848 resultados para breastfeeding, breastmilk, paediatric nurses, attitudes, knowledge
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
ABSTRACT OBJECTIVE To identify factors associated with exclusive breastfeeding in the first six months of life in Brazil. METHODS Systematic review of epidemiological studies conducted in Brazil with exclusive breastfeeding as outcome. Medline and LILACS databases were used. After the selection of articles, a hierarchical theoretical model was proposed according to the proximity of the variable to the outcome. RESULTS Of the 67 articles identified, we selected 20 cross-sectional studies and seven cohort studies, conducted between 1998 and 2010, comprising 77,866 children. We identified 36 factors associated with exclusive breastfeeding, being more often associated the distal factors: place of residence, maternal age and education, and the proximal factors: maternal labor, age of the child, use of a pacifier, and financing of primary health care. CONCLUSIONS The theoretical model developed may contribute to future research, and factors associated with exclusive breastfeeding may subsidize public policies on health and nutrition.
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
Objectives: Children have a greater risk from radiation, per unit dose, due to increased radiosensitivity and longer life expectancies. It is of paramount importance to reduce the radiation dose received by children. This research concerns chest CT examinations on paediatric patients. The purpose of this study was to compare the image quality and the dose received from imaging with images reconstructed with filtered back projection (FBP) and five strengths of Sinogram-Affirmed Iterative Reconstruction (SAFIRE). Methods: Using a multi-slice CT scanner, six series of images were taken of a paediatric phantom. Two kVp values (80 and 110), 3 mAs values (25, 50 and 100) and 2 slice thicknesses (1 mm and 3 mm) were used. All images were reconstructed with FBP and five strengths of SAFIRE. Ten observers evaluated visual image quality. Dose was measured using CT-Expo. Results: FBP required a higher dose than all SAFIRE strengths to obtain the same image quality for sharpness and noise. For sharpness and contrast image quality ratings of 4, FBP required doses of 6.4 and 6.8 mSv respectively. SAFIRE 5 required doses of 3.4 and 4.3 mSv respectively. Clinical acceptance rate was improved by the higher voltage (110 kV) for all images in comparison to 80 kV, which required a higher dose for acceptable image quality. 3 mm images were typically better quality than 1 mm images. Conclusion: SAFIRE 5 was optimal for dose reduction and image quality.
Resumo:
Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.
Resumo:
This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.
Resumo:
This paper reviews the literature for lowering of dose to paediatric patients through use of exposure factors and additional filtration. Dose reference levels set by The International Commission on Radiological Protection (ICRP) will be considered. Guidance was put in place in 1996 requires updating to come into line with modern imaging equipment. There is a wide range of literature that specifies that grids should not be used on paediatric patients. Although much of the literature advocates additional filtration, contrasting views on the relative benefits of using aluminium or copper filtration, and their effects on dose reduction and image quality can vary. Changing kVp and mAs has an effect on the dose to the patient and image quality. Collimation protects adjacent structures whilst reducing scattered radiation.
Resumo:
Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.
Resumo:
This text is based on a research, which is still in progress, whose main objective is to identify and understand what are the main difficulties of future mathematics teachers of basic education are, regarding their content knowledge in geometry in the context of the curricular unit of Geometry during their undergraduate degree. We chose a qualitative approach in the form of case study, in which data collection was done through observation, interviews, a diverse set of tasks, a diagnostic test and other documents. This paper focuses on the test given to prospective teachers at the beginning of the course. The preliminary analysis of the data points to a weak performance of preservice teachers in the test issues addressing elementary knowledge of Geometry.
Resumo:
Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática
Resumo:
O tema da inteligência emocional tem vindo a ganhar protagonismo no plano pessoal, organizacional e societário. A emocionalidade e a racionalidade devem ser ambas consideradas e valorizadas de forma equilibrada. Este estudo teve como amostra 507 enfermeiros a trabalhar em organizações do ramo da saúde. Estes profissionais têm uma tarefa complexa, uma vez que lidam diariamente com pessoas, que devido à sua situação de saúde fragilizada, estão mais vulneráveis e com o seu estado emocional mais alterado, o que remete para a necessidade de avaliar o desenvolvimento emocional dos mesmos. Definimos como objetivo geral contribuir para um maior conhecimento empírico sobre o desenvolvimento emocional em adultos. Os objetivos específicos são: a tradução e validação do questionário de desenvolvimento emocional em adultos (QDE_A) de Pérez-Escoda, Bisquerra, Filella e Soldevila (2010), adaptado à situação portuguesa, em enfermeiros; e a avaliação do desenvolvimento emocional dos mesmos. No que respeita à metodologia, o estudo é de carácter quantitativo, descritivo, exploratório e inferencial. Numa amostra de 507 enfermeiros, de duas regiões com caraterísticas socioeconómicas distintas, foi aplicado o QDE_A.A validação do mesmo foi concretizada através de uma análise fatorial exploratória e de uma análise fatorial confirmatória (CFA). Como objetivado foi conseguida a validação do QDE_A, tendo sido obtido um modelo constituído por cinco dimensões do desenvolvimento emocional, muito aproximado ao modelo proposto por Goleman (1995), sendo, assim, possível a sua utilização em investigações futuras e em intervenções na área da gestão dos recursos humanos e coaching. Relativamente ao objetivo de estudo, sobre o desenvolvimento emocional dos enfermeiros, verificámos que estes possuem níveis médios a elevados de desenvolvimento emocional global e que, dentro das dimensões, a auto motivação e a gestão das emoções são as mais evidenciadas, tendo em vista o incremento do desenvolvimento da inteligência emocional destes profissionais.
Resumo:
In this paper, we introduce an innovative course in the Portuguese Context, the Master's Course in “Integrated Didactics in Mother Tongue, Maths, Natural and Social Sciences”, taking place at the Lisbon School of Education and discussing in particular the results of the evaluation made by the students who attended the Curricular Unit - Integrated Didactics (CU-ID). This course was designed for in-service teachers of the first six years of schooling and intends to improve connections between different curriculum areas. In this paper, we start to present a few general ideas about curriculum development; to discuss the concept of integration; to present the principles and objectives of the course created as well as its structure; to describe the methodology used in the evaluation process of the above mentioned CU-ID. The results allow us to state that the students recognized, as positive features of the CU-ID, the presence in all sessions of two teachers simultaneously from different scientific areas, as well as invitations issued to specialists on the subject of integration and to other teachers that already promote forms of integration in schools. As negative features, students noted a lack of integrated purpose, applying simultaneously the four scientific areas of the course, and also indicated the need to be familiar with more models of integrated education. Consequently, the suggestions for improvement derived from these negative features. The students also considered that their evaluation process was correct, due to the fact that it was focused on the design of an integrated project for one of the school years already mentioned.
Resumo:
Paper presented at the 9th European Conference on Knowledge Management, Southampton Solent University, Southampton, UK, 4-5 Sep. 2008. URL: http://academic-conferences.org/eckm/eckm2008/eckm08-home.htm
Resumo:
Paper presented at the 8th European Conference on Knowledge Management, Barcelona, 6-7 Sep. 2008 URL: http://www.academic-conferences.org/eckm/eckm2007/eckm07-home.htm
Resumo:
This paper appears in International Journal of Projectics. Vol 4(1), pp. 39-49