994 resultados para occupational medicine
Resumo:
OBJECTIVES: To review and update the evidence on predictors of poor outcome (death, persistent vegetative state or severe neurological disability) in adult comatose survivors of cardiac arrest, either treated or not treated with controlled temperature, to identify knowledge gaps and to suggest a reliable prognostication strategy. METHODS: GRADE-based systematic review followed by expert consensus achieved using Web-based Delphi methodology, conference calls and face-to-face meetings. Predictors based on clinical examination, electrophysiology, biomarkers and imaging were included. RESULTS AND CONCLUSIONS: Evidence from a total of 73 studies was reviewed. The quality of evidence was low or very low for almost all studies. In patients who are comatose with absent or extensor motor response at ≥72 h from arrest, either treated or not treated with controlled temperature, bilateral absence of either pupillary and corneal reflexes or N20 wave of short-latency somatosensory evoked potentials were identified as the most robust predictors. Early status myoclonus, elevated values of neuron-specific enolase at 48-72 h from arrest, unreactive malignant EEG patterns after rewarming, and presence of diffuse signs of postanoxic injury on either computed tomography or magnetic resonance imaging were identified as useful but less robust predictors. Prolonged observation and repeated assessments should be considered when results of initial assessment are inconclusive. Although no specific combination of predictors is sufficiently supported by available evidence, a multimodal prognostication approach is recommended in all patients.
Resumo:
Many interventions promoting physical activity (PA) are effective in preventing disease onset, and although studies have found a positive relationship between health-related quality of life (HRQL) and PA, most of these studies have focused on older adults and those with chronic conditions. Less is known regarding the association between PA level and HRQL among healthy adults. Our objective was to analyse the relationship between PA level and HRQL among a sample of 573 employees aged 20-68 taking part in a workplace intervention to promote PA. Measures included HRQL (using a single item) and PA (i.e. Godin Leisure-Time Questionnaire). The Modified Canadian Aerobic Fitness Test (MCAFT) was also completed by 10% of the employees. MET-minute scores (assessing energy expenditure over one week) were compared across HRQL categories using ANOVA. A multiple linear regression analysis was conducted to further examine the relationship between HRQL and PA, controlling for potential covariates. Participants in the higher health status categories were found to report higher levels of energy expenditure (one-way ANOVA, p < 0.001). In the multiple linear regression model, each unit increase in health status level translated in a mean increase of 356 MET-minutes in energy expenditure (p < 0.001). This single-item assessment of health status explained six percent of the variance in energy expenditure. The study concludes that higher energy expenditure through PA among an adult workplace population is positively associated with increased health status, and it also suggests that a single-item HRQL measure is suitable for community- and population-based studies, reducing response burden and research costs.
Resumo:
The activity of radiopharmaceuticals in nuclear medicine is measured before patient injection with radionuclide calibrators. In Switzerland, the general requirements for quality controls are defined in a federal ordinance and a directive of the Federal Office of Metrology (METAS) which require each instrument to be verified. A set of three gamma sources (Co-57, Cs-137 and Co-60) is used to verify the response of radionuclide calibrators in the gamma energy range of their use. A beta source, a mixture of (90)Sr and (90)Y in secular equilibrium, is used as well. Manufacturers are responsible for the calibration factors. The main goal of the study was to monitor the validity of the calibration factors by using two sources: a (90)Sr/(90)Y source and a (18)F source. The three types of commercial radionuclide calibrators tested do not have a calibration factor for the mixture but only for (90)Y. Activity measurements of a (90)Sr/(90)Y source with the (90)Y calibration factor are performed in order to correct for the extra-contribution of (90)Sr. The value of the correction factor was found to be 1.113 whereas Monte Carlo simulations of the radionuclide calibrators estimate the correction factor to be 1.117. Measurements with (18)F sources in a specific geometry are also performed. Since this radionuclide is widely used in Swiss hospitals equipped with PET and PET-CT, the metrology of the (18)F is very important. The (18)F response normalized to the (137)Cs response shows that the difference with a reference value does not exceed 3% for the three types of radionuclide calibrators.
