972 resultados para Ray Computed-tomography
Resumo:
PURPOSE: To report the lethal course of malignant transformation of retinoma in an adult. METHODS: Case report. A 40-year-old patient presented with retinoma in his right eye and retinoblastoma in his left eye. Enucleation was recommended but refused and the patient received whole eye radiotherapy elsewhere. Five years later he presented again, with temporal hemianopsia of the left eye secondary to chiasmatic invasion. RESULTS: Diagnosis of retinoblastoma infiltration was confirmed by stereotactic biopsy of the chiasmatic lesion. Treatment with intravenous and intrathecal chemotherapy led to partial remission, and was followed by stereotactic irradiation of the chiasmatic mass and right optic nerve. The left eye was enucleated. Death occurred one year later due to cerebrospinal fluid metastases. CONCLUSION: Extraocular extension of retinoblastoma diagnosed in adulthood has never, to our knowledge, been reported. This case stresses the importance of lifelong retinoma monitoring and the necessity for radical treatment in the event of malignant transformation.
Resumo:
BACKGROUND: Endovascular treatment for acute ischemic stroke patients was recently shown to improve recanalization rates and clinical outcome in a well-defined study population. Intravenous thrombolysis (IVT) alone is insufficiently effective to recanalize in certain patients or of little value in others. Accordingly, we aimed at identifying predictors of recanalization in patients treated with or without IVT. METHODS: In the observational Acute Stroke Registry and Analysis of Lausanne (ASTRAL) registry, we selected those stroke patients (1) with an arterial occlusion on computed tomography angiography (CTA) imaging, (2) who had an arterial patency assessment at 24 hours (CTA/magnetic resonance angiography/transcranial Doppler), and (3) who were treated with IVT or had no revascularization treatment. Based on 2 separate logistic regression analyses, predictors of spontaneous and post-thrombolytic recanalization were generated. RESULTS: Partial or complete recanalization was achieved in 121 of 210 (58%) thrombolyzed patients. Recanalization was associated with atrial fibrillation (odds ratio , 1.6; 95% confidence interval, 1.2-3.0) and absence of early ischemic changes on CT (1.1, 1.1-1.2) and inversely correlated with the presence of a significant extracranial (EC) stenosis or occlusion (.6, .3-.9). In nonthrombolyzed patients, partial or complete recanalization was significantly less frequent (37%, P < .01). The recanalization was independently associated with a history of hypercholesterolemia (2.6, 1.2-5.6) and the proximal site of the intracranial occlusion (2.5, 1.2-5.4), and inversely correlated with a decreased level of consciousness (.3, .1-.8), and EC (.3, .1-.6) and basilar artery pathology (.1, .0-.6). CONCLUSIONS: Various clinical findings, cardiovascular risk factors, and arterial pathology on acute CTA-based imaging are moderately associated with spontaneous and post-thrombolytic arterial recanalization at 24 hours. If confirmed in other studies, this information may influence patient selection toward the most appropriate revascularization strategy.
2nd ESMO Consensus Conference in Lung Cancer: locally advanced stage III non-small-cell lung cancer.
Resumo:
To complement the existing treatment guidelines for all tumour types, ESMO organises consensus conferences to focus on specific issues in each type of tumour. The 2nd ESMO Consensus Conference on Lung Cancer was held on 11-12 May 2013 in Lugano. A total of 35 experts met to address several questions on non-small-cell lung cancer (NSCLC) in each of four areas: pathology and molecular biomarkers, first-line/second and further lines of treatment in advanced disease, early-stage disease and locally advanced disease. For each question, recommendations were made including reference to the grade of recommendation and level of evidence. This consensus paper focuses on locally advanced disease.
Resumo:
PURPOSE: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. METHODS: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. RESULTS: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25-30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. CONCLUSIONS: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.
Resumo:
OBJECTIVE: This study aimed to assess the long-term outcome of functional endoscopic sinus surgery for Samter's triad patients using an objective visual analogue scale and nasal endoscopy. METHOD: Using a retrospective database, 33 Samter's triad patients who underwent functional endoscopic sinus surgery were evaluated pre- and post-operatively between 1987 and 2007 in Hospital of La Chaux-de-Fonds, Switzerland. RESULTS: A total of 33 patients participated in the study, and the mean follow-up period was 11.6 years (range 1.2-20 years). Patients were divided into two groups based on visual analogue scale scores of the five parameters with the greatest difference in intensity of symptoms between the beginning and end of follow up. Group 1 included patients with a mean visual analogue scale score of 6 and below at the end of follow up and group 2 included patients with a mean visual analogue scale score of more than 6. The only statistically significant difference noted between the two groups was the endonasal findings: stage III-IV polyposis was present in 1 out of 24 patients (4 per cent) in group 1 and in 5 out of 9 patients (56 per cent) in group 2. CONCLUSION: The results of our study indicate that functional endoscopic sinus surgery helps stabilise disease progression. Stage III-IV polyposis had a significant adverse effect on long-term outcome.
Resumo:
Pregnant women are exposed to an increased risk for developing pulmonary embolism (PE), a main cause for maternal mortality. Surgical pulmonary embolectomy is one important therapeutic and potential life-saving armamentarium, considering pregnancy as a relative contraindication for thrombolysis. We present a case of a 36-year-old woman with massive bilateral PE after emergent caesarean delivery, requiring reanimation by external heart massage. The onset of massive intrauterine bleeding contraindicated thrombolysis and emergency surgical pulmonary embolectomy, followed by a hysterectomy, were preformed successfully. Acute surgical pulmonary embolectomy may be an option in critically diseased high-risk patients, requiring a multiteam approach, and should be part of the therapeutic armamentarium of the attending cardiac surgeon.
Resumo:
Le cancer testiculaire, bien que peu fréquent, revêt une importance particulière en oncologie ; il représente actuellement un modèle pour optimiser un suivi radiologique tout en essayant de diminuer l'apparition de tumeurs radio-induites.En effet, cette pathologie présente un taux très élevé de survie nécessitant, au vu du jeune âge des patients, des bilans radiologiques à long terme, auxquels pourront être liés des effets secondaires, en particulier les tumeurs secondaires.Afin de diminuer cela, les recommandations de prise en charge ont évolué et les protocoles de radiologie s'améliorent afin d'exposer à moins de rayonnements ionisants pour un résultat identique.Il est donc devenu primordial de maintenir un suivi optimal tout en essayant d'en minimiser la toxicité. Despite being rare cancers, testicular seminoma and non-seminoma play an important role in oncology: they represent a model on how to optimize radiological follow-up, aiming at a lowest possible radiation exposure and secondary cancer risk. Males diagnosed with testicular cancer undergo frequently prolonged follow-up with CT-scans with potential toxic side effects, in particular secondary cancers. To reduce the risks linked to ionizing radiation, precise follow-up protocols have been developed. The number of recommended CT-scanners has been significantly reduced over the last 10 years. The CT scanners have evolved technically and new acquisition protocols have the potential to reduce the radiation exposure further.
