed to carry no risk of neurologic sequelae. De qi at P6 does not depend on median nerve contact, nor does it prevent median nerve penetration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To analyze how far an ischemic component might have been involved in optic neuritis. METHODS: Case report: a 32-year-old man with symptoms characteristic for optic neuritis underwent extensive clinical, laboratory/serological and vascular examination for systemic associations and vascular involvement. RESULTS: The patient was found to have a temporary ocular blood flow dysregulation and increased plasma endothelin-1 levels which decreased after the acute phase of the optic nerve. CONCLUSIONS: We conclude that there might be an ischemic component in this patient with optic neuritis and hypothesize that this ischemic component is at least in part due to a temporarily increased endothelin-1 level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound (US) is an emerging imaging technique in interventional pain management. The main advantages are the identification of soft tissues, vessels, and nerves, without exposing patients and personnel to radiation, the possibility to perform continuous imaging, and the visualization of the fluid injected in a real-time fashion. Possible applications are nerve blocks of the cervical and lumbar zygapophysial joints, stellate ganglion block, intercostal nerve blocks, occipital nerve blocks, blocks of the inguinal nerves, peripheral nerve blocks of the extremities, blocks of painful stump neuromas, caudal epidural injections, and injections of tender points. US may also be used for destructive procedures, such as cryoanalgesia, radiofrequency lesions, or chemical neurolysis. The increasing published data available suggest that US has a potential usefulness in interventional pain management, but also limitations. There is still a need for clinical trials investigating efficacy and safety of US-guided pain procedures. Until these studies are made, fluoroscopy or computed tomography remain the gold standard for most interventional pain procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intermittent (IT) and continuous (CT) thermodilution and esophageal Doppler (ED), are all used for hemodynamic monitoring. The aim of this study was to test the agreement between these methods during endotoxin (ET) and dobutamine infusion. METHODS: Twenty-two pigs (39 +/- 1.8 kg body weight) were randomized to general anesthesia and either continuous ET (n = 9) or placebo (PL, n = 13) infusion. After 18 hours of ET or PL infusion, the animals were further randomized to receive dobutamine (n = 3 in ET, n = 5 in PL) or PL. A set of measurements using the three methods were obtained every hour, and the relative blood flow changes between two subsequent measurements were calculated. RESULTS: Bias or limits of agreement for flows were 0.73 L/min or 1.80 L/min for IT and CT, -0.33 L/min or 4.29 L/min for IT and ED, and -1.06 or 3.94 for CT and ED (n = 515, each). For flow changes they were 1% or 44%, 2% or 59%, and 3% or 45%, respectively. Bias and limits of agreement did not differ in ET- and PL-treated animals or in animals with or without dobutamine. Despite significant correlation between any two methods, the respective correlation coefficients (r) were small (IT vs. CT: 0.452; IT vs. ED: 0.042; CT vs. ED: 0.069; all p < 0.001). The same directional changes were measured by any two methods in 49%, 40%, and 50%. When IT flows >5 L/min were compared with IT flows 5 L/min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: /st> Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. METHODS: /st> In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. RESULTS: /st> The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. CONCLUSIONS: /st> Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To define the molecular pharmacology underlying the antiangiogenic effects of nonpeptide imidazolidine-2,4-dione somatostatin receptor agonists (NISAs) and evaluate the efficacy of NISA in ocular versus systemic delivery routes in ocular disease models. METHODS: Functional inhibitory effects of the NISAs and the somatostatin peptide analogue octreotide were evaluated in vitro by chemotaxis, proliferation, and tube-formation assays. The oxygen-induced retinopathy (OIR) model and the laser model of choroidal neovascularization (CNV) were used to test the in vivo efficacy of NISAs. Transscleral permeability of a candidate NISA was also measured. RESULTS: NISAs inhibited growth factor-induced HREC proliferation, migration and tube formation with submicromolar potencies (IC(50), 0.1-1.0 microM) comparable to octreotide. In the OIR model, systemic administration of the NISAs RFE-007 and RFE-011 inhibited retinal neovascularization in a dose-dependent manner, comparable to octreotide. In the CNV model, intravitreal RFE-011 resulted in a 56% reduction (P < 0.01) in CNV lesion area, whereas systemic administration resulted in a 35% reduction (P < 0.05) in lesion area. RFE-011 demonstrated transscleral penetration. CONCLUSIONS: Micromolar concentrations of octreotide and NISAs are necessary for antiangiogenic effects, whereas nanomolar concentrations are effective for endocrine inhibition. This suggests that the antiangiogenic activity of NISAs and octreotide is mediated by an overall much less efficient downstream coupling mechanism than is growth hormone release. As a result, the intravitreal or transscleral route of administration should be seriously considered for future clinical studies of SSTR2 agonists used for treatment of ocular neovascularization to ensure efficacious concentrations in the target retinal and choroidal tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. METHODS: We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. RESULTS: The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. CONCLUSIONS: We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural spaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an experiment on one of the authors, we used ultrasound to visualise an acupuncture needle completely perforating the median nerve at the acupuncture point PC6. During this procedure only a slight sensation occurred, and no pain. We conclude that, in individual cases, the median nerve might be perforated without causing pain or neurological problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D ultrasound can be used to study the fetal spine, but skeletal mode can be inconclusive for the diagnosis of fetal spina bifida. We illustrate a diagnostic approach using 2D and 3D ultrasound and indicate possible pitfalls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional (3D) ultrasound volume acquisition, analysis and display of fetal structures have enhanced their visualization and greatly improved the general understanding of their anatomy and pathology. The dynamic display of volume data generally depends on proprietary software, usually supplied with the ultrasound system, and on the operator's ability to maneuver the dataset digitally. We have used relatively simple tools and an established storage, display and manipulation format to generate non-linear virtual reality object movies of prenatal images (including moving sequences and 3D-rendered views) that can be navigated easily and interactively on any current computer. This approach permits a viewing or learning experience that is superior to watching a linear movie passively.