978 resultados para certified reference values


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS®, in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Materials and Methods Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. Results The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. Conclusion The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Score-based biotic indices are widely used to evaluate the water quality of streams and rivers. Few adaptations of these indices have been done for South America because there is a lack of knowledge on mac-roinvertebrate taxonomy, distribution and tolerance to pollution in the region. Several areas in the Andes are densely populated and there is need for methods to assess the impact of increasing human pressures on aquatic ecosystems. Considering the unique ecological and geographical features of the Andes, macroinvertebrate indices used in other regions must be adapted with caution. Here we present a review of the literature on mac-roinvertebrate distribution and tolerance to pollution in Andean areas above 2 000masl. Using these data, we propose an Andean Biotic Index (ABI), which is based on the BMWP index. In general, ABI includes fewer macroinvertebrate families than in other regions of the world where the BMWP index has been applied because altitude restricts the distribution of several families. Our review shows that in the high Andes, the tolerance of several macroinvertebrate families to pollution differs from those reported in other areas. We tested the ABI index in two basins in Ecuador and Peru, and compared it to other BMWP adaptations using the reference condi-tion approach. The ABI index is extremely useful for detecting the general impairment of rivers but class quality boundaries should be defined independently for each basin because reference conditions may be different. The ABI is widely used in Ecuador and Peru, with high correlations with land-use pressures in several studies. The ABI index is an integral part of the new multimetric index designed for high Andean streams (IMEERA). Rev. Biol. Trop. 62 (Suppl. 2): 249-273. Epub 2014 April 01.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work a closed-vessel microwave-assisted acid decomposition procedure for clays was developed. Aluminum, Ca, Fe, K, Mg, Na, Si, and Ti were determined in clay digestates by inductively coupled plasma optical emission spectrometry. The most critical parameter for total decomposition of clays was the composition of the reagent mixture. The applied power and the heating time exerted a less critical influence. Best decomposition conditions were attained using a reagent mixture containing 4 mL aqua regia plus 3 mL HF and the heating program was implemented in 12 min. The accuracy of the results was demonstrated using two standard reference materials and a paired t-test showed a good agreement between determined and certified values at a 95% confidence level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of factorial design was evaluated for optimization of focused-microwave-assisted digestion of bean samples. Calcium, Fe, Mg, Mn and Zn percentual recoveries were determined in digestates after focused-microwave-assisted digestion according to factorial design procedures. A cavity microwave digestion was carried out to certify the elemental compositions obtained. The accuracy was checked using a standard reference material, the NIST SRM 8433 - Corn Bran. Results are in agreement with certified values at the 95% confidence limit when the Student t-test was used. Volumes of nitric and sulfuric acid, temperature, and the interplay between HNO3 and H2SO4 initial volumes were significant variables according to P-values in the analysis of variance (ANOVA).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aikuispotilaan kotisyntyisen keuhkokuumeen etiologinen diagnostiikka mikrobiologisilla pikamenetelmillä Tausta. Keuhkokuume on vakava sairaus, johon sairastuu Suomessa vuosittain n. 60 000 aikuista. Huolimatta siitä, että taudin hoito on kehittynyt, siihen liittyy yhä merkittävä, 6-15%:n kuolleisuus. Alahengitystieinfektion aiheuttajamikrobien tunnistaminen on myös edelleen haasteellista. Tavoitteet. Tämän työn tavoitteena oli tutkia Turun yliopistollisessa keskussairaalassa hoidettujen aikuispotilaiden keuhkokuumeen etiologiaa sekä selvittää uusien mikrobiologisten pikamenetelmi¬en hyödyllisyyttä taudinaiheuttajan toteamisessa. Aineisto. Osatöiden I ja III aineisto koostui 384 Turun yliopistollisen keskussairaalaan infektio-osastolla hoidetusta keuhkokuumepotilaasta. Osatyössä I