890 resultados para Sensitivity and Specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An integrated approach for multi-spectral segmentation of MR images is presented. This method is based on the fuzzy c-means (FCM) and includes bias field correction and contextual constraints over spatial intensity distribution and accounts for the non-spherical cluster's shape in the feature space. The bias field is modeled as a linear combination of smooth polynomial basis functions for fast computation in the clustering iterations. Regularization terms for the neighborhood continuity of intensity are added into the FCM cost functions. To reduce the computational complexity, the contextual regularizations are separated from the clustering iterations. Since the feature space is not isotropic, distance measure adopted in Gustafson-Kessel (G-K) algorithm is used instead of the Euclidean distance, to account for the non-spherical shape of the clusters in the feature space. These algorithms are quantitatively evaluated on MR brain images using the similarity measures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preeclampsia (PE), a syndrome affecting 5% of pregnancies, characterized by hypertension and proteinuria, is a leading cause of maternal and fetal morbidity and mortality. The condition is often accompanied by the presence of a circulating maternal autoantibody, the angiotensin II type I receptor agonistic autoantibody (AT(1)-AA). However, the prevalence of AT(1)-AA in PE remains unknown, and the correlation of AT(1)-AA titers with the severity of the disease remains undetermined. We used a sensitive and high-throughput luciferase bioassay to detect AT(1)-AA levels in the serum of 30 normal, 37 preeclamptic (10 mild and 27 severe), and 23 gestational hypertensive individuals. Here we report that AT(1)-AA is highly prevalent in PE ( approximately 95%). Next, by comparing the levels of AT(1)-AA among women with mild and severe PE, we found that the titer of AT(1)-AA is proportional to the severity of the disease. Intriguingly, among severe preeclamptic patients, we discovered that the titer of AT(1)-AA is significantly correlated with the clinical features of PE: systolic blood pressure (r=0.56), proteinuria (r=0.70), and soluble fms-like tyrosine kinase-1 level (r=0.71), respectively. Notably, only AT(1)-AA, and not soluble fms-like tyrosine kinase-1, levels are elevated in gestational hypertensive patients. These data serve as compelling clinical evidence that AT(1)-AA is highly prevalent in PE, and its titer is strongly correlated to the severity of the disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To develop and implement a method for improved cerebellar tissue classification on the MRI of brain by automatically isolating the cerebellum prior to segmentation. MATERIALS AND METHODS: Dual fast spin echo (FSE) and fluid attenuation inversion recovery (FLAIR) images were acquired on 18 normal volunteers on a 3 T Philips scanner. The cerebellum was isolated from the rest of the brain using a symmetric inverse consistent nonlinear registration of individual brain with the parcellated template. The cerebellum was then separated by masking the anatomical image with individual FLAIR images. Tissues in both the cerebellum and rest of the brain were separately classified using hidden Markov random field (HMRF), a parametric method, and then combined to obtain tissue classification of the whole brain. The proposed method for tissue classification on real MR brain images was evaluated subjectively by two experts. The segmentation results on Brainweb images with varying noise and intensity nonuniformity levels were quantitatively compared with the ground truth by computing the Dice similarity indices. RESULTS: The proposed method significantly improved the cerebellar tissue classification on all normal volunteers included in this study without compromising the classification in remaining part of the brain. The average similarity indices for gray matter (GM) and white matter (WM) in the cerebellum are 89.81 (+/-2.34) and 93.04 (+/-2.41), demonstrating excellent performance of the proposed methodology. CONCLUSION: The proposed method significantly improved tissue classification in the cerebellum. The GM was overestimated when segmentation was performed on the whole brain as a single object.