985 resultados para Objective Monitoring
Resumo:
Monitoring of internal exposure for nuclear medicine workers requires frequent measurements due to the short physical half-lives of most radionuclides used in this field. The aim of this study was to develop screening measurements performed at the workplace by local staff using standard laboratory instrumentation, to detect whether potential intake has occurred. Such measurements do not enable to determine the committed effective dose, but are adequate to verify that a given threshold is not exceeded. For radioiodine, i.e. (123)I, (124)I, (125)I and (131)I, a calibrated surface contamination monitor is placed in front of the thyroid to detect whether the activity threshold has been exceeded. For radionuclides with very short physical half-lives (≤6 h), such as (99m)Tc and those used in positron emission tomography imaging, i.e. (11)C, (15)O, (18)F and (68)Ga, screening procedures consist in performing daily measurements of the ambient dose rate in front of the abdomen. Other gamma emitters used for imaging, i.e. (67)Ga, (111)In and (201)Tl, are measured with a scintillation detector located in front of the thorax. For pure beta emitters, i.e. (90)Y and (169)Er, as well as beta emitters with low-intensity gamma rays, i.e. (153)Sm, (177)Lu, (186)Re and (188)Re, the procedure consists in measuring hand contamination immediately after use. In Switzerland, screening procedures have been adopted by most nuclear medicine services since such measurements enable an acceptable monitoring while taking into account practical and economic considerations.
Resumo:
Background and objectives In humans, circulating CD4(+)CD25(high) T cells contain mainly regulatory T cells (Treg; FoxP3(+)IL-7R alpha(low)), but a small subset is represented by activated effector T cells (Tact; FoxP3(-)IL-7R alpha(high)). The balance between Tact and Treg may be important after transplantation. The aim of this study was first to analyze and correlate CD4(+)CD25(high) Tact and Treg with the clinical status of kidney transplant recipients and second to study prospectively the effect of two immunosuppressive regimens on Tact/Treg during the first year after transplantation.Design, setting, participants, & measurements CD4(+)CD25(high) Tact and Treg were analyzed by flow cytometry, either retrospectively in 90 patients greater than 1 year after kidney transplantation (cross-sectional analysis) or prospectively in 35 patients receiving two immunosuppressive regimens after kidney transplantation (prospective analysis).Results A higher proportion of Tact and a lower proportion of Treg were found in the majority of kidney recipients. In chronic Immoral rejection, a strikingly higher proportion of Tact was present. A subgroup of stable recipients receiving calcineurin inhibitor-free immunosuppression (mycophenolate mofetil, azathioprine, or sirolimus) had Tact values that were similar to healthy individuals. In the prospective analysis, the proportion of Tact significantly increased in both immunosuppression groups during the first year after transplantation.Conclusions These data highlight distinct patterns in the proportion of circulating Tact depending on the clinical status of kidney recipients. Moreover, the prospective analysis demonstrated an increase in the proportion of Tact, regardless of the immunosuppressive regimen. The measurement of Tact, in addition to Treg, may become a useful immune monitoring tool after kidney transplantation. Clin J Am Soc Nephrol 6: 2025-2033, 2011. doi: 10.2215/CJN.09611010
Resumo:
The objective of this study was to evaluate the effectiveness of Aedes aegyptimass trapping using the sticky trap MosquiTRAP (MQT) by performing a cluster randomised controlled trial in Manaus, state of Amazonas, Brazil. After an initial questionnaire and baseline monitoring of adultAe. aegyptiabundance with BG-Sentinel (BGS) traps in six clusters, three clusters were randomly assigned to the intervention arm where each participating household received three MQTs for mass trapping during 17 months. The remaining three clusters (control arm) did not receive traps. The effect of mass trapping on adult Ae. aegyptiabundance was monitored fortnightly with BGS traps. During the last two months of the study, a serological survey was conducted. After the study, a second questionnaire was applied in the intervention arm. Entomological monitoring indicated that MQT mass trapping did not reduce adult Ae. aegyptiabundance. The serological survey indicated that recent dengue infections were equally frequent in the intervention and the control arm. Most participants responded positively to questions concerning user satisfaction. According to the results, there is no evidence that mass trapping with MQTs can be used as a part of dengue control programs. The use of this sticky trap is only recommendable for dengue vector monitoring.
