874 resultados para Sight disablement.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Being able to judge another person's visuo-spatial perspective is an essential social skill, hence we investigated the generalizability of the involved mechanisms across cultures and genders. Developmental, cross-species, and our own previous research suggest that two different forms of perspective taking can be distinguished, which are subserved by two distinct mechanisms. The simpler form relies on inferring another's line-of-sight, whereas the more complex form depends on embodied transformation into the other's orientation in form of a simulated body rotation. Our current results suggest that, in principle, the same basic mechanisms are employed by males and females in both, East-Asian (EA; Chinese) and Western culture. However, we also confirmed the hypothesis that Westerners show an egocentric bias, whereas EAs reveal an other-oriented bias. Furthermore, Westerners were slower overall than EAs and showed stronger gender differences in speed and depth of embodied processing. Our findings substantiate differences and communalities in social cognition mechanisms across genders and two cultures and suggest that cultural evolution or transmission should take gender as a modulating variable into account.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Punctate inner choroidopathy is an idiopathic inflammatory ocular disorder characteristically seen in young myopic women. Visual prognosis is generally good but sight threatening choroidal neovascularisation may develop in up to 40% patients.1 We discuss verteporfin photodynamic therapy in subfoveal choroidal neovascularisation secondary to punctate inner choroidopathy that failed to respond to oral corticosteroids and had poor results with submacular surgery in the contralateral eye.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims - A National Screening Programme for diabetic eye disease in the UK is in development. We propose a grading and early disease management protocol to detect sight-threatening diabetic retinopathy and any retinopathy, which will allow precise quality assurance at all steps while minimizing false-positive referral to the hospital eye service. Methods - Expert panel structured discussions between 2000 and 2002 with review of existing evidence and grading classifications. Proposals - Principles of the protocol include: separate grading of retinopathy and maculopathy, minimum number of steps, compatible with central monitoring, expandable for established more complex systems and for research, no lesion counting, no ‘questionable’ lesions, attempt to detect focal exudative, diffuse and ischaemic maculopathy and fast track referral from primary or secondary graders. Sight-threatening diabetic retinopathy is defined as: preproliferative retinopathy or worse, sight-threatening maculopathy and/or the presence of photocoagulation. In the centrally reported minimum data set retinopathy is graded into four levels: none (R0), background (R1), preproliferative (R2), proliferative (R3). Maculopathy and photocoagulation are graded as absent (M0, P0) or present (M1, P1). Discussion - The protocol developed by the Diabetic Retinopathy Grading and Disease Management Working Party represents a new consensus upon which national guidelines can be based leading to the introduction of quality-assured screening for people with diabetes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the UK, 20% of people aged 75 years and over are living with sight loss and age-related macular degeneration (AMD) is the most common cause of sight loss in the UK, impacting nearly 10% of those over 80; regrettably, these fgures are expected to increase in coming decades as the population ages (RNIB, 2012). This paper reports on the authors' design activities conducted for the purpose of informing the development of an assistive self-monitoring, ability-reactive technology (SMART) for older adults with AMD. The authors refect on their experience of adopting and adapting the PICTIVE (Plastic Interface for Collaborative Technology Initiatives through Video Exploration) participatory design approach (Muller, 1992) to support effective design with and for their special needs user group, refect on participants' views of being part of the process, and discuss the design themes identifed via their PD activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the UK, 20% of people aged 75 years and over are living with sight loss and age-related macular degeneration (AMD) is the most common cause of sight loss in the UK, impacting nearly 10% of those over 80; regrettably, these figures are expected to increase in coming decades as the population ages (RNIB, 2012). This paper reports on the authors' design activities conducted for the purpose of informing the development of an assistive self-monitoring, ability-reactive technology (SMART) for older adults with AMD. The authors reflect on their experience of adopting and adapting the PICTIVE (Plastic Interface for Collaborative Technology Initiatives through Video Exploration) participatory design approach (Muller, 1992) to support effective design with and for their special needs user group, reflect on participants' views of being part of the process, and discuss the design themes identified via their PD activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As we settle into a new year, this second issue of Contact Lens and Anterior Eye allows us to reflect on how new research in this field impacts our understanding, but more importantly, how we use this evidence basis to enhance our day to day practice, to educate the next generation of students and to construct the research studies to deepen our knowledge still further. The end of 2014 saw the publication of the UK governments Research Exercise Framework (REF) which ranks Universities in terms of their outputs (which includes their paper, publications and research income), environment (infrastructure and staff support) and for the first time impact (defined as “any effect on, change or benefit to the economy, society, culture, public policy or services, health, the