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A nonlinear viscoelastic image registration algorithm based on the demons paradigm and incorporating inverse consistent constraint (ICC) is implemented. An inverse consistent and symmetric cost function using mutual information (MI) as a similarity measure is employed. The cost function also includes regularization of transformation and inverse consistent error (ICE). The uncertainties in balancing various terms in the cost function are avoided by alternatively minimizing the similarity measure, the regularization of the transformation, and the ICE terms. The diffeomorphism of registration for preventing folding and/or tearing in the deformation is achieved by the composition scheme. The quality of image registration is first demonstrated by constructing brain atlas from 20 adult brains (age range 30-60). It is shown that with this registration technique: (1) the Jacobian determinant is positive for all voxels and (2) the average ICE is around 0.004 voxels with a maximum value below 0.1 voxels. Further, the deformation-based segmentation on Internet Brain Segmentation Repository, a publicly available dataset, has yielded high Dice similarity index (DSI) of 94.7% for the cerebellum and 74.7% for the hippocampus, attesting to the quality of our registration method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large field studies of travelers' diarrhea for multiple destinations are limited by the need to perform stool cultures on site in a timely manner. A method for the collection, transport, and storage of fecal specimens that does not require immediate processing and refrigeration and that is stable for months would be advantageous. This study was designed to determine if enterotoxigenic Escherichia coli (ETEC) and enteroaggregative E. coli (EAEC) DNA could be identified from cards that were processed for the evaluation of fecal occult blood. U.S. students traveling to Mexico during 2005 to 2007 were monitored for the occurrence of diarrheal illness. When ill, students provided a stool specimen for culture and occult blood by the standard methods. Cards then were stored at room temperature prior to DNA extraction. Fecal PCR was performed to identify ETEC and EAEC in DNA extracted from stools and from occult blood cards. Significantly more EAEC cases were identified by PCR that was performed on DNA that was extracted from cards (49%) or from frozen feces (40%) than from culture methods that used HEp-2 adherence assays (13%) (P < 0.001). Similarly, more ETEC cases were detected from card DNA (38%) than from fecal DNA (30%) or by culture that was followed by hybridization (10%) (P < 0.001). The sensitivity and specificity of the card test were 75 and 62%, respectively, compared to those for EAEC by culture and were 50 and 63%, respectively, compared to those for ETEC. DNA extracted from fecal cards that was used for the detection of occult blood is of use in identifying diarrheagenic E. coli.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investigated in a real-life patient cohort. Objective To investigate the performance of automatic software-based screening for AF in long-term ECGs. Methods Two independent physicians manually screened 22,601 hours of continuous long-term ECGs from 150 patients for AF. Presence, number, and duration of AF episodes were registered. Subsequently, the recordings were screened for AF by an established ECG analysis software (Pathfinder SL), and its performance was validated against the thorough manual analysis (gold standard). Results Sensitivity and specificity for AF detection was 98.5% (95% confidence interval 91.72%–99.96%) and 80.21% (95% confidence interval 70.83%–87.64%), respectively. Software-based AF detection was inferior to manual analysis by physicians (P < .0001). Median AF duration was underestimated (19.4 hours vs 22.1 hours; P < .001) and median number of AF episodes was overestimated (32 episodes vs 2 episodes; P < .001) by the software. In comparison to extensive quantitative manual ECG analysis, software-based analysis saved time (2 minutes vs 19 minutes; P < .001). Conclusion Owing to its high sensitivity and ability to save time, software-based ECG analysis may be used as a screening tool for AF. An additional manual confirmatory analysis may be required to reduce the number of false-positive findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Tests for recent infections (TRIs) are important for HIV surveillance. We have shown that a patient's antibody pattern in a confirmatory line immunoassay (Inno-Lia) also yields information on time since infection. We have published algorithms which, with a certain sensitivity and specificity, distinguish between incident (< = 12 months) and older infection. In order to use these algorithms like other TRIs, i.e., based on their windows, we now determined their window periods. Methods We