990 resultados para Spectroscopy measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic-inorganic hybrid (OIH) sol-gel coatings based on ureasilicates (U(X)) have promising properties for use as eco-friendly coatings on hot dip galvanized steel (HDGS) and may be considered potential substitutes for pre-treatment systems containing Cr(VI). These OIH coatings reduce corrosion activity during the initial stages of contact of the HDGS samples with highly alkaline environments (cementitious media) and allow the mitigation of harmful effects of an initial excessive reaction between cement pastes and the zinc layer. However, the behavior of HDGS coated with U(X) in the presence of chloride ions has never been reported. In this paper, the performance of HDGS coated with five different U(X) coatings was assessed by electrochemical measurements in chloride-contaminated simulated concrete pore solution (SCPS). U(X) sol-gel coatings were produced and deposited on HDGS by a dip coating method. The coatings performance was evaluated by electrochemical impedance spectroscopy, potentiodynamic polarization curves measurements, macrocell current density and polarization resistance in contact with chloride-contaminated SCPS. The SEM/EDS analyses of the coatings before and after the tests were also performed. The results showed that the HDGS samples coated with the OIH coatings exhibited enhanced corrosion resistance to chloride ions when compared to uncoated galvanized steel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A measurement of the inclusive cross section for top quark pair production in pp collisions using events with an isolated lepton (muon or electron) and a τ lepton decaying to hadrons (τhad) is reported. Measurements of the branching ratios of top quark decays into leptons and jets using events with tt¯ (top antitop) pairs are also reported. Events were recorded with the ATLAS detector at the LHC in pp collisions at a center-of-mass energy of 7 TeV. The collected data sample corresponds to an integrated luminosity of 4.6 fb−1. The inclusive cross section measured using events with an isolated lepton and a τhad is σtt¯=183±9(stat.)±23(syst.)±3(lumi.)pb. The measured top quark branching ratios agree with the Standard Model predictions within the measurement uncertainties of a few percent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado (Programa Doutoral em Informática)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ag and AgxO thin films were deposited by non-reactive and reactive pulsed DC magnetron sputtering, respectively, with the final propose of functionalizing the SS316L substrate with antibacterial properties. The coatings were characterized chemically, physically and structurally. The coatings nanostructure was assessed by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), while the coatings morphology was determined by scanning electron microscopy (SEM). The XRD and XPS analyses suggested that Ag thin film is composed by metallic Ag, which crystallizes in fcc-Ag phase, while the AgxO thin film showed both metallic Ag and Ag-O bonds, which crystalize in fcc-Ag and silver oxide phases. The SEM results revealed that Ag thin film formed a continuous layer, while AgxO layer was composed of islands with hundreds of nanometers surrounded by small nanoparticles with tens of nanometers. The surface wettability and surface tension parameters were determined by contact angle measurements, being found that Ag and AgxO surfaces showed very similar behavior, with all the surfaces showing a hydrophobic character. In order to verify the antibacterial behavior of the coatings, halo inhibition zone tests were realized for Staphylococcus epidermidis and Staphylococcus aureus. Ag coatings did not show antibacterial behavior, contrarily to AgxO coating, which presented antibacterial properties against the studied bacteria. The presence of silver oxide phase along with the development of different morphology were pointed as the main factors in the origin of the antibacterial effect found in AgxO thin film. The present study demonstrated that AgxO coating presented antibacterial behavior and its application in cardiovascular stents is promising.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Curcumin and caffeine (used as lipophilic and hydrophilic model compounds, respectively) were successfully encapsulated in lactoferrin-glycomacropeptide (Lf-GMP) nanohydrogels by thermal gelation showing high encapsulation efficiencies (>90 %). FTIR spectroscopy confirmed the encapsulation of bioactive compounds in Lf-GMP nanohydrogels and revealed that according to the encapsulated compound different interactions occur with the nanohydrogel matrix. The successful encapsulation of bioactive compounds in Lf-GMP nanohydrogels was also confirmed by fluorescence measurements and confocal laser scanning microscopy. TEM images showed that loaded nanohydrogels maintain their spherical shape with sizes of 112 and 126 nm for curcumin and caffeine encapsulated in Lf-GMP nanohydrogels, respectively; in both cases a polydispersity of 0.2 was obtained. The release mechanisms of bioactive compounds through Lf-GMP nanohydrogels were evaluated