Resumo:
BACKGROUND In Spain, hospital medicines are assessed and selected by local Pharmacy and Therapeutics committees (PTCs). Of all the drugs assessed, cancer drugs are particularly important because of their budgetary impact and the sometimes arguable added value with respect to existing alternatives. This study analyzed the PTC drug selection process and the main objective was to evaluate the degree of compliance of prescriptions for oncology drugs with their criteria for use. METHODS This was a retrospective observational study (May 2007 to April 2010) of PTC-assessed drugs. The variables measured to describe the committee's activity were number of drugs assessed per year and number of drugs included in any of these settings: without restrictions, with criteria for use, and not included in formulary. These drugs were also analyzed by therapeutic group. To assess the degree of compliance of prescriptions, a score was calculated to determine whether prescriptions for bevacizumab, cetuximab, trastuzumab, and bortezomib were issued in accordance with PTC drug use criteria. RESULTS The PTC received requests for inclusion of 40 drugs, of which 32 were included in the hospital formulary (80.0%). Criteria for use were established for 28 (87.5%) of the drugs included. In total, 293 patients were treated with the four cancer drugs in eight different therapeutic indications. The average prescription compliance scores were as follows: bevacizumab, 83% for metastatic colorectal cancer, 100% for metastatic breast cancer, and 82.3% for non-small-cell lung cancer; cetuximab, 62.0% for colorectal cancer and 50% for head and neck cancer; trastuzumab, 95.1% for early breast cancer and 82.4% for metastatic breast cancer; and bortezomib, 63.7% for multiple myeloma. CONCLUSION The degree of compliance with criteria for use of cancer drugs was reasonably high. PTC functions need to be changed so that they can carry out more innovative tasks, such as monitoring conditions for drug use.
Resumo:
Laboratory safety data are routinely collected in clinical studies for safety monitoring and assessment. We have developed a truncated robust multivariate outlier detection method for identifying subjects with clinically relevant abnormal laboratory measurements. The proposed method can be applied to historical clinical data to establish a multivariate decision boundary that can then be used for future clinical trial laboratory safety data monitoring and assessment. Simulations demonstrate that the proposed method has the ability to detect relevant outliers while automatically excluding irrelevant outliers. Two examples from actual clinical studies are used to illustrate the use of this method for identifying clinically relevant outliers.
Resumo:
BACKGROUND: The efficacy of angiotensin-converting enzyme (ACE) inhibitors in decreasing blood pressure in African patients is controversial. OBJECTIVE: We examined the ambulatory blood pressure (ABP) response to a diuretic and an ACE inhibitor in hypertensive patients of East African descent and evaluated the individual characteristics that determined treatment efficacy. DESIGN: A single-blind randomized AB/BA crossover design. SETTING: Hypertensive families of East African descent from the general population in the Seychelles. PARTICIPANTS: Fifty-two (29 men and 23 women) out of 62 eligible hypertensive patients were included.Main outcome measures ABP response to 20 mg lisinopril (LIS) daily and 25 mg hydrochlorothiazide (HCT) daily given for a 4-week period.Results The daytime systolic/diastolic ABP response to HCT was 4.9 [95% confidence interval (CI) 1.2-8.6]/3.6 (1.0-6.2) mmHg for men and 12.9 (9.2-16.6)/6.3 (3.7-8.8) mmHg for women. With LIS the response was 18.8 (15.0-22.5)/14.6 (12.0-17.1) mmHg for men and 12.4 (8.7-16.2)/7.7 (5.1-10.2) mmHg for women. The night-time systolic/diastolic response to HCT was 5.0 (0.6-9.4)/2.7 [(-0.4)-5.7] mmHg for men and 11.5 (7.1-16.0)/5.7 (2.6-8.8) mmHg for women, and to LIS was 18.7 (14.2-22.1)/15.4 (12.4-18.5) mmHg for men and 3.5 [(-1.0)-7.9]/2.3 [(-0.8)-5.4] mmHg for women. Linear regression analyses showed that gender is an independent predictor of the ABP responses to HCT and to LIS. CONCLUSIONS: Hypertensive patients of African descent responded better to LIS than to HCT. Men responded better to LIS than to HCT and women responded similarly to both drugs.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
The work presented in this paper belongs to the power quality knowledge area and deals with the voltage sags in power transmission and distribution systems. Propagating throughout the power network, voltage sags can cause plenty of problems for domestic and industrial loads that can financially cost a lot. To impose penalties to responsible party and to improve monitoring and mitigation strategies, sags must be located in the power network. With such a worthwhile objective, this paper comes up with a new method for associating a sag waveform with its origin in transmission and distribution networks. It solves this problem through developing hybrid methods which hire multiway principal component analysis (MPCA) as a dimension reduction tool. MPCA reexpresses sag waveforms in a new subspace just in a few scores. We train some well-known classifiers with these scores and exploit them for classification of future sags. The capabilities of the proposed method for dimension reduction and classification are examined using the real data gathered from three substations in Catalonia, Spain. The obtained classification rates certify the goodness and powerfulness of the developed hybrid methods as brand-new tools for sag classification
