994 resultados para Output currents


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neurons generate spikes reliably with millisecond precision if driven by a fluctuating current--is it then possible to predict the spike timing knowing the input? We determined parameters of an adapting threshold model using data recorded in vitro from 24 layer 5 pyramidal neurons from rat somatosensory cortex, stimulated intracellularly by a fluctuating current simulating synaptic bombardment in vivo. The model generates output spikes whenever the membrane voltage (a filtered version of the input current) reaches a dynamic threshold. We find that for input currents with large fluctuation amplitude, up to 75% of the spike times can be predicted with a precision of +/-2 ms. Some of the intrinsic neuronal unreliability can be accounted for by a noisy threshold mechanism. Our results suggest that, under random current injection into the soma, (i) neuronal behavior in the subthreshold regime can be well approximated by a simple linear filter; and (ii) most of the nonlinearities are captured by a simple threshold process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Whole-body water immersion leads to a significant shift of blood from the periphery into the intra-thoracic circulation, followed by an increase in central venous pressure and heart volume. In patients with severely reduced left ventricular function, this hydrostatically in-duced volume shift might overstrain the cardiovascular adaptive mechanisms and lead to cardiac decompensation. The aim of this study is to assess the hemodynamic response to water immer-sion, gymnastics and swimming in patients with heart failure (CHF). Methods We examined 10 patients with compensated CHF (62.9 +/- 6.3 years, EF 31.5 +/- 4.1%, peak VO2 19.4 +/- 2.8 ml/kg/min.), 10 patients with coronary artery disease (CAD) but preserved left ventricular function (57.2 +/- 5.6 years, EF 63.9 +/- 5.5%, peak VO2 28.0 +/- 6.3 ml/kg/min.) and 10 healthy subjects (32.8 +/- 7.2 years, peak VO2 45.6 +/- 6.0 ml/kg/min.). Hemodynamic response to thermo-neutral (32 degrees C) water immersion and exercise was measured using a non-invasive foreign gas rebreathing method during stepwise water immersion, water gymnastics and swimming. Results Water immersion up to the chest increased cardiac index by 19% in healthy subjects, by 21% in CAD patients and 16% in CHF patients. While some CHF patients showed a decrease of stroke volume during immersion, all subjects were able to increase cardiac index (by 87% in healthy subjects, 77% in CAD patients and 53% in CHF patients). Oxygen uptake during swim-ming was 9.7 +/- 3.3 ml/kg/min. in CHF patients, 12.4 +/- 3.5 ml/kg/min. in CAD patients and 13.9 +/- 4.0 ml/kg/min. in healthy subjects. Conclusions Patients with severely reduced left ventricular function but stable clinical conditions and a minimal peak VO2 of at least 15 ml/kg/min. during a symptom-limited exercise stress test tolerate water immersion and swimming in thermo-neutral water well. Although cardiac in-dex and oxygen uptake are lower compared with CAD patients with preserved left ventricular function and healthy controls, these patients are able to increase cardiac index adequately during water immersion and swimming.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Markov chain Monte Carlo is a method of producing a correlated sample in order to estimate features of a complicated target distribution via simple ergodic averages. A fundamental question in MCMC applications is when should the sampling stop? That is, when are the ergodic averages good estimates of the desired quantities? We consider a method that stops the MCMC sampling the first time the width of a confidence interval based on the ergodic averages is less than a user-specified value. Hence calculating Monte Carlo standard errors is a critical step in assessing the output of the simulation. In particular, we consider the regenerative simulation and batch means methods of estimating the variance of the asymptotic normal distribution. We describe sufficient conditions for the strong consistency and asymptotic normality of both methods and investigate their finite sample properties in a variety of examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Skeletal muscular counterpulsation (MCP) has been used as a new noninvasive technique for treatment of low cardiac output. The MCP method is based on ECG-triggered skeletal muscle stimulation. The purpose of the present study was to evaluate acute hemodynamic changes induced by MCP in the experimental animal. METHODS: Eight anaesthetized pigs (43+/-4 kg) were studied at rest and after IV â-blockade (10 mg propranolol) before and after MCP. Muscular counterpulsation was performed on both thighs using trains (75 ms duration) of multiple biphasic electrical impulses with a width of 1 ms and a frequency of 200 Hz at low (10 V) and high (30 V) amplitude. ECG-triggering was used to synchronize stimulation to a given time point. LV pressure-volume relations were determined using the conductance catheter. After baseline measurements, MCP was carried out for 10 minutes at low and high stimulation amplitude. The optimal time point for MCP was determined from LV pressure-volume loops using different stimulation time points during systole and diastole. Best results were observed during end-systole and, therefore, this time point was used for stimulation. RESULTS: Under control conditions, MCP was associated with a significant decrease in pulmonary vascular resistance (-18%), a decrease in systemic vascular resistance (-11%) and stroke work index (-4%), whereas cardiac index (+2%) and ejection fraction (+6%) increased slightly. Pressure-volume loops showed a leftward shift with a decrease in end-systolic volume. After â-blockade, cardiac function decreased (HR, MAP, EF, dP/dt max), but it improved with skeletal muscle stimulation (HR +10% and CI +17%, EF +5%). There was a significant decrease in pulmonary (-19%) and systemic vascular resistance (-29%). CONCLUSIONS: In the animal model, ECG-triggered skeletal muscular counterpulsation is associated with a significant improvement in cardiac function at baseline and after IV â-blockade. Thus, MCP represents a new, non-invasive technique which improves cardiac function by diastolic compression of the peripheral arteries and veins, with a decrease in systemic vascular resistance and increase in cardiac output.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reduced exercise tolerance and dyspnea during exercise are hallmarks of heart failure syndrome. Exercise capacity and various parameters of cardiopulmonary response to exercise are of important prognostic value. All the available parameters only indirectly reflect left ventricular dysfunction and hemodynamic adaptation to an increased demand. Noninvasive assessment of cardiac output, especially during an incremental exercise stress test, would allow the direct measure of cardiac reserve and may become the gold standard for prognostic evaluation in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the fact that mineralocorticoid receptor (MR) antagonist drugs such as spironolactone and eplerenone reduce the mortality in heart failure patients, there is, thus far, no unambiguous demonstration of a functional role of MR in cardiac cells. The aim of this work was to investigate the activation pathway(s) mediating corticosteroid-induced up-regulation of cardiac calcium current (ICa). In this study, using neonatal cardiomyocytes from MR or glucocorticoid receptor (GR) knockout (KO) mice, we show that MR is essential for corticosteroid-induced up-regulation of ICa. This study provides the first direct and unequivocal evidence for MR function in the heart.