998 resultados para maalaustaide - 1600-luku


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Particularly in elderly patients, the brain responds to a systemic inflammatory response with an increased production of inflammatory mediators. This has hypothetically been linked to the development of postoperative cognitive dysfunction (POCD). Methods: We investigated 31 patients aged >65 yrs undergoing elective major surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Cognitive function was measured preoperatively and 7 days postoperatively using the extended version of the Consortium to Establish a Registry for Alzheimer's Disease - Neuropsychological Assessment Battery (CERAD-NAB, validated German version) for which we developed a diagnostic cut-off in healthy elderly volunteers. Systemic C-reactive protein (CRP) and interleukin 6 (IL-6) were measured preoperatively, 2 days postoperatively, and 7 days postoperatively. Values for CRP, IL-6, operative characteristics and hospital length of stay in patients with POCD and without POCD were compared using the Mann- Whitney U test and are shown as median [range]. Results: Fourteen patients (45%) developed POCD. Values for CRP were not statistically different in patients with POCD and without POCD but tended to be higher in patients with POCD 2 days postoperatively. Patients with POCD had significantly higher IL-6 values on postoperative days 2 and 7 (table 1). These patients also had a significantly longer duration of anaesthesia (305 [195-620] vs.190 [150-560] min, p = 0.034), larger intraoperative blood loss (425 [0-1600] vs. 100 [0-1500] ml, p = 0.018) and longer hospital stays (15 [8-45] vs. 8 [4-40] days, p = 0.008). Table 1 POCD (n = 14) No POCD (n = 17) p value CRP (mg/dl) preop. 4.0 [1.0-245] 4.2 [0.3-36.2] 0.6 2 days postop. 223 [20-318] 98 [4.5-384] 0.07 7 days postop. 58 [15-147] 44 [11-148] 0.2 IL-6 (U/ml) preop. 2[2-28.1] 2 [2-7.3] 0.8 2 days postop. 56 [17-315] 20 [2-123] 0.009 7 days postop. 9[2-77] 4 [2-16] 0.03 Interpretation: In this small group of patients, high IL-6 values postoperatively were associated with POCD supporting a role for systemic inflammation in the development of POCD. In patients with POCD, duration of anaesthesia was significantly longer, and intraoperative blood losses were larger. These risk factors will need to be confirmed in a larger group of patients. The difference in length of stay may be indicative of postoperative complications, which have been linked to POCD earlier.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and sensitive liquid chromatography-electrospray ionization mass spectrometry method was developed for the simultaneous quantification in human plasma of all selective serotonin reuptake inhibitors (citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline) and their main active metabolites (desmethyl-citalopram and norfluoxetine). A stable isotope-labeled internal standard was used for each analyte to compensate for the global method variability, including extraction and ionization variations. After sample (250μl) pre-treatment with acetonitrile (500μl) to precipitate proteins, a fast solid-phase extraction procedure was performed using mixed mode Oasis MCX 96-well plate. Chromatographic separation was achieved in less than 9.0min on a XBridge C18 column (2.1×100mm; 3.5μm) using a gradient of ammonium acetate (pH 8.1; 50mM) and acetonitrile as mobile phase at a flow rate of 0.3ml/min. The method was fully validated according to Société Française des Sciences et Techniques Pharmaceutiques protocols and the latest Food and Drug Administration guidelines. Six point calibration curves were used to cover a large concentration range of 1-500ng/ml for citalopram, desmethyl-citalopram, paroxetine and sertraline, 1-1000ng/ml for fluoxetine and fluvoxamine, and 2-1000ng/ml for norfluoxetine. Good quantitative performances were achieved in terms of trueness (84.2-109.6%), repeatability (0.9-14.6%) and intermediate precision (1.8-18.0%) in the entire assay range including the lower limit of quantification. Internal standard-normalized matrix effects were lower than 13%. The accuracy profiles (total error) were mainly included in the acceptance limits of ±30% for biological samples. The method was successfully applied for routine therapeutic drug monitoring of more than 1600 patient plasma samples over 9 months. The β-expectation tolerance intervals determined during the validation phase were coherent with the results of quality control samples analyzed during routine use. This method is therefore precise and suitable both for therapeutic drug monitoring and pharmacokinetic studies in most clinical laboratories.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador: