903 resultados para Signal interference


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present thesis, a new methodology of diagnosis based on advanced use of time-frequency technique analysis is presented. More precisely, a new fault index that allows tracking individual fault components in a single frequency band is defined. More in detail, a frequency sliding is applied to the signals being analyzed (currents, voltages, vibration signals), so that each single fault frequency component is shifted into a prefixed single frequency band. Then, the discrete Wavelet Transform is applied to the resulting signal to extract the fault signature in the frequency band that has been chosen. Once the state of the machine has been qualitatively diagnosed, a quantitative evaluation of the fault degree is necessary. For this purpose, a fault index based on the energy calculation of approximation and/or detail signals resulting from wavelet decomposition has been introduced to quantify the fault extend. The main advantages of the developed new method over existing Diagnosis techniques are the following: - Capability of monitoring the fault evolution continuously over time under any transient operating condition; - Speed/slip measurement or estimation is not required; - Higher accuracy in filtering frequency components around the fundamental in case of rotor faults; - Reduction in the likelihood of false indications by avoiding confusion with other fault harmonics (the contribution of the most relevant fault frequency components under speed-varying conditions are clamped in a single frequency band); - Low memory requirement due to low sampling frequency; - Reduction in the latency of time processing (no requirement of repeated sampling operation).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis collects the outcomes of a Ph.D. course in Telecommunications engineering and it is focused on enabling techniques for Spread Spectrum (SS) navigation and communication satellite systems. It provides innovations for both interference management and code synchronization techniques. These two aspects are critical for modern navigation and communication systems and constitute the common denominator of the work. The thesis is organized in two parts: the former deals with interference management. We have proposed a novel technique for the enhancement of the sensitivity level of an advanced interference detection and localization system operating in the Global Navigation Satellite System (GNSS) bands, which allows the identification of interfering signals received with power even lower than the GNSS signals. Moreover, we have introduced an effective cancellation technique for signals transmitted by jammers, exploiting their repetitive characteristics, which strongly reduces the interference level at the receiver. The second part, deals with code synchronization. More in detail, we have designed the code synchronization circuit for a Telemetry, Tracking and Control system operating during the Launch and Early Orbit Phase; the proposed solution allows to cope with the very large frequency uncertainty and dynamics characterizing this scenario, and performs the estimation of the code epoch, of the carrier frequency and of the carrier frequency variation rate. Furthermore, considering a generic pair of circuits performing code acquisition, we have proposed a comprehensive framework for the design and the analysis of the optimal cooperation procedure, which minimizes the time required to accomplish synchronization. The study results particularly interesting since it enables the reduction of the code acquisition time without increasing the computational complexity. Finally, considering a network of collaborating navigation receivers, we have proposed an innovative cooperative code acquisition scheme, which allows exploit the shared code epoch information between neighbor nodes, according to the Peer-to-Peer paradigm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of the integrity of structural components is of great importance for aerospace systems, land and marine transportation, civil infrastructures and other biological and mechanical applications. Guided waves (GWs) based inspections are an attractive mean for structural health monitoring. In this thesis, the study and development of techniques for GW ultrasound signal