935 resultados para MICROVOLTAMMETRIC ELECTRODES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The fabrication and analytical applications of two types of potentiometric sensors for the determination of ketoconazole (KET) are described. The sensors are based on the use of KET-molybdophosphoric acid (MPA) ion pair as electroactive material. The fabricated sensors include both polymer membrane and carbon paste electrodes. Both sensors showed a linear, stable and near Nernstian slope of 57.8mV=decade and 55.2mV=decade for PVC membrane and carbon paste sensors respectively over a relatively wide range of KET concentration (1×10-2-5×10-5 and 1×10-2-1×10-6). The sensors showed a fast response time of <30 sec and <45 sec. A useful pH range of 3–6 was obtained for both types of sensors. A detection limit of 2.96 10 5M was obtained for PVC membrane sensor and 6.91 10 6M was obtained for carbon paste sensor. The proposed sensors proved to have a good selectivity for KET with respect to a large number of ions. The proposed sensors were successfully applied for the determination of KET in pharmaceutical formulations. The results obtained are in good agreement with the values obtained by the standard method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inter-digital capacitive electrodes working as electric field sensors have been developed for touch panel applications. Evaluation circuits to convert variations in electric fields in such sensors into computer compatible data are commercially available. We report development of an Interdigital capacitive electrode working as a sensitive pressure sensor in the range 0-120 kPa. Essentially it is a touch/proximity sensor converted into a pressure sensor with a suitable elastomer buffer medium acting as the pressure transmitter. The performance of the sensor has been evaluated and reported. Such sensors can be made very economical in comparison to existing pressure sensors. Moreover, they are very convenient to be fabricated into sensor arrays involving a number of sensors for distributed pressure sensing applications such as in biomedical systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Photoconductivity (PC) processes may be the most suitable technique for obtaining information about the states in the gap. It finds applications in photovoItaics, photo detection and radiation measurements. The main task in the area of photovoltaics, is to increase the efficiency of the device and also to develop new materials with good optoelectronic properties useful for energy conversion, keeping the idea of cost effectiveness. Photoconduction includes generation and recombination of carriers and their transport to the electrodes. So thermal relaxation process, charge carrier statistics, effects of electrodes and several mechanisms of recombination are involved in photoconductivity.A major effect of trapping is to make the experimentally observed decay time of photocurrent, longer than carrier lifetime. If no trapping centers are present, then observed photocurrent will decay in the same way as the density of free carriers and the observed decay time will be equal to carrier lifetime. If the density of free carriers is much less than density of trapped carriers, the entire decay of photocurrent is effectively dominated by the rate of trap emptying rather than by the rate of recombination.In the present study, the decay time of carriers was measured using photoconductive decay (PCD) technique. For the measurements, the film was loaded in a liquid Helium cryostat and the temperature was controlled using Lakshore Auto tuning temperature controller (Model 321). White light was used to illuminate the required area of the sample. Heat radiation from the light source was avoided by passing the light beam through a water filter. The decay current. after switching off the illumination. was measured using a Kiethely 2000 multi meter. Sets of PCD measurements were taken varying sample temperature, sample preparation temperature, thickness of the film, partial pressure of Oxygen and concentration of a particular element in a compound. Decay times were calculated using the rate window technique, which is a decay sampling technique particularly suited to computerized analysis. For PCD curves with two well-defined regions, two windows were chosen, one at the fast decay region and the other at the slow decay region. The curves in a particular window were exponentially fitted using Microsoft Excel 2000 programme. These decay times were plotted against sample temperature and sample preparation temperature to study the effect of various defects in the film. These studies were done in order to optimize conditions of preparation technique so as to get good photosensitive samples. useful for photovoltaic applications.Materials selected for the study were CdS, In2Se3, CuIn2Se3 and CuInS2• Photoconductivity studies done on these samples are organised in six chapters including introduction and conclusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Voltammetric sensors are an important class of electrochemical sensors in which the analytical information is obtained from the measurement of current obtained as a result of electrochemical