846 resultados para Tracking errors
Resumo:
Studies have shown that the discriminability of successive time intervals depends on the presentation order of the standard (St) and the comparison (Co) stimuli. Also, this order affects the point of subjective equality. The first effect is here called the standard-position effect (SPE); the latter is known as the time-order error. In the present study, we investigated how these two effects vary across interval types and standard durations, using Hellström’s sensation-weighting model to describe the results and relate them to stimulus comparison mechanisms. In Experiment 1, four modes of interval presentation were used, factorially combining interval type (filled, empty) and sensory modality (auditory, visual). For each mode, two presentation orders (St–Co, Co–St) and two standard durations (100 ms, 1,000 ms) were used; half of the participants received correctness feedback, and half of them did not. The interstimulus interval was 900 ms. The SPEs were negative (i.e., a smaller difference limen for St–Co than for Co–St), except for the filled-auditory and empty-visual 100-ms standards, for which a positive effect was obtained. In Experiment 2, duration discrimination was investigated for filled auditory intervals with four standards between 100 and 1,000 ms, an interstimulus interval of 900 ms, and no feedback. Standard duration interacted with presentation order, here yielding SPEs that were negative for standards of 100 and 1,000 ms, but positive for 215 and 464 ms. Our findings indicate that the SPE can be positive as well as negative, depending on the interval type and standard duration, reflecting the relative weighting of the stimulus information, as is described by the sensation-weighting model.
Resumo:
Sentinel-5 (S5) and its precursor (S5P) are future European satellite missions aiming at global monitoring of methane (CH4) column-average dry air mole fractions (XCH4). The spectrometers to be deployed onboard the satellites record spectra of sunlight backscattered from the Earth's surface and atmosphere. In particular, they exploit CH4 absorption in the shortwave infrared spectral range around 1.65 mu m (S5 only) and 2.35 mu m (both S5 and S5P) wavelength. Given an accuracy goal of better than 2% for XCH4 to be delivered on regional scales, assessment and reduction of potential sources of systematic error such as spectroscopic uncertainties is crucial. Here, we investigate how spectroscopic errors propagate into retrieval errors on the global scale. To this end, absorption spectra of a ground-based Fourier transform spectrometer (FTS) operating at very high spectral resolution serve as estimate for the quality of the spectroscopic parameters. Feeding the FTS fitting residuals as a perturbation into a global ensemble of simulated S5- and S5P-like spectra at relatively low spectral resolution, XCH4 retrieval errors exceed 0.6% in large parts of the world and show systematic correlations on regional scales, calling for improved spectroscopic parameters.
Resumo:
This paper investigates the trends in inventory management in the automobile manufacturing industry during recessionary vs. non-recessionary periods. It is an empirical approach to testing the validity of the hypothesis that firms which carry leaner inventories perform better throughout the business cycle and are less affected by variability in the economy than less lean firms. The research also hopes to shed some light on how firm's financial statements can be manipulated through discretionary adjustments made by management pertaining to the valuation of inventories.
Resumo:
Coronary heart disease remains the leading cause of death in the United States and increased blood cholesterol level has been found to be a major risk factor with roots in childhood. Tracking of cholesterol, i.e., the tendency to maintain a particular cholesterol level relative to the rest of the population, and variability in blood lipid levels with increase in age have implications for cholesterol screening and assessment of lipid levels in children for possible prevention of further rise to prevent adulthood heart disease. In this study the pattern of change in plasma lipids, over time, and their tracking were investigated. Also, within-person variance and retest reliability defined as the square root of within-person variance for plasma total cholesterol, HDL-cholesterol, LDL-cholesterol, and triglycerides and their relation to age, sex and body mass index among participants from age 8 to 18 years were investigated. ^ In Project HeartBeat!, 678 healthy children aged 8, 11 and 14 years at baseline were enrolled and examined at 4-monthly intervals for up to 4 years. We examined the relationship between repeated observations by Pearson's correlations. Age- and sex-specific quintiles were calculated and the probability of participants to remain in the uppermost quintile of their respective distribution was evaluated with life table methods. Plasma total cholesterol, HDL-C and LDL-C at baseline were strongly and significantly correlated with measurements at subsequent visits across the sex and age groups. Plasma triglyceride at baseline was also significantly correlated with subsequent measurements but less strongly than was the case for other plasma lipids. The probability to remain in the upper quintile was also high (60 to 70%) for plasma total cholesterol, HDL-C and LDL-C. ^ We used a mixed longitudinal, or synthetic cohort design with continuous observations from age 8 to 18 years to estimate within person variance of plasma total cholesterol, HDL-C, LDL-C and triglycerides. A total of 5809 measurements were available for both cholesterol and triglycerides. A multilevel linear model was used. Within-person variance among repeated measures over up to four years of follow-up was estimated for total cholesterol, HDL-C, LDL-C and triglycerides separately. The relationship of within-person and inter-individual variance with age, sex, and body mass index was evaluated. Likelihood ratio tests were conducted by calculating the deviation of −2log (likelihood) within the basic model and alternative models. The square root of within-person variance provided the retest reliability (within person standard deviation) for plasma total cholesterol, HDL-C, LDL-C and triglycerides. We found 13.6 percent retest reliability for plasma cholesterol, 6.1 percent for HDL-cholesterol, 11.9 percent for LDL-cholesterol and 32.4 percent for triglycerides. Retest reliability of plasma lipids was significantly related with age and body mass index. It increased with increase in body mass index and age. These findings have implications for screening guidelines, as participants in the uppermost quintile tended to maintain their status in each of the age groups during a four-year follow-up. The magnitude of within-person variability of plasma lipids influences the ability to classify children into risk categories recommended by the National Cholesterol Education Program. ^
Resumo:
Height of instrument (HI) blunders in GPS measurements cause position errors. These errors can be pure vertical, pure horizontal, or a mixture of both. There are different error regimes depending on whether both the base and the rover both have HI blunders, if just the base has an HI blunder, or just the rover has an HI blunder. The resulting errors are on the order of 30 cm for receiver separations of 1000 km for an HI blunder of 2 m. Given the complicated nature of the errors, we believe it would be difficult, if not impossible, to detect such errors by visual inspection. This serves to underline the necessity to enter GPS HI's correctly.
