939 resultados para goldfish, colour-blind, motion detection, trainingsexperiments, random dot pattern


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An antigen capture immunoassay to detect West Nile (WN) virus antigen in infected mosquitoes and avian tissues has been developed. With this assay purified WN virus was detected at a concentration of 32 pg/0.1 ml, and antigen in infected suckling mouse brain and laboratory-infected mosquito pools could be detected when the WN virus titer was 10(2.1) to 10(3.7) PFU/0.1 ml. In a blindly coded set of field-collected mosquito pools (n = 100), this assay detected WN virus antigen in 12 of 18 (66.7%) TaqMan-positive pools, whereas traditional reverse transcriptase PCR detected 10 of 18 (55.5%) positive pools. A sample set of 73 organ homogenates from naturally infected American crows was also examined by WN virus antigen capture immunoassay and TaqMan for the presence of WN virus. The antigen capture assay detected antigen in 30 of 34 (88.2%) TaqMan-positive tissues. Based upon a TaqMan-generated standard curve of infectious WN virus, the limit of detection in the antigen capture assay for avian tissue homogenates was approximately 10(3) PFU/0.1 ml. The recommended WN virus antigen capture protocol, which includes a capture assay followed by a confirmatory inhibition assay used to retest presumptive positive samples, could distinguish between the closely related WN and St. Louis encephalitis viruses in virus-infected mosquito pools and avian tissues. Therefore, this immunoassay demonstrates adequate sensitivity and specificity for surveillance of WN virus activity in mosquito vectors and avian hosts, and, in addition, it is easy to perform and relatively inexpensive compared with the TaqMan assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, several groups have investigated quantum analogues of random walk algorithms, both on a line and on a circle. It has been found that the quantum versions have markedly different features to the classical versions. Namely, the variance on the line, and the mixing time on the circle increase quadratically faster in the quantum versions as compared to the classical versions. Here, we propose a scheme to implement the quantum random walk on a line and on a circle in an ion trap quantum computer. With current ion trap technology, the number of steps that could be experimentally implemented will be relatively small. However, we show how the enhanced features of these walks could be observed experimentally. In the limit of strong decoherence, the quantum random walk tends to the classical random walk. By measuring the degree to which the walk remains quantum, '' this algorithm could serve as an important benchmarking protocol for ion trap quantum computers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the intrarater and interrater reliability among rheumatologists of a standardised protocol for measurement of shoulder movements using a gravity inclinometer. Methods: After instruction, six rheurnatologists independently assessed eight movements of the shoulder, including total and glenohumeral flexion, total and glenohumeral abduction, external rotation in neutral and in abduction, internal rotation in abduction and hand behind back, in random order in six patients with shoulder pain and stiffness according to a 6x6 Latin square design using a standardised protocol. These assessments were then repeated. Analysis of variance was used to partition total variability into components of variance in order to calculate intraclass correlation coefficients (ICCs). Results: The intrarater and interrater reliability of different shoulder movements varied widely. The movement of hand behind back and total shoulder flexion yielded the highest ICC scores for both intrarater reliability (0.91 and 0.83, respectively) and interrater reliability (0.80 and 0.72, respectively). Low ICC scores were found for the movements of glenohumeral abduction, external rotation in abduction, and internal rotation in abduction (intrarater ICCs 0.35, 0.43, and 0.32, respectively), and external rotation in neutral, external rotation in abduction, and internal rotation in abduction (interrater ICCs 0.29, 0.11, and 0.06, respectively). Conclusions: The measurement of shoulder movements using a standardised protocol by rheumatologists produced variable intrarater and interrater reliability. Reasonable reliability was obtained only for the movement of hand behind back and total shoulder flexion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To establish a noncontagious control for the Ray thioglycollate test for the detection of Perkinsus in mollusks we evaluated nonviable stages of P. olseni for enlargement of hypnospores and blue/black iodine stain. Trophozoites made nonviable with formalin, irradiation or colchicine failed to swell in thioglycollate. They remained small and did not differentially stain in iodine. Trophozoites that had already developed into hypnospores in thioglycollate were rendered inactive by freezing, ethanol or formalin immersion. They retained their iodinophilic properties and thus could provide a partial control for the Ray Test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cervical auscultation is in the process of gaining clinical credibility. In order for it to be accepted by the clinical community, the procedure and equipment used must first be standardized. Takahashi et al. [Dysphagia 9:54-62, 1994] attempted to provide benchmark methodology for administering cervical auscultation. They provided information about the acoustic detector unit best suited to picking up swallowing sounds and the best cervical site to place it. The current investigation provides contrasting results to Takahashi et al. with respect to the best type of acoustic detector unit to use for detecting swallowing sounds. Our study advocates an electret microphone as opposed to an accelerometer for recording swallowing sounds. However, we agree on the optimal placement site. We conclude that cervical auscultation is within reach of the average dysphagia clinic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motion study is an engineering technology that analyzes human body motions. During the past decade (1990-1999) a series of studies investigated the role of motion study in developmental disabilities. This article reviews the literature on the applications of motion study in the field. A historical and conceptual review of motion study leading to