Resumo:
This study aimed to evaluate well-documented diagnostic antigens, named B13, 1F8 and JL7 recombinant proteins, as potential markers of seroconversion in treated chagasic patients. Prospective study, involving 203 patients treated with benznidazole, was conducted from endemic areas of northern Argentina. Follow-up was possible in 107 out of them and blood samples were taken for serology and PCR assays before and 2, 3, 6, 12, 24 and 36 months after treatment initiation. Reactivity against Trypanosoma cruzi lysate and recombinant antigens was measured by ELISA. The rate of decrease of antibody titers showed nonlinear kinetics with an abrupt drop within the first three months after initiation of treatment for all studied antigens, followed by a plateau displaying a low decay until the end of follow-up. At this point, anti-B13, anti-1F8 and anti-JL7 titers were relatively close to the cut-off line, while anti-T. cruzi antibodies still remained positive. At baseline, 60.8% (45/74) of analysed patients tested positive for parasite DNA by PCR and during the follow-up period in 34 out of 45 positive samples (75.5%) could not be detected T. cruzi DNA. Our results suggest that these antigens might be useful as early markers for monitoring antiparasitic treatment in chronic Chagas disease.
Resumo:
First discussion on compositional data analysis is attributable to Karl Pearson, in 1897. However, notwithstanding the recent developments on algebraic structure of the simplex, more than twenty years after Aitchison’s idea of log-transformations of closed data, scientific literature is again full of statistical treatments of this type of data by using traditional methodologies. This is particularly true in environmental geochemistry where besides the problem of the closure, the spatial structure (dependence) of the data have to be considered. In this work we propose the use of log-contrast values, obtained by asimplicial principal component analysis, as LQGLFDWRUV of given environmental conditions. The investigation of the log-constrast frequency distributions allows pointing out the statistical laws able togenerate the values and to govern their variability. The changes, if compared, for example, with the mean values of the random variables assumed as models, or other reference parameters, allow definingmonitors to be used to assess the extent of possible environmental contamination. Case study on running and ground waters from Chiavenna Valley (Northern Italy) by using Na+, K+, Ca2+, Mg2+, HCO3-, SO4 2- and Cl- concentrations will be illustrated
Resumo:
Petroleum hydrocarbons are common contaminants in marine and freshwater aquatic habitats, often occurring as a result of oil spillage. Rapid and reliable on-site tools for measuring the bioavailable hydrocarbon fractions, i.e., those that are most likely to cause toxic effects or are available for biodegradation, would assist in assessing potential ecological damage and following the progress of cleanup operations. Here we examined the suitability of a set of different rapid bioassays (2-3 h) using bacteria expressing the LuxAB luciferase to measure the presence of short-chain linear alkanes, monoaromatic and polyaromatic compounds, biphenyls, and DNA-damaging agents in seawater after a laboratory-scale oil spill. Five independent spills of 20 mL of NSO-1 crude oil with 2 L of seawater (North Sea or Mediterranean Sea) were carried out in 5 L glass flasks for periods of up to 10 days. Bioassays readily detected ephemeral concentrations of short-chain alkanes and BTEX (i.e., benzene, toluene, ethylbenzene, and xylenes) in the seawater within minutes to hours after the spill, increasing to a maximum of up to 80 muM within 6-24 h, after which they decreased to low or undetectable levels. The strong decrease in short-chain alkanes and BTEX may have been due to their volatilization or biodegradation, which was supported by changes in the microbial community composition. Two- and three-ring PAHs appeared in the seawater phase after 24 h with a concentration up to 1 muM naphthalene equivalents and remained above 0.5 muM for the duration of the experiment. DNA-damage-sensitive bioreporters did not produce any signal with the oil-spilled aqueous-phase samples, whereas bioassays for (hydroxy)biphenyls showed occasional responses. Chemical analysis for alkanes and PAHs in contaminated seawater samples supported the bioassay data, but did not show the typical ephemeral peaks observed with the bioassays. We conclude that bacterium-based bioassays can be a suitable alternative for rapid on-site quantitative measurement of hydrocarbons in seawater.