956 resultados para MICROWAVE-SPECTRA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of localizing a scatterer, which represents a tumor, in a homogeneous circular domain, which represents a breast, is addressed. A breast imaging method based on microwaves is considered. The microwave imaging involves to several techniques for detecting, localizing and characterizing tumors in breast tissues. In all such methods an electromagnetic inverse scattering problem exists. For the scattering detection method, an algorithm based on a linear procedure solution, inspired by MUltiple SIgnal Classification algorithm (MUSIC) and Time Reversal method (TR), is implemented. The algorithm returns a reconstructed image of the investigation domain in which it is detected the scatterer position. This image is called pseudospectrum. A preliminary performance analysis of the algorithm vying the working frequency is performed: the resolution and the signal-to-noise ratio of the pseudospectra are improved if a multi-frequency approach is considered. The Geometrical Mean-MUSIC algorithm (GM- MUSIC) is proposed as multi-frequency method. The performance of the GMMUSIC is tested in different real life computer simulations. The performed analysis shows that the algorithm detects the scatterer until the electrical parameters of the breast are known. This is an evident limit, since, in a real life situation, the anatomy of the breast is unknown. An improvement in GM-MUSIC is proposed: the Eye-GMMUSIC algorithm. Eye-GMMUSIC algorithm needs no a priori information on the electrical parameters of the breast. It is an optimizing algorithm based on the pattern search algorithm: it searches the breast parameters which minimize the Signal-to-Clutter Mean Ratio (SCMR) in the signal. Finally, the GM-MUSIC and the Eye-GMMUSIC algorithms are tested on a microwave breast cancer detection system consisting of an dipole antenna, a Vector Network Analyzer and a novel breast phantom built at University of Bologna. The reconstruction of the experimental data confirm the GM-MUSIC ability to localize a scatterer in a homogeneous medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis I analyzed the microwave tomography method to recognize breast can- cer. I study how identify the dielectric permittivity, the Helmoltz equation parameter used to model the real physic problem. Through a non linear least squares method I solve a problem of parameters identification; I show the theoric approach and the devel- opment to reach the results. I use the Levenberg-Marquardt algorithm, applied on COMSOL software to multiphysic models; so I do numerical proofs on semplified test problems compared to the specific real problem to solve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present thesis we address the problem of detecting and localizing a small spherical target with characteristic electrical properties inside a volume of cylindrical shape, representing female breast, with MWI. One of the main works of this project is to properly extend the existing linear inversion algorithm from planar slice to volume reconstruction; results obtained, under the same conditions and experimental setup are reported for the two different approaches. Preliminar comparison and performance analysis of the reconstruction algorithms is performed via numerical simulations in a software-created environment: a single dipole antenna is used for illuminating the virtual breast phantom from different positions and, for each position, the corresponding scattered field value is registered. Collected data are then exploited in order to reconstruct the investigation domain, along with the scatterer position, in the form of image called pseudospectrum. During this process the tumor is modeled as a dielectric sphere of small radius and, for electromagnetic scattering purposes, it's treated as a point-like source. To improve the performance of reconstruction technique, we repeat the acquisition for a number of frequencies in a given range: the different pseudospectra, reconstructed from single frequency data, are incoherently combined with MUltiple SIgnal Classification (MUSIC) method which returns an overall enhanced image. We exploit multi-frequency approach to test the performance of 3D linear inversion reconstruction algorithm while varying the source position inside the phantom and the height of antenna plane. Analysis results and reconstructed images are then reported. Finally, we perform 3D reconstruction from experimental data gathered with the acquisition system in the microwave laboratory at DIFA, University of Bologna for a recently developed breast-phantom prototype; obtained pseudospectrum and performance analysis for the real model are reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nella presente tesi è stato sviluppato un sistema di acquisizione automatico finalizzato allo studio del breast microwave imaging. Le misure sono state eseguite in configurazione monostatica, in cui viene acquisito un segnale da diverse posizioni lungo il perimetro dell’area di indagine. A questo scopo, è stato installato un motore ad alta precisione che permette la rotazione del fantoccio e l’esecuzione automatica delle misure da un numero di posizioni fissato. Per automatizzare il processo di acquisizione, è stato inoltre sviluppato appositamente un software in ambiente LabView. Successivamente, è stata eseguita una intensa sessione di misure finalizzate alla caratterizzazione del sistema sviluppato al variare delle condizioni di misura. Abbiamo quindi utilizzato dei fantocci di tumore di diverse dimensioni e permittività elettrica per studiare la sensibilità della strumentazione in condizione di mezzo omogeneo. Dall’analisi delle ricostruzioni multifrequenza effettuate tramite diversi algoritmi di tipo TR-MUSIC sul range di frequenze selezionato, abbiamo notato che il tumore è ricostruito correttamente in tutti gli scenari testati. Inoltre, abbiamo creato un ulteriore fantoccio per simulare la presenza di una disomogeneità nel dominio di imaging. In questo caso, abbiamo studiato le performances del sistema di acquisizione al variare della posizione del tumore, le cui caratteristiche sono state fissate, e della permittività associata al fantoccio. Dall’analisi dei risultati appare che le performances di ricostruzione sono condizionate dalla presenza della disomogeneità, in modo particolare se il tumore è posizionato all’interno di essa. Infine, abbiamo studiato delle performance di due algoritmi di ricostruzione 