tutkittiin keuhkokuumeen aiheuttaja¬mikrobeja käyttämällä perinteisten menetelmien lisäksi antigeeniosoitukseen ja PCR-tekniikkaan perustuvia pikamenetelmiä. Osatyö II käsitti 231 potilaasta koostuvan alaryhmän, jossa tutkittiin potilaiden nielun limanäytteestä rinovirusten ja enterovirusten esiintyvyyttä. Osatyössä III potilailta tutkittiin plasman C-reaktiivisen proteiinin (CRP) pitoisuus ensimmäisten viiden sairaalahoitopäi¬vän aikana. Laajoja tilastotieteellisiä analyysejä käyttämällä selvitettiin CRP:n käyttökelpoisuutta sairauden vaikeusasteen arvioinnissa ja komplikaatioiden kehittymisen ennustamisessa. Osatyössä IV 68 keuhkokuumepotilaan sairaalaan tulovaiheessa otetuista näytteistä määritettiin neutrofiilien pintareseptorien ekspressio. Osatyössä V analysoitiin sisätautien vuodeosastoilla vuosina 1996-2000 keuhkokuumepotilaille tehtyjen keuhkohuuhtelunäytteiden laboratoriotutkimustulokset. Tulokset. Keuhkokuumeen aiheuttaja löytyi 209 potilaalta, aiheuttajamikrobeja löydettiin kaikkiaan 230. Näistä aiheuttajista 135 (58.7%) löydettiin antigeenin osoituksella tai PCR-menetelmillä. Suu¬rin osa, 95 (70.4%), todettiin pelkästään kyseisillä pikamenetelmillä. Respiratorinen virus todettiin antigeeniosoituksella 11.1% keuhkokuumepotilaalla. Eniten respiratorisia viruksia löytyi vakavaa keuhkokuumetta sairastavilta potilailta (20.3%). 231 keuhkokuumepotilaan alaryhmässä todettiin PCR-menetelmällä picornavirus 19 (8.2%) potilaalla. Respiratorinen virus löytyi tässä potilasryh¬mässä kaiken kaikkiaan 47 (20%) potilaalta. Näistä 17:llä (36%) löytyi samanaikaisesti bakteerin aiheuttama infektio. CRP-tasot olivat sairaalaan tulovaiheessa merkitsevästi korkeammat vakavaa keuhkokuumetta (PSI-luokat III-V) sairastavilla potilailla kuin lievää keuhkokuumetta (PSI-luokat I-II) sairastavilla potilailla (p <0.001). Yli 100 mg/l oleva CRP-taso neljän päivän kuluttua sairaa¬laan tulosta ennusti keuhkokuumeen komplikaatiota tai huonoa hoitovastetta. Neutrofiilien komple¬menttireseptorin ekspressio oli pneumokokin aiheuttamaa keuhkokuumetta sairastavilla merkitse¬västi korkeampi kuin influenssan aiheuttamaa keuhkokuumetta sairastavilla. BAL-näytteistä vain yhdessä 71:stä (1.3%) todettiin diagnostinen bakteerikasvu kvantitatiivisessa viljelyssä. Uusilla menetelmilläkin keuhkokuumeen aiheuttaja löytyi vain 9.8% BAL-näytteistä. Päätelmät. Uusilla antigeeniosoitus- ja PCR-menetelmillä keuhkokuumeen etiologia voidaan saada selvitettyä nopeasti. Lisäksi näitä menetelmiä käyttämällä taudin aiheuttajamikrobi löytyi huomattavasti suuremmalta osalta potilaista kuin pelkästään tavanomaisia menetelmiä käyttämällä. Pikamenetelmien hyödyllisyys vaihteli taudin vaikeusasteen mukaan. Respiratorinen virus löytyi huomattavan usein keuhkokuumetta sairastavilta potilailta, ja näiden potilaiden taudinkuva oli usein vaikea. Tulovaiheen korkeaa CRP-tasoa voidaan käyttää lisäkeinona arvioitaessa keuhkokuumeen vaikeutta. CRP on erityisen hyödyllinen arvioitaessa hoitovastetta ja riskiä komplikaatioiden ke¬hittymiseen. Neutrofiilien komplementtireseptorin ekspression tutkiminen näyttää lupaavalta pi¬kamenetelmältä erottamaan bakteerien ja virusten aiheuttamat taudit toisistaan. Antimikrobihoitoa saavilla potilailla BAL-tutkimuksen löydökset olivat vähäiset ja vaikuttivat hoitoon vain harvoin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports the development of a methodology for simultaneously determining As, Cd and Pb, employing GF AAS with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of pyrolysis and atomization temperatures and the amount of chemical modifiers were studied. Factorial and central composite designs were used to optimize these variables. Precision and accuracy of the method were investigated using Natural Water Reference material, Nist SRM 1640. Results are in agreement with certified values at the 95% confidence limit when the Student t-test is used. This methodology was used for quality control of purified water for hemodialysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evapotranspiration is the process of water loss of vegetated soil due to evaporation and transpiration, and it may be estimated by various empirical methods. This study had the objective to carry out the evaluation of the performance of the following methods: Blaney-Criddle, Jensen-Haise, Linacre, Solar Radiation, Hargreaves-Samani, Makkink, Thornthwaite, Camargo, Priestley-Taylor and Original Penman in the estimation of the potential evapotranspiration when compared to the Penman-Monteith standard method (FAO56) to the climatic conditions of Uberaba, state of Minas Gerais, Brazil. A set of 21 years monthly data (1990 to 2010) was used, working with the climatic elements: temperature, relative humidity, wind speed and insolation. The empirical methods to estimate reference evapotranspiration were compared with the standard method using linear regression, simple statistical analysis, Willmott agreement index (d) and performance index (c). The methods Makkink and Camargo showed the best performance, with "c" values ​​of 0.75 and 0.66, respectively. The Hargreaves-Samani method presented a better linear relation with the standard method, with a correlation coefficient (r) of 0.88.