864 resultados para Pipes, Wooden
Resumo:
Model Submitted by Robert McGraw
Resumo:
Toy Contest
Resumo:
4 of 5
Resumo:
First Prize Detroit News Toy Contest
Resumo:
Locality studies have also been made.
Resumo:
Locality studies have also been made.
Resumo:
Double leaves, oriental style, in case.
Resumo:
cover-title
Resumo:
Appendix to v. 4: Elephant pipes and inscribed tablets in the museum of the Academy of Natural Sciences, Davenport, Iowa. By Charles E. Putnam, p. [253]-347
Resumo:
This report summarizes the data, observations, methods, assumptions, and decisions for the design of the Relief Well Rehabilitation Project in the Right Abutment Drainage Tunnel at Chief Joseph Dam. Chief Joseph Dam (CJD) is a dam on the Columbia River and is owned and operated by the U.S. Army Corps of Engineers (USACE). It is the second only to Grand Coulee dam as the largest producer of hydropower in the United States. The right abutment drainage tunnel contains wooden stave relief wells. Water flows from these wells which reduces the hydrostatic pressure in the right abutment of the dam. The 22 wells in the floor of the tunnel are 60 years old and are in need of rehabilitation. The objective of this project is to control the groundwater gradient, prevent the movement of sediment, stop total screen collapse, and prevent initiation of backwards erosion and piping in the abutment. The rehabilitation solution is to install new stainless steel screens into the existing wells, backfill the annular space between the old wooden screen and the new stainless steel screens with a 3/8-inch pea gravel filter pack, and install a new top cap to hold the new screen in place. This report documents the data, observations, and methods used to complete the final design. During tunnel inspections USACE geologists observed dislodged end plugs and evidence of sediment movement out of the formation. The relief wells have historically high flows between 6,000 gallons per minute (gpm) to 9,000 gpm. New screens are designed based on as-built data and historic tunnel flow. The new screens are 8-in diameter, 100 slot (0.10-inch) screens. We found that screen diameter and slot size would provide adequate transmitting capacity for most of the relief wells. The filter pack gradation is based on descriptions from foundation construction reports. I found that 3/8-inch pea gravel is appropriate for the abutment material. During design, I also considered an option to install the screens into the relief wells without filter pack. I eliminated this option because it did not meet our rehabilitation objective to prevent total failure of the wooden screens.
Resumo:
Understanding, and controlling, the conditions under which calcite precipitates within geothermal energy production systems is a key step in maintaining production efficiency. In this study, I apply methods of bulk and clumped isotope thermometry to an operating geothermal energy facility in northern Nevada to see how those methods can better inform the facility owner, AltaRock Energy, Inc., about the occurrence of calcite scale in their power plant. I have taken water samples from five production wells, the combined generator effluent, shallow cold-water wells, monitoring wells, and surface water. I also collected calcite scale samples from within the production system. Water samples were analyzed for stable oxygen isotope composition (d18O). Calcite samples were analyzed for stable oxygen and carbon (d13C) composition, and clumped isotope composition (D47). With two exceptions, the water compositions are very similar, likely indicating common origin and a well-mixed hydrothermal system. The calcite samples are likewise similar to one another. Apparent temperatures calculated from d18O values of water and calcite are lower than those recorded for the system. Apparent temperatures calculated from D47 are several degrees higher than the recorded well temperatures. The lower temperatures from the bulk isotope data are consistent with temperatures that could be expected during a de-pressurization of the production system, which would cause boiling in the pipes, a reduction in system temperature, and rapid precipitation of calcite scale. However, the high apparent temperature indicated by the D47 data suggests that the calcite is depleted in clumped isotopes given the known temperature of the system, which is inconsistent with this hypothesis. This depletion could instead result from disequilibrium isotopic fractionation during the aforementioned boil events, which would make both the apparent d18O-based and D47-based temperatures unrepresentative of the actual water temperature. This research can help improve our understanding of how isotopic analyses can better inform us about the movement of water through geothermal systems of the past and how it now moves through modern systems. Increased understanding of water movement in these systems could potentially allow for more efficient utilization of geothermal energy as a renewable resource.
Resumo:
There exists a major cost issue as regards termite damage to wooden structures. A factor in this cost has been the increasing trend towards slab-on-ground construction. Current literature has been reviewed in relation to concerns about the possible public/environmental health consequences of the repeated use of termiticides in large quantities. The previous, current and projected future use patterns of termiticides are reviewed in the context of techniques appropriate for termite control and treatment priorities. The phasing out of organochlorine termiticides in Australia was undertaken to minimise impact of these substances on the environment and to a lesser extent on public health. These persistent chemicals were replaced by substances with high activity but relatively low persistence in the soil. There has also been an increase in the use of alternative methods (e.g. physical barriers) for the control of termites. The transition away from organochlorine termiticides has led to a realisation that significant information gaps exist with regard to replacement chemicals and other technologies. Although relatively persistent, the organochlorine chemicals have a limited lifespan in soils. Their concentrations are gradually attenuated by processes such as transport away from the point of application and biodegradation. Wooden structures originally treated with these substances will, with the passing of time, be at risk of termite infestation. The only available option is re-treatment with chemicals currently registered for termite control. Thus, there are likely to be substantial future increases associated with the cost of re-treatment and repairs of older slab-on-ground dwellings. More information is required on Australian termite biology, taxonomy and ecology. The risks of termite infestation need to be evaluated, both locally and nationally so that susceptible or high risk areas, structures and building types can be identified and preventive measures taken in terms of design and construction. Building regulations and designs need to be able to reduce or eliminate high-risk housing; and eliminate or reduce conditions that are attractive to termites and/or facilitate termite infestation.
Resumo:
Unexpected inflation, disinflation or deflation cause arbitrary income transfers between an economy's borrowers and lenders. This redistribution results from distorted real interest rates that are too high when price level changes are over-predicted and too low when they are under-predicted. This article shows that in Australia's case, inflation expectations were mostly biased upwards throughout the 1990s, according to the Melbourne Institute of Applied Economic and Social Research series and to a new derived series based on bond yields, implying that real interest rates were too high over this time. In turn, this caused substantial arbitrary income transfers from debtors to creditors, estimated to have averaged up to 3 per cent of gross domestic product over the period.