907 resultados para High-low spread estimator
Resumo:
Response to treatment with antimonial drugs varies considerably depending on the parasite strain involved, immune status of the patient and clinical form of the disease. Therapeutic regimens with this first line drug have been frequently modified both, in dose and duration of therapy. A regimen of 20 mg/kg/day of pentavalent antimony (Sb5+) during four weeks without an upper limit on the daily dose is currently recommended for mucosal disease ("espundia"). Side-effects with this dose are more marked in elderly patients, more commonly affected by this form of leishmaniasis. According to our experience, leishmaniasis in Rio de Janeiro responds well to antimony and, in cutaneous disease, high cure rates are obtained with 5 mg/kg/day of Sb5+ during 30 to 45-days. In this study a high rate of cure (91.4%) employing this dose was achieved in 36 patients with mild disease in this same geographic region. Side-effects were reduced and no antimony refractoriness was noted with subsequent use of larger dose in patients that failed to respond to initial schedule.
Resumo:
Radio link quality estimation is essential for protocols and mechanisms such as routing, mobility management and localization, particularly for low-power wireless networks such as wireless sensor networks. Commodity Link Quality Estimators (LQEs), e.g. PRR, RNP, ETX, four-bit and RSSI, can only provide a partial characterization of links as they ignore several link properties such as channel quality and stability. In this paper, we propose F-LQE (Fuzzy Link Quality Estimator, a holistic metric that estimates link quality on the basis of four link quality properties—packet delivery, asymmetry, stability, and channel quality—that are expressed and combined using Fuzzy Logic. We demonstrate through an extensive experimental analysis that F-LQE is more reliable than existing estimators (e.g., PRR, WMEWMA, ETX, RNP, and four-bit) as it provides a finer grain link classification. It is also more stable as it has lower coefficient of variation of link estimates. Importantly, we evaluate the impact of F-LQE on the performance of tree routing, specifically the CTP (Collection Tree Protocol). For this purpose, we adapted F-LQE to build a new routing metric for CTP, which we dubbed as F-LQE/RM. Extensive experimental results obtained with state-of-the-art widely used test-beds show that F-LQE/RM improves significantly CTP routing performance over four-bit (the default LQE of CTP) and ETX (another popular LQE). F-LQE/RM improves the end-to-end packet delivery by up to 16%, reduces the number of packet retransmissions by up to 32%, reduces the Hop count by up to 4%, and improves the topology stability by up to 47%.
Resumo:
Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.
Resumo:
Anti-Toxoplasma IgG-avidity was determined in 168 serum samples from IgG- and IgM-positive pregnant women at various times during pregnancy, in order to evaluate the predictive value for risk of mother-to-child transmission in a single sample, taking the limitations of conventional serology into account. The neonatal IgM was considered the serologic marker of transmission. Fluorometric tests for IgG, IgM (immunocapture) and IgG-avidity were performed. Fifty-one of the 128 pregnant women tested gave birth in the hospital and neonatal IgM was obtained. The results showed 32 (62.75%) pregnant women having high avidity, IgM indexes between 0.6 and 2.4, and no infected newborn. Nineteen (37.25%) had low or inconclusive avidity, IgM indexes between 0.6 and 11.9, and five infected newborns and one stillbirth. In two infected newborns and the stillbirth maternal IgM indexes were low and in one infected newborn the only maternal parameter that suggested fetal risk was IgG-avidity. In the present study, IgG-avidity performed in single samples from positive IgM pregnant women helped to determine the risk of transmission at any time during pregnancy, especially when the indexes of the two tests were analysed with respect to gestational age. This model may be less expensive in developing countries where there is a high prevalence of infection than the follow-up of susceptible mothers until childbirth with monthly serology, and it creates a new perspective for the diagnosis of congenital toxoplasmosis.
Resumo:
The aim of this study was to describe epidemiologic characteristics of intestinal parasites in a population in south of Tehran, Iran. A retrospective cross-sectional study of patients with suspicious intestinal parasitic infections referred to the Zakaria Razi Laboratory in Shahre-Ray, southern Tehran, Iran, was conducted from April 21, 2004 to October 20, 2005. All stool samples were examined and socio-demographic informations were retrieved. Of 4,371 referred patients, 466 (239 males and 227 females) were laboratory diagnosed with intestinal parasites, with a period prevalence of 10.7%. Blastocystis hominis (B. hominis) and Giardia lamblia (G. lamblia) were the most frequent intestinal parasites. More than half of patients aged ³ 18 years had a low level of educational attainment (e.g. illiterate, primary school, high school) (170/331, 54.1%). Further, majority of patients were homemakers (42.3%, 140/331) or workers (28.1%, 93/331) employed in various business settings such as food industry and construction. Findings of this study showed that intestinal parasitic infections are still a major public health challenge in Iran that needs to be addressed. We believe that public education, improving sanitation conditions of underdeveloped areas/communities, community involvement, and supporting evidence-based practice/programs are the major keys to success in preventing the spread of intestinal parasitic infections in Iran.