analysis and compression in the context of non-destructive testing of structures will be presented. In guided wave inspections, it is necessary to address the problem of the dispersion compensation. A signal processing approach based on frequency warping was adopted. Such operator maps the frequencies axis through a function derived by the group velocity of the test material and it is used to remove the dependence on the travelled distance from the acquired signals. Such processing strategy was fruitfully applied for impact location and damage localization tasks in composite and aluminum panels. It has been shown that, basing on this processing tool, low power embedded system for GW structural monitoring can be implemented. Finally, a new procedure based on Compressive Sensing has been developed and applied for data reduction. Such procedure has also a beneficial effect in enhancing the accuracy of structural defects localization. This algorithm uses the convolutive model of the propagation of ultrasonic guided waves which takes advantage of a sparse signal representation in the warped frequency domain. The recovery from the compressed samples is based on an alternating minimization procedure which achieves both an accurate reconstruction of the ultrasonic signal and a precise estimation of waves time of flight. Such information is used to feed hyperbolic or elliptic localization procedures, for accurate impact or damage localization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis reports on the experimental realization, characterization and application of a novel microresonator design. The so-called “bottle microresonator” sustains whispering-gallery modes in which light fields are confined near the surface of the micron-sized silica structure by continuous total internal reflection. While whispering-gallery mode resonators in general exhibit outstanding properties in terms of both temporal and spatial confinement of light fields, their monolithic design makes tuning of their resonance frequency difficult. This impedes their use, e.g., in cavity quantum electrodynamics (CQED) experiments, which investigate the interaction of single quantum mechanical emitters of predetermined resonance frequency with a cavity mode. In contrast, the highly prolate shape of the bottle microresonators gives rise to a customizable mode structure, enabling full tunability. The thesis is organized as follows: In chapter I, I give a brief overview of different types of optical microresonators. Important quantities, such as the quality factor Q and the mode volume V, which characterize the temporal and spatial confinement of the light field are introduced. In chapter II, a wave equation calculation of the modes of a bottle microresonator is presented. The intensity distribution of different bottle modes is derived and their mode volume is calculated. A brief description of light propagation in ultra-thin optical fibers, which are used to couple light into and out of bottle modes, is given as well. The chapter concludes with a presentation of the fabrication techniques of both structures. Chapter III presents experimental results on highly efficient, nearly lossless coupling of light into bottle modes as well as their spatial and spectral characterization. Ultra-high intrinsic quality factors exceeding 360 million as well as full tunability are demonstrated. In chapter IV, the bottle microresonator in add-drop configuration, i.e., with two ultra-thin fibers coupled to one bottle mode, is discussed. The highly efficient, nearly lossless coupling characteristics of each fiber combined with the resonator's high intrinsic quality factor, enable resonant power transfers between both fibers with efficiencies exceeding 90%. Moreover, the favorable ratio of absorption and the nonlinear refractive index of silica yields optical Kerr bistability at record low powers on the order of 50 µW. Combined with the add-drop configuration, this allows one to route optical signals between the outputs of both ultra-thin fibers, simply by varying the input power, thereby enabling applications in all-optical signal processing. Finally, in chapter V, I discuss the potential of the bottle microresonator for CQED experiments with single atoms. Its Q/V-ratio, which determines the ratio of the atom-cavity coupling rate to the dissipative rates of the