922 resultados para National media monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This introductory article argues that the current state of debate on television within cultural studies is marked by considerable areas of theoretical and political uncertainty. The spread of deregulatory and privatizing public policies in relation to television, and the disarticulation of television from the idea of the national community and from the role of the citizen, have posed new problems for theorizing the relation between television and its audiences. In this article I survey a number of key areas of debate: the relation between television, the nation and the state; television and the citizen/consumer, television content and performance, and the likely future(s) of television.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The monitoring of infection control indicators including hospital-acquired infections is an established part of quality maintenance programmes in many health-care facilities. However, surveillance data use can be frustrated by the infrequent nature of many infections. Traditional methods of analysis often provide delayed identification of increasing infection occurrence, placing patients at preventable risk. The application of Shewhart, Cumulative Sum (CUSUM) and Exponentially Weighted Moving Average (EWMA) statistical process control charts to the monitoring of indicator infections allows continuous real-time assessment. The Shewhart chart will detect large changes, while CUSUM and EWMA methods are more suited to recognition of small to moderate sustained change. When used together, Shewhart and EWMA methods are ideal for monitoring bacteraemia and multiresistant organism rates. Shewhart and CUSUM charts are suitable for surgical infection surveillance.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The management of neurotrauma in Australia has been one of the significant public health triumphs during the last 30 years of the 20th century. State and national government agencies act in a coordinated fashion to collect data and to promote research on how to manage neurotrauma patients. Between 1970 and 1995, fatalities from road accidents decreased by 47%. Hospital admissions have decreased by 40% despite a 40% increase in the population and a 120% increase in registered vehicles. Fatalities per 10,000 registered vehicles were 8.05% in 1970 and they fell to 1.84% per vehicles in 1995, while fatalities per 10;000 population were 3 in 1970 falling to 1.11 in 1995. Hospitalization from road crashes decreased 23% between March 1988 and March 1997. Public education has steadily improved, backed by the state public health sources. A uniform code of road safety laws has been adopted, backed by legislation and legal penalties and increasing police enforcement. Clinical care of patients has improved as a result of faster communications, tele-medicine, trauma systems, the CT scanner; intensive care units, and improved monitoring. Patient rehabilitation and counseling are now carried out at units accredited by the Australian Council on Health Care Standards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Because subcutaneous and splanchnic oxygenation indices are sensitive indicators of evolving hemorrhagic shock and adequacy of resuscitation, we postulated that these indices might have an equivalent role in the monitoring of severely burned patients. This observational study was undertaken to examine changes in tissue oxygenation indices during burn resuscitation. METHODS: Seven patients with major burns (54 +/- 21% total body surface area) were studied during the first 36 hours of fluid resuscitation. Silastic tubing was placed in the subcutaneous tissue just beneath both normal skin and deep partial thickness burn. Fiberoptic sensors inserted into the tubing measured subcutaneous oxygen and carbon dioxide tensions in the burnt skin (PO2scb and PCO2scb) and normal skin (PO2scn and PCO2scn) continuously. Gastric intramucosal pH (pHi) and the mucosal CO2 (PCO2m) gap were calculated using gastric tonometers. Mean arterial pressure, arterial pH, lactate, and pHi measurements were obtained for 36 hours. RESULTS: There were no significant differences in mean arterial pressure, arterial pH, or lactate concentrations throughout the study period, whereas indices of tissue oxygenation showed deterioration: pHi decreased from 7.2 +/- 0.1 to 6.7 +/- 0.3 (p = 0.06), the PCO2m gap increased from 12 +/- 17 to 108 +/- 123 mm Hg (p < 0.01), PO2scn decreased from 112 +/- 18 to 50 +/- 11 mm Hg (p < 0.01), PO2scb decreased from 62 +/- 23 to 29 +/- 16 mm Hg (p < 0.01), PCO2scn increased from 42 +/- 4 to 46 +/- 10 mm Hg (p = 0.2), and PCO2scb increased from 42 +/- 10 to 52 +/- 5 mm Hg (p = 0.05). CONCLUSION: Despite adequate global indices of tissue perfusion after 36 hours of resuscitation, tissue monitoring indicated significant deterioration in the splanchnic circulation and in the normal and burnt skin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To test the effect of liquid feeds on the responses to splanchnic ischaemia of a continuous rapid response PCO2 sensor inserted in the jejunum. Design: Prospective experimental animal study in a university research laboratory. Subjects: Adult male Wistar rats. Interventions: Adult male Wistar rats (285-425 g) were anaethetised with sodium pentobarbitone 60 mg/ kg i.p. and ventilated with 100 % oxygen and isoflurane via tracheostomy to a PaCO2 of 30-40 mmHg. A sensor was inserted into the mid-jejunum to record PCO2 every second. Distal aortic pressure was transduced. Four control rats received no feeds whilst in another four rats liquid feed was infused into the proximal jejunum at 3 ml/h. In each rat five episodes of splanchnic ischaemia were induced by 2-min elevations of an aortic sling to a mean distal aortic pressure of 30 mmHg. Measurements and main results: PCO2 elevations were always detectable, usually less than a minute from the onset of splanchnic ischaemia in both fed and unfed rats, with no difference in mean times to detectable response. In the fed rats there was a small but significant increase in the time to peak sensor response (196 +/- 16 vs. 180 +/- 12 s) and a trend towards an elevated mean baseline luminal PCO2 (67 +/- 9 vs. 55 +/- 4 mmHg). Conclusions: Brief episodes of splanchnic ischaemia were tracked successfully by a rapid response jejunal continuous PCO2 sensor during the infusion of a proprietary liquid feed preparation despite minor changes in PCO2 response characteristics and a possible elevation in baseline luminal PCO2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of my action research. I was involved in establishing and running a digital library that was founded by the government of South Korea. The process involved understanding the relationship between the national IT infrastructure and the success factors of the digital library. In building, the national IT infrastructure, a digital library system was implemented; it combines all existing digitized university libraries and can provide overseas information, such as foreign journal articles, instantly and freely to every Korean researcher. An empirical survey was made as a part of the action research; the survey determined user satisfaction in the newly established national digital library. After obtaining the survey results, I suggested that the current way of running the nationwide government-owned digital library should be retained. (C) 2002 Elsevier Science B.V. All rights reserved.