984 resultados para group speaking tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a layered Smart Grid architecture enhancing security and reliability, having the ability to act in order to maintain and correct infrastructure components without affecting the client service. The architecture presented is based in the core of well design software engineering, standing upon standards developed over the years. The layered Smart Grid offers a base tool to ease new standards and energy policies implementation. The ZigBee technology implementation test methodology for the Smart Grid is presented, and provides field tests using ZigBee technology to control the new Smart Grid architecture approach. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the effectiveness of two speech therapy interventions, vocal warm-up and breathing training, focusing on teachers’ voice quality.METHODS A single-blind, randomized, parallel clinical trial was conducted. The research included 31 20 to 60-year old teachers from a public school in Salvador, BA, Northeasatern Brazil, with minimum workloads of 20 hours a week, who have or have not reported having vocal alterations. The exclusion criteria were the following: being a smoker, excessive alcohol consumption, receiving additional speech therapy assistance while taking part in the study, being affected by upper respiratory tract infections, professional use of the voice in another activity, neurological disorders, and history of cardiopulmonary pathologies. The subjects were distributed through simple randomization in groups vocal warm-up (n = 14) and breathing training (n = 17). The teachers’ voice quality was subjectively evaluated through the Voice Handicap Index (Índice de Desvantagem Vocal, in the Brazilian version) and computerized voice analysis (average fundamental frequency, jitter, shimmer, noise, and glottal-to-noise excitation ratio) by speech therapists.RESULTS Before the interventions, the groups were similar regarding sociodemographic characteristics, teaching activities, and vocal quality. The variations before and after the intervention in self-assessment and acoustic voice indicators have not significantly differed between the groups. In the comparison between groups before and after the six-week interventions, significant reductions in the Voice Handicap Index of subjects in both groups were observed, as wells as reduced average fundamental frequencies in the vocal warm-up group and increased shimmer in the breathing training group. Subjects from the vocal warm-up group reported speaking more easily and having their voices more improved in a general way as compared to the breathing training group.CONCLUSIONS Both interventions were similar regarding their effects on the teachers’ voice quality. However, each contribution has individually contributed to improve the teachers’ voice quality, especially the vocal warm-up.TRIAL RECORD NCT02102399, “Vocal Warm-up and Respiratory Muscle Training in Teachers”.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new family of "Fe-II(eta(5)-C5H5)" half sandwich compounds bearing a N-heteroaromatic ligand coordinated to the iron center by a nitrile functional group has been synthesized and fully characterized by NMR and UV-Vis spectroscopy. X-ray analysis of single crystal was achieved for complexes 1 and 3, which crystallized in the monoclinic P2(1)/c and monoclinic P2(1)/n space groups, respectively. Studies of interaction of these five new complexes with plasmid pBR322 DNA by atomic force microscopy showed very strong and different types of interaction. Antiproliferative tests were examined on human leukemia cancer cells (HL-60) using the MTT assay, and the IC50 values revealed excellent antiproliferative activity compared to cisplatin. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Diagnóstico e Intervenção Organizacional e Comunitária

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em termos profissionais, a satisfação no trabalho é sem dúvida um tema bastante debatido e atual. Neste sentido, este estudo teve como objetivo analisar a satisfação profissional dos enfermeiros especialistas em enfermagem de reabilitação e também averiguar se o local de trabalho ou o exercício de cuidados de especialidade influenciam a satisfação profissional deste grupo de enfermeiros. A satisfação profissional foi avaliada através da aplicação da “Escala de Avaliação da Satisfação no Trabalho dos Enfermeiros”, construída e validada por Frederico & Loureiro (2009) a 306 profissionais de Enfermagem, especialistas em enfermagem de reabilitação. O Alpha de Cronbach foi de 0,85, refletindo um bom nível de consistência interna. Foram analisadas seis dimensões da satisfação: satisfação com as chefias; satisfação com benefícios e recompensas; satisfação com a natureza