environment or quality of life, beyond academia” [8]). The REF is a process of expert review, carried out in 36 subject-based units of assessment, of which our field is typically submitted to the Allied Health, Dentistry, Nursing and Pharmacy panel. Universities that offer Optometry did very well with Cardiff, Manchester and Aston in the top 10% out of the 94 Universities that submitted to this panel (Grade point Average ranked order). While the format of the new exercise (probably in 2010) to allocate the more than £2 billion of UK government research funds is yet to be determined, it is already rumoured that impact will contribute an even larger proportion to the weighting. Hence it is even more important to reflect on the impact of our research. In this issue, Elisseef and colleagues [5] examine the intriguing potential of modifying a lens surface to allow it to bind to known wetting agents (in this case hyaluronic acid) to enhance water retention. Such a technique has the capacity to reduced friction between the lens surface and the eyelids/ocular surface, presumably leading to higher comfort and less reason for patients to discontinue with lens wear. Several papers in this issue report on the validity of new high precision, fast scanning imaging and quantification equipment, utilising techniques such as Scheimpflug, partial coherence interferometry, aberrometry and video allowing detailed assessment of anterior chamber biometry, corneal topography, corneal biomechanics, peripheral refraction, ocular aberrations and lens fit. The challenge is how to use this advanced instrumentation which is becoming increasingly available to create real impact. Many challenges in contact lenses and the anterior eye still prevail in 2015 such as: -While contact lens and refractive surgery complications are relatively rare, they are still too often devastating to the individual and their quality of life (such as the impact and prognosis of patients with Acanthmoeba Keratitis reported by Jhanji and colleagues in this issue [7]). How can we detect those patients who are going to be affected and what modifications do we need to make to contact lenses and patient management prevent this occurring? -Drop out from contact lenses still occurs at a rapid rate and symptoms of dry eye seem to be the leading cause driving this discontinuation of wear [1] and [2]. What design, coating, material and lubricant release mechanism will make a step change in end of day comfort in particular? -Presbyopia is a major challenge to hassle free quality vision and is one of the first signs of ageing noticed by many people. As an emmetrope approaching presbyopia, I have a vested interest in new medical devices that will give me high quality vision at all distances when my arms won’t stretch any further. Perhaps a new definition of presbyopia could be when you start to orientate your smartphone in the landscape direction to gain the small increase in print size needed to read! Effective accommodating intraocular lenses that truly mimic the pre-presbyopic crystalline lenses are still a way off [3] and hence simultaneous images achieved through contact lenses, intraocular lenses or refractive surgery still have a secure future. However, splitting light reaching the retina and requiring the brain to supress blurred images will always be a compromise on contrast sensitivity and is liable to cause dysphotopsia; so how will new designs account for differences in a patient's task demands and own optical aberrations to allow focused patient selection, optimising satisfaction? -Drug delivery from contact lenses offers much in terms of compliance and quality of life for patients with chronic ocular conditions such as glaucoma, dry eye and perhaps in the future, dry age-related macular degeneration; but scientific proof-of-concept publications (see EIShaer et al. [6]) have not yet led to commercial products. Part of this is presumably the regulatory complexity of combining a medical device (the contact lens) and a pharmaceutical agent. Will 2015 be the year when this innovation finally becomes a reality for patients, bringing them an enhanced quality of life through their eye care practitioners and allowing researchers to further validate the use of pharmaceutical contact lenses and propose enhancements as the technology matures? -Last, but no means least is the field of myopia control, the topic of the first day of the BCLA's Conference in Liverpool, June 6–9th 2015. The epidemic of myopia is a blight, particularly in Asia, with significant concerns over sight threatening pathology resulting from the elongated eye. This is a field where real impact is already being realised through new soft contact lens optics, orthokeratology and low dose pharmaceuticals [4], but we still need to be able to better predict which technique will work best for an individual and to develop new techniques to retard myopia progression in those who don’t respond to current treatments, without increasing their risk of complications or the treatment impacting their quality of life So what will your New Year's resolution be to make 2015 a year of real impact, whether by advancing science or applying the findings published in journals such as Contact Lens and Anterior Eye to make a real difference to your patients’ lives?

