972 resultados para Medical device industry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total). By using the battery-operated stimulator, contractions of the cecum and movement of contents could be induced in 92% of all stimulations. A cecal shortening of about 30% and an average intraluminal pressure increase of 10.0 +/- 6.0 mmHg were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the framework of a retrospective study of the incidence of hip fractures in the canton of Vaud (Switzerland), all cases of hip fracture occurring among the resident population in 1986 and treated in the hospitals of the canton were identified from among five different information sources. Relevant data were then extracted from the medical records. At least two sources of information were used to identify cases in each hospital, among them the statistics of the Swiss Hospital Association (VESKA). These statistics were available for 9 of the 18 hospitals in the canton that participated in the study. The number of cases identified from the VESKA statistics was compared to the total number of cases for each hospital. For the 9 hospitals the number of cases in the VESKA statistics was 407, whereas, after having excluded diagnoses that were actually "status after fracture" and double entries, the total for these hospitals was 392, that is 4% less than the VESKA statistics indicate. It is concluded that the VESKA statistics provide a good approximation of the actual number of cases treated in these hospitals, with a tendency to overestimate this number. In order to use these statistics for calculating incidence figures, however, it is imperative that a greater proportion of all hospitals (50% presently in the canton, 35% nationwide) participate in these statistics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NIAIC Device Bulletins

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chief Medical Officer - Letters and Urgent Communications

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HSS (GEN) 1) 1/95 update. It is intended to replace the guidance previously provided by former HSSBs and Trusts to assist employers and staff in maintaining strict ethical standards in the conduct of HSC business, in this instance, with the pharmaceutical industry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

undefined