890 resultados para guided-wave optics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new device was developed to hold linear transducers for transvaginal follicle aspiration. Efficacy of follicle aspiration was compared using a linear 6 MHz and a convex 5 MHz transducer. Fifty-five cows were submitted to follicle aspiration at random days of the estrous cycle. Aspirations were conducted with linear (n = 28) and convex (n = 38) transducers with 18 G needles at a negative pressure corresponding to 13 ml H2O/min. A greater number of follicles were aspirated using convex than to linear probe (12.4 versus 7.8, respectively, P < 0.05). Mean number of oocytes and recovery rates were similar for convex (5.4 and 48.6%) and linear (4.6 and 59.3%) transducers. Limited space between the linear transducer and needle guide restricted access to some portions of the ovary, reducing the number of follicles aspirated using a linear transducer. The newly developed adaptor allowed greater stability, holding the ovaries firmly against the linear transducer. This diminished mobility permitted a similar number of oocytes to be recovered with both transducers. In conclusion, this new adaptor provided a low cost alternative for routine follicle aspiration and oocyte recovery in cattle. (C) 2002 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the relationship between follicle size and oocyte recovery (OR) using ultrasound-guided follicle aspiration. Thirty Holstein cows were subjected to OR without gonadotrophic therapy. Oocytes were recovered two to four times from each cow in a total of 67 aspiration sessions, Ovarian follicles with diameters less than or equal to4 mm and >4 mm were aspirated in separated groups. Recovered oocytes from each group were kept separate and submitted to in vitro maturation, fertilization, and culture to the blastocyst stage. A total of 430 follicles were aspirated, of which 154 (35.8%) were from follicles >4 mm and 276 (64.2%) were from follicles less than or equal to4 mm. Seventy-seven oocytes (50%) were recovered from follicles >4 mm and 200 (72.2%) were from follicles less than or equal to4 mm. Nineteen blastocysts were obtained from follicles >4 mm, whereas 45 blastocysts were obtained from follicles less than or equal to4 mm. Recovery rate was greater (P < 0.01) in follicles less than or equal to4 mm, Oocyte quality, cleavage rate and blastocyst development did not differ between different follicle sizes. Routine aspiration of small follicles (less than or equal to4 mm) could increase the number of oocytes available for in vitro development. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The applicability of plasma shock wave for material processing was investigated using modified inverse Z-pinch device. Shock wave expanding speed and plasma spectral analysis were studied using an internal magnetic,probe and spatially collimated light spectroscopy. The material processing capability of the device was shown by many different surface analysis techniques such as AES, IRS, EPM and SEM. The interactions between a plasma shock wave of similar to4x10(6) cm/s speed with a Si substrate surface shows some ion implantation capability using a nitrogen plasma and thin film formation using a methane plasma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a cell to measure dynamic viscosity of liquids using ultrasonic wave mode conversion from longitudinal to shear wave. The strategy used to obtain the viscosity is based on the measurement of the complex reflection coefficient of shear waves at a solid-liquid interface. Viscosity measurements of automotive oils (SAE90 and SAE140) were obtained in the frequency range from 1 to 10 MHz. These results are compared with the Maxwell model with two relaxation times, showing the dependency of viscosity with frequency. Several parameters affecting viscosity measurements, including the solid material properties, liquid viscosity, and operating frequency are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental technique for structural health monitoring (SHM) based on Lamb waves approach in an aluminum plate using piezoelectric material as actuators and sensors. Lamb waves are a form of elastic perturbation that remains guided between two parallel free surfaces, such as the upper and lower surfaces of a plate, beam or shelf. Lamb waves are formed when the actuator excites the surface of the structure with a pulse after receiving a signal. Two PZTs were placed in the plate surface and one of them was used to send a predefined wave through the structure. Thus, the other PZT (adjacent) becomes the sensor. Using this methodology, this paper presents one case of damage detection considering the aluminum plate in the free-free-free-free boundary condition. The damage was simulated by adding additional mass on the plate. It is proposed two damage detection indexes obtained from the experimental