Resumo:
Hepatitis B virus (HBV) infection is endemic in Nigeria and constitutes a public health menace. The prevalence of HBV infection in many professional groups has been described in Nigeria. However, literature on HBV infection among female sex workers (FSW) in Nigeria is scanty. FSW in Nigeria are not subjected to a preventive control of HBV infection. This study assesses the extent of spread of HBV among FSW in Nigeria. Seven hundred and twenty (n = 720) FSW (mean age = 26.7 years) were tested for hepatitis B surface antigen (HBsAg) by a double antibody sandwich ELISA method. The overall HBV prevalence among the FSW was 17.1%. FSWs between the ages of 31-35 year (20.5%) and those with 'age-at-first-sex' below 10 years of age (28%) were most affected. This high prevalence of a vaccine preventable disease is unacceptable, therefore, vaccination of this high risk HBV reservoir group should be considered worthwhile.
Resumo:
HIV+ patients often develop alterations of the plasma lipids that may implicate in development of premature coronary artery disease. High-density lipoprotein (HDL) has an important role in preventing atherogenesis and the aim of this study was to investigate aspects of HDL function in HIV+ patients. HIV+ patients (n = 48) and healthy control subjects (n = 45) of both sexes with similar age were studied. Twenty-five were not being treated with antiretroviral agents, 13 were under reverse transcriptase inhibitor nucleosidic and non-nucleosidic (NRTI+NNRTI) and 10 were under NRTI + protease inhibitors (NRTI+PI) treatment. Paraoxonase 1 (PON1) activity and the transfer of free and esterified cholesterol, tryglicerides and phospholipids from a lipidic nanoemulsion to HDL were analyzed. In comparison with healthy controls, HIV+ patients presented low PON-1 activity and diminished transfer of free cholesterol and tryglicerides. In contrast, phospholipid transfer was increased in those patients, whereas the transfer of cholesteryl esters was unchanged. NRTI+NNRTI increases the transfer of cholesteryl esters and triglycerides but in NRTI+PI there was no difference in respect to non-treated HIV+ patients. HDL from HIV+ patients has smaller antioxidant properties, as shown by lower PON-1 activity, and the transfer of lipids to this lipoprotein fraction is also altered, suggesting that HDL function is defective in those patients.
Resumo:
The main serological marker for the diagnosis of recent toxoplasmosis is the specific IgM antibody, along with IgG antibodies of low avidity. However, in some patients these antibodies may persist long after the acute/recent phase, contributing to misdiagnosis in suspected cases of toxoplasmosis. In the present study, the diagnostic efficiency of ELISA was evaluated, with the use of peptides derived from T. gondii ESA antigens, named SAG-1, GRA-1 and GRA-7. In the assay referred to, we studied each of these peptides individually, as well as in four different combinations, as Multiple Antigen Peptides (MAP), aiming to establish a reliable profile for the acute/recent toxoplasmosis with only one patient serum sample. The diagnostic performance of the assay using MAP1, with the combination of SAG-1, GRA-1 and GRA-7 peptides, demonstrated better discrimination of the acute/recent phase from non acute/recent phase of toxoplasmosis. Our results show that IgM antibodies to MAP1 may be useful as a serological marker, enhancing the diagnostic efficiency of the assay for acute/recent phase of toxoplasmosis.
Resumo:
Adenovirus (AdV) respiratory infections are usually described as being associated with high mortality rates. Laboratory diagnosis is essential for the establishment of the appropriate therapy, and for guiding the implementation of preventive measures in order to prevent the spread of the infection. Aiming to analyze the sensitivity and specificity of the laboratorial diagnosis methods available, we compared antigen detection by indirect immunofluorescence assay (IF), and a specific nested polymerase chain reaction (PCR), to detect AdV in respiratory samples collected from patients admitted to hospital with acute respiratory disease. Positive samples were inoculated into a cell culture to confirm the results. We analyzed 381 samples from the nasopharyngeal aspirates collected during the year 2008; of these, 2.6% tested were positive for adenovirus through IF and 10% through PCR; positive isolation was obtained in 40% and 26% of these cases, respectively. Most infected patients were children under six months of age, and despite of the fact that a significant number of patients required intensive care, the mortality rate was low (5%). In conclusion, molecular methods were found to be useful for rapid diagnosis of adenovirus infections with higher sensitivity than antigen detection; their introduction permitted a significant increase in diagnoses of adenovirus infections.
Resumo:
Schistosomiasis constitutes a major public health problem, with an estimated 200 million individuals infected worldwide and 700 million people living in risk areas. In Brazil there are areas of high, medium and low endemicity. Studies have shown that in endemic areas with a low prevalence of Schistosoma infection the sensitivity of parasitological methods is clearly reduced. