888 resultados para Public performance of music


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with the energy consumption and the evaluation of the performance of air supply systems for a ventilated room involving high- and low-level supplies. The energy performance assessment is based on the airflow rate, which is related to the fan power consumption by achieving the same environmental quality performance for each case. Four different ventilation systems are considered: wall displacement ventilation, confluent jets ventilation, impinging jet ventilation and a high level mixing ventilation system. The ventilation performance of these systems will be examined by means of achieving the same Air Distribution Index (ADI) for different cases. The widely used high-level supplies require much more fan power than those for low-level supplies for achieving the same value of ADI. In addition, the supply velocity, hence the supply dynamic pressure, for a high-level supply is much larger than for low-level supplies. This further increases the power consumption for high-level supply systems. The paper considers these factors and attempts to provide some guidelines on the difference in the energy consumption associated with high and low level air supply systems. This will be useful information for designers and to the authors' knowledge there is a lack of information available in the literature on this area of room air distribution. The energy performance of the above-mentioned ventilation systems has been evaluated on the basis of the fan power consumed which is related to the airflow rate required to provide equivalent indoor environment. The Air Distribution Index (ADI) is used to evaluate the indoor environment produced in the room by the ventilation strategy being used. The results reveal that mixing ventilation requires the highest fan power and the confluent jets ventilation needs the lowest fan power in order to achieve nearly the same value of ADI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The high thermal storage capacity of phase change material (PCM) can reduce energy consumption in buildings through energy storage and release when combined with renewable energy sources, night cooling, etc. PCM boards can be used to absorb heat gains during daytime and release heat at night. In this paper, the thermal performance of an environmental chamber fitted with phase change material boards has been investigated. During a full-cycle experiment, i.e. charging–releasing cycle, the PCM boards on a wall can reduce the interior wall surface temperature during the charging process, whereas the PCM wall surface temperature is higher than that of the other walls during the heat releasing process. It is found that the heat flux density of the PCM wall in the melting zone is almost twice as large as that of ordinary wall. Also, the heat-insulation performance of a PCM wall is better than that of an ordinary wall during the charging process, while during the heat discharging process, the PCM wall releases more heat energy. The convective heat transfer coefficient of PCM wall surface calculated using equations for a normal wall material produces an underestimation of this coefficient. The high convective heat transfer coefficient for a PCM wall is due to the increased energy exchange between the wall and indoor air.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the first PFI hospital was established in 1994, many debates centred on the value for money and risk transfer in PFIs. Little concern is shown with PFI hospitals’ performance in delivering healthcare. Exploratory research was carried out to compare PFI with non‐PFI hospital performance. Five performance indicators were analysed to compare differences between PFI and non‐PFI hospitals, namely the length of waiting, the length of stay, MRSA infection rate, C difficile infection rate and patient experience. Data was collected from various government bodies. The results show that only some indexes measuring patient experience emerge statistically significant. This leads to a conclusion that PFI hospitals may not perform better than non‐PFI hospitals but they are not worse than non‐PFI hospitals in the delivery of services. However, future research needs to pay attention to reliability and validity of data sets currently available to undertake comparison.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article discusses inductee music service teachers (to 25 years of age). It explores how their lives, as perceived, shape current identities in teaching and result in several career problems. Respondents were drawn from a comprehensive life history study of 28 Local Education Authority employees. Of this larger cohort, four were age 25 years and below, and the remaining 24 teachers made retrospective comments. Data were collected and analysed between October 2002 and March 2004. Principal findings suggest that schooling failed to address these educators' needs as musical learners; key childhood experiences were external of schools. This often resulted in an idealistic trajectory, in teenage years, towards an occupation as a performer. An occupation in music education was entirely disregarded. Consequently, inductees now consider training experiences an inappropriate platform for their professional lives. Managing group teaching and children's behaviour engenders considerable anxiety. Music service work is also deemed a transient state of affairs. There are implications for training, retention and professional development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four hull-less barley samples were milled on a Buhler MLU 202 laboratory mill and individual and combined milling fractions were characterized. The best milling performance was obtained when the samples were conditioned to 14.3% moisture. Yields were 37-48% for straight-run flour, 47-56% for shorts, and 5-8% for bran. The beta-glucan contents of the straight-run white flours were 1.6-2.1%, of which approximate to49% was water-extractable. The arabinoxylan contents were 1.2-1.5%, of which approximate to17% was water-extractable. Shorts and bran fractions contained more beta-glucan (4.2-5.8% and 3.0-4.7%, respectively) and arabinoxylan (6.1-7.7% and 8.1-11.8%, respectively) than the white flours. For those fractions, beta-glucan extractability was high (58.5 and 52.3%, respectively), whereas arabinoxylan extractability was very low (approximate to6.5 and 2.0%, respectively). The straight-run white flours had low alpha-amylase, beta-glucanase, and endoxylanase activities. The highest alpha-amylase activity was found in the shorts fractions and the highest beta-glucanase and endoxylanase activities were generally found in the bran fractions. Endoxylanase inhibitor activities were low in the white flours and highest in the shorts fractions. High flavanoid, tocopherol, and tocotrienol contents were found in bran and shorts fractions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a region-based algorithm for deriving a concise description of a first order optical flow field. The algorithm described achieves performance improvements over existing algorithms without compromising the accuracy of the flow field values calculated. These improvements are brought about by not computing the entire flow field between two consecutive images, but by considering only the flow vectors of a selected subset of the images. The algorithm is presented in the context of a project to balance a bipedal robot using visual information.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The General Packet Radio Service (GPRS) has been developed for the mobile radio environment to allow the migration from the traditional circuit switched connection to a more efficient packet based communication link particularly for data transfer. GPRS requires the addition of not only the GPRS software protocol stack, but also more baseband functionality for the mobile as new coding schemes have be en defined, uplink status flag detection, multislot operation and dynamic coding scheme detect. This paper concentrates on evaluating the performance of the GPRS coding scheme detection methods in the presence of a multipath fading channel with a single co-channel interferer as a function of various soft-bit data widths. It has been found that compressing the soft-bit data widths from the output of the equalizer to save memory can influence the likelihood decision of the coding scheme detect function and hence contribute to the overall performance loss of the system. Coding scheme detection errors can therefore force the channel decoder to either select the incorrect decoding scheme or have no clear decision which coding scheme to use resulting in the decoded radio block failing the block check sequence and contribute to the block error rate. For correct performance simulation, the performance of the full coding scheme detection must be taken into account.