970 resultados para interval of inseminations


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Osteosarcoma is the primary osseous neoplasia frequently diagnosed in dogs and it’s the main answerable for more than 85% of the neoplasias origened from the skeleton. The average age of onset of the lesion is 7 years, especially in large breeds and giant, with males being more affected than females. In general, 75% of osteosarcomas develop in the appendicular skeleton and 25% in the axial. The forelimbs are more affected than the hindlimbs, since support 60% of body weight. The osteosarcoma diagnosis is made by the analys of the animal’s clinic historic, detailed physique exams, blood exams alkaline phosphatase, xray exams, cytology, biopsy. The treatment of choice is the amputation associated to the chemotherapy. However, in some cases the member is preserved by the allograft technic. The chemotherapy associated to the surgery reduces the total load of the tumor, lengthens the interval of the life and improves the quality of pacient’s life. The most used medicines are cisplatin and doxorubicin. They can be used in separated or associated ways. The prognostic of dogs with osteosarcoma is reserved

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the recent years, the use of proton beams in radiotherapy has been an outstanding progress (SMITH, 2006). Up to now, computed tomography (CT) is a prerequisite for treatment planning in this kind of therapy because it provides the electron density distribution required for calculation of dose and the interval of doses. However, the use of CT images for proton treatment planning ignores fundamental differences in physical interaction processes between photons and protons and is, therefore, potentially inaccurate (SADROZINSKI, 2004). Proton CT (pCT) can in principle directly measure the density distribution needed in a patient for the dose distribution (SCHULTE, et al, 2004). One important problem that should be solved is the implementation of image reconstruction algorithms. In this sense, it is necessary to know how the presence of materials with different density and composition interfere in the energy deposition by ionization and coulomb excitation, during its trajectory. The study was conducted in two stages, was used in both the program SRIM (The Stopping and Range of Ions in Matter) to perform simulations of the interaction of proton beams with pencil beam type. In the first step we used the energies in the range of 100-250 MeV (ZIEGLER, 1999). The targets were set to 50 mm in length for the beam of 100 MeV, due to its interaction with the target, and short-range, and 70 mm for 150, 200 and 250 MeV The target was composed of liquid water and a layer of 6 mm cortical bone (ICRP). It were made 9 simulations varying the position of the heterogeneity of 5 mm. In the second step the energy of 250 MeV was taken out from the simulations, due to its greater energy and less interaction. The targets were diminished to 50 mm thick to standardize the simulations. The layer of bone was divided into two equal parts and both were put in the ends of the target... (Complete abstract click electronic access below)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Fisioterapia - FCT

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A study was conducted to determine the optimal time for collecting the breath examination urea breath marked with the stable isotope 13C. We selected patients before undergoing the examination of endoscopy at the Endoscopy Section of the University Hospital of Botucatu - SP. A screening was performed to determine which patients wanted and could participate. Before performing endoscopy basal sample was collected from the patient and then the labeled urea ingested. The blows were collected in double every 2.5 minutes until an interval of 30.0 minutes after were collected every 5.0 minutes until the time of 45.0 minutes . The samples were analyzed in a mass spectrometer for isotope ratio, located in the center of Stable Isotopes, Institute of Biosciences, UNESP - Botucatu campus. The data were studied and arranged in the form of graphics to better interpretation of results. Based on the obtained results it was determined that a standby time of 15.0 minutes to collect the wind is sufficient for accurate diagnosis and effective

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate the learning of Senior Citizens after a face-to-face course with the goal of teaching them how to use the internet. The study population was composed of people (n=18), of both genders, aged 50 years or over, from the open university for Senior Citizens UNATI (“Universidade Aberta da Terceira Idade” in Portuguese) at Araraquara. Two hour classes weekly were taught in the computer laboratory - LDI in Portuguese located in the School of Dentistry in Araraquara. The course program content covered the use of e-mail and researches in sites. In order to evaluate the learning acquired, a self-evaluation questionnaire was applied in twice (before and after the course), which enabled the development of students concerning their knowledge and skill in the topics approached in classes. Descriptive statistical analysis was performed. The average performance of participants was calculated per point and interval of confidence of 95% (IC95%) in the beginning and in the end of the course. Comparison between the averages was performed by using the paired Student’s-t test. The level of significance adopted was 5%. It was observed that the students’ learning about computer use improved significantly after the course (Student’s-t test: -5.360, p<0.001, p2=0.628, =0,999), however, 72.2% of them reported that they did not know how to attach a file to a message to be sent by e-mail, as well as having no or little skill to perform this activity. It was concluded that the evaluated course improved the participants knowledge and skills in computer use.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In laboratory tests, just following the manufacturer’s instructions of materials or equipments may not be enough to obtain reliable data. Thus, intra and inter-examiners studies may be required. The aim of this study was to illustrate the application of the Intraclass Correlation Coefficient (r) in a study related to the color changing and hardness of composite resin conducted by two examiners. The color and hardness of 10 specimens of composite resin were evaluated by a colorimetric spectrophotometer and hardness tester, respectively, at two different times. Two trained examiners performed two measurements with an interval of one week. Specimens were stored in artificial saliva at 37±1ºC for 7 days. The Intraclass Correlation was used for analysis of intra and inter-examiner reproducibility. The intra-examiner reproducibility was 0.79, 0.44 and 0.76 for L, a and b color coordinates for the examiner 1 and 0.84, 0.23, 0.21 for examiner 2. For hardness, r-values were 0.00 and 0.23 for the examiner 1 and 2, respectively, showing unsatisfactory agreement on color and hardness evaluation for both examiners. It was noted that only the observation of protocol for use of equipment and examiners training were not sufficient to collect reliable information. Thus, adjustments in the experimental protocol were made and devices were produced to standardize the measurements. The reproducibility study was performed again. For examiner 1, values as 0.90, 0.59 and 0.79 were verified for L, a and b coordinates and, for examiner 2 were obtained values of 0.90, 0.75, 0.95. In relation to hardness, r-values of 0.75 and 0.71 were obtained for examiners 1 and 2, respectively. The inter-examiner reproducibility was 0.86, 0.87, 0.91 for L, a and b coordinates and 0.79 for hardness. It was concluded that intra and inter-examiner calibration is essential for obtaining quality measurements in laboratory tests.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to estimate the reliability of the alcohol use disorders identification test (AUDIT) applied to adolescents. Evaluations were performed with 141 students of ages ranging from 14 to 17 years (14.93±0.62). The internal consistency of the instrument was estimated by Cronbach’s alpha coefficient and its reproducibility by weighted Kappa statistics by score and by a reliability interval of 95%. The AUDIT presented excellent internal consistency (α=0.80, rinter-item=0.29). Most questions present reproducibility ranked as “good”. It is concluded that the AUDIT is a reliable instrument to survey information about alcohol use in adolescents.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS