876 resultados para Load voltage maximization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new family of direct current (DC) to DC converters based on a zero current switching pulse width modulated (ZCS-PWM) soft commutation cell is presented. This ZCS-PWM cell is consists of two transistors, two diodes, two inductors and one capacitor; and provides zero voltage turn-on to the diodes, a zero-current turn-on and a zero-current zero-voltage turn-off to the transistors. In addition, a new commutation cell in a new ZCS-PWM boost rectifier is developed, obtaining a structure with power factor near the unity, high efficiency at wide load range and low total harmonic distortion in the input current.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes the use of a simple voltage divider circuit composed by one potentiometer and one resistor to simulate the behavior of the electrical output signal of linear and nonlinear sensors. It is a low cost way to implement practical experiments in classroom and it also enables the analysis of interesting topics of electricity. This work induces naturally to a class guide where students can build and characterize a voltage divider to explore several concepts about sensors output signal. As the result of this teaching activity it is expected that students understand fundamentals of voltage divider, potentiometer operation, fundamental sensor characteristics, transfer function, and, besides, associate directly concepts of physics and mathematics with a practical approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tests used to obtain the stiffness properties of wood are made with two loading cycles, as defined by the Brazilian standard ABNT NBR 7190 (Design of Timber Structures). However, the possibility of reducing the number of cycles allows decrease the operating time of the machine, resulting in reduced spending on electricity used during the tests. This research aimed to investigate, with the aid of the analysis of variance (ANOVA), the influence of the use of three load cycles to obtain the modulus of elasticity in compression parallel to grain (Ec0), in tensile parallel to the grain (Et0), in bending (Em) and in compression perpendicular to the grain (Ec90) of Angico Preto (Anadenanthera macrocarpa) wood specie. For the number of cycles and stiffness were manufactured 12 samples, totaling 144 specimens. The results of the ANOVA revealed statistical equivalence between the stiffness properties for both load cycle numbers evaluated, indicating that it is possible to carry out the tests with a single charge cycle, allowing savings in time and energy in the operation of the equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cage aquaculture in hydroelectric reservoirs has great potential for expansion in Brazil, but there are concerns of negative environmental impacts. The environmental sustainability of cage culture depends on hamornization between farming practices and the hydrological peculiarities of the site. Mass balance modeling can estimate the amounts of nutrients that can be loaded without triggering eutrophication and resulting maximum allowable production volume. Careful climate zoning can also assist proper siting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The next-generation SONET metro network is evolving into a service-rich infrastructure. At the edge of such a network, multi-service provisioning platforms (MSPPs) provide efficient data mapping enabled by Generic Framing Procedure (GFP) and Virtual Concatenation (VC). The core of the network tends to be a meshed architecture equipped with Multi-Service Switches (MSSs). In the context of these emerging technologies, we propose a load-balancing spare capacity reallocation approach to improve network utilization in the next-generation SONET metro networks. Using our approach, carriers can postpone network upgrades, resulting in increased revenue with reduced capital expenditures (CAPEX). For the first time, we consider the spare capacity reallocation problem from a capacity upgrade and network planning perspective. Our approach can operate in the context of shared-path protection (with backup multiplexing) because it reallocates spare capacity without disrupting working services. Unlike previous spare capacity reallocation approaches which aim at minimizing total spare capacity, our load-balancing approach minimizes the network load vector (NLV), which is a novel metric that reflects the network load distribution. Because NLV takes into consideration both uniform and non-uniform link capacity distribution, our approach can benefit both uniform and non-uniform networks. We develop a greedy loadbalancing spare capacity reallocation (GLB-SCR) heuristic algorithm to implement this approach. Our experimental results show that GLB-SCR outperforms a previously proposed algorithm (SSR) in terms of established connection capacity and total network capacity in both uniform and non-uniform networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wavelength-routed networks (WRN) are very promising candidates for next-generation Internet and telecommunication backbones. In such a network, optical-layer protection is of paramount importance due to the risk of losing large amounts of data under a failure. To protect the network against this risk, service providers usually provide a pair of risk-independent working and protection paths for each optical connection. However, the investment made for the optical-layer protection increases network cost. To reduce the capital expenditure, service providers need to efficiently utilize their network resources. Among all the existing approaches, shared-path protection has proven to be practical and cost-efficient [1]. In shared-path protection, several protection paths can share a wavelength on a fiber link if their working paths are risk-independent. In real-world networks, provisioning is usually implemented without the knowledge of future network resource utilization status. As the network changes with the addition and deletion of connections, the network utilization will become sub-optimal. Reconfiguration, which is referred to as the method of re-provisioning the existing connections, is an attractive solution to fill in the gap between the current network utilization and its optimal value [2]. In this paper, we propose a new shared-protection-path reconfiguration approach. Unlike some of previous reconfiguration approaches that alter the working paths, our approach only changes protection paths, and hence does not interfere with the ongoing services on the working paths, and is therefore risk-free. Previous studies have verified the benefits arising from the reconfiguration of existing connections [2] [3] [4]. Most of them are aimed at minimizing the total used wavelength-links or ports. However, this objective does not directly relate to cost saving because minimizing the total network resource consumption does not necessarily maximize the capability of accommodating future connections. As a result, service providers may still need to pay for early network upgrades. Alternatively, our proposed shared-protection-path reconfiguration approach is based on a load-balancing objective, which minimizes the network load distribution vector (LDV, see Section 2). This new objective is designed to postpone network upgrades, thus bringing extra cost savings to service providers. In other words, by using the new objective, service providers can establish as many connections as possible before network upgrades, resulting in increased revenue. We develop a heuristic load-balancing (LB) reconfiguration approach based on this new objective and compare its performance with an approach previously introduced in [2] and [4], whose objective is minimizing the total network resource consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Starting induction motors on isolated or weak systems is a highly dynamic process that can cause motor and load damage as well as electrical network fluctuations. Mechanical damage is associated with the high starting current drawn by a ramping induction motor. In order to compensate the load increase, the voltage of the electrical system decreases. Different starting methods can be applied to the electrical system to reduce these and other starting method issues. The purpose of this thesis is to build accurate and usable simulation models that can aid the designer in making the choice of an appropriate motor starting method. The specific case addressed is the situation where a diesel-generator set is used as the electrical supplied source to the induction motor. The most commonly used starting methods equivalent models are simulated and compared to each other. The main contributions of this thesis is that motor dynamic impedance is continuously calculated and fed back to the generator model to simulate the coupling of the electrical system. The comparative analysis given by the simulations has shown reasonably similar characteristics to other comparative studies. The diesel-generator and induction motor simulations have shown good results, and can adequately demonstrate the dynamics for testing and comparing the starting methods. Further work is suggested to refine the equivalent impedance presented in this thesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By performing density functional theory calculations we show that it is possible to make the electronic bandgap in bilayer graphene supported on hexagonal boron nitride (h-BN) substrates tunable. We also show that, under applied electric fields, it is possible to insert states from h-BN into the bandgap, which generate a conduction channel through the substrate making the system metallic. In addition, we verify that the breakdown voltage strongly depends on the number of h-BN layers. We also show that both the breakdown voltage and the bandgap tuning are independent of the h-BN stacking order.