classified Inno-Lia results of 527 treatment-naïve patients with HIV-1 infection < = 12 months according to incidence by 25 algorithms. The time after which all infections were ruled older, i.e. the algorithm's window, was determined by linear regression of the proportion ruled incident in dependence of time since infection. Window-based incident infection rates (IIR) were determined utilizing the relationship ‘Prevalence = Incidence x Duration’ in four annual cohorts of HIV-1 notifications. Results were compared to performance-based IIR also derived from Inno-Lia results, but utilizing the relationship ‘incident = true incident + false incident’ and also to the IIR derived from the BED incidence assay. Results Window periods varied between 45.8 and 130.1 days and correlated well with the algorithms' diagnostic sensitivity (R2 = 0.962; P<0.0001). Among the 25 algorithms, the mean window-based IIR among the 748 notifications of 2005/06 was 0.457 compared to 0.453 obtained for performance-based IIR with a model not correcting for selection bias. Evaluation of BED results using a window of 153 days yielded an IIR of 0.669. Window-based IIR and performance-based IIR increased by 22.4% and respectively 30.6% in 2008, while 2009 and 2010 showed a return to baseline for both methods. Conclusions IIR estimations by window- and performance-based evaluations of Inno-Lia algorithm results were similar and can be used together to assess IIR changes between annual HIV notification cohorts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Cognitive fluctuation (CF) is a common feature of dementia and a core diagnostic symptom for dementia with Lewy bodies (DLB). CF remains difficult to accurately and reliably detect clinically. This study aimed to develop a psychometric test that could be used by clinicians to facilitate the identification of CF and improve the recognition and diagnosis of DLB and Parkinson disease, and to improve differential diagnosis of other dementias. METHODS We compiled a 17-item psychometric test for identifying CF and applied this measure in a cross-sectional design. Participants were recruited from the North East of England, and assessments were made in individuals' homes. We recruited people with four subtypes of dementia and a healthy comparison group, and all subjects were administered this pilot scale together with other standard ratings. The psychometric properties of the scale were examined with exploratory factor analysis. We also examined the ability of individual items to identify CF to discriminate between dementia subtypes. The sensitivity and specificity of discriminating items were explored along with validity and reliability analyses. RESULTS Participants comprised 32 comparison subjects, 30 people with Alzheimer disease, 30 with vascular dementia, 29 with DLB, and 32 with dementia associated with Parkinson disease. Four items significantly discriminated between dementia groups and showed good levels of sensitivity (range: 78.6%-80.3%) and specificity (range: 73.9%-79.3%). The scale had very good levels of test-retest (Cronbach's alpha: 0.82) and interrater (0.81) reliabilities. The four items loaded onto three different factors. These items were: 1) marked differences in functioning during the daytime; 2) daytime somnolence; 3) daytime drowsiness; and 4) altered levels of consciousness during the day. CONCLUSIONS We identified four items that provide valid, sensitive, and specific questions for reliably identifying CF and distinguishing the Lewy body dementias from other major causes of dementia (Alzheimer disease and vascular dementia).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Head-up tilt (HUT) testing is a widely used diagnostic tool in patients with suspected vasovagal syncope (VVS). However, no gold standard exists for this examination and the various protocols used have a limited sensitivity and specificity. Our aim was to determine the sensitivity of a sequential HUT testing protocol including venepuncture (VP) and sublingual nitroglycerin application. METHODS This was a retrospective analysis of the diagnostic gain of a sequential HUT testing protocol including VP applied 10 min after the start of HUT testing and sublingual application of nitroglycerin 20 min after the start of the test protocol in 106 patients with a final diagnosis of VVS. The sensitivity of the test protocol was compared between patients with positive and negative history for VP induced VVS. RESULTS Overall, pre-syncope or syncope occurred in 68 patients (64.2%). Only 17% of all patients fainted spontaneously within 10 min of passive HUT. Another 39.6% fainted within 20 min. Application of nitroglycerin after 20 min of HUT evoked syncope in another 7.5% until the end of 45 min of HUT. The sensitivity of the test protocol for evoking (pre-)syncope was 94.4% in patients with a positive history for VP associated VVS and 58% in patients with a negative history (P < 0.01**); 85.7% of patients with a positive history and 42.9% of patients with a negative history fainted within 20 min of HUT testing (P < 0.01**). CONCLUSIONS Implementation of VP in sequential HUT testing protocols allows the sensitivity of HUT testing to be increased, especially in patients with a positive history for VP associated VVS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To prospectively assess the diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of pelvic lymph node metastases in patients with prostate and/or bladder cancer staged as N0 with preoperative cross-sectional imaging. MATERIALS AND METHODS This study was approved by an independent ethics committee. Written informed consent was obtained from all patients. Patients with no enlarged lymph nodes on preoperative cross-sectional images who were scheduled for radical resection of the primary tumor and extended pelvic lymph node dissection were enrolled. All patients were examined with a 3-T MR unit, and examinations included conventional and DW MR imaging of the entire pelvis. Image analysis was performed by three independent readers blinded to any clinical information. Metastases were diagnosed on the basis of high signal intensity on high b value DW MR images and morphologic features (shape, border). Histopathologic examination served as the standard of reference. Sensitivity and specificity were calculated, and bias-corrected 95% confidence intervals (CIs) were obtained with the bootstrap method. The Fleiss and Cohen κ and median test were applied for statistical analyses. RESULTS A total of 4846 lymph nodes were resected in 120 patients. Eighty-eight lymph node metastases were found in 33 of 120 patients (27.5%). Short-axis diameter of these metastases was less than or equal to 3 mm in 68, more than 3 mm to 5 mm in 13, more than 5 mm to 8 mm in five; and more than 8 mm in two. On a per-patient level, the three readers correctly detected metastases in 26 (79%; 95% CI: 64%, 91%), 21 (64%; 95% CI: 45%, 79%), and 25 (76%; 95% CI: 60%, 90%) of the 33 patients with metastases, with respective specificities of 85% (95% CI: 78%, 92%), 79% (95% CI: 70%, 88%), and 84% (95% CI: 76%, 92%). Analyzed according to hemipelvis, lymph node metastases were detected with histopathologic examination in 44 of 240 pelvic sides (18%); the three readers correctly detected these on DW MR images in 26 (59%; 95% CI: 45%, 73%), 19 (43%; 95% CI: 27%, 57%), and 28 (64%; 95% CI: 47%, 78%) of the 44 cases. CONCLUSION DW MR imaging enables noninvasive detection of small lymph node metastases in normal-sized nodes in a substantial percentage of patients with prostate and bladder cancer diagnosed as N0 with conventional cross-sectional imaging techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE We prospectively assessed the diagnostic accuracy of diffusion-weighted magnetic resonance imaging for detecting significant prostate cancer. MATERIALS AND METHODS We performed a prospective study of 111 consecutive men with prostate and/or bladder cancer who underwent 3 Tesla diffusion-weighted magnetic resonance imaging of the pelvis without an endorectal coil before radical prostatectomy (78) or cystoprostatectomy (33). Three independent readers blinded to clinical and pathological data assigned a prostate cancer suspicion grade based on qualitative imaging analysis. Final pathology results of prostates with and without cancer served as the reference standard. Primary outcomes were the sensitivity and specificity of diffusion-weighted magnetic resonance imaging for detecting significant prostate cancer with significance defined as a largest diameter of the index lesion of 1 cm or greater, extraprostatic extension, or Gleason score 7 or greater on final pathology assessment. Secondary outcomes were interreader agreement assessed by the Fleiss κ coefficient and image reading time. RESULTS Of the 111 patients 93 had prostate cancer, which was significant in 80 and insignificant in 13, and 18 had no prostate cancer on final pathology results. The sensitivity and specificity of diffusion-weighted magnetic resonance imaging for detecting significant PCa was 89% to 91% and 77% to 81%, respectively, for the 3 readers. Interreader agreement was good (Fleiss κ 0.65 to 0.74). Median reading time was between 13 and 18 minutes. CONCLUSIONS Diffusion-weighted magnetic resonance imaging (3 Tesla) is a noninvasive technique that allows for the detection of significant prostate cancer with high probability without contrast medium or an endorectal coil, and with good interreader agreement and a short reading time. This technique should be further evaluated as a tool to stratify patients with prostate cancer for individualized treatment options.