948 resultados para RADIATION-DOSE DISTRIBUTIONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Undergraduate students studying the Bachelor of Radiation Therapy at Queensland University of Technology (QUT) attend clinical placements in a number of department sites across Queensland. To ensure that the curriculum prepares students for the most common treatments and current techniques in use in these departments, a curriculum matching exercise was performed. Methods: A cross-sectional census was performed on a pre-determined “Snapshot” date in 2012. This was undertaken by the clinical education staff in each department who used a standardized proforma to count the number of patients as well as prescription, equipment, and technique data for a list of tumour site categories. This information was combined into aggregate anonymized data. Results: All 12 Queensland radiation therapy clinical sites participated in the Snapshot data collection exercise to produce a comprehensive overview of clinical practice on the chosen day. A total of 59 different tumour sites were treated on the chosen day and as expected the most common treatment sites were prostate and breast, comprising 46% of patients treated. Data analysis also indicated that intensity-modulated radiotherapy (IMRT) use is relatively high with 19.6% of patients receiving IMRT treatment on the chosen day. Both IMRT and image-guided radiotherapy (IGRT) indications matched recommendations from the evidence. Conclusion: The Snapshot method proved to be a feasible and efficient method of gathering useful

Relevância:

20.00% 20.00%

Publicador:

Resumo:

QUT Bachelor of Radiation Therapy students progress from first visiting a radiation therapy department to graduation and progression into the NPDP over a span of three years. Although there are clear guidelines as to expected competency level post-NPDP, there is still a variety of perceived levels prior to this. Staff and students feedback both suggest that different centres and within centres different staff have differing opinions of these levels. Indeed, many staff members object to the use of the word “competency” for a pre-NPODP undergraduate, preferring the term “achievement”. While it is acknowledged that students progress at different rates, it is vitally important for equity that staff expectations of students at different academic levels are identical. Provision of guidelines for different stages of progression are essential for equitable assessment and most assessments, including the NRTAT are complemented by statements to enable level to be determined. For the University-specific competency assessments some level of consensus between clinical staff is required, especially where students are placed at a large number of different placement sites. Aims The main aim of this initial study is to gauge staff opinions of levels of student progression in order to judge cross-centres consistency. A secondary objective is to evaluate the degree of correlation between staff seniority and perception of student levels. Informal feedback suggests that staff at or just post NPDP level have a different perception of student competency expectations than more senior staff. If these perceptions change with level it will make agreement of guidelines statements more challenging. Study Methods A standard evaluation questionnaire was provided to RT staff participating in ongoing updates to clinical assessment. As part of curriculum development staff were asked to provide anonymous and optional answers to further questions in order to audit current practice. This involved assigning level of student progression to different statements relating to tasks or competencies. After data collation, scores were assigned to level and totals used to rank statements according to perceived student level. Descriptive statistical analysis was used to identify which statements were easier to assign to student level and which were more ambiguous. Further sub-analysis was performed for each category of staff seniority to judge differences in perception. Strength of correlation between seniority and expectation was calculated to confirm or contradict the informal feedback. Results By collating different staff perceptions of competencies for different student levels commonly agreed statements can be used to define achievement level. This presentation outlines the results of the audit including statements that most staff perceived as relevant to a specific student group and statements that staff found to be harder to attribute. Strength of correlation between staff perception and seniority will be outlined where statistically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the use of fiducial markers (FMs) for the localisation of the prostate during external beam radiation therapy (EBRT) has become part of routine practice, radiation therapists (RTs) have become increasingly responsible for online image interpretation. The aim of this investigation was to quantify the limits of agreement (LoA) between RTs when localising to FMs with orthogonal kilovoltage (kV) imaging. Methods Six patients receiving prostate EBRT utilising FMs were included in this study. Treatment localisation was performed using kV imaging prior to each fraction. Online stereoscopic assessment of FMs, performed by the treating RTs, was compared with the offline assessment by three RTs. Observer agreement was determined by pairwise Bland-Altman analysis. Results Stereoscopic analysis of 225 image pairs was performed online at the time of treatment, and offline