855 resultados para Polarized double pulses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we consider the T(2) chart with double sampling to control bivariate processes (BDS chart). During the first stage of the sampling, n(1) items of the sample are inspected and two quality characteristics (x; y) are measured. If the Hotelling statistic T(1)(2) for the mean vector of (x; y) is less than w, the sampling is interrupted. If the Hotelling statistic T(1)(2) is greater than CL(1), where CL(1) > w, the control chart signals an out-of-control condition. If w < T(1)(2) <= CL(1), the sampling goes on to the second stage, where the remaining n(2) items of the sample are inspected and T(2)(2) for the mean vector of the whole sample is computed. During the second stage of the sampling, the control chart signals an out-of-control condition when the statistic T(2)(2) is larger than CL(2). A comparative study shows that the BDS chart detects process disturbances faster than the standard bivariate T(2) chart and the adaptive bivariate T(2) charts with variable sample size and/or variable sampling interval.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a new statistic to control the covariance matrix of bivariate processes. This new statistic is based on the sample variances of the two quality characteristics, in short VMAX statistic. The points plotted on the chart correspond to the maximum of the values of these two variances. The reasons to consider the VMAX statistic instead of the generalized variance vertical bar S vertical bar is its faster detection of process changes and its better diagnostic feature; that is, with the VMAX statistic it is easier to identify the out-of-control variable. We study the double sampling (DS) and the exponentially weighted moving average (EWMA) charts based on the VMAX statistic. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Double three-phase transmission lines are analyzed in this paper using a modal transformation model. The main attribute of this model is the use of a single real transformation matrix based on line geometrical characteristics and the Clarke matrix. Because of this, for any line point, the electrical values can be accessed for phase domain or mode domain using the considered transformation matrix and without convolution methods. For non-transposed symmetrical lines the errors between the model results and the exact modes are insignificant values. The eigenvector and eigenvalue analyses for transposed lines search the similarities among the three analyzed transposition types and the possible simplifications for a non-transposed case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eigenvector and eigenvalue analyses are carried out for double three-phase transmission lines, studying the application of a constant and real phase-mode transformation matrix and the errors of this application to mode line models. Employing some line transposition types, exact results are obtained with a single real transformation matrix based on Clarke's matrix and line geometrical characteristics. It is shown that the proposed technique leads to insignificant errors when a nontransposed case is considered. For both cases, transposed and nontransposed, the access to the electrical values (voltage and current, for example) is provided through a simple matrix multiplication without convolution methods. Using this facility, an interesting model for transmission line analysis is obtained even though the nontransposed case errors are not eliminated. The main advantages of the model are related to the transformation matrix: single, real, frequency independent, and identical for voltage and current.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper shows the results of experimental investigations of three-phase banks composed of single-phase transformers and three-phase three-limb core transformers under simultaneous alternating and direct current excitations, for several winding connections. Harmonic analysis of excitation currents for different de saturation levels is performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single real transformation matrices are tested as phase-mode transformation matrices of typical symmetrical systems with double three-phase and two parallel double three-phase transmission lines. These single real transformation matrices are achieved from eigenvector matrices of the mentioned systems and they are based on Clarke's matrix. Using linear combinations of the Clarke's matrix elements, the techniques applied to the single three-phase lines are extended to systems with 6 or 12 phase conductors. For transposed double three-phase lines, phase Z and Y matrices are changed into diagonal matrices in mode domain. Considering non-transposed cases of double three-phase lines, the results are not exact and the error analyses are performed using the exact eigenvalues. In case of two parallel double three-phase lines, the exact single real transformation matrix has not been obtained yet. Searching for this exact matrix, the analyses are based on a single homopolar reference. For all analyses in this paper, the homopolar mode is used as the only homopolar reference for all phase conductors of the studied system. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electric current and the magnetoresistance effect are studied in a double quantum-dot system, where one of the dots QD(a) is coupled to two ferromagnetic electrodes (F-1; F-2), while the second QD(b) is connected to a superconductor S. For energy scales within the superconductor gap, electric conduction is allowed by Andreev reflection processes. Due to the presence of two ferromagnetic leads, non-local crossed Andreev reflections are possible. We found that the magnetoresistance sign can be changed by tuning the external potential applied to the ferromagnets. In addition, it is possible to control the current of the first ferromagnet (F-1) through the potential applied to the second one (F-2). We have also included intradot interaction and gate voltages at each quantum dot and analyzed their influence through a mean field approximation. The interaction reduces the current amplitudes with respect to the non-interacting case, but the switching effect still remains as a manifestation of quantum coherence, in scales of the order of the superconductor coherence length. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4723000]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We herein report a case of a double aortic arch in a 10-week-old male dog of no defined race, which presented episodes of regurgitation at the time of weaning. This vascular malformation was Characterized by the persistence of two aortic arches, right and left, of varying dimensions. The right aortic arch was observed to be larger. During post mortem examination the vessels of the animal were injected with coloured latex bi-centrifuged CIS 1-4 polisopreno which revealed the patency of the two aortic arches. Concomitantly, dilation of the cranial oesophagus causing constriction was observed, indicating megaesophagus, Apart from the constriction, the oesophagus presented normal morphometric parameters in relation to its dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chronic ethanol intake influence on the gluthatione S-transferase (GST-P) and transforming growth factor alpha (TGF-alpha) expression in remodeling/persistent preneoplastic lesions (PNLs) was evaluated in the resistant hepatocyte model. Male Wistar rats were allocated into five groups: G1, non-treated, fed water and chow ad libitum; G2, non-treated and pair-fed chow (restricted to match that of G3 group) and a maltodextrin (MD) solution in tap water (matched ethanol-derived calories); G3, fed 5% ethanol in drinking water and chow ad libitum; G4, diethylnitrosamine (DEN, 200 mg/kg, body weight) plus 200 parts per million of 2-acetylaminofluorene (2-AAF) for 3 weeks and pair-fed chow (restricted to match that of G5 group) and an MD solution in tap water (matched ethanol-derived calories); G5, DEN/2-AAF treatment, fed ethanol 5% and chow ad libitum. All animals were subjected to 70% partial hepatectomy at week 3 and sacrificed at weeks 12 or 22, respectively. Liver samples were collected for histological analysis or immunohistochemical expression of GST-P, TGF-alpha and proliferating cell nuclear antigen or zymography for matrix metalloproteinases-2 and -9. At the end of ethanol treatment, there was a significant increase in the percentage of liver area occupied by persistent GST-P-positive PNLs, the number of TGF-alpha-positive PNLs and the development of liver tumors in ethanol-fed and DEN/2-AAF-treated groups (G5 versus G4, P < 0.001). In addition, ethanol feeding led to a significant increase in cell proliferation mainly in remodeling and persistent PNLs with immunoreactivity for TGF-alpha at week 22 (P < 0.001). Gelatinase activities were not altered by ethanol treatment. The results demonstrated that ethanol enhances the selective growth of PNL with double expression of TGF-alpha and GST-P markers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background the aim of this study was to compare effective and sham intravaginal electrical stimulation (IES) in treating mixed urinary incontinence. Methods. Between January 2001 and February 2002, 40 women were randomly distributed, in a double-blind study, into two groups: group G1 (n = 20), effective IES, and group G2 (n = 20), sham IES, with follow up at one month. Different parameters was studied: 1. clinical questionnaire, 2. body mass index; 3. 60-min pad test; 4. urodynamic study. The protocol of IES consisted of three 20-min sessions per week over a seven-week period. The Dualpex Uro 996 used a frequency of 4 Hz. Results. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence was reduced to 15% in G1 and 31.5% in G2; there was no significant difference between the groups. In the analog wetness and discomfort sensation evaluations were reduced significantly in both groups. The pretreatment urodynamic study showed no statistical difference in urodynamic parameters between the groups. Ten percent of the women presented involuntary detrusor contractions. In the 60-min pad test, there was a significant reduction in both groups. In regards to satisfaction level, after treatment, 80% of G1 patients and 65% of G2 patients were satisfied. There was no statistically significant difference between the groups. Conclusion. Significant improvement was provided by effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)