subsystems, aligns with the values obtained for state-of-the-art CQED microresonators. In combination with its full tunability and the possibility of highly efficient light transfer to and from the bottle mode, this makes the bottle microresonator a unique tool for quantum optics applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monoclonal antibodies have emerged as one of the most promising therapeutics in oncology over the last decades. The generation of fully human tumorantigen-specific antibodies suitable for anti-tumor therapy is laborious and difficult to achieve. Autoreactive B cells expressing those antibodies are detectable in cancer patients and represent a suitable source for human antibodies. However, the isolation and cultivation of this cell type is challenging. A novel method was established to identify antigen-specific B cells. The method is based on the conversion of the antigen independent CD40 signal into an antigen-specific one. For that, the artificial fusion proteins ABCos1 and ABCos2 (Antigen-specific B cell co-stimulator) were generated, which consist of an extracellular association-domain derived from the constant region of the human immunoglobulin (Ig) G1, a transmembrane fragment and an intracellular signal transducer domain derived of the cytoplasmic domain of the human CD40 receptor. By the association with endogenous Ig molecules the heterodimeric complex allows the antigen-specific stimulation of both the BCR and CD40. In this work the ability of the ABCos constructs to associate with endogenous IgG molecules was shown. Moreover, crosslinking of ABCos stimulates the activation of NF-κB in HEK293-lucNifty and induces proliferation in B cells. The stimulation of ABCos in transfected B cells results in an activation pattern different from that induced by the conventional CD40 signal. ABCos activated B cells show a mainly IgG isotype specific activation of memory B cells and are characterized by high proliferation and the differentiation into plasma cells. To validate the approach a model system was conducted: B cells were transfected with IVT-RNA encoding for anti-Plac1 B cell receptor (antigen-specific BCR), ABCos or both. The stimulation with the BCR specific Plac1 peptide induces proliferation only in the cotransfected B cell population. Moreover, we tested the method in human IgG+ memory B cells from CMV infected blood donors, in which the stimulation of ABCos transfected B cells with a CMV peptide induces antigen-specific expansion. These findings show that challenging ABCos transfected B cells with a specific antigen results in the activation and expansion of antigen-specific B cells and not only allows the identification but also cultivation of these B cells. The described method will help to identify antigen-specific B cells and can be used to characterize (tumor) autoantigen-specific B cells and allows the generation of fully human antibodies that can be used as diagnostic tool as well as in cancer therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die Erzeugung von Elektronenstrahlen hoher Intensität (I$geq$2,mA) und hoher Spinpolarisation (P$geq$85%) ist für die Experimente an den geplanten glqq Linac Ringgrqq Electron--Ion--Collidern (z.B. eRHIC am Brookhaven National Laboratory) unabdingbar, stellt aber zugleich eine enorme Herausforderung dar. Die Photoemission aus ce{GaAs}--basierten Halbleitern wie z.B. den in dieser Arbeit untersuchten GaAlAs/InGaAlAs Quanten--Übergittern zeichnet sich zwar durch eine hohe Brillanz aus, die geringe Quantenausbeute von nur ca. 1% im Bereich maximaler Polarisation erfordert jedoch hohe Laserintensitäten von mehreren Watt pro $text{cm}^{2}$, was erhebliche thermische Probleme verursacht. rnrnIn dieser Arbeit konnte zunächst gezeigt werden, dass die Lebensdauer einer Photokathode mit steigender Laserleistung bzw. Temperatur exponentiell abnimmt. Durch Einbringen eines DBR--Spiegels zwischen die aktive Zone der Photokathode und ihr Substrat wird ein Großteil des ungenutzten Laserlichts wieder aus dem Kristall herausreflektiert und trägt somit nicht zur Erwärmung bei. Gleichzeitig bildet der Spiegel zusammen mit der Grenzfläche zum Vakuum eine Resonator--Struktur aus, die die aktive Zone umschließt. Dadurch kommt es für bestimmte Wellenlängen zu konstruktiver Interferenz und die Absorption in der aktiven Zone erhöht sich. Beide