Resumo:
Medicine counterfeiting is a crime that has increased in recent years and now involves the whole world. Health and economic repercussions have led pharmaceutical industries and agencies to develop many measures to protect genuine medicines and differentiate them from counterfeits. Detecting counterfeit is chemically relatively simple for the specialists, but much more information can be gained from the analyses in a forensic intelligence perspective. Analytical data can feed criminal investigation and law enforcement by detecting and understanding the criminal phenomenon. Profiling seizures using chemical and packaging data constitutes a strong way to detect organised production and industrialised forms of criminality, and is the focus of this paper. Thirty-three seizures of a commonly counterfeited type of capsule have been studied. The results of the packaging and chemical analyses were gathered within an organised database. Strong linkage was found between the seizures at the different production steps, indicating the presence of a main counterfeit network dominating the market. The interpretation of the links with circumstantial data provided information about the production and the distribution of counterfeits coming from this network. This forensic intelligence perspective has the potential to be generalised to other types of products. This may be the only reliable approach to help the understanding of the organised crime phenomenon behind counterfeiting and to enable efficient strategic and operational decision making in an attempt to dismantle counterfeit network.
Resumo:
Pollution of air, water and soil by industrial chemicals presents a potential health risk to humans. Such chemicals can enter the human body by three routes, namely by inhalation, dermal absorption, and ingestion and in special cases by injection (needle sticks, bites, cuts, etc.). In the workplace, pulmonary and dermal absorption are the main routes of entry, but poor personal hygiene and work habits can result in ingestion that contributes to the dose. Air monitoring provides reliable information on inhalation exposure, and patches can be used to estimate dermal exposure. Local adverse effects, such as skin and eye irritation, or nose and lung irritation, are closely related to the external exposure. Systemic adverse effects, on the other hand, are related to the absorbed amount (dose), or to the level of the pollutant or its metabolite in the target organ. Human biological monitoring is becoming a powerful tool for scientists and policy makers to assess and manage the risk of exposure to chemicals both in the general population and at the workpalce. This chapter will focus on the occupational environment keeping in mind that biological monitoring in humans is a very actual issue in public health politics, in environmental medicine, and in science in general.
Resumo:
Despite two international studies, there is still no consensus concerning prostate cancer screening. The results of a meta-analysis are making us question our convictions concerning pneumococcal vaccination. The preoperative work-up of cataract surgery can be simplified. When describing the efficacy of a treatment to a patient, relative risks are better understood than absolute risks. For rotator cuff syndrome, intramuscular corticosteroid injections are as efficient as intra-articular injections. In patients prescribed clopidogrel, a proton pump inhibitor is not absolutely necessary. The arrival of a anticoagulant that does not need blood monitoring is an interesting option in atrial fibrillation.
Resumo:
Recent findings suggest an association between exposure to cleaning products and respiratory dysfunctions including asthma. However, little information is available about quantitative airborne exposures of professional cleaners to volatile organic compounds deriving from cleaning products. During the first phases of the study, a systematic review of cleaning products was performed. Safety data sheets were reviewed to assess the most frequently added volatile organic compounds. It was found that professional cleaning products are complex mixtures of different components (compounds in cleaning products: 3.5 ± 2.8), and more than 130 chemical substances listed in the safety data sheets were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%), skin (50%) and by ingestion (60%) were the most reported. Monoethanolamine, a strong irritant and known to be involved in sensitizing mechanisms as well as allergic reactions, is frequently added to cleaning products. Monoethanolamine determination in air has traditionally been difficult and air sampling and analysis methods available were little adapted for personal occupational air concentration assessments. A convenient method was developed with air sampling on impregnated glass fiber filters followed by one step desorption, gas chromatography and nitrogen phosphorous selective detection. An exposure assessment was conducted in the cleaning sector, to determine airborne concentrations of monoethanolamine, glycol ethers, and benzyl alcohol during different cleaning tasks performed by professional cleaning workers in different companies, and to determine background