signal, involving the Fast Fourier Transform (FFT) and the power spectral density (PSD) that were computed using the output signal. The results show the viability of the presented methodology to damage detection in smart structures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we study the existence of shock wave solutions for systems of partial differential equations of hydrodynamics with viscosity in one space dimension in the context of Colombeau's theory of generalized functions. This study uses the equality in the strict sense and the association of generalized functions (that is the weak equality). The shock wave solutions are given in terms of generalized functions that have the classical Heaviside step function as macroscopic aspect. This means that solutions are sought in the form of sequences of regularizations to the Heaviside function that have to satisfy part of the equations in the strict sense and part of the equations in the sense of association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A biópsia da próstata não é um procedimento isento de riscos. Existe preocupação com respeito às complicações e quais seriam os melhores antibióticos usados antes do procedimento. O objetivo foi determinar a taxa de complicações e os possíveis fatores de risco para complicação na biópsia da próstata. TIPO DE ESTUDO E LOCAL: Estudo prospectivo clínico, realizado no Hospital das Clínicas de Botucatu. MÉTODOS: Foram realizadas biópsias em 174 pacientes que apresentavam anormalidade ao exame digital da próstata ou antígeno prostático específico maior que 4 ng/ml ou ambos. Todos os pacientes realizaram enema e antibioticoprofilaxia previamente ao exame. As complicações foram anotadas após o término do procedimento e em consultas posteriores. Algumas condições foram investigadas como possíveis fatores de risco para biópsias de próstata: idade, câncer da próstata, diabetes melito, hipertensão arterial sistêmica, antecedentes de prostatite, uso de ácido acetilsalicílico, volume prostático, número de biópsias e uso de sonda vesical. RESULTADOS: As complicações hemorrágicas foram mais comuns (75,3%) enquanto que as infecciosas ocorreram em 19% dos casos. O tipo mais freqüente foi a hematúria, ocorrendo em 56% dos pacientes. A infecção do trato urinário ocorreu em 16 pacientes (9,2%). Sepse foi observada em três pacientes (1,7%). Não houve óbitos. em 20% dos pacientes não foram observadas complicações após o exame. A presença da sonda vesical foi fator de risco para complicações infecciosas (p < 0,05). O número maior de amostras nas biópsias foi relacionado à hematúria, sangramento retal e complicações infecciosas (p < 0,05). As demais condições investigadas não se relacionaram com complicações pós-biópsia da próstata. CONCLUSÕES: As complicações pós-biópsia da próstata foram em sua maioria autolimitadas. A taxa de complicações graves foi baixa, sendo a biópsia de próstata guiada pelo ultra-som segura e eficaz. A retirada de um maior número de fragmentos na biópsia relaciona-se com hematúria, sangramento retal e complicações infecciosas. A sonda vesical foi um fator de risco para complicações infecciosas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Barrier materials as cellulose membranes are used for guided tissue repair. However, it is essential that the surrounding tissues accept the device. The present study histologically evaluated tissue reaction to a microbial cellulose membrane after subcutaneous implantation in mice. Furthermore, the interaction between mesenchymal stem cells and the biomaterial was studied in vitro to evaluate its ability to act as cellular scaffold for tissue engineering.Methods: Twenty-five Swiss Albino mice were used. A 10 x 10 mm cellulose membrane obtained through biosynthesis using Acetobacter xylinum bacteria was implanted into the lumbar subcutaneous tissue of each mouse. The mice were euthanatized at seven, 15, 30, 60, and 90 days, and the membrane and surrounding tissues were collected and examined by histology.Results: A mild inflammatory response without foreign body reaction was observed until 30 days post-surgery around the implanted membrane. Polarized microscopy revealed that the membrane remained intact at all evaluation points. Scanning electron microscopy of the cellulose membrane surface showed absence of pores. The in vitro evaluation of the interaction between cells and biomaterial was performed through viability staining analysis of the cells over the biomaterial, which showed that 95% of the mesenchymal stem cells aggregating to the cellulose membrane were alive and that 5% were necrotic. Scanning electron microscopy showed mesenchymal stem cells with normal morphology and attached to the cellulose membrane surface.Conclusion: The microbial cellulose membrane evaluated was found to be nonresorbable, induced a mild inflammatory response and may prove useful as a scaffold for mesenchymal stem cells.