866 resultados para Medication Error
Resumo:
A quantum circuit implementing 5-qubit quantum-error correction on a linear-nearest-neighbor architecture is described. The canonical decomposition is used to construct fast and simple gates that incorporate the necessary swap operations allowing the circuit to achieve the same depth as the current least depth circuit. Simulations of the circuit's performance when subjected to discrete and continuous errors are presented. The relationship between the error rate of a physical qubit and that of a logical qubit is investigated with emphasis on determining the concatenated error correction threshold.
Resumo:
We describe a scheme for quantum-error correction that employs feedback and weak measurement rather than the standard tools of projective measurement and fast controlled unitary gates. The advantage of this scheme over previous protocols [for example, Ahn Phys. Rev. A 65, 042301 (2001)], is that it requires little side processing while remaining robust to measurement inefficiency, and is therefore considerably more practical. We evaluate the performance of our scheme by simulating the correction of bit flips. We also consider implementation in a solid-state quantum-computation architecture and estimate the maximal error rate that could be corrected with current technology.
Resumo:
We demonstrate a quantum error correction scheme that protects against accidental measurement, using a parity encoding where the logical state of a single qubit is encoded into two physical qubits using a nondeterministic photonic controlled-NOT gate. For the single qubit input states vertical bar 0 >, vertical bar 1 >, vertical bar 0 > +/- vertical bar 1 >, and vertical bar 0 > +/- i vertical bar 1 > our encoder produces the appropriate two-qubit encoded state with an average fidelity of 0.88 +/- 0.03 and the single qubit decoded states have an average fidelity of 0.93 +/- 0.05 with the original state. We are able to decode the two-qubit state (up to a bit flip) by performing a measurement on one of the qubits in the logical basis; we find that the 64 one-qubit decoded states arising from 16 real and imaginary single-qubit superposition inputs have an average fidelity of 0.96 +/- 0.03.
Resumo:
We describe an implementation of quantum error correction that operates continuously in time and requires no active interventions such as measurements or gates. The mechanism for carrying away the entropy introduced by errors is a cooling procedure. We evaluate the effectiveness of the scheme by simulation, and remark on its connections to some recently proposed error prevention procedures.
Resumo:
Background: some patients may have medication-related risk factors only identified by home visits, but the extent to which those risk factors are associated with poor health outcomes remains unclear. Objective: to determine the association between medication-related risk factors and poor patient health outcomes from observations in the patients' homes. Design: cross-sectional study. Setting: patients' homes. Subjects: 204 general practice patients living in their own homes and at risk of medication-related poor health outcomes. Methods: medications and medication-related risk factors were identified in the patients' homes by community pharmacists and general practitioners (GPs). The medication-related risk factors were examined as determinants of patients' self-reported health related quality of life (SF-36) and their medication use, as well as physicians' impression of patient adverse drug events and health status. Results: key medication-related risk factors associated with poor health outcomes included: Lack of any medication administration routine, therapeutic duplication, hoarding, confusion between generic and trade names, multiple prescribers, discontinued medication repeats retained and multiple storage locations. Older age and female gender were associated with some poorer health outcomes. In addition, expired medication and poor adherence were also associated with poor health outcomes, however, not independently. Conclusion: the findings support the theory that polypharmacy and medication-related risk factors as a result of polypharmacy are correlated to poor health outcomes.
Resumo:
Background: Intravenous (IV) fluid administration is an integral component of clinical care. Errors in administration can cause detrimental patient outcomes and increase healthcare costs, although little is known about medication administration errors associated with continuous IV infusions. Objectives: ( 1) To ascertain the prevalence of medication administration errors for continuous IV infusions and identify the variables that caused them. ( 2) To quantify the probability of errors by fitting a logistic regression model to the data. Methods: A prospective study was conducted on three surgical wards at a teaching hospital in Australia. All study participants received continuous infusions of IV fluids. Parenteral nutrition and non-electrolyte containing intermittent drug infusions ( such as antibiotics) were excluded. Medication administration errors and contributing variables were documented using a direct observational approach. Results: Six hundred and eighty seven observations were made, with 124 (18.0%) having at least one medication administration error. The most common error observed was wrong administration rate. The median deviation from the prescribed rate was 247 ml/h (interquartile range 275 to + 33.8 ml/ h). Errors were more likely to occur if an IV infusion control device was not used and as the duration of the infusion increased. Conclusions: Administration errors involving continuous IV infusions occur frequently. They could be reduced by more common use of IV infusion control devices and regular checking of administration rates.
