965 resultados para arc welding acoustics
Resumo:
Cascaded multilevel inverters-based Static Var Generators (SVGs) are FACTS equipment introduced for active and reactive power flow control. They eliminate the need for zigzag transformers and give a fast response. However, with regard to their application for flicker reduction in using Electric Arc Furnace (EAF), the existing multilevel inverter-based SVGs suffer from the following disadvantages. (1) To control the reactive power, an off-line calculation of Modulation Index (MI) is required to adjust the SVG output voltage. This slows down the transient response to the changes of reactive power; and (2) Random active power exchange may cause unbalance to the voltage of the d.c. link (HBI) capacitor when the reactive power control is done by adjusting the power angle d alone. To resolve these problems, a mathematical model of 11-level cascaded SVG, was developed. A new control strategy involving both MI (modulation index) and power angle (d) is proposed. A selected harmonics elimination method (SHEM) is taken for switching pattern calculations. To shorten the response time and simplify the controls system, feed forward neural networks are used for on-line computation of the switching patterns instead of using look-up tables. The proposed controller updates the MI and switching patterns once each line-cycle according to the sampled reactive power Qs. Meanwhile, the remainder reactive power (compensated by the MI) and the reactive power variations during the line-cycle will be continuously compensated by adjusting the power angles, d. The scheme senses both variables MI and d, and takes action through the inverter switching angle, qi. As a result, the proposed SVG is expected to give a faster and more accurate response than present designs allow. In support of the proposal there is a mathematical model for reactive powered distribution and a sensitivity matrix for voltage regulation assessment, MATLAB simulation results are provided to validate the proposed schemes. The performance with non-linear time varying loads is analysed and refers to a general review of flicker, of methods for measuring flickers due to arc furnace and means for mitigation.
Resumo:
Reported are experimental results from investigations of the sensing properties of long-period gratings (LPGs) recorded in two different geometries of photonic crystal fibre (PCF): a large-mode area PCF and an endlessly single mode PCF. The LPGs have been characterised for their sensitivity to temperature, bending, surrounding index and strain. The LPGs in both fibres have been found to have negligible temperature sensitivity whilst exhibiting useful strain sensitivities. Strong directional bend sensitivity is shown by one PCF whilst the other shows good non-directional bend sensitivity. The fibres exhibit differing sensitivities to surrounding refractive index.
Resumo:
Sensing properties of long-period gratings (LPGs) fabricated in photonic crystal fibers by an electric arc are explained and quantified by semianalytical and numerical models. In particular, the grating's insensitivity to temperature and simultaneous sensitivity to strain and refractive index are simulated. The modeling procedure is generalized so that it can be applied to a wide range of LPGs in various fibers.
Resumo:
The problem of variation in weld crack susceptibility caused by small variations in alloy and impurity elements for the 70-30 cupro-nickel alloy has been investigated. Both wrought and cast versions of the alloy have been studied, the main techniques employed being the Varestraint test and weld thermal simulation. In the wrought alloys, cracking has been found to occur mainly in the weld metal, whilst in the cast alloys cracking is extensive in both weld metal and heat affected zone. The previously reported effects of certain impurities (P,S,Si) in increasing cracking have been confirmed, and it has also been shown that Ti and Zr may both have a crack promoting effect at levels commonly found in cupro-nickels, whilst C can interact with several of the other elements investigated to produce a beneficial effect. The testing carried out using the weld thermal simulator has shown that a relationship does exist between hot ductility and weld cracking. In particular, the absence of the peak in ductility in the range 1100°C-900°C on cooling from a temperature near to the solidus is indicative of a highly crack susceptible alloy. Principal practical implications of the investigation concern the relationship of weld metal cracking to alloy composition, especially the level of certain impurities. It would appear that the upper limits permitted by the alloy specifications are unrealistically high. The introduction of lower impurity limits would alleviate the current problems of variability in resistance to cracking during welding.
Resumo:
The aims of the work reported in this thesis are: (1) To investigate the application of a Wave Analysis Approach in the study of the acoustics of small rooms where the conditions for a Geometrical Statistical Analysis are not valid.
Resumo:
This thesis is concerned with the optimising of hearing protector selection. A computer model was used to estimate the reduction in noise exposure and risk of occupational deafness provided by the wearing of hearing protectors in industrial noise spectra. The model was used to show that low attenuation hearing protectors con provide greater protection than high attenuation protectors if the high attenuation protectors ore not worn for the total duration of noise exposure; or not used by a small proportion of the population. The model was also used to show that high attenuation protectors will not necessarily provide significantly greater reduction in risk than low attenuation protectors if the population has been exposed to the noise for many years prior to the provision of hearing protectors. The effects of earplugs and earmuffs on the localisation of sounds were studied to determine whether high attenuation earmuffs are likely to have greater potential than the lower attenuation earplugs for affecting personal safety. Laboratory studies and experiments at a foundry with normal-hearing office employees and noise-exposed foundrymen who had some experience of wearing hearing protectors showed that although earplugs reduced the ability of the wearer to determine the direction of warning sounds, earmuffs produced more total angular error and more confusions between left and right. !t is concluded from the research findings that the key to the selection of hearing protectors is to be found in the provision of hearing protectors that can be worn for a very high percentage of the exposure time by a high percentage of the exposed population with the minimum effect on the personal safety of the wearers - the attenuation provided by the protection should be adequate but not a maximum value.