Resumo:
UNLABELLED: Bone microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) was assessed in adult patients with mild, moderate, and severe osteogenesis imperfecta (OI). The trabecular bone score (TBS), bone mineral density (BMD) by dual-energy X-ray absorptiometry (DXA), and dual X-ray and laser (DXL) at the calcaneus were likewise assessed in patients with OI. Trabecular microstructure and BMD in particular were severely altered in patients with OI. INTRODUCTION: OI is characterized by high fracture risk but not necessarily by low BMD. The main purpose of this study was to assess bone microarchitecture and BMD at different skeletal sites in different types of OI. METHODS: HR-pQCT was performed in 30 patients with OI (mild OI-I, n = 18 (41.8 [34.7, 55.7] years) and moderate to severe OI-III-IV, n = 12 (47.6 [35.3, 58.4] years)) and 30 healthy age-matched controls. TBS, BMD by DXA at the lumbar spine and hip, as well as BMD by DXL at the calcaneus were likewise assessed in patients with OI only. RESULTS: At the radius, significantly lower trabecular parameters including BV/TV (p = 0.01 and p < 0.0001, respectively) and trabecular number (p < 0.0001 and p < 0.0001, respectively) as well as an increased inhomogeneity of the trabecular network (p < 0.0001 and p < 0.0001, respectively) were observed in OI-I and OI-III-IV in comparison to the control group. Similar results for trabecular parameters were found at the tibia. Microstructural parameters were worse in OI-III-IV than in OI-I. No significant differences were found in cortical thickness and cortical porosity between the three subgroups at the radius. The cortical thickness of the tibia was thinner in OI-I (p < 0.001), but not OI-III-IV, when compared to controls. CONCLUSIONS: Trabecular BMD and trabecular bone microstructure in particular are severely altered in patients with clinical OI-I and OI-III-IV. Low TBS and DXL and their significant associations to HR-pQCT parameters of trabecular bone support this conclusion.
Resumo:
Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.
Resumo:
For decades, lung cancer has been the most common cancer in terms of both incidence and mortality. There has been very little improvement in the prognosis of lung cancer. Early treatment following early diagnosis is considered to have potential for development. The National Lung Screening Trial (NLST), a large, well-designed randomized controlled trial, evaluated low-dose computed tomography (LDCT) as a screening tool for lung cancer. Compared with chest X-ray, annual LDCT screening reduced death from lung cancer and overall mortality by 20 and 6.7 %, respectively, in high-risk people aged 55-74 years. Several smaller trials of LDCT screening are under way, but none are sufficiently powered to detect a 20 % reduction in lung cancer death. Thus, it is very unlikely that the NLST results will be replicated. In addition, the NLST raises several issues related to screening, such as the high false-positive rate, overdiagnosis and cost. Healthcare providers and systems are now left with the question of whether the available findings should be translated into practice. We present the main reasons for implementing lung cancer screening in high-risk adults and discuss the main issues related to lung cancer screening. We stress the importance of eligibility criteria, smoking cessation programs, primary care physicians, and informed-decision making should lung cancer screening be implemented. Seven years ago, we were waiting for the results of trials. Such evidence is now available. Similar to almost all other cancer screens, uncertainties exist and persist even after recent scientific efforts and data. We believe that by staying within the characteristics of the original trial and appropriately sharing the evidence as well as the uncertainties, it is reasonable to implement a LDCT lung cancer screening program for smokers and former smokers.
Resumo:
OBJECTIVES: To determine inter-session and intra/inter-individual variations of the attenuations of aortic blood/myocardium with MDCT in the context of calcium scoring. To evaluate whether these variations are dependent on patients' characteristics. METHODS: Fifty-four volunteers were evaluated with calcium scoring non-enhanced CT. We measured attenuations (inter-individual variation) and standard deviations (SD, intra-individual variation) of the blood in the ascending aorta and of the myocardium of left ventricle. Every volunteer was examined twice to study the inter-session variation. The fat pad thickness at the sternum and noise (SD of air) were measured too. These values were correlated with the measured aortic/ventricular attenuations and their SDs (Pearson). Historically fixed thresholds (90 and 130 HU) were tested against different models based on attenuations of blood/ventricle. RESULTS: The mean attenuation was 46 HU (range, 17-84 HU) with mean SD 23 HU for the blood, and 39 HU (10-82 HU) with mean SD 18 HU for the myocardium. The attenuation/SD of the blood were significantly higher than those of the myocardium (p < 0.01). The inter-session variation was not significant. There was a poor correlation between SD of aortic blood/ventricle with fat thickness/noise. Based on existing models, 90 HU threshold offers a confidence interval of approximately 95% and 130 HU more than 99%. CONCLUSIONS: Historical thresholds offer high confidence intervals for exclusion of aortic blood/myocardium and by the way for detecting calcifications. Nevertheless, considering the large variations of blood/myocardium CT values and the influence of patient's characteristics, a better approach might be an adaptive threshold.
Resumo:
Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.
Resumo:
Right ventricular (RV) rupture in cases of mediastinitis following cardiac surgery is a rare and dangerous complication. Bleeding from the right ventricle occurs mainly after sternal reopening, due to either iatrogenic manipulation (wire removal, lesions due to wiring maneuvers) or mechanical shearing forces, producing direct injury. We present a case of RV wall perforation due to infection in a recurrent postoperative mediastinitis with a closed chest. The current literature on treatment of postoperative mediastinitis is also reviewed.
Resumo:
La tomodensitométrie (TDM) est une technique d'imagerie pour laquelle l'intérêt n'a cessé de croitre depuis son apparition au début des années 70. De nos jours, l'utilisation de cette technique est devenue incontournable, grâce entre autres à sa capacité à produire des images diagnostiques de haute qualité. Toutefois, et en dépit d'un bénéfice indiscutable sur la prise en charge des patients, l'augmentation importante du nombre d'examens TDM pratiqués soulève des questions sur l'effet potentiellement dangereux des rayonnements ionisants sur la population. Parmi ces effets néfastes, l'induction de cancers liés à l'exposition aux rayonnements ionisants reste l'un des risques majeurs. Afin que le rapport bénéfice-risques reste favorable au patient il est donc nécessaire de s'assurer que la dose délivrée permette de formuler le bon diagnostic tout en évitant d'avoir recours à des images dont la qualité est inutilement élevée. Ce processus d'optimisation, qui est une préoccupation importante pour les patients adultes, doit même devenir une priorité lorsque l'on examine des enfants ou des adolescents, en particulier lors d'études de suivi requérant plusieurs examens tout au long de leur vie. Enfants et jeunes adultes sont en effet beaucoup plus sensibles aux radiations du fait de leur métabolisme plus rapide que celui des adultes. De plus, les probabilités des évènements auxquels ils s'exposent sont également plus grandes du fait de leur plus longue espérance de vie. L'introduction des algorithmes de reconstruction itératifs, conçus pour réduire l'exposition des patients, est certainement l'une des plus grandes avancées en TDM, mais elle s'accompagne de certaines difficultés en ce qui concerne l'évaluation de la qualité des images produites. Le but de ce travail est de mettre en place une stratégie pour investiguer le potentiel des algorithmes itératifs vis-à-vis de la réduction de dose sans pour autant compromettre la qualité du diagnostic. La difficulté de cette tâche réside principalement dans le fait de disposer d'une méthode visant à évaluer la qualité d'image de façon pertinente d'un point de vue clinique. La première étape a consisté à caractériser la qualité d'image lors d'examen musculo-squelettique. Ce travail a été réalisé en étroite collaboration avec des radiologues pour s'assurer un choix pertinent de critères de qualité d'image. Une attention particulière a été portée au bruit et à la résolution des images reconstruites à l'aide d'algorithmes itératifs. L'analyse de ces paramètres a permis aux radiologues d'adapter leurs protocoles grâce à une possible estimation de la perte de qualité d'image liée à la réduction de dose. Notre travail nous a également permis d'investiguer la diminution de la détectabilité à bas contraste associée à une diminution de la dose ; difficulté majeure lorsque l'on pratique un examen dans la région abdominale. Sachant que des alternatives à la façon standard de caractériser la qualité d'image (métriques de l'espace Fourier) devaient être utilisées, nous nous sommes appuyés sur l'utilisation de modèles d'observateurs mathématiques. Nos paramètres expérimentaux ont ensuite permis de déterminer le type de modèle à utiliser. Les modèles idéaux ont été utilisés pour caractériser la qualité d'image lorsque des paramètres purement physiques concernant la détectabilité du signal devaient être estimés alors que les modèles anthropomorphes ont été utilisés dans des contextes cliniques où les résultats devaient être comparés à ceux d'observateurs humain, tirant profit des propriétés de ce type de modèles. Cette étude a confirmé que l'utilisation de modèles d'observateurs permettait d'évaluer la qualité d'image en utilisant une approche basée sur la tâche à effectuer, permettant ainsi d'établir un lien entre les physiciens médicaux et les radiologues. Nous avons également montré que les reconstructions itératives ont le potentiel de réduire la dose sans altérer la qualité du diagnostic. Parmi les différentes reconstructions itératives, celles