oxidation/reduction.This current is proportional to the concentration of the analyte.Chemically modified electrodes(CMEs) have great significance as important analytical tools for the electrochemical determination of pharmaceuticals.The modification of electrode results in efficient determination of electro-active biomolecules at very lower potential without its major interferences.The operation mechanism of CMEs depends on the properties of the modifier materials that are used to promote selectivity towards the target analytes.Modified electrodes can be prepared by deposition of various compounds such as organic compounds ,conducting polymers,metal oxides,etc. on the various electrode surfaces.The thesis presents the development ,electrochemical characterization and analytical application studies of eight voltammetric sensors developed for six drugs viz.,Ambroxol,Sulfamethoxazole,PAM Chloride, Lamivudine,Metronidazole and Nimesulide.The modification techniques adopted as part of the present work include Multiwalled Carbon Nanotube(MWCNT) based modification.Electropolymerisation and Gold Nanoparticle (AuNP) based modifications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The primary aim of these investigations was to probe the elecnuchemical and material science aspects of some selected metal phthalocyanines(MPcs).Metal phthalocyanines are characterised by a unique planar molecular structure. As a single class of compounds they have been the subject of ever increasing number of physicochemical and technological investigations. During the last two decades the literature on these compounds was flooded by an outpour of original publications and patents. Almost every branch of materials science has benefited by their application-swface coating, printing, electrophotography, photoelectrochemistry, electronics and medicine to name a few.The present study was confined to the electrical and electrochemical properties of cobalt, nickel, zinc. iron and copper phthalocyanines. The use of soluble Pes as corrosion inhibitor for aluminium was also investigated.In the introductory section of the thesis, the work done so far on MPcs is reviewed. In this review emphasis is given to their general methods of synthesis and the physicochemical properties.In phthalocyanine chemistry one of the formidable tasks is the isolation of singular species. In the second chapter the methods of synthesis and purification are presented with necessary experimental details.The studies on plasma modified films of CoPe, FePc, ZnPc. NiPc and CuPc are also presented.Modification of electron transfer process by such films for reversible redox systems is taken as the criterion to establish enhanced electrocatalytic activity.Metal phthalocyanines are p- type semiconductors and the conductivity is enhanced by doping with iodine. The effect of doping on the activation energy of the conduction process is evaluated by measuring the temperature dependent variation of conductivity. Effect of thennal treatment on iodine doped CoPc is investigated by DSC,magnetic susceptibility, IR, ESR and electronic spectra. The elecnucatalytic activity of such doped materials was probed by cyclic voltammetry.The electron transfer mediation characteristics of MPc films depend on the film thickness. The influence of reducing the effective thickness of the MPc film by dispersing it into a conductive polymeric matrix was investigated. Tetrasulphonated cobalt phthalocyanine (CoTSP) was electrostatically immobilised into polyaniline and poly(o-toluidine) under varied conditions.The studies on corrosion inhibition of aluminium by CoTSP and CuTSP and By virtue of their anionic character they are soluble in water and are strongly adsorbed on aluminium. Hence they can act as corrosion inhibitors. CoTSP is also known to catalyze the reduction of dioxygen.This reaction can accelerate the anodic dissolution of metal as a complementary reaction. The influence of these conflicting properties of CoTSP on the corrosion of aluminium was studied and compared with those of CuTSP.In the course of these investigations a number of gadgets like cell for measuring the electrical conductivity of solids under non-isothermal conditions, low power rf oscillator and a rotating disc electrode were fabricated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In many fields such as earth science biology, environment and electronics, the knowledge about elemental distributions and chemical speciation is important. The determination of metal levels especially the toxic ones both in the environment and in biological materials are increasingly demanded by the society.Ion selective sensors have become one of the most effective ad powerful means for analytical scientists for the trace level monitoring of metal ions. The wide range of applications ,low material requirements and simplicity of analytical procedure have not only brought ion-selective electrodes in to the lime light of analytical chemistry,but have promoted their use as tools for physiologists,medical researchers,biologists,geologists,environmental protection specialists etc.Potentiometric ion-selective sensors have been developed for the determination of lanthanide ions such as La3+,Nd3+,Pr3+,Sm3+, and