by three RT observers. Eighteen pairwise Bland-Altman analyses were completed to assess the level of agreement between observers. Localisation by RTs was found to be within clinically acceptable 95% LoAs. Conclusions Small differences between RTs, in both the online and offline setting, were found to be within clinically acceptable limits. RTs were able to make consistent and reliable judgements when matching FMs on planar kV imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Individual exposure to ultraviolet radiation (UVR) is challenging to measure, particularly for diseases with substantial latency periods between first exposure and diagnosis of outcome, such as cancer. To guide the choice of surrogates for long-term UVR exposure in epidemiologic studies, we assessed how well stable sun-related individual characteristics and environmental/meteorological factors predicted daily personal UVR exposure measurements. Methods We evaluated 123 United States Radiologic Technologists subjects who wore personal UVR dosimeters for 8 hours daily for up to 7 days (N = 837 days). Potential predictors of personal UVR derived from a self-administered questionnaire, and public databases that provided daily estimates of ambient UVR and weather conditions. Factors potentially related to personal UVR exposure were tested individually and in a model including all significant variables. Results The strongest predictors of daily personal UVR exposure in the full model were ambient UVR, latitude, daily rainfall, and skin reaction to prolonged sunlight (R2 = 0.30). In a model containing only environmental and meteorological variables, ambient UVR, latitude, and daily rainfall were the strongest predictors of daily personal UVR exposure (R2 = 0.25). Conclusions In the absence of feasible measures of individual longitudinal sun exposure history, stable personal characteristics, ambient UVR, and weather parameters may help estimate long-term personal UVR exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The risk of vitamin D insufficiency is increased in persons having limited sunlight exposure and dietary vitamin D. Supplementation compliance might be improved with larger doses taken less often, but this may increase the potential for side effects. The objective of the present study was to determine whether a weekly or weekly/monthly regimen of vitamin D supplementation is as effective as daily supplementation without increasing the risk of side effects. Participants were forty-eight healthy adults who were randomly assigned for 3 months to placebo or one of three supplementation regimens: 50 μg/d (2000 IU/d, analysed dose 70 μg/d), 250 μg/week (10 000 IU/week, analysed dose 331 μg/week) or 1250 μg/week (50 000 IU/week, analysed dose 1544 μg/week) for 4 weeks and then 1250 μg/month for 2 months. Daily and weekly doses were equally effective at increasing serum 25-hydroxyvitamin D, which was significantly greater than baseline in all the supplemented groups after 30 d of treatment. Subjects in the 1250 μg treatment group, who had a BMI >26 kg/m2, had a steady increase in urinary Ca in the first 3 weeks of supplementation, and, overall, the relative risk of hypercalciuria was higher in the 1250 μg group than in the placebo group (P= 0·01). Although vitamin D supplementation remains a controversial issue, these data document that supplementing with ≤ 250 μg/week ( ≤ 10 000 IU/week) can improve or maintain vitamin D status in healthy populations without the risk of hypercalciuria, but 24 h urinary Ca excretion should be evaluated in healthy persons receiving vitamin D3 supplementation in weekly single doses of 1250 μg (50 000 IU).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using Monte Carlo simulation for radiotherapy dose calculation can provide more accurate results when compared to the analytical methods usually found in modern treatment planning systems, especially in regions with a high degree of inhomogeneity. These more accurate results acquired using Monte Carlo simulation however, often require orders of magnitude more calculation time so as to attain high precision, thereby reducing its utility within the clinical environment. This work aims to improve the utility of Monte Carlo simulation within the clinical environment by developing techniques which enable faster Monte Carlo simulation of radiotherapy geometries. This is achieved principally through the use new high performance computing environments and simpler alternative, yet equivalent representations of complex geometries. Firstly the use of cloud computing technology and it application to radiotherapy dose calculation is demonstrated. As with other super-computer like environments, the time to complete a simulation decreases as 1=n with increasing n cloud based computers performing the calculation in parallel. Unlike traditional super computer infrastructure however, there is no initial outlay of cost, only modest ongoing usage fees; the simulations described in the following are performed using this cloud computing technology. The definition of geometry within the chosen Monte Carlo simulation environment - Geometry & Tracking 4 (GEANT4) in this case - is also addressed in this work. At the simulation implementation level, a new computer aided design interface is presented for use with GEANT4 enabling direct coupling between manufactured parts and their equivalent in the simulation environment, which is of particular importance when defining linear accelerator treatment head geometry. Further, a new technique for navigating tessellated or meshed geometries is described, allowing for up to 3 orders of magnitude performance improvement with the use of tetrahedral meshes in place of complex triangular surface meshes. The technique has application in the definition of both mechanical parts in a geometry as well as patient geometry. Static patient CT datasets like those found in typical radiotherapy treatment plans are often very large and present a significant performance penalty on a Monte Carlo simulation. By extracting the regions of interest in a radiotherapy treatment plan, and representing them in a mesh based form similar to those used in computer aided design, the above mentioned optimisation techniques can be used so as to reduce the time required to navigation the patient geometry in the simulation environment. Results presented in this work show that these equivalent yet much simplified patient geometry representations enable significant performance improvements over simulations that consider raw CT datasets alone. Furthermore, this mesh based representation allows for direct manipulation of the geometry enabling motion augmentation for time dependant dose calculation for example. Finally, an experimental dosimetry technique is described which allows the validation of time dependant Monte Carlo simulation, like the ones made possible by the afore mentioned patient geometry definition. A bespoke organic plastic scintillator dose rate meter is embedded in a gel dosimeter thereby enabling simultaneous 3D dose distribution and dose rate measurement. This work demonstrates the effectiveness of applying alternative and equivalent geometry definitions to complex geometries for the purposes of Monte Carlo simulation performance improvement. Additionally, these alternative geometry definitions allow for manipulations to be performed on otherwise static and rigid geometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Despite the technologic advances, radiation dermatitis is still a prevalent and distressing symptom in patients with cancer undergoing radiotherapy. Systematic reviews (SRs) are regarded as level I evidence providing direction for clinical practice and guidelines. This overview aims to provide a critical appraisal of SRs published on interventions for the prevention/management of radiation dermatitis. Methodology: We searched the following electronic databases: MEDLINE, CINAHL, EMBASE, and the Cochrane Library (up to Feb 2012). We also hand-searched reference lists of potentially eligible articles and a number of key journals in the area. Two authors screened all potential articles and included eligible SRs. Two authors critically appraised and extracted key findings from the included reviews using the “A Measurement Tool to Assess Systematic Reviews” (AMSTAR). Results: Of 1837 potential titles, six SRs were included. A number of interventions have been reported to be potentially beneficial for managing radiation dermatitis. Interventions evaluated in these reviews included skin care advice, steroidal/non-steroidal topical agents, systematic therapies, modes of radiation delivery, and dressings. However, all the included SRs reported that there is insufficient evidence supporting any single effective intervention. The methodological quality of the included studies varied, and methodological shortfalls in these reviews may create biases to the overall results or recommendations for clinical practice. Conclusions and implications: An up-to-date high quality SR in preventing/managing radiation dermatitis is needed to guide practice and direction for future research. Clinicians or guideline developers are recommended to critically evaluate the information of SRs in their decision making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Air pollution is a widespread health problem associated with respiratory symptoms. Continuous exposure monitoring was performed to estimate alveolar and tracheobronchial dose, measured as deposited surface area, for 103 children and to evaluate the long-term effects of exposure to airborne particles through spirometry, skin prick tests and measurement of exhaled nitric oxide (eNO). The mean daily alveolar deposited surface area dose received by children was 1.35×103 mm2. The lowest and highest particle number concentrations were found during sleeping and eating time. A significant negative association was found between changes in pulmonary function tests and individual dose estimates. Significant differences were found for asthmatics, children with allergic rhinitis and sensitive to allergens compared to healthy subjects for eNO. Variation is a child’s activity over time appeared to have a strong impact on respiratory outcomes, which indicates that personal monitoring is vital for assessing the expected health effects of exposure to particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The use of amorphous-silicon electronic portal imaging devices (a-Si EPIDs) for dosimetry is complicated by the effects of scattered radiation. In photon radiotherapy, primary signal at the detector can be accompanied by photons scattered from linear accelerator components, detector materials, intervening air, treatment room surfaces (floor, walls, etc) and from the patient/phantom being irradiated. Consequently, EPID measurements which presume to take scatter into account are highly sensitive to the identification of these contributions. One example of this susceptibility is the process of calibrating an EPID for use as a gauge of (radiological) thickness, where specific allowance must be made for the effect of phantom-scatter on the intensity of radiation measured through different thicknesses of phantom. This is usually done via a theoretical calculation which assumes that phantom scatter is linearly related to thickness and field-size. We have, however, undertaken a more detailed study of the scattering effects of fields of different dimensions when applied to phantoms of various thicknesses in order to derive scattered-primary ratios (SPRs) directly from simulation results. This allows us to make a more-accurate calibration of the EPID, and to qualify the appositeness of the theoretical SPR calculations. Methods: This study uses a full MC model of the entire linac-phantom-detector system simulated using EGSnrc/BEAMnrc codes. The Elekta linac and EPID are modelled according to specifications from the manufacturer and the intervening phantoms are modelled as rectilinear blocks of water or plastic, with their densities set to a range of physically realistic and unrealistic values. Transmissions through these various phantoms are calculated using the dose detected in the model EPID and used in an evaluation of the field-size-dependence of SPR, in different media, applying a method suggested for experimental systems by Swindell and Evans [1]. These results are compared firstly with SPRs calculated using the theoretical, linear relationship between SPR and irradiated volume, and secondly with SPRs evaluated from our own experimental data. An alternate evaluation of the SPR in each simulated system is also made by modifying the BEAMnrc user code READPHSP, to identify and count those particles in a given plane of the system that have undergone a scattering event. In addition to these simulations, which are designed to closely replicate the experimental setup, we also used MC models to examine the effects of varying the setup in experimentally challenging ways (changing the size of the air gap between the phantom and the EPID, changing the longitudinal position of the EPID itself). Experimental measurements used in this study were made using an Elekta Precise linear accelerator, operating at 6MV, with an Elekta iView GT a-Si EPID. Results and Discussion: 1. Comparison with theory: With the Elekta iView EPID fixed at 160 cm from the photon source, the phantoms, when positioned isocentrically, are located 41 to 55 cm from the surface of the panel. At this geometry, a close but imperfect agreement (differing by up to 5%) can be identified between the results of the simulations and the theoretical calculations. However, this agreement can be totally disrupted by shifting the phantom out of the isocentric position. Evidently, the allowance made for source-phantom-detector geometry by the theoretical expression for SPR is inadequate to describe the effect that phantom proximity can have on measurements made using an (infamously low-energy sensitive) a-Si EPID. 2. Comparison with experiment: For various square field sizes and across the range of phantom thicknesses, there is good agreement between simulation data and experimental measurements of the transmissions and the derived values of the primary intensities. However, the values of SPR obtained through these simulations and measurements seem to be much more sensitive to slight differences between the simulated and real systems, leading to difficulties in producing a simulated system which adequately replicates the experimental data. (For instance, small changes to simulated phantom density make large differences to resulting SPR.) 3. Comparison with direct calculation: By developing a method for directly counting the number scattered particles reaching the detector after passing through the various isocentric phantom thicknesses, we show that the experimental method discussed above is providing a good measure of the actual degree of scattering produced by the phantom. This calculation also permits the analysis of the scattering sources/sinks within the linac and EPID, as well as the phantom and intervening air. Conclusions: This work challenges the assumption that scatter to and within an EPID can be accounted for using a simple, linear model. Simulations discussed here are intended to contribute to a fuller understanding of the contribution of scattered radiation to the EPID images that are used in dosimetry calculations. Acknowledgements: This work is funded by the NHMRC, through a project grant, and supported by the Queensland University of Technology (QUT) and the Royal Brisbane and Women's Hospital, Brisbane, Australia. The authors are also grateful to Elekta for the provision of manufacturing specifications which permitted the detailed simulation of their linear accelerators and amorphous-silicon electronic portal imaging devices. Computational resources and services used in this work were provided by the HPC and Research Support Group, QUT, Brisbane, Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the use of 2- and 3-dimensional cell-based models for studying how skin cells respond to ultraviolet radiation. These methods were used to investigate skin damage and repair after exposure to radiation in the context of skin cancer development. Interactions between different skin cell types were demonstrated as being significant in protecting against ultraviolet radiation-induced skin damage. This has important implications in understanding how skin cancers occur, as well as in the development of new strategies to prevent and treat them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies have demonstrated that exposure to particulate air pollution is associated with several adverse health effects. Recently, interest has focused on ultrafine particles (UFPs, diameter ≤ 100 nm), due to the adverse health effects caused by their ability to induce inflammation and deposit in secondary organs [1]. These effects are much more pronounced in children because they inhale a higher dose of UFPs relative to both lung size (when compared with adults) [2] and increased breathing rates, since they are generally more physically active than adults ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to quantify school children’s exposure to ultrafine particles (UFP) in urban environments. The study was conducted as part of a larger epidemiological project aiming to determine the association between exposures to UFPs and children’s health, titled “Ultrafine Particles from Traffic Emissions and Children’s Health”1 (UPTECH). School children aged 8-11 years old at 24 state schools within the Brisbane Metropolitan Area participated in the present study. This paper presents the methodology and results for calculating deposited UFP surface area in the alveolar region (dose), where UFP deposition is more efficient for particles larger than 6 nm...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique for analysing exhaust emission plumes from unmodified locomotives under real world conditions is described and applied to the task of characterizing plumes from railway trains servicing an Australian shipping port. The method utilizes the simultaneous measurement, downwind of the railway line, of the following pollutants; particle number, PM2.5 mass fraction, SO2, NOx and CO2, with the last of these being used as an indicator of fuel combustion. Emission factors are then derived, in terms of number of particles and mass of pollutant emitted per unit mass of fuel consumed. Particle number size distributions are also presented. The practical advantages of the method are discussed including the capacity to routinely collect emission factor data for passing trains and to thereby build up a comprehensive real world database for a wide range of pollutants. Samples from 56 train movements were collected, analyzed and presented. The quantitative results for emission factors are: EF(N)=(1.7±1)×1016 kg-1, EF(PM2.5)= (1.1±0.5) g·kg-1, EF(NOx)= (28±14) g·kg-1, and EF(SO2 )= (1.4±0.4) g·kg-1. The findings are compared with comparable previously published work. Statistically significant (p<α, α=0.05) correlations within the group of locomotives sampled were found between the emission factors for particle number and both SO2 and NOx.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives This randomised, controlled trial compared the effectiveness of 0.12% chlorhexidine (CHX) gel and 304% fluoride toothpaste to prevent early childhood caries (ECC) in a birth cohort by 24 months. Methods The participants were randomised to receive either (i) twice daily toothbrushing with toothpaste and once daily 0.12% CHX gel (n = 110) or (ii) twice daily toothbrushing with toothpaste only (study controls) (n = 89). The primary outcome measured was caries incidence and the secondary outcome was percentage of children with mutans streptococci (MS). All mothers were contacted by telephone at 6, 12, and 18 months. At 24 months, all children were examined at a community dental clinic. Results At 24 months, the caries prevalence was 5% (3/61) in the CHX and 7% (4/58) in the controls (P = 0.7). There were no differences in percentages of MS-positive children between the CHX and control groups (54%vs 53%). Only 20% applied the CHX gel once daily and 80% less than once daily. Conclusions Toothbrushing using 304% fluoride toothpaste with or without the application of chlorhexidine gel (0.12%) reduces ECC from 23% found in the general community to 5–7%. The lack of effect with chlorhexidine is likely to be due to low compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Prior to 2009, one of the problems faced by radiation therapists who supervised and assessed students on placement in Australian clinical centres, was that each of the six Australian universities where Radiation Therapy (RT) programmes were conducted used different clinical assessment and reporting criteria. This paper describes the development of a unified national clinical assessment and reporting form that was implemented nationally by all six universities in 2009. Methods: A four phase methodology was used to develop the new assessment form and user guide. Phase 1 included university consensus around domains of student practice and assessment, and alignment with national competency standards; Phase 2 was a national consensus workshop attended by radiation therapists involved in student supervision and assessment; Phase 3 was an action research re-iterative Delphi technique involving two rounds of a mail-out to gain further expert consensus; and stage 4 was national piloting of the developed assessment form. Results: The new assessment form includes five main domains of practice and 19 sub-domain criteria which students are assessed against during placement. Feedback from the pilot centre participants was positive, with the new form being assessed to be comprehensive and complemented by the accompanying user guide. Conclusion: The new assessment form has improved both the formative and summative assessment of students on placement, as well as enhancing the quality of feedback to students and the universities. The new national form has high acceptance from the Australian universities and has been subject to wide review by the profession.