Effekte konnten durch vergleichenden Messungen an Kathoden mit und ohne DBR--Spiegel nachgewiesen werden. Dabei ergibt sich eine gute Übereinstimmung mit der Vorhersage eines Modells, das auf der dielektrischen Funktion der einzelnen Halbleiterstrukturen beruht. Von besonderer praktischer Bedeutung ist, dass die DBR--Kathode für einen gegebenen Photoemissions-strom eine um einen Faktor $geq$,3{,}5 kleinere Erwärmung aufweist. Dies gilt über den gesamten Wellenlängenbereich in dem die Kathode eine hohe Strahlpolarisation (P$>$80%) produzieren kann, auch im Bereich der Resonanz.rnAus zeitaufgelösten Messungen der Ladungsverteilung und Polarisation lassen sich sowohl Rückschlüsse über die Transportmechanismen im Inneren einer Kathode als auch über die Beschaffenheit ihrer Oberfläche ziehen. Im Rahmen dieser Dissertation konnte die Messgeschwindigkeit der verwendeten Apparatur durch den Einbau eines schnelleren Detektors und durch eine Automatisierung der Messprozedur entscheidend vergrößert und die resultierende Zeitauflösung mit jetzt 1{,}2 Pikosekunden annähernd verdoppelt werden.rnrnDie mit diesen Verbesserungen erhaltenen Ergebnisse zeigen, dass sich der Transport der Elektronen in Superlattice--Strukturen stark vom Transport in den bisher untersuchten Bulk--Kristallen unterscheidet. Der Charakter der Bewegung folgt nicht dem Diffusionsmodell, sondern gibt Hinweise auf lokalisierte Zustände, die nahe der Leitungsbandunterkante liegen und Elektronen für kurze Zeit einfangen können. Dadurch hat die Impulsantwort einer Kathode neben einem schnellen Abfall des Signals auch eine größere Zeitkonstante, die selbst nach 30,ps noch ein Signal in der Größenordnung von ca. 5textperthousand der Maximalintensität erzeugt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biosensors find wide application in clinical diagnostics, bioprocess control and environmental monitoring. They should not only show high specificity and reproducibility but also a high sensitivity and stability of the signal. Therefore, I introduce a novel sensor technology based on plasmonic nanoparticles which overcomes both of these limitations. Plasmonic nanoparticles exhibit strong absorption and scattering in the visible and near-infrared spectral range. The plasmon resonance, the collective coherent oscillation mode of the conduction band electrons against the positively charged ionic lattice, is sensitive to the local environment of the particle. I monitor these changes in the resonance wavelength by a new dark-field spectroscopy technique. Due to a strong light source and a highly sensitive detector a temporal resolution in the microsecond regime is possible in combination with a high spectral stability. This opens a window to investigate dynamics on the molecular level and to gain knowledge about fundamental biological processes.rnFirst, I investigate adsorption at the non-equilibrium as well as at the equilibrium state. I show the temporal evolution of single adsorption events of fibrinogen on the surface of the sensor on a millisecond timescale. Fibrinogen is a blood plasma protein with a unique shape that plays a central role in blood coagulation and is always involved in cell-biomaterial interactions. Further, I monitor equilibrium coverage fluctuations of sodium dodecyl sulfate and demonstrate a new approach to quantify the characteristic rate constants which is independent of mass transfer interference and long term drifts of the measured signal. This method has been investigated theoretically by Monte-Carlo simulations but so far there has been no sensor technology with a sufficient signal-to-noise ratio.rnSecond, I apply plasmonic nanoparticles as sensors for the determination of diffusion coefficients. Thereby, the sensing volume of a single, immobilized nanorod is used as detection volume. When a diffusing particle enters the detection volume a shift in the resonance wavelength is introduced. As no labeling of the analyte is necessary the hydrodynamic radius and thus the diffusion properties are not altered and can be studied in their natural form. In comparison to the conventional Fluorescence Correlation Spectroscopy technique a volume reduction by a factor of 5000-10000 is reached.