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To provide guidance on standards for reporting studies of diagnostic test accuracy for dementia disorders. METHODS An international consensus process on reporting standards in dementia and cognitive impairment (STARDdem) was established, focusing on studies presenting data from which sensitivity and specificity were reported or could be derived. A working group led the initiative through 4 rounds of consensus work, using a modified Delphi process and culminating in a face-to-face consensus meeting in October 2012. The aim of this process was to agree on how best to supplement the generic standards of the STARD statement to enhance their utility and encourage their use in dementia research. RESULTS More than 200 comments were received during the wider consultation rounds. The areas at most risk of inadequate reporting were identified and a set of dementia-specific recommendations to supplement the STARD guidance were developed, including better reporting of patient selection, the reference standard used, avoidance of circularity, and reporting of test-retest reliability. CONCLUSION STARDdem is an implementation of the STARD statement in which the original checklist is elaborated and supplemented with guidance pertinent to studies of cognitive disorders. Its adoption is expected to increase transparency, enable more effective evaluation of diagnostic tests in Alzheimer disease and dementia, contribute to greater adherence to methodologic standards, and advance the development of Alzheimer biomarkers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Clinical benefit response (CBR), based on changes in pain, Karnofsky performance status, and weight, is an established palliative endpoint in trials for advanced gastrointestinal cancer. We investigated whether CBR is associated with survival, and whether CBR reflects a wide-enough range of domains to adequately capture patients' perception. METHODS CBR was prospectively evaluated in an international phase III chemotherapy trial in patients with advanced pancreatic cancer (n = 311) in parallel with patient-reported outcomes (PROs). RESULTS The median time to treatment failure was 3.4 months (range: 0-6). The majority of the CBRs (n = 39) were noted in patients who received chemotherapy for at least 5 months. Patients with CBR (n = 62) had longer survival than non-responders (n = 182) (hazard ratio = 0.69; 95% confidence interval: 0.51-0.94; p = 0.013). CBR was predicted with a sensitivity and specificity of 77-80% by various combinations of 3 mainly physical PROs. A comparison between the duration of CBR (n = 62, median = 8 months, range = 4-31) and clinically meaningful improvements in the PROs (n = 100-116; medians = 9-11 months, range = 4-24) showed similar intervals. CONCLUSION CBR is associated with survival and mainly reflects physical domains. Within phase III chemotherapy trials for advanced gastrointestinal cancer, CBR can be replaced by a PRO evaluation, without losing substantial information but gaining complementary information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Hepatitis B viruses (HBV) harboring mutations in the a-determinant of the Hepatitis B surface antigen (HBsAg) are associated with reduced reactivity of HBsAg assays. OBJECTIVES To evaluate the sensitivity and specificity of three HBsAg point-of-care tests for the detection of HBsAg of viruses harboring HBsAg mutations. STUDY DESIGN A selection of 50 clinical plasma samples containing HBV with HBsAg mutations was used to evaluate the performance of three HBsAg point-of-care tests (Vikia(®), bioMérieux, Marcy-L'Étoile, France. Alere Determine HBsAg™, Iverness Biomedical Innovations, Köln, Germany. Quick Profile™, LumiQuick Diagnostics, California, USA) and compared to the ARCHITECT HBsAg Qualitative(®) assay (Abbott Laboratories, Sligo, Ireland). RESULTS The sensitivity of the point-of-care tests ranged from 98% to 100%. The only false-negative result occurred using the Quick Profile™ assay with a virus harboring a D144A mutation. CONCLUSIONS The evaluated point-of-care tests revealed an excellent sensitivity in detecting HBV samples harboring HBsAg mutations.