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concern related to environment is growing. Due to this, it is needed to determine chemical elements in a large range of concentration. The neutron activation technique (NAA) determines the elemental composition by the measurement of artificial radioactivity in a sample that was submitted to a neutron flux. NAA is a sensitive and accurate technique with low detection limits. An example of application of NAA was the measurement of concentrations of rare earth elements (REE) in waste samples of phosphogypsum (PG) and cerrado soil samples (clayey and sandy soils). Additionally, a soil reference material of the International Atomic Energy Agency (IAEA) was also analyzed. The REE concentration in PG samples was two times higher than those found in national fertilizers, (total of 4,000 mg kg-1 ), 154 times greater than the values found in the sandy soil (26 mg kg-1 ) and 14 times greater than the in clayey soil (280 mg kg-1 ). The experimental results for the reference material were inside the uncertainty of the certified values pointing out the accuracy of the method (95%). The determination of La, Ce, Pr, Nd, Pm, Sm, Eu, Tb, Dy, Ho, Er, Tm, Yb and Lu in the samples and reference material confirmed the versatility of the technique on REE determination in soil and phosphogypsum samples that are matrices for agricultural interest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The consideration of the streamflow seasonality has a high potential to improve the water use. In order to give subsidies to the optimization of water use, it was evaluated the impact of the change of reference annual streamflow by the monthly streamflows in the potential water use throughout the hydrography of Paracatu sub-Basin. It was evaluated the impact on Q7,10 (lowest average streamflow during a 7-day period with an average recurrence of 10 years) and on Q95 (permanent flow present 95% of the time). The use of monthly streamflow to substitute the annual streamflow had a high potential of improvement of water resources use in the sub-Basin studied. The use of monthly Q 7,10 in substitution of annual Q 7,10 increases the potential water use that vary from about 10% in the months of lower water availability to values exceeding 200% in the months with higher availability of surface water resources. The use of monthly Q95 in substitution of the annual Q95 implies in changes oscillating from reduction of 37% in months of higher water restriction to values exceeding 100% in the months of higher availability, so the use of monthly Q95 instead of the annual Q95 enables the more rational and safe use of water resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim was to provide reference data for blood gas/acid-base status and electrolytes for non-anesthetized Amazon parrots (Amazona aestiva). Thirty-five adult parrots from Tietê ecologic park were utilized. Arterial blood (0.3ml) samples were anaerobically collected from the superficial ulnar artery in heparinized (sodium heparin) 1-ml plastic syringes. The samples were immediately analyzed through a portable analyzer (i-STAT*, Abbot, Illinois, USA) with cartridges (EG7+). These data were grouped in such a way as to present both mean and standard deviation: body weight (360±37g), respiratory rate (82±33 b/m), temperature (41.8±0.6°C), hydrogen potential (7.452±0.048), carbon dioxide partial pressure (22.1±4.0mmHg), oxygen partial pressure (98.1±7.6mmHg), base excess (-7.9±3.1), plasma concentration of bicarbonate ions (14.8±2.8mmol/L), oxygen saturation (96.2±1.1%), plasma concentration of sodium (147.4±2.2mmol/L), plasma concentration of potassium (3.5±0.53mmol/L), plasma concentration of calcium (0.8±0.28mmol/L), hematocrit (38.7±6.2%) and concentration of hemoglobin (13.2±2.1g/dl). This study led us to conclude that, although the results obtained showed hypocapnia and low values of bicarbonate and base excess, when compared to other avian species, these data are very similar. Besides, in spite of the equipment being approved only for human beings, it was considered simple and very useful in the analysis of avian blood samples. By using this equipment we were able to provide references data for non-anaesthetized Amazon parrots.