do trabalho; satisfação com a comunicação; satisfação com a equipa e satisfação com os requisitos do trabalho. Foi realizado um estudo transversal analítico. Na análise estatística dos dados, recorreu-se à análise fatorial, ao coeficiente de correlação de Spearman, a testes paramétricos t-student para amostras independentes e One-Way ANOVA. Os resultados mostram que os enfermeiros especialistas em enfermagem de reabilitação encontram-se ligeiramente insatisfeitos. Os fatores de insatisfação estão relacionados com benefícios e recompensas, requisitos do trabalho e com a comunicação. A natureza do trabalho e o relacionamento com a equipa são fatores com os quais obtêm maior satisfação. Em relação às chefias existe uma aproximação à satisfação. Relativamente à avaliação do grau de satisfação profissional global, concluiu-se que os enfermeiros que exercem funções nos Cuidados de Saúde Primários encontram-se mais insatisfeitos profissionalmente, do que os que exercem a sua atividade profissional ao nível hospitalar. Os enfermeiros que exercem cuidados gerais apresentam-se mais insatisfeitos do que os que exercem cuidados de especialidade. Também a idade e a remuneração pelo cargo desempenhado são fatores determinantes. Os enfermeiros mais jovens são os que se apresentam mais insatisfeitos. Os enfermeiros que não são remunerados pelo cargo desempenhado demonstram maior insatisfação profissional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

History in Africa, n.18, pág.67-82

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty adult patients presenting dermal cysticercosis without cerebral or ocular involvement were treated with praziquantel. The first eleven cases received 60 mg/kg/day and the last nine cases 30 mg/kg/day. In both groups the daily dose was split into three oral intakes 4 to 6 hours apart and the drug administration lasted for 6 consecutive days. The latter group of patients also got dexamethasone, 3 mg daily, from one day before until four days after the treatment period with praziquantel. The drug proved to be 100% efficacious as demonstrated histopathologically by the death of the cysticerci of Taenia solium (Cysticercus cellulosae) in serial biopsies taken from the 2nd week on after the end of treatment, as well as clinically by the steady disappearence of the dermal nodules during the 6 months following the therapy. Tolerance of praziquantel was good as the incidence and severity of side-effects were not relevant. The drug safety was confirmed through laboratory tests which failed to detect any abnormal findings related to the hematopoietic, liver and kidney functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanocrystalline diamond (NCD) coatings offer an excellent alternative for tribological applications, preserving most of the intrinsic mechanical properties of polycrystalline CVD diamond and adding to it an extreme surface smoothness. Silicon nitride (Si3N4) ceramics are reported to guarantee high adhesion levels to CVD microcrystalline diamond coatings, but the NCD adhesion to Si3N4 is not yet well established. Micro-abrasion tests are appropriate for evaluating the abrasive wear resistance of a given surface, but they also provide information on thin film/substrate interfacial resistance, i.e., film adhesion. In this study, a comparison is made between the behaviour of NCD films deposited by hot-filament chemical vapour deposition (HFCVD) and microwave plasma assisted chemical vapour deposition (MPCVD) techniques. Silicon nitride (Si3N4) ceramic discs were selected as substrates. The NCD depositions by HFCVD and MPCVD were carried out using H2–CH4 and H2–CH4–N2 gas mixtures, respectively. An adequate set of growth parameters was chosen for each CVD technique, resulting in NCD films having a final thickness of 5 m. A micro-abrasion tribometer was used, with 3 m diamond grit as the abrasive slurry element. Experiments were carried out at a constant rotational speed (80 r.p.m.) and by varying the applied load in the range of 0.25–0.75 N. The wear rate for MPCVD NCD (3.7±0.8 × 10−5 m3N−1m−1) is compatible with those reported for microcrystalline CVD diamond. The HFCVD films displayed poorer adhesion to the Si3N4 ceramic substrates than the MPCVD ones. However, the HFCVD films show better wear resistance as a result of their higher crystallinity according to the UV Raman data, despite evidencing premature adhesion failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na atualidade, está a emergir um novo paradigma de interação, designado por Natural User Interface (NUI) para reconhecimento de gestos produzidos com o corpo do utilizador. O dispositivo de interação Microsoft Kinect foi inicialmente concebido para controlo de videojogos, para a consola Xbox360. Este dispositivo demonstra ser uma aposta viável para