at pH 2 and pH 7, by fitting the Linear Superimposition Model to the experimental data. The bioactive compounds release was found to be pH-dependent: at pH 2, relaxation is the governing phenomenon for curcumin and caffeine compounds and at pH 7 Ficks diffusion is the main mechanism of caffeine release while curcumin was not released through Lf-GMP nanohydrogels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chitosan coating was applied in Lactoferrin (Lf)-Glycomacropeptide (GMP) nanohydrogels by layer-by-layer coating process. A volume ratio of 0.1 of Lf-GMP nanohydrogels (0.2 mg.mL-1, at pH 5.0) to chitosan (1 mg.mL-1, at pH 3) demonstrated to be the optimal condition to obtain stable nanohydrogels with size of 230 ± 12 nm, a PdI of 0.22 ± 0.02 and a -potential of 30.0 ± 0.15 mV. Transmission electron microscopy (TEM) images showed that the application of chitosan coating in Lf-GMP did not affect the spherical shape of nanohydrogels and confirmed the low aggregation of nanohydrogels in solution. The analysis of chemical interactions between chitosan and Lf-GMP nanohydrogels were performed by Fourier transform infrared spectroscopy (FTIR) and by circular dichroism (CD) that revealed that a specific chemical interaction occurring between functional groups of protein-based nanohydrogels and active groups of the chitosan was established. The effect of chitosan coating on release mechanisms of Lf-GMP nanohydrogels at acid conditions (pH 2, 37 ºC) was evaluated by the encapsulation of a model compound (caffeine) in these systems. Linear Superposition Model was used to fit the experimental data and revealed that Fick and relaxation mechanisms are involved in caffeine release. It was also observed that the Fick contribution increase with the application of chitosan coating. In vitro gastric digestion was performed with Lf-GMP nanohydrogels and Lf-GMP nanohydrogels with chitosan coating and it was observed that the presence of chitosan improve the stability of Lf and GMP (proteins were hydrolysed at a slower rate and were present in solution by longer time). Native electrophoreses revealed that the nanohydrogels without coating remained intact in solution until 15 min and with chitosan coating remained intact until 60 min, during gastric digestion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe echocardiographic measurements and left ventricular mass in a population sample of healthy adults inhabitants of the urban region of Porto Alegre. METHODS: An analytical, observational, population-based, cross-sectional study was done. Through a multi-stage probability sample, 114 individuals were selected to be submitted to a M-mode and two-dimensional echocardiogram with color Doppler. The analyses were restricted to healthy participants. Echocardiographic measurements were described by mean, standard deviation, 95 percentile and 95% confidence limits. RESULTS: A total of 100 healthy participants, with several characteristics similar to those from the original population, had a complete and reliable echocardiographic examination. The measurements of aorta, left atrium, interventricular septum, left ventricle in systole and diastole, left posterior wall and left ventricular mass, adjusted or not for body surface area or height, were significantly higher in males. The right ventricle size was similar among the genders. Several echocardiographic measurements were within standard normal limits. Interventricular septum, left posterior wall and left ventricular mass, adjusted or not for anthropometric measurements, and aortic dimensions had lower mean and range than the reference limits. CONCLUSION: The means and estimates of distribution for the measurements of interventricular septum, left posterior wall and left ventricular mass found in this survey were lower than those indicated by the international literature and accepted as normal limits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Excerpt] In this work, different multilayer structures, using a polyhydroxybutyrate-co-valerate film with a valerate content of 8% (PHBV8) as support, were developed aiming the development of active bio-based multilayer systems. An interlayer based on zein nanofibers with and without cinnamaldehyde were electrospun in the PHBV8 film and three multilayer systems were developed: 1) without an outer layer; 2) using a PHBV8 film as outer layer; and 3) using an alginate-based film as outer layer. Their physico-chemical properties were evaluated through: water vapour and oxygen permeabilities and colour measurements, Fourier Transform Infrared Spectroscopy (FTIR) and thermal analyses. Results showed that the presence of different outer layers affected the water vapour permeability and transparency of the multilayer films. (...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La idea principal del proyecto abarca el estudio de parámetros y fenómenos físicos. Los avances logrados se aplicarán al desarrollo de software y metodologías para cuantificación de materiales mediante microanálisis con sonda de electrones y microscopía electrónica de barrido. El microanálisis no es una técnica absoluta, sino que requiere de estándares de referencia, para obviar el uso de ciertos parámetros geométricos y atómicos difíciles de conocer con una precisión adecuada. Para contar con un método sin estándares debe abordarse la determinación de parámetros atómicos e instrumentales, que es uno de los aspectos que se desea encarar en este proyecto. Por otro lado, también se pretende incluir los parámetros estudiados en un software de cuantificación desarrollado por integrantes del proyecto. Otro de los propósitos del plan de trabajo es estudiar la potencialidad de la resolución espacial de una microsonda de electrones con el fin de desarrollar una metodología para caracterizar interfases, bordes de granos e inclusiones, con resolución submicrométrica, ya que los métodos tradicionales de cuantificación se restringen al caso de muestras planas y homogéneas dentro del volumen de interacción, pero la caracterización de inhomogeneidades a nivel micrométrico no ha sido desarrollada todavía, salvo algunas excepciones. The main idea of this project involves the study of physical parameters and phenomena. The concretion of the different goals will permit the elaboration of softeare and methodologies for materials characterization by means of electron probe microanalysis and scanning microscopy. Electron probe microanalysis is not an absolute technique, but requires reference standards in order not to involve certain geometrical and atomic parameters for which high uncertainties cannot be avoided. In order to have standardless method, the determination of atomic and instrumental parameters must be accomplished, as will be faced through this project. Complementary, the parameters studied will be included in a quantification software developed in our research group of FaMAF. Another objective of this activity plan is to study the spatial resolution potentiality of a focalized electron beam, with the aim of characterizing interphases, grain boundaries and inclusions with submicron sensitivity, since the traditional quantification procedures are restricted to flat homogeneous samples, whereas the characterization of inhomogeneities has not been developed yet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ground-based measurements of the parameters of atmosphere in Tbilisi during the same period, which are provided by the Mikheil Nodia Institute of geophysics, were used as calibration data. Satellite data monthly averaging, preprocessing, analysis and visualization was performed using Giovanni web-based application. Maps of trends and periodic components of the atmosphere aerosol optical thickness and ozone concentration over the study area were calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM). Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM) as gold-standard and measurements taken before morning micturition (BM) and in the afternoon (AM), for the best diagnosis of systemic arterial hypertension (SAH), and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women) were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM); and with post-morning-micturition and evening measurements (PM+EM). All patients underwent echocardiography (for left ventricular hypertrophy - LVH) and urinary albumin measurement (for microalbuminuria - MAU). Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM) and (PM+EM), and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM) versus (PM+EM) were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM) and (PM+EM) were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Numerous studies show the benefits of exercise training after myocardial infarction (MI). Nevertheless, the effects on function and remodeling are still controversial. Objectives: To evaluate, in patients after (MI), the effects of aerobic exercise of moderate intensity on ventricular remodeling by cardiac magnetic resonance imaging (CMR). Methods: 26 male patients, 52.9 ± 7.9 years, after a first MI, were assigned to groups: trained group (TG), 18; and control group (CG), 8. The TG performed supervised aerobic exercise on treadmill twice a week, and unsupervised sessions on 2 additional days per week, for at least 3 months. Laboratory tests, anthropometric measurements, resting heart rate (HR), exercise test, and CMR were conducted at baseline and follow-up. Results: The TG showed a 10.8% reduction in fasting blood glucose (p = 0.01), and a 7.3-bpm reduction in resting HR in both sitting and supine positions (p < 0.0001). There was an increase in oxygen uptake only in the TG (35.4 ± 8.1 to 49.1 ± 9.6 mL/kg/min, p < 0.0001). There was a statistically significant decrease in the TG left ventricular mass (LVmass) (128.7 ± 38.9 to 117.2 ± 27.2 g, p = 0.0032). There were no statistically significant changes in the values of left ventricular end-diastolic volume (LVEDV) and ejection fraction in the groups. The LVmass/EDV ratio demonstrated a statistically significant positive remodeling in the TG (p = 0.015). Conclusions: Aerobic exercise of moderate intensity improved physical capacity and other cardiovascular variables. A positive remodeling was identified in the TG, where a left ventricular diastolic dimension increase was associated with LVmass reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2014