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pseudophakic patients are frequently encountered in optometric practice, often the result of cataract extraction but also presbyopia correction. Given advances in technology and surgery, the demand for intraocular lenses for correcting a variety of refractive requirements has increased owing to an ageing population. Based on the patient’s needs, either fixed focus, toric, accommodating or multifocal intraocular lenses (IOLs) may be implanted. During optometric examination, attention should be drawn to a history of IOLs and the potential complications they may cause in order to manage them effectively, particularly where sight is threatened. Although objective and subjective refraction does not differ greatly between phakic and pseudophakic patients, care should be taken to set the patient up correctly and the reflex during retinoscopy observed for posterior sub-capsular opacification. Additional tests such as reading speed, and glare and contrast sensitivity are necessary to determine the outcome of IOL surgery and detect potential problems associated with multifocal and accommodating IOLs. Based upon the results of these tests, refraction, and type of IOL, contact lens or spectacle correction may be required to meet the visual demands of the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the UK, 20 per cent of people aged 75 years and over are living with sight loss; this percentage is expected to increase as the population ages (RNIB, 2011). Age-Related Macular Degeneration (AMD) is the UK’s leading cause of severe visual impairment amongst the elderly. It accounts for 16,000 blind/partial sight registrations per year and is the leading cause of blindness among people aged 55 years and older in western countries (Bressler, 2004). Our ultimate goal is to develop an assistive mobile application to support accurate and convenient diet data collection on which basis to then provide customised dietary advice and recommendations in order to help support individuals with AMD to mitigate their ongoing risk and retard the progression of the disease. In this paper, we focus on our knowledge elicitation activities conducted to help us achieve a deep and relevant understanding of our target user group. We report on qualitative findings from focus groups and observational studies with persons with AMD and interviews with domain experts which enable us to fully appreciate the impact that technology may have on our intended users as well as to inform the design and structure of our proposed mobile assistive application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article presents a laser tracker position optimization code based on the tracker uncertainty model developed by the National Physical Laboratory (NPL). The code is able to find the optimal tracker positions for generic measurements involving one or a network of many trackers, and an arbitrary set of targets. The optimization is performed using pattern search or optionally, genetic algorithm (GA) or particle swarm optimization (PSO). Different objective function weightings for the uncertainties of individual points, distance uncertainties between point pairs, and the angular uncertainties between three points can be defined. Constraints for tracker position limits and minimum measurement distances have also been implemented. Furthermore, position optimization taking into account of lines-of-sight (LOS) within complex CAD geometry have also been demonstrated. The code is simple to use and can be a valuable measurement planning tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article presents a laser tracker position optimization code based on the tracker uncertainty model developed by the National Physical Laboratory (NPL). The code is able to find the optimal tracker positions for generic measurements involving one or a network of many trackers, and an arbitrary set of targets. The optimization is performed using pattern search or optionally, genetic algorithm (GA) or particle swarm optimization (PSO). Different objective function weightings for the uncertainties of individual points, distance uncertainties between point pairs, and the angular uncertainties between three points can be defined. Constraints for tracker position limits and minimum measurement distances have also been implemented. Furthermore, position optimization taking into account of lines-of-sight (LOS) within complex CAD geometry have also been demonstrated. The code is simple to use and can be a valuable measurement planning tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the effectiveness of digital diabetic retinopathy screening in patients aged 90 years and over.MethodsThis is a retrospective analysis of 200 randomly selected patients eligible for diabetic retinopathy screening aged 90 years and over within the Birmingham, Solihull, and Black Country Screening Programme.ResultsOne hundred and seventy-nine (90%) patients attended screening at least once. 133 (74%) annual screening after their first screen, of whom 59% had no detectable diabetic retinopathy; 38 (21%) were referred for ophthalmology clinical assessment-36 for nondiabetic retinopathy reasons and two for diabetic maculopathy. Cataract accounted for 50% of all referrals for ophthalmology clinical assessment. Of the 133 patients placed on annual screening, 93 (70%) were screened at least once more. In terms of level of diabetic retinopathy, assessability or other ocular pathologies, 8 improved, 51 remained stable, and 31 deteriorated. Of the latter, 19 patients were referred for ophthalmology clinical assessment; none of these for diabetic retinopathy.ConclusionsScreening provides opportunistic identification of important nondiabetic retinopathy eye conditions. However, in view of the low identification rate of sight-threatening diabetic retinopathy in patients aged 90 years and over, and the current mission statement of the NHS Diabetic Eye Screening Programme, systematic annual diabetic retinopathy screening may not be justified in this age group of patients, but rather be performed in optometric practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To determine the best photographic surrogate markers for detecting sight-threatening macular oedema (MO) in people with diabetes attending UK national screening programmes. Design: A multicentre, prospective, observational cohort study of 3170 patients with photographic signs of diabetic retinopathy visible within the macular region [exudates within two disc diameters, microaneurysms/dot haemorrhages (M/DHs) and blot haemorrhages (BHs)] who were recruited from seven study centres. Setting: All patients were recruited and imaged at one of seven study centres in Aberdeen, Birmingham, Dundee, Dunfermline, Edinburgh, Liverpool and Oxford. Participants: Subjects with features of diabetic retinopathy visible within the macular region attending one of seven diabetic retinal screening programmes. Interventions: Alternative referral criteria