3D: uno di essi è basato sulla sovrappo- sizione tomografica e sfrutta metodi di interpolazione, l’altro si basa sull’utilizzo di un propagatore 3D per il dipolo Hertziano in approssimazione scalare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To propose the determination of the macromolecular baseline (MMBL) in clinical 1H MR spectra based on T(1) and T(2) differentiation using 2D fitting in FiTAID, a general Fitting Tool for Arrays of Interrelated Datasets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of water suppression for in vivo proton MR spectroscopy diminishes the signal intensities from resonances that undergo magnetization exchange with water, particularly those downfield of water. To investigate these exchangeable resonances, an inversion transfer experiment was performed using the metabolite cycling technique for non-water-suppressed MR spectroscopy from a large brain voxel in 11 healthy volunteers at 3.0 T. The exchange rates of the most prominent peaks downfield of water were found to range from 0.5 to 8.9 s(-1), while the T(1) relaxation times in absence of exchange were found to range from 175 to 525 ms. These findings may help toward the assignments of the downfield resonances and a better understanding of the sources of contrast in chemical exchange saturation transfer imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a new 22 GHz water vapor spectro-radiometer which has been specifically designed for profile measurement campaigns of the middle atmosphere is presented. The instrument is of a compact design and has a simple set up procedure. It can be operated as a standalone instrument as it maintains its own weather station and a calibration scheme that does not rely on other instruments or the use of liquid nitrogen. The optical system of MIAWARA-C combines a choked gaussian horn antenna with a parabolic mirror which reduces the size of the instrument in comparison with currently existing radiometers. For the data acquisition a correlation receiver is used together with a digital cross correlating spectrometer. The complete backend section, including the computer, is located in the same housing as the instrument. The receiver section is temperature stabilized to minimize gain fluctuations. Calibration of the instrument is achieved through a balancing scheme with the sky used as the cold load and the tropospheric properties are determined by performing regular tipping curves. Since MIAWARA-C is used in measurement campaigns it is important to be able to determine the elevation pointing in a simple manner as this is a crucial parameter in the calibration process. Here we present two different methods; scanning the sky and the Sun. Finally, we report on the first spectra and retrieved water vapor profiles acquired during the Lapbiat campaign at the Finnish Meteorological Institute Arctic Research Centre in Sodankylä, Finland. The performance of MIAWARA-C is validated here by comparison of the presented profiles against the equivalent profiles from the Microwave Limb Sounder on the EOS/Aura satellite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laboratory exercises that confront students with decisive ouantum ohenomena nrovide valuable motivation for the kudy of quantum m&hanics. The idea that microscopic matter exists in quantized states can be demonstrated with modern versions of historic experiments: atomic line snectra. blackbodv radiation. and resonance potentials. In this experiment, we present a strikingly simple and visual method for determining the wavelength of spectral lines. This experiment not only shows the inadequacy of classical physics, but also indicates the power of optical measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydroperoxy radical (HO2) plays a critical role in Earth's atmospheric chemistry as a component of many important reactions. The self-reaction of hydroperoxy radicals in the gas phase is strongly affected by the presence of water vapor. In this work, we explore the potential energy surfaces of hydroperoxy radicals hydrogen bonded to one or two water molecules, and predict atmospheric concentrations and vibrational spectra of these complexes. We predict that when the HO2 concentration is on the order of 108molecules·cm-3 at 298 K, that the number of HO2···H2O complexes is on the order of 107molecules·cm-3 and the number of HO2···(H2O)2 complexes is on the order of 106molecules·cm-3. Using the computed abundance of HO2···H2O, we predict that, at 298 K, the bimolecular rate constant for HO2···H2O + HO2 is about 10 times that for HO2 + HO2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study we present the gas-phase vibrational spectrum of vinylacetic acid with a focus on the ν = 1−5 vibrational states of the OH stretching transitions. Cross sections for ν = 1, 2, 4 and 5 of the OH stretching vibrational transitions are derived on the basis of the vapor pressure data obtained for vinylacetic acid. Ab initio calculations are used to assist in the band assignments of the experimental spectra, and to determine the threshold for the decarboxylation of vinylacetic acid. When compared to the theoretical energy barrier to decarboxylation, it is found that the νOH = 4 transition with thermal excitation of low frequency modes or rotational motion and νOH = 5 transitions have sufficient energy for the reaction to proceed following overtone excitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doubly charged ion mass spectra of alkyl-substituted furans and pyrroles were obtained using a double-focusing magnetic mass spectrometer operated at 3.2 kV accelerating voltage. Molecular ions were the dominant species found in doubly charged spectra of lower molecular weight heterocydic compounds, whereas the spectra of the higher weight homologues were typified by abundant fragment ions from extensive decomposition. Measured doubly charged ionization and appearance energies ranged from 22.8 to 47.9 eV. Ionization energies were correlated with values calculated using self-consistent field–molecular orbital techniques. A multichannel diabatic curve-crossing model was developed to investigate the fundamental organic ion reactions responsible for development of doubly charged ion mass spectra. Probabilities for Landau–Zener type transitions between reactant and product curves were determined and used in the collision model to predict charge-transfer cross-sections, which compared favorably with experimental cross-sections obtained using time-of-flight techniques.