972 resultados para endovascular repair
Resumo:
INTRODUCTION: Few data are available referring to male and female sexual function after prolapse repair of symptomatic pelvic organ. AIM: Primary aim of this study is to determine the male and female sexual function before and after surgery for pelvic organ prolapse. MAIN OUTCOME MEASURES: We used the Female Sexual Function Index (FSFI) questionnaire for female patients and for their male partners the Brief Male Sexual Inventory (BMSI) as measurement of sexual function. METHODS: We included sexually active heterosexual couples that were referred to the Department of Urogynaecology because of symptomatic cystocele, rectocele or vault descent. For cystoceles, anterior repair was performed, for rectoceles posterior repair, and for vault descent sacrospinous ligament fixation. FSFI and BMSI questionnaires were distributed before and after pelvic organ surgery and 4 months after. Female clinical examination assessing the degree of prolapse was performed before and 6 weeks after surgery. RESULTS: A full data set of 70 female questionnaires and 64 male questionnaires could be evaluated. Two cases of female de novo dyspareunia occurred. In women, FSFI scores improved significantly in the domains desire, arousal, lubrication, overall satisfaction, and particularly pain. Orgasm remained unchanged. In men, interest, sexual drive, and overall satisfaction improved significantly. Erection, ejaculatory function, and orgasm remained unchanged. Despite remaining unchanged, erection, strength of erection, ejaculation, and orgasm were not considered problems anymore compared to preoperative BMSI scores. CONCLUSION: Surgery for pelvic organ prolapse improves male and female sexual function in some domains but not in all.
Resumo:
Intra-alveolar fibrin is formed following lung injury and inflammation and may contribute to the development of pulmonary fibrosis. Fibrin turnover is altered in patients with pulmonary fibrosis, resulting in intra-alveolar fibrin accumulation, mainly due to decreased fibrinolysis. Alveolar type II epithelial cells (AEC) repair the injured alveolar epithelium by migrating over the provisional fibrin matrix. We hypothesized that repairing alveolar epithelial cells modulate the underlying fibrin matrix by release of fibrinolytic activity, and that the degree of fibrinolysis modulates alveolar epithelial repair on fibrin. To test this hypothesis we studied alveolar epithelial wound repair in vitro using a modified epithelial wound repair model with human A549 alveolar epithelial cells cultured on a fibrin matrix. In presence of the inflammatory cytokine interleukin-1beta, wounds increase by 800% in 24 hours mainly due to detachment of the cells, whereas in serum-free medium wound areas decreases by 22.4 +/- 5.2% (p < 0.01). Increased levels of D-dimer, FDP and uPA in the cell supernatant of IL-1beta-stimulated A549 epithelial cells indicate activation of fibrinolysis by activation of the plasmin system. In presence of low concentrations of fibrinolysis inhibitors, including specific blocking anti-uPA antibodies, alveolar epithelial repair in vitro was improved, whereas in presence of high concentrations of fibrinolysis inhibitors, a decrease was observed mainly due to decreased spreading and migration of cells. These findings suggest the existence of a fibrinolytic optimum at which alveolar epithelial repair in vitro is most efficient. In conclusion, uPA released by AEC alters alveolar epithelial repair in vitro by modulating the underlying fibrin matrix.
Resumo:
Structural and functional characterization of integrative cartilage repair in controlled model systems can play a key role in the development of innovative strategies to improve the long-term outcome of many cartilage repair procedures. In this work, we first developed a method to reproducibly generate geometrically defined disk/ring cartilage composites and to remove outgrown fibrous layers which can encapsulate cartilaginous tissues during culture. We then used the model system to test the hypothesis that such fibrous layers lead to an overestimation of biomechanical parameters of integration at the disk/ring interface. Transmission electron microscopy images of the composites after 6 weeks of culture indicated that collagen fibrils in the fibrous tissue layer were well integrated into the collagen network of the cartilage disk and ring, whereas molecular bridging between opposing disk/ring cartilage surfaces was less pronounced and restricted to regions with narrow interfacial regions (< 2 microm). Stress-strain profiles generated from mechanical push-out tests for composites with the layers removed displayed a single and distinct peak, whereas profiles for composites with the layers left intact consisted of multiple superimposed peaks. As compared to composites with removed layers, composites with intact layers had significantly higher adhesive strengths (161+/-9 vs. 71+/-11 kPa) and adhesion energies (15.0+/-0.7 vs. 2.7+/-0.4 mJ/mm2). By combining structural and functional analyses, we demonstrated that the outgrowing tissue formed during in vitro culture of cartilaginous specimens should be eliminated in order to reliably quantify biomechanical parameters related to integrative cartilage repair.
