904 resultados para instrumentation for chemistry laboratories
Resumo:
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.
Resumo:
In this work, is discussed the importance of experimental activities in Education of Physics in Basic Education from the experience of Supervised Stage and the work with the Initiation of Teaching in the Program PIBID CAPES, in this case linked to the Department of Education of the Institute of Biosciences, Campus Rio Claro, São Paulo State, in partnership with three schools of basic education in the city. At first, based on the work of Ferreira with Instrumentation for Teaching Physics, consider the electrostatic theme. The focus is the searching for equipments constructed with low cost materials and easy access. Were developed and promoted strategies of the use of such materials in Physics’ Teaching, with a view to reintroducing experimental teaching activities in Public Basic Education, in the form Workshop Learning and Teaching of Physics, as well as lessons of Laboratory with the help of script and also in the form of an Experiments Library. These experimental activities were critically analyzed with a focus on playfulness. The focus of work in experimental activities for the Physics’ Teaching allowed to redeem, critically, didactic materials. From the standpoint of playfulness, playful moments and interaction of individuals with the knowledge that provides the experimental material when used strategically, they seem to be of great relevance to the Physics’ Teaching in Basic Education. It is possible to use experiments in Physics’ Teaching in public schools
Resumo:
This paper discuss possibilities of use of 3D animation as a tool for teaching Chemistry support. The research proposes to investigate the conception process and development of educational animations to use in a Blended Learning environment in undergraduate chemistry. Associated with general chemistry teachers, were raised the demands and difficulties on the content transmission, and the most relevant topics, about "Atomic Theory" with propose to create appropriate animations to meeting needs of themes. Thinking about offering more dynamic materials, we elaborate animations in a format of "micro-documentary", with a length between 4 and 7 minutes. We use the narration aloud to the subject-matter understanding, leaving the external text as a complement of the animation. The conclusions are positives, students accepted well the format and they proved are able to remember, organize and systematize several information presented in animations. These skills don't ensure knowledge acquisition, but may be considered prerequisites to learning occur.
Resumo:
The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.
Resumo:
To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. Material and methods Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal–Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. Results Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. Conclusions Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to assess the cleaning capacity of the Protaper system using motor-driven or manual instrumentation. Materials and Methods: Ten mandibular molars were randomly separated into 2 groups (n = 5) according to the type of instrumentation performed, as follows: Group 1 - instrumentation with rotary nickel-titanium (Ni-Ti) files using ProTaper Universal System (Dentsply/Maillefer); and, Group 2 - instrumentation with Ni-Ti hand files using ProTaper Universal (Dentsply-Maillefer). Afterwards, the teeth were sectioned transversely and submitted to histotechnical processing to obtain histological sections for microscopic evaluation. The images were analyzed by the Corel Photo-Paint X5 program (Corel Corporation) using an integration grid superimposed on the image. Results: Statistical analysis (U-Mann-Whitney - P < 0.05) demonstrated that G1 presented higher cleaning capacity when compared to G2. Conclusions: The rotary technique presented better cleaning results in the apical third of the root canal system when compared to the manual technique.
Resumo:
This paper describes the importance of an innovative analytical technique for drugs and pharmaceuticals quantification, using Fouriertransform infrared (FTIR) transmission spectroscopy. This method does not use organic solvents, which is one great advantage over the most common analytical methods. This fact contributes to minimize the generation of organic solvent waste by the industry and thereby reduces the impact of its activities on the environment. The method involved absorbance measurements of the band corresponding to one of the chosen group in the molecule. Obviously, the method should be validated according to ICH guidelines, showing linearity, precision, accuracy and robustness, over a concentration range, using small amounts to prepare the analyte. The validated method is able to quantify drugs and pharmaceuticals and can be used as an environmentally friendly alternative for the routine analysis in pharmaceutical industry quality control.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper refers to the design of an expert system that captures a waveform through the use of an accelerometer, processes the signal and converts it to the frequency domain using a Fast Fourier Transformer to then, using artificial intelligence techniques, specifically Fuzzy Reasoning, it determines if there is any failure present in the underlying mode of the equipment, such as imbalance, misalignment or bearing defects.
Resumo:
Brazil has a long tradition in the study of medicinal plants. When the Portuguese arrived to the new colony, Pero Vaz de Caminha, the scriber of the fleet, left the first impressions of the local and the inhabitants. He clearly mentions how the Indians use natural dye as tincture to paint their bodies. This article reviews the phytochemical and pharmacological characteristics of these colorants and other medicinal plants recently identified mentioned in this letter.