Resumo:
Vector error-correction models (VECMs) have become increasingly important in their application to financial markets. Standard full-order VECM models assume non-zero entries in all their coefficient matrices. However, applications of VECM models to financial market data have revealed that zero entries are often a necessary part of efficient modelling. In such cases, the use of full-order VECM models may lead to incorrect inferences. Specifically, if indirect causality or Granger non-causality exists among the variables, the use of over-parameterised full-order VECM models may weaken the power of statistical inference. In this paper, it is argued that the zero–non-zero (ZNZ) patterned VECM is a more straightforward and effective means of testing for both indirect causality and Granger non-causality. For a ZNZ patterned VECM framework for time series of integrated order two, we provide a new algorithm to select cointegrating and loading vectors that can contain zero entries. Two case studies are used to demonstrate the usefulness of the algorithm in tests of purchasing power parity and a three-variable system involving the stock market.
Resumo:
A framework for developing marketing category management decision support systems (DSS) based upon the Bayesian Vector Autoregressive (BVAR) model is extended. Since the BVAR model is vulnerable to permanent and temporary shifts in purchasing patterns over time, a form that can correct for the shifts and still provide the other advantages of the BVAR is a Bayesian Vector Error-Correction Model (BVECM). We present the mechanics of extending the DSS to move from a BVAR model to the BVECM model for the category management problem. Several additional iterative steps are required in the DSS to allow the decision maker to arrive at the best forecast possible. The revised marketing DSS framework and model fitting procedures are described. Validation is conducted on a sample problem.
Resumo:
Operator quantum error correction is a recently developed theory that provides a generalized and unified framework for active error correction and passive error avoiding schemes. In this Letter, we describe these codes using the stabilizer formalism. This is achieved by adding a gauge group to stabilizer codes that defines an equivalence class between encoded states. Gauge transformations leave the encoded information unchanged; their effect is absorbed by virtual gauge qubits that do not carry useful information. We illustrate the construction by identifying a gauge symmetry in Shor's 9-qubit code that allows us to remove 3 of its 8 stabilizer generators, leading to a simpler decoding procedure and a wider class of logical operations without affecting its essential properties. This opens the path to possible improvements of the error threshold of fault-tolerant quantum computing.
Resumo:
This letter presents an analytical model for evaluating the Bit Error Rate (BER) of a Direct Sequence Code Division Multiple Access (DS-CDMA) system, with M-ary orthogonal modulation and noncoherent detection, employing an array antenna operating in a Nakagami fading environment. An expression of the Signal to Interference plus Noise Ratio (SINR) at the output of the receiver is derived, which allows the BER to be evaluated using a closed form expression. The analytical model is validated by comparing the obtained results with simulation results.
Resumo:
Resting energy expenditure (REE) is lower than predicted in persons taking atypical antipsychotic medication, and weight management is a significant clinical challenge for some of them. However, to date there have been no published guidelines to assist clinicians in choosing appropriate prediction equations to estimate energy expenditure in persons taking atypical antipsychotic medications. The objectives of this study were to measure REE in a group of men taking the atypical antipsychotic clozapine and to determine whether REE can be accurately predicted for this population using previously published regression equations. REE was measured using indirect calorimetry via a ventilated hood on eight men who had completed at least 6 months of treatment with clozapine. Comparisons between measured REE and predicted REE using five different equations were undertaken. The commonly-used Harris-Benedict and Schofield equations systematically overestimated REE. Predictions of REE from other equations were too variable for clinical use. When estimating energy requirements as part of a weight-management program in men who have been taking clozapine for 6 months, predictions of REE from the equations of Harris-Benedict and Schofield should be reduced by 280 kcal/day.