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die mittlere Überlebenszeit nach Erkennung eines Glioblastoms ohne Behandlung liegt bei 3 Monaten und kann durch die Behandlung mit Temozolomid (TMZ) auf etwa 15 Monate gesteigert werden. Neben TMZ sind die chlorethylierenden Nitrosoharnstoffe die meistversprechendsten und am häufigsten eingesetzten Chemotherapeutika in der Gliomtherapie. Hier liegt die mittlere Überlebenszeit bei 17,3 Monaten. Um die Therapie des Glioblastoms noch effektiver zu gestalten und Resistenzen zu begegnen, werden unterschiedlichste Ansätze untersucht. Eine zentrale Rolle spielen hierbei das activator protein 1 (AP-1) und die mitogen aktivierten Proteinkinasen (MAPK), deren Funktion in bisherigen Arbeiten noch unzureichend beleuchtet wurde.rnBesonders mit der Rolle des AP-1-bildenden Proteins FRA-1 in der Therapie des Glioblastoms haben sich bisher nur wenige Arbeiten beschäftigt, weshalb im ersten Teil der vorliegenden Arbeit dessen Funktion in der Regulation der Chemosensitivität gegenüber dem chlorethylierenden Agenz ACNU genauer untersucht wurde. Es konnte gezeigt werden, dass die FRA 1-Expression durch Behandlung mit ACNU induziert wird. Die Induktion erfolgte über die beiden MAPKs ERK1/2 und p38K. JNK hatte keinen Einfluss auf die Induktion. Durch die Herunterregulation der FRA-1-Expression mit Hilfe von siRNA und eines shRNA exprimierenden Plasmids kam es zu einer signifikanten Sensitivierung gegenüber ACNU. Dabei konnte gezeigt werden, dass die Herunterregulation der FRA-1-Expression in einer verminderten AP 1-Bildung, bedingt durch eine reduzierte Menge an FRA-1 im AP-1-Komplex resultiert. Die Sensitivierung gegenüber ACNU ist weder durch eine Veränderung in der DNA-Reparatur, noch in der Modulation der FAS-Ligand- bzw. FAS-Rezeptor-Expression bedingt. Auch die hier untersuchten BCL 2-Familienmitglieder wiesen keine Unterschiede in der Expression durch Modulation der FRA 1-Expression auf. Allerdings kam es durch die verminderte FRA-1-Expression zu einer Reduktion der Zellzahl in der G2/M-Phase nach Behandlung mit ACNU. Diese ging einher mit einer reduzierten Menge an phosphoryliertem und unphosphoryliertem CHK1, weshalb davon auszugehen ist, dass FRA 1 nach ACNU-Behandlung in Gliomzellen vor der Apoptose schützt, indem es modulierend auf die Zellzykluskontrolle einwirkt.rnIm zweiten Teil dieser Arbeit wurde die Regulation der apoptotischen Antwort nach Behandlung mit ACNU und TMZ genauer beleuchtet, wobei ein spezielles Augen¬merk auf AP 1 und die MAPKs gelegt wurde. Hier konnte gezeigt werden, dass die Apoptose nach Behandlung mit ACNU bzw. TMZ sowohl durch Spaltung von Pro-Caspase 8, als auch Pro-Caspase 9 eingeleitet wird. Dabei akkumulierte in beiden Fällen p53 vermehrt im Zellkern. Eine Inhibierung der transkriptionellen Aktivität von p53 führte nach ACNU-Behandlung zu einer Sensitivierung der Zellen, nach TMZ-Behandlung kam es zu einem leichten Anstieg in der Vitälität. Der FAS-Rezeptor wurde nach ACNU- und nach TMZ-Behandlung aktiviert und auch die DNA-Reparaturproteine DDB2 und XPC wurden in beiden Fällen vermehrt exprimiert. Für die MAPKs JNK und ERK1/2 konnte gezeigt werden, dass diese pro-apoptotisch wirken. Die AP-1-Bildung nach ACNU-Behandlung erfolgte bereits nach 24 h und war von langer Dauer, wohingegen nach TMZ-Behandlung nur eine transiente AP 1-Bildung zu relativ späten Zeitpunkten detektiert werden konnte. Ebenso konnte für das AP-1-Zielgen FAS-Ligand nach ACNU-Behandlung eine relativ schnelle, lang anhaltende Aktivierung detektiert werden, wohingegen nach TMZ-Behandlung zu einem späten Zeitpunkt ein kurzer Anstieg im Signal zu verzeichnen war. In späteren Experimenten konnte gezeigt werden, dass das BCL-2-Familienmitglied BIM eine zentrale Rolle in der Regulation des intrinsischen Apoptosesignalweges nach Behandlung mit ACNU und TMZ spielt. Die hier entstanden Ergebnisse tragen entscheidend zum Verständnis der durch diese beiden Agenzien gesteuerten, apoptotischen Signalwege bei und bieten eine fundierte Grundlage für weitere Untersuchungen.