explorar outras áreas, como a do apoio ao processo de ensino e de aprendizagem para crianças do ensino básico. O protótipo desenvolvido visa definir um modo de interação baseado no desenho de letras no ar, e realizar a interpretação dos símbolos desenhados, usando os reconhecedores de padrões Kernel Discriminant Analysis (KDA), Support Vector Machines (SVM) e $N. O desenvolvimento deste projeto baseou-se no estudo dos diferentes dispositivos NUI disponíveis no mercado, bibliotecas de desenvolvimento NUI para este tipo de dispositivos e algoritmos de reconhecimento de padrões. Com base nos dois elementos iniciais, foi possível obter uma visão mais concreta de qual o hardware e software disponíveis indicados à persecução do objetivo pretendido. O reconhecimento de padrões constitui um tema bastante extenso e complexo, de modo que foi necessária a seleção de um conjunto limitado deste tipo de algoritmos, realizando os respetivos testes por forma a determinar qual o que melhor se adequava ao objetivo pretendido. Aplicando as mesmas condições aos três algoritmos de reconhecimento de padrões permitiu avaliar as suas capacidades e determinar o $N como o que apresentou maior eficácia no reconhecimento. Por último, tentou-se averiguar a viabilidade do protótipo desenvolvido, tendo sido testado num universo de elementos de duas faixas etárias para determinar a capacidade de adaptação e aprendizagem destes dois grupos. Neste estudo, constatou-se um melhor desempenho inicial ao modo de interação do grupo de idade mais avançada. Contudo, o grupo mais jovem foi revelando uma evolutiva capacidade de adaptação a este modo de interação melhorando progressivamente os resultados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho visa contribuir para o desenvolvimento de um sistema de visão multi-câmara para determinação da localização, atitude e seguimento de múltiplos objectos, para ser utilizado na unidade de robótica do INESCTEC, e resulta da necessidade de ter informação externa exacta que sirva de referência no estudo, caracterização e desenvolvimento de algoritmos de localização, navegação e controlo de vários sistemas autónomos. Com base na caracterização dos veículos autónomos existentes na unidade de robótica do INESCTEC e na análise dos seus cenários de operação, foi efectuado o levantamento de requisitos para o sistema a desenvolver. Foram estudados os fundamentos teóricos, necessários ao desenvolvimento do sistema, em temas relacionados com visão computacional, métodos de estimação e associação de dados para problemas de seguimento de múltiplos objectos . Foi proposta uma arquitectura para o sistema global que endereça os vários requisitos identi cados, permitindo a utilização de múltiplas câmaras e suportando o seguimento de múltiplos objectos, com ou sem marcadores. Foram implementados e validados componentes da arquitectura proposta e integrados num sistema para validação, focando na localização e seguimento de múltiplos objectos com marcadores luminosos à base de Light-Emitting Diodes (LEDs). Nomeadamente, os módulos para a identi cação dos pontos de interesse na imagem, técnicas para agrupar os vários pontos de interesse de cada objecto e efectuar a correspondência das medidas obtidas pelas várias câmaras, método para a determinação da posição e atitude dos objectos, ltro para seguimento de múltiplos objectos. Foram realizados testes para validação e a nação do sistema implementado que demonstram que a solução encontrada vai de encontro aos requisitos, e foram identi cadas as linhas de trabalho para a continuação do desenvolvimento do sistema global.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In August 1983 the Authors studied 36 patients with Plasmodium falciparum malaria and 14 normal individuals born in Humaita region who had never had malaria, had no spleen enlargement and had negative parasitemia as well as passive hemagglutination. Medical histories were obtained and complete physical examination were performed in all of them just as blood tests, parasite density and lymphocyte typing. The lymphocytes were separated and then frozen in liquid nitrogen for later typing by rosette formation. The patients were divided in two groups according to the presence (13 patients) or abscence (23 patients) of gametocytes before treatment. Severe malaria was predominant in the group without gametocytes. The results showed a decrease in the T-cell numbers in Plasmodium falciparum acute malaria patients both with or without gametocytes before the treatment, while B-cell numbers were normal only in the patients with gametocytes. These observations as like as those previously reported by the Authors, permit to associate the presence of gametocytes in peripheral blood and normal number of B-cells in patients with mild Plasmodium falciparum malaria.