Gd3+.The sensors fabricated include both PVC membrane sensor and chemically modified carbon paste sensor. A set of 10 sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied as an indicator electrode in the potentiometric titration and for the determination of metal ions in real samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of electrochemical sensors is currently one of the active areas of research in analytical chemistry.Voltammetric sensors as an important class of electrochemical sensors are extensively used in pharmaceutical applications.In voltammetric analysis,many active compounds in dosage forms,in contrast to excipients,can be readily oxidised or reduced at the electrode surface by applying a potential.Chemically modified electrodes have great significance in the electrochemical determination of pharmaceuticals.The modification of electrode results in efficient determination of electroactive species at very lower potential without any major interferences.The present study involves the fabrication of 8 voltammetric sensors for the drugs Metronidazole Benzoate, Sulfamethoxazole, Acyclovir, Pam Chloride , Trimethoprim , Tamsulosin Hydrochloride and Ceftriaxone Sodium.Two sensors were developed for the drug tamsulosin hydrochloride while one sensor each was developed for the other drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis Entitled INVESTIGATIONS ON THE STRUCTURAL, OPTICAL AND MAGNETIC PROPERTIES OF NANOSTRUCTURED CERIUM OXIDE IN PURE AND DOPED FORMS AND ITS POLYMER NANOCOMPOSITES.Synthesis and processing of nanomatelials and nanostmctures are the essential aspects of nanotechnology. Studies on new physical properties and applications of nanomaterials and nanostructures are possible only when nanostructured materials are made available with desired size, morphology,crystal structure and chemical composition.Recently, several methods have been developed to prepare pure and doped CeO2 powder, including wet chemical synthesis, thermal hydrolysis, flux method, hydrothermal synthesis, gas condensation method, microwave technique etc. In all these, some special reaction conditions, such as high temperature, high pressure, capping agents, expensive or toxic solvents etc. have been involved.Another hi gh-li ght of the present work is room temperature ferromagnetism in cerium oxdie thin films deposited by spray pyrolysis technique.The observation of self trapped exciton mediated PL in ceria nanocrystals is another important outcome of the present study. STE mediated mechanism has been proposed for CeO2 nanocrystals based on the dependence of PL intensity on the annealing temperature. It would be interesting to extent these investigations to the doped forms of cerium oxide and cerium oxide thin films to get deeper Insight into STE mechanism.Due to time constraints detailed investigations could not be canied out on the preparation and properties of free standing films of polymer/ceria nanocomposites. It has been observed that good quality free standing films of PVDF/ceria, PS/C61‘l8, PMMA/ceria can be obtained using solution casting technique. These polymer nanocomposite films show high dielectric constant around 20 and offer prospects of applications as gate electrodes in metal-oxide semiconductor devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electroanalytical techniques represent a class of powerful and versatile analytical method which is based on the electrical properties of a solution of the analyte when it is made part of an electrochemical cell. They offer high sensitivity, accuracy, precision and a large linear dynamic range. The cost of instrumentation is relatively low compared to other instrumental methods of analysis. Many solid state electrochemical sensors have been commercialised nowadays. Potentiometry is a very simple electroanalytical technique with extraordinary analytical capabilities. Since valinomycin was introduced as an ionophore for K+, Ion Selective Electrodes have become one of the best studied and understood analytical devices. It can be used for the determination of substances ranging from simple inorganic ions to complex organic molecules. It is a very attractive option owing to the wide range of applications and ease of the use of the instruments employed. They also possess the advantages of short response time, high selectivity and very low detection limits. Moreover, analysis by these electrodes is non-destructive and adaptable to small sample volumes. It has become a standard technique for medical researchers, biologists, geologists and environmental specialists. This thesis presents the synthesis and characterisation of five ionophores. Based on these ionophores, nine potentiometric sensors are fabricated for the determination of ions such as Pb2+, Mn2+, Ni2+, Cu2+ and Sal- ion (Salicylate ion). The electrochemical characterisation and analytical application studies of the developed sensors are also described. The thesis is divided into eight chapters