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Decreasing of harpy eagle (Harpia harpyja) populations in natural environments, mainly in non-preserved areas, makes captive population management an important contribution to genetic diversity conservation. The aim of this study is to evaluate hematological parameters for captive harpy eagles maintained at the wild animals breeding center of Itaipu Binacional, Paraná State, Brazil. Fourteen blood samples from nine harpy eagles were collected from animals of both sexes, of different ages and with no clinical signs of disease. Significant variations were found in haematological values of hematocrit, hemoglobin, mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), leukocyte, a relative number of heterophils, absolute and relative number of lymphocytes, monocytes, eosinophils, basophils and plasma protein between groups of young (less than six months old) and adult birds. Comparing males and females there was variation in the values of erythrocytes, hemoglobin, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) on heterophils, absolute and relative number of lymphocytes, eosinophils and basophils. There was also variation in the values of red blood cells, hematocrit, hemoglobin, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), leukocyte count, absolute number of lymphocytes, eosinophils and basophils among birds that study compared to another reference birds. Due to the limited information available on harpy eagle hematology, this study will be useful to the clinical assessment of birds maintained in captivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Waste combustion has gone from being a volume reducing discarding-method to an energy recovery process for unwanted material that cannot be reused or recycled. Different fractions of waste are used as fuel today, such as; municipal solid waste, refuse derived fuel, and solid recovered fuel. Furthermore, industrial waste, normally a mixture between commercial waste and building and demolition waste, is common, either as separate fuels or mixed with, for example, municipal solid waste. Compared to fossil or biomass fuels, waste mixtures are extremely heterogeneous, making it a complicated fuel. Differences in calorific values, ash content, moisture content, and changing levels of elements, such as Cl and alkali metals, are common in waste fuel. Moreover, waste contains much higher levels of troublesome trace elements, such as Zn, which is thought to accelerate a corrosion process. Varying fuel quality can be strenuous on the boiler system and may cause fouling and corrosion of heat exchanger surfaces. This thesis examines waste fuels and waste combustion from different angles, with the objective of giving a better understanding of waste as an important fuel in today’s fuel economy. Several chemical characterisation campaigns of waste fuels over longer time periods (10-12 months) was used to determine the fossil content of Swedish waste fuels, to investigate possible seasonal variations, and to study the presence of Zn in waste. Data from the characterisation campaigns were used for thermodynamic equilibrium calculations to follow trends and determine the effect of changing concentrations of various elements. The thesis also includes a study of the thermal behaviour of Zn and a full—scale study of how the bed temperature affects the volatilisation of alkali metals and Zn from the fuel. As mixed waste fuel contains considerable amounts of fresh biomass, such as wood, food waste, paper etc. it would be wrong to classify it as a fossil fuel. When Sweden introduced waste combustion as a part of the European Union emission trading system in the beginning of 2013 there was a need for combustion plants to find a usable and reliable method to determine the fossil content. Four different methods were studied in full-scale of seven combustion plants; 14Canalysis of solid waste, 14C-analysis of flue gas, sorting analysis followed by calculations, and a patented balance method that is using a software program to calculate the fossil content based on parameters from the plant. The study showed that approximately one third of the coal in Swedish waste mixtures has fossil origins and presented the plants with information about the four different methods and their advantages and disadvantages. Characterisation campaigns also showed that industrial waste contain higher levels of trace elements, such as Zn. The content of Zn in Swedish waste fuels was determined to be approximately 800 mg kg-1 on average, based on 42 samples of solid waste from seven different plants with varying mixtures between municipal solid waste and industrial waste. A review study of the occurrence of Zn in fuels confirmed that the highest amounts of Zn are present in waste fuels rather than in fossil or biomass fuels. In tires, Zn is used as a vulcanizing agent and can reach concentration values of 9600-16800 mg kg-1. Waste Electrical and Electronic Equipment is the second Zn-richest fuel and even though on average Zn content is around 4000 mg kg-1, the values of over 19000 mg kg-1 were also reported. The increased amounts of Zn, 3000-4000 mg kg-1, are also found in municipal solid waste, sludge with over 2000 mg kg-1 on average (some exceptions up to 49000 mg kg-1), and other waste derived fuels (over 1000 mg kg-1). Zn is also found in fossil fuels. In coal, the average level of Zn is 100 mg kg-1, the higher amount of Zn was only reported for oil shale with values between 20-2680 mg kg-1. The content of Zn in biomass is basically determined by its natural occurrence and it is typically 10-100 mg kg-1. The thermal behaviour of Zn is of importance to understand the possible reactions taking place in the boiler. By using thermal analysis three common Zn-compounds were studied (ZnCl2, ZnSO4, and ZnO) and compared to phase diagrams produced with thermodynamic equilibrium calculations. The results of the study suggest that ZnCl2(s/l) cannot exist readily in the boiler due to its volatility at high temperatures and its conversion to ZnO in oxidising conditions. Also, ZnSO4 decomposes around 680°C, while ZnO is relatively stable in the temperature range prevailing in the boiler. Furthermore, by exposing ZnO to HCl in a hot environment (240-330°C) it was shown that chlorination of ZnO with HCl gas is possible. Waste fuel containing high levels of elements known to be corrosive, for example, Na and K in combination with Cl, and also significant amounts of trace elements, such as Zn, are demanding on the whole boiler system. A full-scale study of how the volatilisation of Na, K, and Zn is affected by the bed temperature in a fluidised bed boiler was performed parallel with a lab-scale study with the same conditions. The study showed that the fouling rate on deposit probes were decreased by 20 % when the bed temperature was decreased from 870°C to below 720°C. In addition, the lab-scale experiments clearly indicated that the amount of alkali metals and Zn volatilised depends on the reactor temperature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thromboelastography (TEG®) provides a functional evaluation of coagulation. It has characteristics of an ideal coagulation test for trauma, but is not frequently used, partially due to lack of both standardized techniques and normal values. We determined normal values for our population, compared them to those of the manufacturer and evaluated the effect of gender, age, blood type, and ethnicity. The technique was standardized using citrated blood, kaolin and was performed on a Haemoscope 5000 device. Volunteers were interviewed and excluded if pregnant, on anticoagulants or having a bleeding disorder. The TEG® parameters analyzed were R, K, α, MA, LY30, and coagulation index. All volunteers outside the manufacturer’s normal range underwent extensive coagulation investigations. Reference ranges for 95% for 118 healthy volunteers were R: 3.8-9.8 min, K: 0.7-3.4 min, α: 47.8-77.7 degrees, MA: 49.7-72.7 mm, LY30: -2.3-5.77%, coagulation index: -5.1-3.6. Most values were significantly different from those of the manufacturer, which would have diagnosed coagulopathy in 10 volunteers, for whom additional investigation revealed no disease (81% specificity). Healthy women were significantly more hypercoagulable than men. Aging was not associated with hypercoagulability and East Asian ethnicity was not with hypocoagulability. In our population, the manufacturer’s normal values for citrated blood-kaolin had a specificity of 81% and would incorrectly identify 8.5% of the healthy volunteers as coagulopathic. This study supports the manufacturer’s recommendation that each institution should determine its own normal values before adopting TEG®, a procedure which may be impractical. Consideration should be given to a multi-institutional study to establish wide standard values for TEG®.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.