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis investigates metallic nanostructures exhibiting surface plasmon resonance for the amplification of fluorescence signal in sandwich immunoassays. In this approach, an analyte is captured by an antibody immobilized on a plasmonic structure and detected by a subsequently bound fluorophore labeled detection antibody. The highly confined field of surface plasmons originates from collective charge oscillations which are associated with high electromagnetic field enhancements at the metal surface and allow for greatly increased fluorescence signal from the attached fluorophores. This feature allows for improving the signal-to-noise ratio in fluorescence measurements and thus advancing the sensitivity of the sensor platform. In particular, the thesis presents two plasmonic nanostructures that amplify fluorescence signal in devices that rely on epifluorescence geometry, in which the fluorophore absorbs and emits light from the same direction perpendicular to the substrate surface.rnThe first is a crossed relief gold grating that supports propagating surface plasmon polaritons (SPPs) and second, gold nanoparticles embedded in refractive index symmetric environment exhibiting collective localized surface plasmons (cLSPs). Finite-difference time-domain simulations are performed in order to design structures for the optimum amplification of established Cy5 and Alexa Fluor 647 fluorophore labels with the absorption and emission wavelengths in the red region of spectrum. The design takes into account combined effect of surface plasmon-enhanced excitation rate, directional surface plasmon-driven emission and modified quantum yield for characteristic distances in immunoassays. Homebuilt optical instruments are developed for the experimental observation of the surface plasmon mode spectrum, measurements of the angular distribution of surface plasmon-coupled fluorescence light and a setup mimicking commercial fluorescence reading systems in epifluorescence geometry.rnCrossed relief grating structures are prepared by interference lithography and multiple copies are made by UV nanoimprint lithography. The fabricated crossed diffraction gratings were utilized for sandwich immunoassay-based detection of the clinically relevant inflammation marker interleukin 6 (IL-6). The enhancement factor of the crossed grating reached EF=100 when compared to a flat gold substrate. This result is comparable to the highest reported enhancements to date, for fluorophores with relatively high intrinsic quantum yield. The measured enhancement factor excellently agrees with the predictions of the simulations and the mechanisms of the enhancement are explained in detail. Main contributions were the high electric field intensity enhancement (30-fold increase) and the directional fluorescence emission at (4-fold increase) compared to a flat gold substrate.rnCollective localized surface plasmons (cLSPs) hold potential for even stronger fluorescence enhancement of EF=1000, due to higher electric field intensity confinement. cLSPs are established by diffractive coupling of the localized surface plasmon resonance (LSPR) of metallic nanoparticles and result in a narrow resonance. Due to the narrow resonance, it is hard to overlap the cLSPs mode with the absorption and emission bands of the used fluorophore, simultaneously. Therefore, a novel two resonance structure that supports SPP and cLSP modes was proposed. It consists of a 2D array of cylindrical gold nanoparticles above a low refractive index polymer and a silver film. A structure that supports the proposed SPP and cLSP modes was prepared by employing laser interference lithography and the measured mode spectrum was compared to simulation results.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Der atmosphärische Kreislauf reaktiver Stickstoffverbindungen beschäftigt sowohl die Naturwissenschaftler als auch die Politik. Dies ist insbesondere darauf zurückzuführen, dass reaktive Stickoxide die Bildung von bodennahem Ozon kontrollieren. Reaktive Stickstoffverbindungen spielen darüber hinaus als gasförmige Vorläufer von Feinstaubpartikeln eine wichtige Rolle und der Transport von reaktivem Stickstoff über lange Distanzen verändert den biogeochemischen Kohlenstoffkreislauf des Planeten, indem er entlegene Ökosysteme mit Stickstoff düngt. Die Messungen von stabilen Stickstoffisotopenverhältnissen (15N/14N) bietet ein Hilfsmittel, welches es erlaubt, die Quellen von reaktiven Stickstoffverbindungen zu identifizieren und die am Stickstoffkeislauf beteiligten Reaktionen mithilfe ihrer reaktionsspezifischen Isotopenfraktionierung genauer zu untersuchen. rnIn dieser Doktorarbeit demonstriere ich, dass es möglich ist, mit Hilfe von Nano-Sekundärionenmassenspektrometrie (NanoSIMS) verschiedene stickstoffhaltige