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Màster en Nanociència i Nanotecnologia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis consists of a study of the effect of electrode films and overlayer films on the electrical properties of certain metal films. The films have been prepared on glass substrates by thermal evapouration in a vaccum 10 terr. The properties of Al films on Ag, Al,Au and Cu films on In electrodes ,and Bi/Ag bilayer films have been studied. The influence of annealing electrodes at higher temperature on the electrical properties of metal films has also been investigated. Further the effect of varying layer thickness in the bilayer films ,both annealed at higher temperature and annealed at room temperature have been examined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrochemical sensors are increasingly being investigated to perform measurements for single or multiple analytes. Demanded by modern medical diagnosis, advances in microfabrication technology have led to the development of fast, sensitive and selective electrochemical sensors for drug analysis. Electrochemical sensors for the measurement of analytes of interest in clinical chemistry are ideally suited for these applications, due to their high sensitivity and selectivity, simple-to-operate, rapid response time and low-cost. As part of the present investigations eight voltammetric sensors have been fabricated for six drugs such as PAM Chloride, Tamsulosin Hydrochloride, Hesperidin Methyl Chalcone, Guaiphenesin, Cephalexin and Amoxicillin trihydrate. The modification techniques adopted as part of the present work include multiwalled carbon nanotube (MWNT) based modifications, electropolymerization, gold nanoparticle (AuNP) based modifications and platinum nanoparticle (PtNP) based modifications. The thesis is divided into nine chapters

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Màster en Nanociència i Nanotecnologia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Voltammetric methods are applicable for the determination of a wide variety of both organic and inorganic species. Its features are compact equipment, simple sample preparation, short analysis time, high accuracy and sensitivity. Voltammetry is especially suitable for laboratories in which only a few parameters have to be monitored with a moderate sample throughput. Of various electrode materials, glassy carbon electrode is particularly useful because of its high electrical conductivity, impermeability to gases, high chemical resistance, reasonable mechanical and dimensional stability and widest potential range of all carbonaceous electrodes. Electrode modification is a vigorous research area by which the electrochemical determination of various analyte species is facilitated. The scope of pharmaceutical analysis includes the analytical investigation of pure drug, drug formulations, impurities and degradation products of drugs, biological samples containing the drugs and their metabolites with the aim of obtaining data that can contribute to the maximal efficacy and maximal safety of drug therapy. This thesis presents the modification of glassy carbon electrode using metalloporphyrin and dyes and subsequently using these modified electrodes for the determination of various pharmaceuticals. The thesis consists of 9 chapters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Welding of high strength and low weight materials like Aluminium Alloys without any defects by conventional welding techniques is a major challenge in industries. Hence research on solid state welding techniques like Friction stir welding and Friction welding techniques have got much importance in joining of Aluminium alloys. However most of the industries are not changing conventional techniques as skilled workers are available on that area. Most common conventional welding techniques used for joining of Aluminium alloys are Gas welding and Arc welding. Friction welding is a solid-state welding process that generates heat through mechanical friction between a moving and a stationary component with the addition of a lateral force called “upset” to plast ically displace and fuse the materials. In this work, experimental study on tensile and micro structural characteristics of welded joints formed from conventional welding techniques and Rotary friction welding(suitable for weld specimens with circular cross section) has been carried out and the same were compared. The process parameters for arc welding used was 50-70 Amp reverse polarity DC and electrodes of 2.3mm diameter. In Gas welding, the parameters were oxy acetylene neural flame at 3200°C and 3mm electrodes . In the case of friction welding an axial pressure loading of 3Mpa with 5 MPa as upsetting pressure and 500 rpm were used to obtain good welded joints. Tensile characteristic studies of Arc welded joints and Gas welded joints showed 48% and 60 % variations respectively from the maximum load bearing characteristics of parent metal. In the case of friction welded joint, the variation was found to 46%. Micro structural evaluation of conventionally welded joints exhibited clear distinct zones of various weld regions. In the case of friction welded joint micro structural photographs showed comparable features both in parent metal and welded region. Thus the tensile characteristic study and microstructure evaluations proved that friction welded joints are good in both aspects compared to conventionally welded joints.