air concentrations of formaldehyde, a known indoor air contaminant. The occupational exposure study was carried out in 12 cleaning companies, and personal air samples were collected for monoethanolamine (n=68), glycol ethers (n=79), benzyl alcohol (n=15) and formaldehyde (n=45). All but ethylene glycol mono-n-butyl ether air concentrations measured were far below (<1/10) of the Swiss eight hours occupational exposure limits, except for butoxypropanol and benzyl alcohol, where no occupational exposure limits were available. Although only detected once, ethylene glycol mono-n-butyl ether air concentrations (n=4) were high (49.5 mg/m3 to 58.7 mg/m3), hovering at the Swiss occupational exposure limit (49 mg/m3). Background air concentrations showed no presence of monoethanolamine, while the glycol ethers were often present, and formaldehyde was universally detected. Exposures were influenced by the amount of monoethanolamine in the cleaning product, cross ventilation and spraying. The collected data was used to test an already existing exposure modeling tool during the last phases of the study. The exposure estimation of the so called Bayesian tool converged with the measured range of exposure the more air concentrations of measured exposure were added. This was best described by an inverse 2nd order equation. The results suggest that the Bayesian tool is not adapted to predict low exposures. The Bayesian tool should be tested also with other datasets describing higher exposures. Low exposures to different chemical sensitizers and irritants should be further investigated to better understand the development of respiratory disorders in cleaning workers. Prevention measures should especially focus on incorrect use of cleaning products, to avoid high air concentrations at the exposure limits. - De récentes études montrent l'existence d'un lien entre l'exposition aux produits de nettoyages et les maladies respiratoires telles que l'asthme. En revanche, encore peu d'informations sont disponibles concernant la quantité d'exposition des professionnels du secteur du nettoyage aux composants organiques volatiles provenant des produits qu'ils utilisent. Pendant la première phase de cette étude, un recueil systématique des produits professionnels utilisés dans le secteur du nettoyage a été effectué. Les fiches de données de sécurité de ces produits ont ensuite été analysées, afin de répertorier les composés organiques volatiles les plus souvent utilisés. Il a été mis en évidence que les produits de nettoyage professionnels sont des mélanges complexes de composants chimiques (composants chimiques dans les produits de nettoyage : 3.5 ± 2.8). Ainsi, plus de 130 substances listées dans les fiches de données de sécurité ont été retrouvées dans les 105 produits répertoriés. Les principales classes de substances chimiques identifiées étaient les parfums, les éthers de glycol, les agents de surface et les solvants; dans une moindre mesure, les phosphates, les sels, les détergents, les régulateurs de pH, les acides et les bases ont été identifiés. Plus de 75% des produits répertoriés contenaient des substances décrites comme irritantes (Xi), 64% nuisibles (Xn) et 28% corrosives (C). Les risques pour les yeux (59%), la peau (50%) et par ingestion (60%) était les plus mentionnés. La monoéthanolamine, un fort irritant connu pour être impliqué dans les mécanismes de sensibilisation tels que les réactions allergiques, est fréquemment ajouté aux produits de nettoyage. L'analyse de la monoéthanolamine dans l'air a été habituellement difficile et les échantillons d'air ainsi que les méthodes d'analyse déjà disponibles étaient peu adaptées à l'évaluation de la concentration individuelle d'air aux postes de travail. Une nouvelle méthode plus efficace a donc été développée en captant les échantillons d'air sur des filtres de fibre de verre imprégnés, suivi par une étape de désorption, puis une Chromatographie des gaz et enfin une détection sélective des composants d'azote. Une évaluation de l'exposition des professionnels a été réalisée dans le secteur du nettoyage afin de déterminer la concentration atmosphérique en monoéthanolamine, en éthers de glycol et en alcool benzylique au cours des différentes tâches de nettoyage effectuées par les professionnels du nettoyage dans différentes entreprises, ainsi que pour déterminer les concentrations atmosphériques de fond en formaldéhyde, un polluant de l'air intérieur bien connu. L'étude de l'exposition professionnelle a été effectuée dans 12 compagnies de nettoyage et les échantillons d'air individuels ont été collectés pour l'éthanolamine (n=68), les éthers de glycol (n=79), l'alcool benzylique (n=15) et le formaldéhyde (n=45). Toutes les substances mesurées dans l'air, excepté le 2-butoxyéthanol, étaient en-dessous (<1/10) de la valeur moyenne d'exposition aux postes de travail en Suisse (8 heures), excepté pour le butoxypropanol et l'alcool benzylique, pour lesquels aucune valeur limite d'exposition n'était disponible. Bien que détecté qu'une seule fois, les concentrations d'air de 2-butoxyéthanol (n=4) étaient élevées (49,5 mg/m3 à 58,7 mg/m3), se situant au-dessus de la frontière des valeurs limites d'exposition aux postes de travail en Suisse (49 mg/m3). Les concentrations d'air de fond n'ont montré aucune présence de monoéthanolamine, alors que les éthers de glycol étaient souvent présents et les formaldéhydes quasiment toujours détectés. L'exposition des professionnels a été influencée par la quantité de monoéthanolamine présente dans les produits de nettoyage utilisés, par la ventilation extérieure et par l'emploie de sprays. Durant la dernière phase de l'étude, les informations collectées ont été utilisées pour tester un outil de modélisation de l'exposition déjà existant, l'outil de Bayesian. L'estimation de l'exposition de cet outil convergeait avec l'exposition mesurée. Cela a été le mieux décrit par une équation du second degré inversée. Les résultats suggèrent que l'outil de Bayesian n'est pas adapté pour mettre en évidence les taux d'expositions faibles. Cet outil devrait également être testé avec d'autres ensembles de données décrivant des taux d'expositions plus élevés. L'exposition répétée à des substances chimiques ayant des propriétés irritatives et sensibilisantes devrait être investiguée d'avantage, afin de mieux comprendre l'apparition de maladies respiratoires chez les professionnels du nettoyage. Des mesures de prévention devraient tout particulièrement être orientées sur l'utilisation correcte des produits de nettoyage, afin d'éviter les concentrations d'air élevées se situant à la valeur limite d'exposition acceptée.
Resumo:
Progress in genomics with, in particular, high throughput next generation sequencing is revolutionizing oncology. The impact of these techniques is seen on the one hand the identification of germline mutations that predispose to a given type of cancer, allowing for a personalized care of patients or healthy carriers and, on the other hand, the characterization of all acquired somatic mutation of the tumor cell, opening the door to personalized treatment targeting the driver oncogenes. In both cases, next generation sequencing techniques allow a global approach whereby the integrality of the genome mutations is analyzed and correlated with the clinical data. The benefits on the quality of care delivered to our patients are extremely impressive.
Resumo:
BACKGROUND: The goal of this paper is to investigate the respective influence of work characteristics, the effort-reward ratio, and overcommitment on the poor mental health of out-of-hospital care providers. METHODS: 333 out-of-hospital care providers answered a questionnaire that included queries on mental health (GHQ-12), demographics, health-related information and work characteristics, questions from the Effort-Reward Imbalance Questionnaire, and items about overcommitment. A two-level multiple regression was performed between mental health (the dependent variable) and the effort-reward ratio, the overcommitment score, weekly number of interventions, percentage of non-prehospital transport of patients out of total missions, gender, and age. Participants were first-level units, and ambulance services were second-level units. We also shadowed ambulance personnel for a total of 416 hr. RESULTS: With cutoff points of 2/3 and 3/4 positive answers on the GHQ-12, the percentages of potential cases with poor mental health were 20% and 15%, respectively. The effort-reward ratio was associated with poor mental health (P < 0.001), irrespective of age or gender. Overcommitment was associated with poor mental health; this association was stronger in women (β = 0.054) than in men (β = 0.020). The percentage of prehospital missions out of total missions was only associated with poor mental health at the individual level. CONCLUSIONS: Emergency medical services should pay attention to the way employees perceive their efforts and the rewarding aspects of their work: an imbalance of those aspects is associated with poor mental health. Low perceived esteem appeared particularly associated with poor mental health. This suggests that supervisors of emergency medical services should enhance the value of their employees' work. Employees with overcommitment should also receive appropriate consideration. Preventive measures should target individual perceptions of effort and reward in order to improve mental health in prehospital care providers.
Resumo:
The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, (99m)Tc- and (18)F-labelled radiopharmaceuticals for diagnostic and (90)Y-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure.
Resumo:
From our reading over the current year 2010 we have singled out 8 items which seem to us significant for the practice of medicine. Small doses of colchicine are useful in the treatment of gout. No efficacious treatment for muscular cramps can be recommended. A cervical collar can be usefully prescribed for the treatment of cervical radiculopathy. A single dose of azithromycin can be envisaged as a third line treatment of syphilis. High doses of vitamin D should not be prescribed for the prevention of fractures in elderly women because of the risks of falling. The wearing of bifocals can be associated with these risks. A clinical score is available to help with the diagnosis of thoracic pain. The NT-pro BNP is of limited use for the follow-up of patients suffering from heart failure.