Resumo:
A poly(ethylene glycol) (PEG)-based hydrogel was used as a scaffold for chondrocyte culture. Branched PEG-vinylsulfone macromers were end-linked with thiol-bearing matrix metalloproteinase (MMP)-sensitive peptides (GCRDGPQGIWGQDRCG) to form a three-dimensional network in situ under physiologic conditions. Both four- and eight-armed PEG macromer building blocks were examined. Increasing the number of PEG arms increased the elastic modulus of the hydrogels from 4.5 to 13.5 kPa. PEG-dithiol was used to prepare hydrogels that were not sensitive to degradation by cell-derived MMPs. Primary bovine calf chondrocytes were cultured in both MMP-sensitive and MMP-insensitive hydrogels, formed from either four- or eight-armed PEG. Most (>90%) of the cells inside the gels were viable after 1 month of culture and formed cell clusters. Gel matrices with lower elastic modulus and sensitivity to MMP-based matrix remodeling demonstrated larger clusters and more diffuse, less cell surface-constrained cell-derived matrix in the chondron, as determined by light and electron microscopy. Gene expression experiments by real-time RT-PCR showed that the expression of type II collagen and aggrecan was increased in the MMP-sensitive hydrogels, whereas the expression level of MMP-13 was increased in the MMP-insensitive hydrogels. These results indicate that cellular activity can be modulated by the composition of the hydrogel. This study represents one of the first examples of chondrocyte culture in a bioactive synthetic material that can be remodeled by cellular protease activity.
Resumo:
PURPOSE: To report the application of a true lumen re-entry device in the bailout treatment of chronic total occlusions (CTO) of the superficial femoral artery (SFA) after failed angioplasty. METHODS: Nineteen patients (12 men; mean age 81 years, range 61-97) with 20 SFA CTOs and Rutherford category 2 to 5 ischemia were prospectively evaluated. All CTOs had unsuccessful recanalization using conventional techniques and were subsequently treated with the Outback LTD catheter. Follow-up at 3, 6, and 12 months included ankle/toe pressure measurement and pulse volume recordings. Endpoints were revascularization rate, target lesion revascularization, and limb salvage. RESULTS: Revascularization was achieved in 95% of the cases. There were 2 (10%) periprocedural complications unrelated to the re-entry device, which were resolved by endovascular or surgical treatment. The target lesion revascularization rate was 10%, with the 2 events occurring at 3 and 6 months, respectively, in patients with Rutherford category 4-5 ischemia. There was one below-the-knee amputation in the patient with failed revascularization. CONCLUSION: The acute failure of endovascular treatment of SFA CTOs is most often due to an inability to re-enter the true lumen after the occlusion is crossed in a subintimal plane. Bailout revascularization with the Outback LTD catheter is highly successful and shows a low device-related complication rate. This needle- and fluoroscopic-based re-entry device increases the endovascular success rate and is therefore expanding the minimally invasive treatment options for surgically unfit patients.
Resumo:
The purpose of this study was to analyze the immediate and long-term angiographic and clinical results of endovascular treatment of posterior circulation aneurysms with special regard to technical development.
Resumo:
Das RTeJournal möchte in seiner Rubrik:“ Repair“, Berichte aufnehmen, in denen die Reparatur oder der Ersatz von Bauteilen durch Additive Manufacturing (AM) Lösungen aufgenommen wird. Einmal als Anregung sich damit auseinander zu setzen und gleichzeitig auch als Dienstleistung beim Bedarf von Reparaturen. Es würde uns freuen, wenn Sie uns Beispiele mit einem kleinen Reparaturbericht zusenden könnten, die zum Einsatz von Additive Manufacturing führten. Email: eich@fh-aachen.de
Resumo:
Law collections pose some unique problems in terms of their physical care due to filing and updating practices, use patterns and special binding structures such as loose-leafs and pocket parts. This workshop is designed to address specific preservation needs of law collections through lecture, demonstration and hands-on opportunities. Participants will learn the fundamentals of book repair, treatment options and decision-making, and preservation best practices. Emphasis will be placed on moving knowledge into practice through guidelines for establishing institution-appropriate in house book repair programs, by training the trainers in basic book repair techniques and providing all participants with a start-up tool kit.