Resumo:
Height of instrument (HI) blunders in GPS measurements cause position errors. These errors can be pure vertical, pure horizontal, or a mixture of both. There are different error regimes depending on whether both the base and the rover both have HI blunders, if just the base has an HI blunder, or just the rover has an HI blunder. The resulting errors are on the order of 30 cm for receiver separations of 1000 km for an HI blunder of 2 m. Given the complicated nature of the errors, we believe it would be difficult, if not impossible, to detect such errors by visual inspection. This serves to underline the necessity to enter GPS HIs correctly.
Resumo:
Medication errors, one of the most frequent types of medical errors, are a common cause of patient harm in hospital systems today. Nurses at the bedside are in a position to encounter many of these errors since they are there at the start of the process (ordering/prescribing) and the end of the process (administration). One of the recommendations from the IOM (Institute of Medicine) report, "To Err is Human," was for organizations to identify and learn from medical errors through event reporting systems. While many organizations have reporting systems in place, research studies report a significant amount of underreporting by nurses. A systematic review of the literature was performed to identify contributing factors related to the reporting and not reporting of medication errors by nurses at the bedside.^ Articles included in the literature review were primary or secondary studies, dated January 1, 2000 – July 2009, related to nursing medication error reporting. All 634 articles were reviewed with an algorithm developed to standardize the review process and help filter out those that did not meet the study criteria. In addition, 142 article bibliographies were reviewed to find additional studies that were not found in the original literature search.^ After reviewing the 634 articles and the additional 108 articles discovered in the bibliography review, 41 articles met the study criteria and were used in the systematic literature review results.^ Fear of punitive reactions to medication errors was a frequent barrier to error reporting. Nurses fear reactions from their leadership, peers, patients and their families, nursing boards, and the media. Anonymous reporting systems and departments/organizations with a strong safety culture in place helped to encourage the reporting of medication errors by nursing staff.^ Many of the studies included in this literature review do not allow results that can be generalized. The majority of them took place in single institutions/organizations with limited sample sizes. Stronger studies with larger sample sizes need to be performed, utilizing data collection methods that have been validated, to determine stronger correlations between safety cultures and nurse error reporting.^
Resumo:
A large number of ridge regression estimators have been proposed and used with little knowledge of their true distributions. Because of this lack of knowledge, these estimators cannot be used to test hypotheses or to form confidence intervals.^ This paper presents a basic technique for deriving the exact distribution functions for a class of generalized ridge estimators. The technique is applied to five prominent generalized ridge estimators. Graphs of the resulting distribution functions are presented. The actual behavior of these estimators is found to be considerably different than the behavior which is generally assumed for ridge estimators.^ This paper also uses the derived distributions to examine the mean squared error properties of the estimators. A technique for developing confidence intervals based on the generalized ridge estimators is also presented. ^
Resumo:
Errors in the administration of medication represent a significant loss of medical resources and pose life altering or life threatening risks to patients. This paper considered the question, what impact do Computerized Physician Order Entry (CPOE) systems have on medication errors in the hospital inpatient environment? Previous reviews have examined evidence of the impact of CPOE on medication errors, but have come to ambiguous conclusions as to the impact of CPOE and decision support systems (DSS). Forty-three papers were identified. Thirty-one demonstrated a significant reduction in prescribing error rates for all or some drug types; decreases in minor errors were most often reported. Several studies reported increases in the rate of duplicate orders and failures to remove contraindicated drugs, often attributed to inappropriate design or to an inability to operate the system properly. The evidence on the effectiveness of CPOE to reduce errors in medication administration is compelling though it is limited by modest study sample sizes and designs. ^
Resumo:
Next-generation sequencing (NGS) technology has become a prominent tool in biological and biomedical research. However, NGS data analysis, such as de novo assembly, mapping and variants detection is far from maturity, and the high sequencing error-rate is one of the major problems. . To minimize the impact of sequencing errors, we developed a highly robust and efficient method, MTM, to correct the errors in NGS reads. We demonstrated the effectiveness of MTM on both single-cell data with highly non-uniform coverage and normal data with uniformly high coverage, reflecting that MTM’s performance does not rely on the coverage of the sequencing reads. MTM was also compared with Hammer and Quake, the best methods for correcting non-uniform and uniform data respectively. For non-uniform data, MTM outperformed both Hammer and Quake. For uniform data, MTM showed better performance than Quake and comparable results to Hammer. By making better error correction with MTM, the quality of downstream analysis, such as mapping and SNP detection, was improved. SNP calling is a major application of NGS technologies. However, the existence of sequencing errors complicates this process, especially for the low coverage (