for suspected MO based on photographic surrogate markers; an optical coherence tomographic examination in addition to the standard digital retinal photograph. Main outcome measures: (1) To determine the best method to detect sight-threatening MO in people with diabetes using photographic surrogate markers. (2) Sensitivity and specificity estimates to assess the costs and consequences of using alternative strategies. (3) Modelled long-term costs and quality-adjusted life-years (QALYs). Results: Prevalence of MO was strongly related to the presence of lesions and was roughly five times higher in subjects with exudates or BHs or more than two M/DHs within one disc diameter. Having worse visual acuity was associated with about a fivefold higher prevalence of MO. Current manual screening grading schemes that ignore visual acuity or the presence of M/DHs could be improved by taking these into account. Health service costs increase substantially with more sensitive/less specific strategies. A fully automated strategy, using the automated detection of patterns of photographic surrogate markers, is superior to all current manual grading schemes for detecting MO in people with diabetes. The addition of optical coherence tomography (OCT) to each strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. Conclusions: Compared with all current manual grading schemes, for the same sensitivity, a fully automated strategy, using the automated detection of patterns of photographic surrogate markers, achieves a higher specificity for detecting MO in people with diabetes, especially if visual acuity is included in the automated strategy. Overall, costs to the health service are likely to increase if more sensitive referral strategies are adopted over more specific screening strategies for MO, for only very small gains in QALYs. The addition of OCT to each screening strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. © Queen's Printer and Controller of HMSO 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients who present with background DR should continue to be screened annually as a high prportion of these patients develop sight threatening DR (12%). A low prportion of patients with no DR at baseline were referred for STDR (1.3%). Out of the 51 patients in this category referred only 1 required laser. The authors suggest that patients graded R0M0 could be screened biannually.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. A 4 year retrospective follow up of 996 patients who pre-sented with no DR and 500 with background DR at baseline digital DR screening in 2006. Purpose. To evaluate the safety of increasing screening intervals in patients with no diabetic retinopathy (DR) or with background DR.Methods. A 4 year retrospective follow up of 996 patients who presented with no DR and 500 with background DR at baseline digital DR screening in 2006.results. Background DR Group: Of the 500 subjects that had back-ground DR in 2006, 231 were referred for DR, with an average DR routine referral rate of 12% (46 subjects) per year. nodrgrouP. Of the 996 patients who had no DR at baseline, 51 were referred over the 4 years for sight threatening DR (STDR), of these 45 patients have definite STDR confirmed by ophthalmological examination. 78% of these had type 2 diabetes and mean age at referral was 60 years (25-87). Mean diabetes duration was 10.7 years (3-32), with a mean HbA1c of 7.8% (5.7-11.3%). Eight patients (0.9%) were referred in the first year, 9 (0.9%) in the second year, 19 (1.9%) in the third year and 15 (1.5%) in the fourth year. 86% of referrals were for maculopathy, and all had observable retinopathy and none required ophthalmology clinic assessment or laser treatment.If biannual screening was adopted for patients with no DR at baseline, allowing for patients who subsequently develop background DR and would then revert to annual screening, a total of 7 (0.7%) patients would not have been appropriately referred for STDR and would have waited a further year for identification. None of the 51 referrals across the 4 years required laser treatment apart from just one patient who developed PDR in year 4 (2010) and had background since 2007.conclusIons. It could be recommended that it is safe to screen pa-tients with no DR biannually due to the low risk of developing STDR. However, patients who present with background DR should continue to be screened annually as there is a significant proportion developing STDR and would not be identified at an appropriate screening interval.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Synthetic phonics is the widely accepted approach for teaching reading in English: children are taught to sound out the letters in a word then blend these sounds together. Aims: We compared the impact of two synthetic phonics programmes on early reading.SampleChildren received Letters and Sounds (L&S; 7 schools) which teaches multiple letter-sound mappings or Early Reading Research (ERR; 10 schools) which teaches only the most consistent mappings plus frequent words by sight.MethodWe measured phonological awareness (PA) and reading from school entry to the end of the second (all schools) or third school year (4 ERR, 3 L&S schools). Results: PA was significantly related to all reading measures for the whole sample. However, there was a closer relationship between PA and exception word reading for children receiving the L&S programme. The programmes were equally effective overall, but their impact on reading significantly interacted with school-entry PA: children with poor PA at school entry achieved higher reading attainments under ERR (significant group difference on exception word reading at the end of the first year), whereas children with good PA performed equally well under either programme. Conclusions: The more intensive phonics programme (L&S) heightened the association between PA and exception word reading. Although the programmes were equally effective for most children, results indicate potential benefits of ERR for children with poor PA. We suggest that phonics programmes could be simplified to teach only the most consistent mappings plus frequent words by sight.