Resumo:
Skeletal muscle complaints are a common consequence of cholesterol-lowering therapy. Transverse tubular (T-tubular) vacuolations occur in patients having statin-associated myopathy and, to a lesser extent, in statin-treated patients without myopathy. We have investigated quantitative changes in T-tubular morphology and looked for early indicators of T-tubular membrane repair in skeletal muscle biopsy samples from patients receiving cholesterol-lowering therapy who do not have myopathic side effects. Gene expression and protein levels of incipient membrane repair proteins were monitored in patients who tolerated statin treatment without myopathy and in statin-naive subjects. In addition, morphometry of the T-tubular system was performed. Only the gene expression for annexin A1 was up-regulated, whereas the expression of other repair genes remained unchanged. However, annexin A1 and dysferlin protein levels were significantly increased. In statin-treated patients, the volume fraction of the T-tubular system was significantly increased, but the volume fraction of the sarcoplasmic reticulum remained unchanged. A complex surface structure in combination with high mechanical loads makes skeletal muscle plasma membranes susceptible to injury. Ca(2+)-dependent membrane repair proteins such as dysferlin and annexin A1 are deployed at T-tubular sites. The up-regulation of annexin A1 gene expression and protein points to this protein as a biomarker for T-tubular repair.
Resumo:
HYPOTHESIS We hypothesized that arthroscopic rotator cuff repairs using leukocyte- and platelet-rich fibrin (L-PRF) in a standardized, modified protocol is technically feasible and results in a higher vascularization response and watertight healing rate during early healing. METHODS Twenty patients with chronic rotator cuff tears were randomly assigned to 2 treatment groups. In the test group (N = 10), L-PRF was added in between the tendon and the bone during arthroscopic rotator cuff repair. The second group served as control (N = 10). They received the same arthroscopic treatment without the use of L-PRF. We used a double-row tension band technique. Clinical examinations including subjective shoulder value, visual analog scale, Constant, and Simple Shoulder Test scores and measurement of the vascularization with power Doppler ultrasonography were made at 6 and 12 weeks. RESULTS There have been no postoperative complications. At 6 and 12 weeks, there was no significant difference in the clinical scores between the test and the control groups. The mean vascularization index of the surgical tendon-to-bone insertions was always significantly higher in the L-PRF group than in the contralateral healthy shoulders at 6 and 12 weeks (P = .0001). Whereas the L-PRF group showed a higher vascularization compared with the control group at 6 weeks (P = .001), there was no difference after 12 weeks of follow-up (P = .889). Watertight healing was obtained in 89% of the repaired cuffs. DISCUSSION/CONCLUSIONS Arthroscopic rotator cuff repair with the application of L-PRF is technically feasible and yields higher early vascularization. Increased vascularization may potentially predispose to an increased and earlier cellular response and an increased healing rate.
Resumo:
Lumbar discectomy is the surgical procedure most frequently performed for patients suffering from low back pain and sciatica. Disc herniation as a consequence of degenerative or traumatic processes is commonly encountered as the underlying cause for the painful condition. While discectomy provides favourable outcome in a majority of cases, there are conditions where unmet requirements exist in terms of treatment, such as large disc protrusions with minimal disc degeneration; in these cases, the high rate of recurrent disc herniation after discectomy is a prevalent problem. An effective biological annular repair could improve the surgical outcome in patients with contained disc herniations but otherwise minor degenerative changes. An attractive approach is a tissue-engineered implant that will enable/stimulate the repair of the ruptured annulus. The strategy is to develop three-dimensional scaffolds and activate them by seeding cells or by incorporating molecular signals that enable new matrix synthesis at the defect site, while the biomaterial provides immediate closure of the defect and maintains the mechanical properties of the disc. This review is structured into (1) introduction, (2) clinical problems, current treatment options and needs, (3) biomechanical demands, (4) cellular and extracellular components, (5) biomaterials for delivery, scaffolding and support, (6) pre-clinical models for evaluation of newly developed cell- and material-based therapies, and (7) conclusions. This article highlights that an interdisciplinary approach is necessary for successful development of new clinical methods for annulus fibrosus repair. This will benefit from a close collaboration between research groups with expertise in all areas addressed in this review.
Resumo:
BACKGROUND Reconstruction of defects of the lateral nasal ala might be challenging. Reconstruction with a bi- or trilobed flap is common. The laterally based bi- or trilobed flap for defects of the distal ala or lateral tip of the nose produces mostly tissue protrusion in the nasal groove which is aesthetically unpleasant. Why not use more the medially based bi- or trilobed flap? OBJECTIVE To describe the utility of bilobed and trilobed flaps for alar defects insisting on the design of medially based flaps. METHODS To show the technique and practical application for this kind of reconstruction. RESULTS The bi- and trilobed flaps are useful for defect repair between the lateral nasal tip and the distal ala. We observed that in most cases the flap based medially respects anatomical subunits better than the laterally based flap for medium-sized defects of the distal ala of the nose. CONCLUSION I suggest that the bi- and trilobed flaps for repair of the lateral tip/distal ala should more often be medially based. This flap has a specific indication and precise advantage compared to other reconstructions, especially to the laterally based multilobed flaps in this specific indication.