1000 resultados para Medida do volume das úlceras
Resumo:
BACKGROUND: Risky single-occasion drinking (RSOD) is a prevalent and potentially harmful alcohol use pattern associated with increased alcohol use disorder (AUD). However, RSOD is commonly associated with a higher level of alcohol intake, and most studies have not controlled for drinking volume (DV). Thus, it is unclear whether the findings provide information about RSOD or DV. This study sought to investigate the independent and combined effects of RSOD and DV on AUD. METHODS: Data were collected in the longitudinal Cohort Study on Substance Use Risk Factors (C-SURF) among 5598 young Swiss male alcohol users in their early twenties. Assessment included DV, RSOD, and AUD at two time points. Generalized linear models for binomial distributions provided evidence regarding associations of DV, RSOD, and their interaction. RESULTS: DV, RSOD, and their interaction were significantly related to the number of AUD criteria. The slope of the interaction was steeper for non/rare RSOD than for frequent RSOD. CONCLUSIONS: RSOD appears to be a harmful pattern of drinking, associated with increased AUD and it moderated the relationship between DV and AUD. This study highlighted the importance of taking drinking patterns into account, for both research and public health planning, since RSO drinkers constitute a vulnerable subgroup for AUD.
Resumo:
Objective To investigate superior mesenteric artery flow measurement by Doppler ultrasonography as a means of characterizing inflammatory activity in Crohn's disease. Materials and Methods Forty patients were examined and divided into two groups – disease activity and remission – according to their Crohn's disease activity index score. Mean superior mesenteric artery flow volume was calculated for each group and correlated with Crohn's disease activity index score. Results The mean superior mesenteric artery flow volume was significantly greater in the patients with active disease (626 ml/min ± 236 × 376 ml/min ± 190; p = 0.001). As a cut off corresponding to 500 ml/min was utilized, the superior mesenteric artery flow volume demonstrated sensitivity of 83% and specificity of 82% for the diagnosis of Crohn's disease activity. Conclusion The present results suggest that patients with active Crohn's disease have increased superior mesenteric artery flow volume as compared with patients in remission. Superior mesenteric artery flow measurement had a good performance in the assessment of disease activity in this study sample.
Resumo:
Objective The present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and /or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results Preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion Although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section.
Resumo:
BACKGROUND: Most peripheral T-cell lymphoma (PTCL) patients have a poor outcome and the identification of prognostic factors at diagnosis is needed. PATIENTS AND METHODS: The prognostic impact of total metabolic tumor volume (TMTV0), measured on baseline [(18)F]2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography, was evaluated in a retrospective study including 108 PTCL patients (27 PTCL not otherwise specified, 43 angioimmunoblastic T-cell lymphomas and 38 anaplastic large-cell lymphomas). All received anthracycline-based chemotherapy. TMTV0 was computed with the 41% maximum standardized uptake value threshold method and an optimal cut-off point for binary outcomes was determined and compared with others prognostic factors. RESULTS: With a median follow-up of 23 months, 2-year progression-free survival (PFS) was 49% and 2-year overall survival (OS) was 67%. High TMTV0 was significantly associated with a worse prognosis. At 2 years, PFS was 26% in patients with a high TMTV0 (>230 cm(3), n = 53) versus 71% for those with a low TMTV0, [P < 0.0001, hazard ratio (HR) = 4], whereas OS was 50% versus 80%, respectively, (P = 0.0005, HR = 3.1). In multivariate analysis, TMTV0 was the only significant independent parameter for both PFS and OS. TMTV0, combined with PIT, discriminated even better than TMTV0 alone, patients with an adverse outcome (TMTV0 >230 cm(3) and PIT >1, n = 33,) from those with good prognosis (TMTV0 ≤230 cm(3) and PIT ≤1, n = 40): 19% versus 73% 2-year PFS (P < 0.0001) and 43% versus 81% 2-year OS, respectively (P = 0.0002). Thirty-one patients (other TMTV0-PIT combinations) had an intermediate outcome, 50% 2-year PFS and 68% 2-year OS. CONCLUSION: TMTV0 appears as an independent predictor of PTCL outcome. Combined with PIT, it could identify different risk categories at diagnosis and warrants further validation as a prognostic marker.
Resumo:
Objetivo:Determinar intervalos de referência para o volume da cisterna magna fetal por meio do método bidimensional (2D) usando o modo multiplanar da ultrassonografia tridimensional.Materiais e Métodos:Estudo de corte transversal com 224 gestantes normais entre a 17ª e 29ª semanas. O volume foi obtido automaticamente pela multiplicação dos três maiores eixos nos planos axial e sagital pela constante 0,52. Regressão polinomial foi realizada para obter correlação entre o volume 2D da cisterna magna e a idade gestacional, sendo os ajustes realizados pelo coeficiente de determinação (R2). Confiabilidade e concordância foram obtidas pelo coeficiente de correlação intraclasse (CCI) e limites de concordância.Resultados:A média do volume da cisterna magna 2D variou de 0,71 ± 0,19 cm3 para 4,18 ± 0,75 cm3 entre a 17ª e 29ª semanas, respectivamente. Observou-se boa correlação do volume da cisterna magna fetal 2D e a idade gestacional (R2 = 0,67). Observou-se excelente confiabilidade e concordância intraobservador com CCI = 0,89 e limites de concordância 95% (-52,0; 51,8), respectivamente. Observou-se baixa confiabilidade e concordância interobservador com CCI = 0,64 e limites de concordância 95% (-110,1; 84,6), respectivamente.Conclusão:Intervalos de referência para o volume 2D da cisterna magna fetal usando o modo multiplanar da ultrassonografia tridimensional foram determinados e apresentaram excelente confiabilidade e concordância intraobservador.
Resumo:
Abstract Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation ( p = 0.037). A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction ( p = 0.045). Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation.
Resumo:
Arterial stiffness assessed by carotid-femoral pulse wave velocity (cfPWV) measurement is now well accepted as an independent predictor of vascular mortality and morbidity. However, the value of cfPWV has been considered to be limited for risk classification in patients with several vascular risk factors. Magnetic resonance (MR) allows measurement of PWV between two points, though to date mainly used to study the aorta. To assess the common carotid artery pulse wave velocity by magnetic resonance, determine their association with classical vascular risk factors and ischemic brain injury burden in patients with suspected ischemic cerebrovascular disease
Resumo:
The data analyzed in this work were generated following the methodology developed by Molina et al.(J. Electroanal. Chem., 1979) for the calibration of a potentiometric system of measurement of hydrogen-ion concentrations resulting from neutralizations, at 25 ºC, of acidic or alkaline solutions at constant ionic strength (0.1 mol.l-1) held with NaClO4. The observed data present a serious deviation in relation to the mathematical model derived from the Nernst equation, for pH values ranging from 3 to 11, where pH=-log[H+]. We show that the minimization of the sum of the absolute values of the residuals gives estimates that are not influenced by outlying values.
Resumo:
This paper describes the construction of an eletrical current source and of a probe to be used in the measurement of eletrical conductivity through a four-point probe method. These pieces of equipments can be obtained at the low price of US$ 50.00 and are adequate for eletrical conductivity measurements in the semiconductor range, that is from 10-1 to 10-6 S cm-1.
Resumo:
A recent publication reported an exciting polygenic effect of schizophrenia (SCZ) risk variants, identified by a large genome-wide association study (GWAS), on total brain and white matter volumes in schizophrenic patients and, even more prominently, in healthy subjects. The aim of the present work was to replicate and then potentially extend these findings. According to the original publication, polygenic risk scores using single nucleotide polymorphism (SNP) information of SCZ GWAS (polygenic SCZ risk scores; PSS) were calculated in 122 healthy subjects, enrolled in a structural magnetic resonance imaging (MRI) study. These scores were computed based on P-values and odds ratios available through the Psychiatric GWAS Consortium. In addition, polygenic white matter scores (PWM) were calculated, using the respective SNP subset in the original publication. None of the polygenic scores, either PSS or PWM, were found to be associated with total brain, white matter or gray matter volume in our replicate sample. Minor differences between the original and the present study that might have contributed to lack of reproducibility (but unlikely explain it fully), are number of subjects, ethnicity, age distribution, array technology, SNP imputation quality and MRI scanner type. In contrast to the original publication, our results do not reveal the slightest signal of association of the described sets of GWAS-identified SCZ risk variants with brain volumes in adults. Caution is indicated in interpreting studies building on polygenic risk scores without replication sample.
Resumo:
The results suggest that the two variables studied are significant and that they may be independently optimized. The material of the sample holder interferes with the incineration process only due to the amount of heat transfered. The sample holder volume aids diffusion of the atmosphere to the honey sample, minimizing the foaming effect. According to the results, for the thermogravimetric analysis of ash content in honey, sample holders of platinum or alumina of 150 µL are indicated.
Resumo:
We present a participant study that compares biological data exploration tasks using volume renderings of laser confocal microscopy data across three environments that vary in level of immersion: a desktop, fishtank, and cave system. For the tasks, data, and visualization approach used in our study, we found that subjects qualitatively preferred and quantitatively performed better in the cave compared with the fishtank and desktop. Subjects performed real-world biological data analysis tasks that emphasized understanding spatial relationships including characterizing the general features in a volume, identifying colocated features, and reporting geometric relationships such as whether clusters of cells were coplanar. After analyzing data in each environment, subjects were asked to choose which environment they wanted to analyze additional data sets in - subjects uniformly selected the cave environment.
Resumo:
This work describes the establishment of the concept of pH and the evolution of its measurement. The origin of the pH definition can be found in the development of the chemistry of aqueous solutions during the XIXth century. The electrolytic dissociation theory by Svante Arrhenius played a central role. After the proposal of the pH scale by Sörensen, many years were necessary for the acceptance of this new parameter among chemists in general. Its importance was first recognized in biochemistry and related areas. Twenty years after, its importance had been recognized in many industrial and laboratorial practices. The previous methods were based on colorimetric and electrometric methods, but both suffered from many problems. Acceptance of pH in Chemistry was only possible after the development of experimental trustable measurements. The invention of the pH meter was the primordial step.
Resumo:
Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method