de type « model-based » sont celles qui offrent le plus grand potentiel d'optimisation, puisque les images produites grâce à cette modalité conduisent à un diagnostic exact même lors d'acquisitions à très basse dose. Ce travail a également permis de clarifier le rôle du physicien médical en TDM: Les métriques standards restent utiles pour évaluer la conformité d'un appareil aux requis légaux, mais l'utilisation de modèles d'observateurs est inévitable pour optimiser les protocoles d'imagerie. -- Computed tomography (CT) is an imaging technique in which interest has been quickly growing since it began to be used in the 1970s. Today, it has become an extensively used modality because of its ability to produce accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase in the number of CT examinations performed has raised concerns about the potential negative effects of ionising radiation on the population. Among those negative effects, one of the major risks remaining is the development of cancers associated with exposure to diagnostic X-ray procedures. In order to ensure that the benefits-risk ratio still remains in favour of the patient, it is necessary to make sure that the delivered dose leads to the proper diagnosis without producing unnecessarily high-quality images. This optimisation scheme is already an important concern for adult patients, but it must become an even greater priority when examinations are performed on children or young adults, in particular with follow-up studies which require several CT procedures over the patient's life. Indeed, children and young adults are more sensitive to radiation due to their faster metabolism. In addition, harmful consequences have a higher probability to occur because of a younger patient's longer life expectancy. The recent introduction of iterative reconstruction algorithms, which were designed to substantially reduce dose, is certainly a major achievement in CT evolution, but it has also created difficulties in the quality assessment of the images produced using those algorithms. The goal of the present work was to propose a strategy to investigate the potential of iterative reconstructions to reduce dose without compromising the ability to answer the diagnostic questions. The major difficulty entails disposing a clinically relevant way to estimate image quality. To ensure the choice of pertinent image quality criteria this work was continuously performed in close collaboration with radiologists. The work began by tackling the way to characterise image quality when dealing with musculo-skeletal examinations. We focused, in particular, on image noise and spatial resolution behaviours when iterative image reconstruction was used. The analyses of the physical parameters allowed radiologists to adapt their image acquisition and reconstruction protocols while knowing what loss of image quality to expect. This work also dealt with the loss of low-contrast detectability associated with dose reduction, something which is a major concern when dealing with patient dose reduction in abdominal investigations. Knowing that alternative ways had to be used to assess image quality rather than classical Fourier-space metrics, we focused on the use of mathematical model observers. Our experimental parameters determined the type of model to use. Ideal model observers were applied to characterise image quality when purely objective results about the signal detectability were researched, whereas anthropomorphic model observers were used in a more clinical context, when the results had to be compared with the eye of a radiologist thus taking advantage of their incorporation of human visual system elements. This work confirmed that the use of model observers makes it possible to assess image quality using a task-based approach, which, in turn, establishes a bridge between medical physicists and radiologists. It also demonstrated that statistical iterative reconstructions have the potential to reduce the delivered dose without impairing the quality of the diagnosis. Among the different types of iterative reconstructions, model-based ones offer the greatest potential, since images produced using this modality can still lead to an accurate diagnosis even when acquired at very low dose. This work has clarified the role of medical physicists when dealing with CT imaging. The use of the standard metrics used in the field of CT imaging remains quite important when dealing with the assessment of unit compliance to legal requirements, but the use of a model observer is the way to go when dealing with the optimisation of the imaging protocols.