the current status of studies is presented followed by a review of the research literature. Two main eras of research focus were identified. The first era (1990-1995) of studies established the superior effectiveness and efficiency of tasks designed with motion study or motion study-related principles over traditional site-based task designs. The second era (1995-1999) of studies examined the interaction between motion study-based task designs and other variables such as choice, preference, and functionally equivalent and competing task designs and communicative alternatives. Our review found that applying motion study principles as an antecedent guide and practice to eliminating or reducing ineffective motions and simplifying effective motions resulted in positive task outcomes with most of the participants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flock-level sensitivity of pooled faecal culture and serological testing using AGID for the detection of ovine Johne's disease-infected flocks were estimated using non-gold-standard methods. The two tests were compared in an extensive field trial in 296 flocks in New South Wales during 1998. In each flock, a sample of sheep was selected and tested for ovine Johne's disease using both the AGID and pooled faecal culture. The flock-specificity of pooled faecal culture also was estimated from results of surveillance and market-assurance testing in New South Wales. The overall flock-sensitivity of pooled faecal culture was 92% (95% CI: 82.4 and 97.4%) compared to 61% (50.5 and 70.9%) for serology (assuming that both tests were 100% specific). In low-prevalence flocks (estimated prevalence

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new approach to the LU decomposition method for the simulation of stationary and ergodic random fields. The approach overcomes the size limitations of LU and is suitable for any size simulation. The proposed approach can facilitate fast updating of generated realizations with new data, when appropriate, without repeating the full simulation process. Based on a novel column partitioning of the L matrix, expressed in terms of successive conditional covariance matrices, the approach presented here demonstrates that LU simulation is equivalent to the successive solution of kriging residual estimates plus random terms. Consequently, it can be used for the LU decomposition of matrices of any size. The simulation approach is termed conditional simulation by successive residuals as at each step, a small set (group) of random variables is simulated with a LU decomposition of a matrix of updated conditional covariance of residuals. The simulated group is then used to estimate residuals without the need to solve large systems of equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and reliable polymerase chain reaction (PCR)-based protocol was developed for detecting zygosity of the 1BL/1RS translocation in hexaploid wheat. The protocol involved a multiplex PCR with 2 pairs of oligonucleotide primers, rye-specific Ris-1 primers, and consensus 5S intergenic spacer (IGS) primers, and digestion of the PCR products with the restriction enzyme, MseI. A small piece of alkali-treated intact leaf tissue is used as a template for the PCR, thereby eliminating the necessity for DNA extraction. The test is simple, highly sensitive, and rapid compared with the other detection systems of 1BS1RS heterozygotes in hexaploid wheat. PCR results were confirmed with AFLP analyses. Diagnostic tests for 1BL/1RS translocation based on Sec-1-specific ELISA, screening for chromosome arm 1RS controlled rust resistance locus Yr9, and the PCR test differed in their ability to detect heterozygotes. The PCR test and rust test detected more heterozygotes than the ELISA test. The PCR test is being used to facilitate S1 family recurrent selection in the Germplasm Enhancement Program of the Australian Northern Wheat Improvement Program. A combination of the PCR zygosity test with other markers currently being implemented in the breeding program makes this test economical for 1BL/1RS characterisation of S1 families.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the Roche LightCycler we developed a real-time reverse transcriptase polymerase chain reaction (RT-PCR) assay using the Influenza A LightCycler RT-PCR (FA-LC-RTPCR) for the rapid detection of Influenza A. The assay was used to examine 178 nasopharyngeal aspirate (NPA) samples, from patients with clinically recognised respiratory tract infection, for the presence of Influenza A RNA. The results were then compared to a testing algorithm combining direct immunofluorescent assy (DFA) and a culture augmented DFA (CA-DFA) assay. In total, 76 (43%) specimens were positive and 98 (55%) specimens were negative by both the FA-LC-RTPCR and the DFA and CA-DFA algorithm. In addition, the FA-LC-RTPCR detected a further 4 (2%) positive specimens, which were confirmed by a conventional RT-PCR method. The high level of sensitivity and specificity, combined with the rapid turnaround time for results, makes the LC-RT-PCR assay suitable for the detection of Influenza A in clinical specimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent description of the respiratory pathogen human metapneumovirus (hMPV) has highlighted a deficiency in current diagnostic techniques for viral agents associated with acute lower respiratory tract infections. We describe two novel approaches to the detection of viral RNA by use of reverse transcriptase PCR (RT-PCR). The PCR products were identified after capture onto a solid-phase medium by hybridization with a sequence-specific, biotinylated oligonucleotide probe. The assay was applied to the screening of 329 nasopharyngeal aspirates sampled from patients suffering from respiratory tract disease. These samples were negative for other common microbial causes of respiratory tract disease. We were able to detect hMPV sequences in 32 (9.7%) samples collected from Australian patients during 2001. To further reduce result turnaround times we designed a fluorogenic TaqMan oligoprobe and combined it with the existing primers for use on the LightCycler platform. The real-time RT-PCR proved to be highly reproducible and detected hMPV in an additional 6 out of 62 samples (9.6%) tested during the comparison of the two diagnostic approaches. We found the real-time RT-PCR to be the test of choice for future investigation of samples for hMPV due to its speed, reproducibility, specificity, and sensitivity.