Resumo:
Over the last decade, adverse events and medical errors have become a main focus of interest for the standards of quality and safety in the U.S. healthcare system (Weinstein & Henderson, 2009). Particularly when a medical error occurs, the disclosure of medical errors and its practices have become a focal point of the healthcare process. Patients and family members who have experienced a medical error might be able to provide knowledge and insight on how to improve the disclose process. However, patient and family member are not typically involved in the disclosure process, thus their experiences go unnoticed. ^ The purpose of this research was to explore how best to include patients and family members in the disclosure process regarding a medical error. The research consisted of 28 qualitative interviews from three stakeholder groups: Hospital Administrators, Clinical Service Providers, and Patients and Family Members. They were asked for their ideas and suggestions on how best to include patients and family members in the disclosure process. Framework Analysis was used to analyze this data and find prevalent themes based on the primary research question. A secondary aim was to index categories created based on the interviews that were collected. Data was used from the Texas Disclosure and Compensation Study with Dr. Eric Thomas as the Principal Investigator. Full acknowledgement of access to this data is given to Dr. Thomas. ^ The themes from the research revealed that each stakeholder group was interested and open to including patients and family members in the disclosure process and that the disclosure process should not be a "one-way" avenue. The themes gave many suggestions regarding how to best include patients and family members in the disclosure process of a medical error. Secondary aims revealed several ways to assess the ideas and suggestion given by the stakeholders. Overall, acceptability of getting the perspective of patients and family members was the most common theme. Comparison of each stakeholder group revealed that including patients and family members would be beneficial to improving hospital disclosure practices. ^ Conclusions included a list of recommendations and measureable appropriate strategies that could provide hospital with key stakeholders insights on how to improve their disclosure process. Sharing patients and family members experience with healthcare providers can encourage a shift in culture where patients are valued and active in participating in hospital practices. To my knowledge, this research is the very first of its kind and moves the disclosure process conversation forward in a patient-family member inclusion direction that will assist in improving disclosure practices. Future research should implement and evaluate the success of the various inclusion strategies.^
Resumo:
Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some patients with Hodgkin lymphoma, carbon-ion therapy would reduce the predicted risk of second cancer incidence in the breast compared with proton therapy. The purpose of this work was to determine whether 4D-optimized carbon-ion therapy would significantly reduce the predicted risk of radiation induced second cancers in the breast for female Hodgkin lymphoma patients while preserving tumor control compared with proton therapy. To achieve our goals, we first investigated whether 4D-optimized carbon beam tracking could reduce dose to volumes outside a moving target compared with 3D-optimized carbon beam tracking while preserving target dose coverage. To understand the reliability of scanned carbon beam tracking, we studied the robustness of dose distributions in thoracic targets to uncertainties in patient motion. Finally, we investigated whether using carbon-ion therapy instead of proton therapy would significantly reduce the predicted risk of second cancer in the breast for a sample of Hodgkin lymphoma patients. We found that 4D-optimized ion beam tracking therapy can reduce the maximum dose to critical structures near a moving target by as much as 53%, compared to 3D-optimized ion beam tracking therapy. We validated these findings experimentally using a scanned carbon ion synchrotron and a motion phantom. We found scanned carbon beam tracking to be sensitive to a number of motion uncertainties, most notably phase delays in tracking, systematic spatial errors, and interfractional motion changes. Our findings indicate that a lower risk of second cancer in the breast might be expected for some Hodgkin lymphoma patients using carbon-ion therapy instead of proton therapy. For our reference scenario, we found the ratio of risk to be 0.77 ± 0.35 for radiogenic breast cancer after carbon-ion therapy versus proton therapy. Our findings were dependent on the RBE values for tumor induction and the radiosensitivity of breast tissue, as well as the physical dose distribution.