949 resultados para dual-wavelength


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate dynamic posture control and working memory (NBack) retest practice in young and older adults, focusing on older adults' potential for improvement in the component tasks but more importantly in dual-task performance. Participants performed the 2 tasks in 11 sessions under single- and dual-task conditions. Posture improvement was observed with retest practice for both groups. Increase in cognitive load after initial practice led to greater dual-task costs in both tasks in older adults and higher costs in memory in young adults. With continued practice, costs were reduced by both groups; however, the 2 groups focused improvement on different tasks: Older adults focused on posture but young adults on cognition. These results emphasize older adults' potential for improvement in dual-task performance and their flexibility to utilize the practice gains in posture to optimize cognitive performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study it has been demonstrated that mixtures of two solid drugs, ibuprofen and methyl nicotinate, with different but complementary pharmacological activities and which exist as a single liquid phase over a wide composition range at skin temperature, can be formulated as o/w emulsions without the use of an additional hydrophobic carrier. These novel dual drug systems provided significantly enhanced in vitro penetration rates through a model lipophilic barrier membrane compared to conventional individual formulations of each active. Thus, for ibuprofen, drug penetration flux enhancements of three- and 10-fold were observed when compared to an aqueous ibuprofen suspension and a commercial alcohol-based ibuprofen formulation, respectively. Methyl nicotinate penetration rates were shown to be similar for aqueous gels and emulsified systems. Mechanisms explaining these observations are proposed. Novel dual drug formulations of ibuprofen and methyl nicotinate, formulated within the liquid range at skin temperature, were investigated by oscillatory rheology and texture profile analysis. demonstrating the effects of drug and viscosity enhancer concentrations, and disperse phase type upon the rheological, mechanical and drug penetration properties of these systems. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Theoretical emission-line ratios involving Fe xi transitions in the 257-407 A wavelength range are derived using fully relativistic calculations of radiative rates and electron impact excitation cross-sections. These are subsequently compared with both long wavelength channel Extreme-Ultraviolet Imaging Spectrometer (EIS) spectra from the Hinode satellite (covering 245-291 A) and first-order observations (similar to 235-449 A) obtained by the Solar Extreme-ultraviolet Research Telescope and Spectrograph (SERTS). The 266.39, 266.60 and 276.36 A lines of Fe xi are detected in two EIS spectra, confirming earlier identifications of these features, and 276.36 A is found to provide an electron density (N-e) diagnostic when ratioed against the 257.55 A transition. Agreement between theory and observation is found to be generally good for the SERTS data sets, with discrepancies normally being due to known line blends, while the 257.55 A feature is detected for the first time in SERTS spectra. The most useful Fe xi electron density diagnostic is found to be the 308.54/352.67 intensity ratio, which varies by a factor of 8.4 between N-e = 108 and 1011 cm-3, while showing little temperature sensitivity. However, the 349.04/352.67 ratio potentially provides a superior diagnostic, as it involves lines which are closer in wavelength, and varies by a factor of 14.7 between N-e = 108 and 1011 cm-3. Unfortunately, the 349.04 A line is relatively weak, and also blended with the second-order Fe x 174.52 A feature, unless the first-order instrument response is enhanced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

beta-Agonists are among the most widely abused drugs in veterinary medicine for the illegal promotion of farm animal growth. An array of analytical procedures has been developed to detect the residues of these compounds in many biological materials. As the number of beta-agonist formulations increases, it has become increasingly difficult to devise screening techniques capable of detecting a broad spectrum of these residues in a single test. A dual immunoassay based on time-resolved fluorescence was developed that incorporated a monoclonal antibody raised to tertiary butyl amines and a polyclonal antibody to biphenolic beta-agonists. This assay was capable of detecting residues of a range of beta-agonists present in bovine urine without the need for sample extraction. The limits of detection of the assay ranged from 1 to 8.5 ng ml(-1) depending on the cross-reactivity of individual compounds with the antibodies employed in the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics of an extreme-ultraviolet (XUV) continuum light source and its application to a dual-laser plasma (DLP) photoabsorption experiment are described. The continuum emitting plasma was formed by focusing a 7 ps, 248 nm, 15 mJ laser pulse onto a number of selected targets known to be good XUV continuum emitters (Sm, W, Au and Pb), while the second absorbing plasma was produced by a 15 ns, 1064 nm, 300 mi pulse. The duration of the continuum emission for these plasmas has a mean value of similar to 150 ps, but depends on both the target material and the picosecond laser pulse energy. Using this picosecond DLP set-up we have been able to measure the photoabsorption spectrum of an actinide ion (thorium) for the first time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accurate control of the relative phase of multiple distinct sources of radiation produced by high harmonic generation is of central importance in the continued development of coherent extreme UV (XUV) and attosecond sources. Here, we present a novel approach which allows extremely accurate phase control between multiple sources of high harmonic radiation generated within the Rayleigh range of a single-femtosecond laser pulse using a dualgas, multi-jet array. Fully ionized hydrogen acts as a purely passive medium and allows highly accurate control of the relative phase between each harmonic source. Consequently, this method allows quantum path selection and rapid signal growth via the full coherent superposition of multiple HHG sources (the so-called quasi-phase-matching). Numerical simulations elucidate the complex interplay between the distinct quantum paths observed in our proof-of-principle experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High harmonic generation (HHG) is a central driver of the rapidly growing field of ultrafast science. We present a novel quasiphase-matching (QPM) concept with a dual-gas multijet target leading, for the first time, to remarkable phase control between multiple HHG sources (> 2) within the Rayleigh range. The alternating jet structure with driving and matching zones shows perfect coherent buildup for up to six QPM periods. Although not in the focus of the proof-of-principle studies presented here, we achieved competitive conversion efficiencies already in this early stage of development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The generation of the third and fourth harmonics from the interaction of a 1 ps, ultraviolet (UV), krypton fluoride (KrF) laser with a solid surface is investigated. The conversion efficiency is seen to increase linearly with I lambda(2), with a transition from specular harmonic emission to emission into 2 pi steradians occurring between 10(15) and 10(16) W cm(-2) mu m(2). The diffuse emission is strongly dependent on the incidence angle of the laser, with the peak in emission at around 30 degrees being consistent with measurements for resonance absorption. Finally, the conversion efficiencies are found to be in agreement with particle-in-cell (PIC) simulations including appropriate density scalelengths. (C) 1998 Elsevier Science B.V.