916 resultados para enzyme marker
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Photosynthesis is the single most important source of 02 and organic chemical energy necessary to support all non-autotrophic life forms. Plants compartmentalize this elaborate biochemical process within chloroplasts in order to safely harness the power of solar energy and convert it into usable chemical units. Stresses (biotic or abiotic) that challenge the integrity of the plant cell are likely to affect photosynthesis and alter chlorophyll fluorescence. A simple three-step assay was developed to test selected herbicides representative of the known herbicide mechanisms of action and a number of natural phytotoxins to determine their effect on photosynthesis as measured by chlorophyll fluorescence. The most active compounds were those interacting directly with photosynthesis (inhibitors of photosystem I and II), those inhibiting carotenoid synthesis, and those with mechanisms of action generating reactive oxygen species and lipid peroxidation (uncouplers and inhibitors of protoporphyrinogen oxidase). Other active compounds targeted lipids (very-long-chain fatty acid synthase and removal of cuticular waxes). Therefore, induced chlorophyll fluorescence is a good biomarker to help identify certain herbicide modes of action and their dependence on light for bioactivity. Published by Elsevier B.V.
Resumo:
Many microorganisms that decompose lignocellulosic material are being studied as producers of enzymes to perform enzymatic hydrolysis of the lignocellulosic material present in residues from the agroindustries. Although the cellulose and hemicellulose present in these materials have their value for feeding cattle, their bioavailability requires breakdown of the bonds with indigestible lignin. Predigestion of such materials with ligninases, xylanases and pectinases (cellulase free) may transform the lignocellulosic substrate into a feed with greater digestibility and higher quality for ruminants.. This review provides an overview of variables to be considered in the utilization of fungal plantdepolymerizing enzymes produced by solid-state fermentation from agricultural production residues in Brazil. (c) 2007 Elsevier B. V. All rights reserved.
Resumo:
We evaluated the growth and development of the medicinal species Pothomorphe umbellata ( L.) Miq. under different shade levels ( full sun and 30, 50, and 70 % shade, marked as I(100), I(70), I(50), and I(30), respectively) and their effects on gas exchange and activities of antioxidant enzymes. Photosynthetically active radiation varied from 1 254 mu mol m(-2) s(-1) at I(100) to 285 mu mol m(-2) s(-1) at I(30). Stomatal conductance, net photosynthetic rate, and relative chlorophyll (Chl) content were maximal in I(70) plants. Plants grown under I(100) produced leaves with lower Chl content and signs of chlorosis and necrosis. These symptoms indicated Chl degradation induced by the generation of reactive oxygen species. Stress related antioxidant enzyme activities ( Mn-SOD, Fe-SOD, and Cu/Zn-SOD) were highest in I(100) plants, whereas catalase activity was the lowest. Hence P. umbellata is a shade species ( sciophyte), a feature that should be considered in reforestation programs or in field plantings for production of medicinal constituents.
Resumo:
Conselho Nacional de Desenvolvimento CientÃfico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The serological detection of antibodies against human papillomavirus (HPV) antigens is a useful tool to determine exposure to genital HPV infection and in predicting the risk of infection persistence and associated lesions. Enzyme-linked immunosorbent assays (ELISAs) are commonly used for seroepidemiological studies of HPV infection but are not standardized. Intra-and interassay performance variation is difficult to control, especially in cohort studies that require the testing of specimens over extended periods. We propose the use of normalized absorbance ratios (NARs) as a standardization procedure to control for such variations and minimize measurement error. We compared NAR and ELISA optical density (OD) values for the strength of the correlation between serological results for paired visits 4 months apart and HPV-16 DNA positivity in cervical specimens from a cohort investigation of 2,048 women tested with an ELISA using HPV-16 virus-like particles. NARs were calculated by dividing the mean blank-subtracted (net) ODs by the equivalent values of a control serum pool included in the same plate in triplicate, using different dilutions. Stronger correlations were observed with NAR values than with net ODs at every dilution, with an overall reduction in nonexplained regression variability of 39%. Using logistic regression, the ranges of odds ratios of HPV-16 DNA positivity contrasting upper and lower quintiles at different dilutions and their averages were 4.73 to 5.47 for NARs and 2.78 to 3.28 for net ODs, with corresponding significant improvements in seroreactivity-risk trends across quintiles when NARs were used. The NAR standardization is a simple procedure to reduce measurement error in seroepidemiological studies of HPV infection.
Resumo:
A new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.
Resumo:
Conselho Nacional de Desenvolvimento CientÃfico e Tecnológico (CNPq)
Resumo:
IgG, IgM and IgA antibodies to GP43 (glycoprotein fraction of Paracoccidioides brasiliensis) were measured by ELISA in 63 samples from 23 patients with paracoccidioidomycosis before and twice after chemotherapy was started. Antibodies against P. brasiliensis were detected by indirect immunofluorescence (IF) (IgG, IgM and IgA isotypes), counterimmunoelectrophoresis (CIE) and complement fixation. Two control groups composed of 19 healthy individuals and 12 patients with other diseases (six with histoplasmosis, three with tuberculosis and three with other mycoses). The highest efficiency percentages were found with IgG and IgA- ELISA (100%), IgG-IF (96.2%), CIE (94.4%) and the lowest with CF (75.9%). Highest positive and negative predictive values (100%) were observed for IgG and IgA ELISA. IgG and IgM-ELISA antibodies are more often found in patients with acute than chronic disease (P = 0.01). Four to six months after treatment follow-up showed decreased levels of IgG and IgM-ELISA for acute cases and decreased titres of CIE for chronic cases in relation to pretreatment levels. This study suggests that IgG-ELISA anti-GP43 represents a good marker to monitor clinical response to therapy.
Resumo:
A flow-injection (FI) method was developed for the determination of oxalate in urine. It was based on the use of oxalate oxidase (E.C. 1.2.3.4) immobilized on ground seeds of the BR-303 Sorghum vulgare variety. A reactor was filled with this activated material, and the samples (200 μL) containing oxalate were passed through it, carried by a deionized water flow. The carbon dioxide produced by the enzyme reaction permeated through a microporous PTFE membrane, and was received in a water acceptor stream, promoting conductivity changes proportional to the oxalate concentration in the sample. The results obtained showed a useful linear range from 0.05 to 0.50 mmol dm-3. The proposed method, when compared with the Sigma enzymatic procedure, showed good correlation (Y = 0.006(±0.016) + 0.98(±0.019)X; r = 0.9995, Y = conductivity in μS, and X = concentration in mmol dm-3), selectivity, and sensitivity. The new immobilization approach promotes greater stability, allowing oxalate determination for 6 months. About 13 determinations can be performed per hour. The precision of the proposed method is about ± 3.2 % (r.s.d).