963 resultados para Uniformity.
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Ultrasound is the term that describes the sound waves with higher frequencies than human hearing. Ultrasound used in medical diagnosis is a modality based on the use of sound energy and the acoustic properties of the various parts of the body to produce images of stationary and moving tissues. However, despite the ease of use and security that this modality offers for not using ionizing radiation, one should ensure the accuracy and optimum performance of the equipment, which results in precise diagnoses. To accomplish that, periodic quality control tests must be performed, which include: physical and mechanical inspection of the equipment, image uniformity, depth of penetration/visualization, accuracy of distances, axial and lateral resolution, dead zone and doppler sensitivity. This work intends to study a computerized method for calculating the depth of penetration of ultrasound, comparing it to the observerdependent method currently used. The images were collected during the quality control tests of ultrasound equipment. The results of the comparison between the visual and computerized methods were not conclusive for selecting the safest methodology for obtaining the depth of visualization
Resumo:
The signal-to-noise ratio and image uniformity analysis parameters are very important in quality control of an MRI scanner. They are measured in regular tests with phantoms. In these tests, however, used to quadrature coil, which has been most widely used clinically, and, therefore, was replaced in the procedures for body coil. In order to understand the difference between these two parameters in these coils, the study aimed to analyze the images acquired from four different phantoms in the same equipment under the same conditions for comparison purposes. With these results, it can be concluded that the body coil signal-to-noise ratio has always smaller than the quadrature in any projection, whereas the image uniformity is larger
Resumo:
Radiotherapy is a multidisciplinary speciality which uses complex equipment and radiation sources for delivery of treatment, using high-energy ionizing radiation to treat cancer at several stages of complexity. Since radiation therapy is a technique which involves a precalculated radiation dose, it shall be established quality assurance programs that provide an efficient and safety treatment. The International Commission on Radiation Units and Measurements (ICRU) report No. 50 has recommended dose uniformity between 5% of the prescribed dose throughout the region of interest. This is one of the most primordial points that justify the importance of a suitable attendance of the equipments quality and performance. For quality control, the medical physicist will be involved with establishing and running a Quality Control Program (QCP). He must adapt or develop the procedures of equipment acceptance and commissioning, besides verifying the use of principles and accepted protocols of national and international reports to assure the correct quality, quantity, and placement of radiation during the performance of a radiological procedure, establishing adequate protocols to ensure accurate patient dosimetry. This present work consists of a description of the activities carried through the Sectors of Radiation Therapy of the Hospital of Clinics of the Campinas State University (Unicamp), particularly in the implementation of the Quality Control Program
Resumo:
This study investigated the effect of slope and antecedent soil moisture on the water depth stored and percolated on extensive green roofs built in pilot scale. For this purpose, slopes of 10, 20 and 30% were investigated. Moisture was measured before and after each test to determine the differential moisture (ΔU). A rainfall simulator was designed and tested; the best arrangement presents a Christiansen Uniformity Coefficient of 56%. The results yielded that the slopes of 10% presented the highest values of water depth stored (59,88%), water depth percolated (77,15%), the slope of 30% presented the highest water depth drained (48,22%.) and there was no correlation between slope, water depth stored, water depth percolated and ΔU. It was verified the effect of dilution on the modules i10% between water depth percolated and apparent color (0.71%) in i20% between water depth drained and apparent color (-0.748%) and in the module i30% between water depth drained and turbidity (-0.76%) and water depth drained and apparent color (-0.93%). In i10% there was high correlation between pH and water depth percolated (0.94%) and between water depth drained and pH (0.71%). The data indicate that the module i10% had a greater reduction of runoff
Resumo:
The study analyzed contours of the thoracic region of patients undergoing radiotherapy of breast tumors in Hospital Manuel de Abreu of Bauru (institution 1) and the Hospital da Faculdade de Medicina of Botucatu (Institution 2). Were prepared isodose curves corresponding to the contours of the patient, which were presented for radiotherapists doctors both hospital services that enabled the choice of the curve isodose that provides the best distribution of radiation dose in the irradiated volume. Some boundaries were digitized in one institution and sent for preparation of isodose lines in the institution 2, both curves plotted in each of the institutions and for the same contour, were compared, showing that the methodology of Curves of distance is feasible and reliable, while optimizing the routine procedures regarding the handling of isodose plans provided by different radiation equipment. It compares the calculation of the exposure time determined using the isodose curve selected by calculating the value obtained considering the PDP at the point of the middle line of separation between the internal and external fields, the difference between the two methods for determining exposure time was around 2.4%. A study on the angle of the radiation beam at the input field (region breast-air) was conducted showing that, once known a tangent angle of the input beam, one can estimate the angle of the wedge filter used in some procedures for uniformity of dose within the irradiated volume compensation and the lack of tissue in the treatment volume. A comparative study between the isodose curves produced manually with the curves obtained in a two-dimensional computer system, the computer system showed that provides further information regarding the dose gradient within the irradiated volume, in addition to reducing the time spent in preparing the curves isodose
Resumo:
The Boron Neutron Capture Therapy (BNCT), based on the 10B(n,α)7Li reaction, represents a promising modality for the treatment of cancers that are resistents to conventional treatments. So, it is necessary to find drugs (boron compounds) with high selectivity for each type of cancer, the neutrons source should be well characterized and the rate of 10B(n,α)7Li reaction should be measured with great accuracy as possible. This study aimed to develop a method for manufacturing thin films of boron, for measure the 10B(n,α)7Li reaction, and analyze the uniformity of the films. Five thin films of boron were manufactured with three different concentrations of boric acid, heated to transform the acid in boron, irradiated with thermic neutrons coupled to CR-39 detectors, in BNCT line at the reactor IEA-R1 IPEN/CNEN, São Paulo. After the irradiation, the detectors were chemically attacked with NaOH to reveal the tracks. The methodology presented is effective because it resulted in deposition of boron as thin film enabling the quantitative analysis of 10B(n,α)7Li reaction. The analysis of the uniformity of density of the induced tracks in CR-39 shows that, in most of the films, there is no uniformity in surface distribution of boron, but when the film is divided, we obtain some uniform sectors
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Agronomia (Genética e Melhoramento de Plantas) - FCAV
Resumo:
Pós-graduação em Genética e Melhoramento Animal - FCAV
Resumo:
Avian salmonellosis and mycoplasmosis are infectious diseases that, in addition of causing lack of flock uniformity, represent a hazard to human health. The objective of the present study was to evaluate the seroprevalence of mycoplasmosis and salmonellosis in commercial broilers, backyard chickens, and spent hens slaughtered at a processing plant with local health inspection in Uberlandia, MG, Brazil. A total of 210 samples were randomly collected at the time of bleeding. Samples were submitted to rapid plate serum agglutination test (RSA) for the classification of Salmonella pullorum, Salmonella gallinarum, Mycoplasma gallisepticum and Mycoplasma synoviae. In order to increase result specificity, mycoplasmosis-positive samples were submitted to hemagglutination inhibition test (HI). No samples presented detectable antibodies against Salmonella pullorum or Salmonella gallinarum in the RSA test. Only Mycoplasma synoviae was detected in 14% of the backyard chickens and 0.74% in commercial broilers, whereas no antibodies were detected in spent hens. The seroprevalence rates found in the present study emphasize the need of keeping chicken flocks free from disease using effective biosafety systems.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)