903 resultados para Images AVIRIS
Resumo:
The purpose of this study was to evaluate the radiopacity of 5 root-end filling materials (white MTA-Angelus, grey MTA-Angelus, IRM, Super EBA and Sealer 26). Five specimens (10 mm diameter X 1 mm thickness) were made from each material and radiographed next to an aluminum stepwedge varying in thickness from 2 to 16 mm. Radiographs were digitized and the radiopacity of the materials was compared to that of the aluminum stepwedge using VIXWIN 2000 software in millimeters of aluminum ( mm Al). Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. Radiopacity values varied from 3 mm Al to 5.9 mm Al. Sealer 26 and IRM presented the highest radiopacity values (p<0.05), while white/grey MTA and Super EBA presented the lowest radiopacity values (p<0.05). The tested root- end filling materials presented different radiopacities, white/grey MTA and Super EBA being the least radiopaque materials.
Resumo:
New formularizations, techniques and devices have become the dental whitening most safe and with better results. Although this, the verification of the levels whitening is being continued for visual comparison, that is an empirical, subjective method, subject to errors and dependent of the individual interpretation. Normally the result of the whitening is express for the amplitude of displacement between the initial and the final color, being take like reference the tonalities of a scale of color commanded of darkest for more clearly. Although to be the most used scale, the ordinance of the Vita Classical (R) - Vita, according to recommendations of the manufacturer, reveals inadequate for the evaluation of the whitening. From digital images and of algorithm OER (ordinance of the reference scale), especially developed for the ScanWhite (C), the ordinance of the tonalities of the scale Vita Classical (R) was made. For such, the values of the canals of color R, G, and B of medium part average of the crowns was adopted as reference for evaluation. The images had been taken with the camera Sony Cybershoot DSC F828. The results of the computational ordinance had been compared with the sequence proposal for the manufacturer and with the earned one for the visual evaluation, carried through by 10 volunteers, under standardized conditions of illumination. It statistics analyzes demonstrated significant differences between the ordinances.
Resumo:
This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its applications to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study. In this paper, these images were used to confirm the existence of vortex structures in the flow induced by corona discharges on airfoil models. These structures are a possible explanation for the effects of drag reduction and lift force increasing, which have been reported in experiments of plasma assisted Aerodynamics.
Resumo:
This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its application to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study.
Resumo:
Computer systems are used to support breast cancer diagnosis, with decisions taken from measurements carried out in regions of interest (ROIs). We show that support decisions obtained from square or rectangular ROIs can to include background regions with different behavior of healthy or diseased tissues. In this study, the background regions were identified as Partial Pixels (PP), obtained with a multilevel method of segmentation based on maximum entropy. The behaviors of healthy, diseased and partial tissues were quantified by fractal dimension and multiscale lacunarity, calculated through signatures of textures. The separability of groups was achieved using a polynomial classifier. The polynomials have powerful approximation properties as classifiers to treat characteristics linearly separable or not. This proposed method allowed quantifying the ROIs investigated and demonstrated that different behaviors are obtained, with distinctions of 90% for images obtained in the Cranio-caudal (CC) and Mediolateral Oblique (MLO) views.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction: The aim of this study was to evaluate craniofacial asymmetry by using 2-dimensional (2D) poster-oanterior cephalometric images, 3-dimensional cone-beam computed tomography (CBCT), and physical measurements (gold standard). Methods: Ten dry human skulls were assessed, and radiopaque markers were placed on 17 skeletal landmarks. Twenty linear measurements were taken on each side to compare the right and left sides and to compare these measurements with the physical measurements made with a digital caliper. To acquire the 2D posteroanterior radiographs, an Extraoral Phosphor Storage Plate (Air Techniques, Chicago, Ill) was used as the image receptor with a Eureka x-ray-Duocon Machlett unit (Machlett Laboratores, Chicago, Ill). Three-dimensional imaging data were acquired from a CB MercuRay (Hitachi Medical, Tokyo, Japan). Results: on average, the right side was larger than the left for most of the 20 distances evaluated in the digital 2D and the CBCT images, and there was poor agreement between the digital 2D images and the physical measurements (kappa = 0.0609) and almost perfect agreement (kappa = 0.92) between the CBCT and physical measurements when individual measurements were considered. Conclusions: Human skulls, with no apparent asymmetry, had some differences between the right and left sides, with dominance for the right side but with no clinical significance. CBCT can better evaluate craniofacial morphology when compared with digital 2D images. (Am J Orthod Dentofacial Orthop 2011; 139: e523-e531)
Resumo:
Let f: M --> N and g: K --> N be generic differentiable maps of compact manifolds without boundary into a manifold such that their intersection satisfies a certain transversality condition. We show, under a certain cohomological condition, that if the images f(M) and g(K) intersect, then the (upsilon + 1)th Betti number of their union is strictly greater than the sum of their (upsilon + 1)th Betti numbers, where upsilon = dim M + dim K - dim N. This result is applied to the study of coincidence sets and fixed point sets. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A computer program, PhotoLin, written for an IBM-PC-compatible microcomputer is described which detects linear features in aerial photographs, satellite images and topographic maps. The program accepts images saved to PCX files as input and applies noise correction and smoothing filters and thinning routines. The output consists of a skeleton containing the median lines of linear features which can be represented on a map. The branches of the skeleton can be broken into sections of constant length for which the mean orientations are obtained for the preparation of rose diagrams. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
The identification of ground control on photographs or images is usually carried out by a human operator, who uses his natural skills to make interpretations. In Digital Photogrammetry, which uses techniques of digital image processing extraction of ground control can be automated by using an approach based on relational matching and a heuristic that uses the analytical relation between straight features of object space and its homologous in the image space. A build-in self-diagnosis is also used in this method. It is based on implementation of data snooping statistic test in the process of spatial resection using the Iterated Extended Kalman Filtering (IEKF). The aim of this paper is to present the basic principles of the proposed approach and results based on real data.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)