Verbindungen, die üblicherweise in atmosphärischen Feinstaubpartikeln vorkommen, mit einer räumlichen Auflösung von weniger als einem Mikrometer zu analysieren und zu identifizieren. Die Unterscheidung verschiedener stickstoffhaltiger Verbindungen erfolgt anhand der relativen Signalintensitäten der positiven und negativen Sekundärionensignale, die beobachtet werden, wenn die Feinstaubproben mit einem Cs+ oder O- Primärionenstrahl beschossen werden. Die Feinstaubproben können direkt auf dem Probenahmesubstrat in das Massenspektrometer eingeführt werden, ohne chemisch oder physikalisch aufbereited zu werden. Die Methode wurde Mithilfe von Nitrat, Nitrit, Ammoniumsulfat, Harnstoff, Aminosären, biologischen Feinstaubproben (Pilzsporen) und Imidazol getestet. Ich habe gezeigt, dass NO2 Sekundärionen nur beim Beschuss von Nitrat und Nitrit (Salzen) mit positiven Primärionen entstehen, während NH4+ Sekundärionen nur beim Beschuss von Aminosäuren, Harnstoff und Ammoniumsalzen mit positiven Primärionen freigesetzt werden, nicht aber beim Beschuss biologischer Proben wie z.B. Pilzsporen. CN- Sekundärionen werden beim Beschuss aller stickstoffhaltigen Verbindungen mit positiven Primärionen beobachtet, da fast alle Proben oberflächennah mit Kohlenstoffspuren kontaminiert sind. Die relative Signalintensität der CN- Sekundärionen ist bei kohlenstoffhaltigen organischen Stickstoffverbindungen am höchsten.rnDarüber hinaus habe ich gezeigt, dass an reinen Nitratsalzproben (NaNO3 und KNO3), welche auf Goldfolien aufgebracht wurden speziesspezifische stabile Stickstoffisotopenverhältnisse mithilfe des 15N16O2- / 14N16O2- - Sekundärionenverhältnisses genau und richtig gemessen werden können. Die Messgenauigkeit auf Feldern mit einer Rastergröße von 5×5 µm2 wurde anhand von Langzeitmessungen an einem hausinternen NaNO3 Standard als ± 0.6 ‰ bestimmt. Die Differenz der matrixspezifischen instrumentellen Massenfraktionierung zwischen NaNO3 und KNO3 betrug 7.1 ± 0.9 ‰. 23Na12C2- Sekundärionen können eine ernst zu nehmende Interferenz darstellen wenn 15N16O2- Sekundärionen zur Messung des nitratspezifischen schweren Stickstoffs eingesetzt werden sollen und Natrium und Kohlenstoff im selben Feinstaubpartikel als interne Mischung vorliegt oder die natriumhaltige Probe auf einem kohlenstoffhaltigen Substrat abgelegt wurde. Selbst wenn, wie im Fall von KNO3, keine derartige Interferenz vorliegt, führt eine interne Mischung mit Kohlenstoff im selben Feinstaubpartikel zu einer matrixspezifischen instrumentellen Massenfraktionierung die mit der folgenden Gleichung beschrieben werden kann: 15Nbias = (101 ± 4) ∙ f − (101 ± 3) ‰, mit f = 14N16O2- / (14N16O2- + 12C14N-). rnWird das 12C15N- / 12C14N- Sekundärionenverhältnis zur Messung der stabilen Stickstoffisotopenzusammensetzung verwendet, beeinflusst die Probematrix die Messungsergebnisse nicht, auch wenn Stickstoff und Kohlenstoff in den Feinstaubpartikeln in variablen N/C–Verhältnissen vorliegen. Auch Interferenzen spielen keine Rolle. Um sicherzustellen, dass die Messung weiterhin spezifisch auf Nitratspezies eingeschränkt bleibt, kann eine 14N16O2- Maske bei der Datenauswertung verwendet werden. Werden die Proben auf einem kohlenstoffhaltigen, stickstofffreien Probennahmesubstrat gesammelt, erhöht dies die Signalintensität für reine Nitrat-Feinstaubpartikel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To prospectively evaluate a 3-dimensional spoiled gradient-dual-echo (3D SPGR-DE) magnetic resonance imaging (MRI) sequence for the qualitative and quantitative analysis of liver fat content (LFC) in patients with the suspicion of fatty liver disease using histopathology as the standard of reference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-melanoma skin cancers (NMSCs) are the most common malignancies after solid organ transplantation. Their incidence increases with time after transplantation. Calcineurin-inhibitors (CNIs) and azathioprine are known as skin neoplasia-initiating and -enhancing immunosuppressants. In contrast, increasing clinical experience suggests a relevant antiproliferative effect of mammalian target of rapamycin inhibitors, also named proliferation signal inhibitors (PSIs). We report the case of a cardiac allograft recipient with an impressive and consolidated reduction of recurrent NMSC, observed after conversion from CNI-therapy to a PSI-based protocol.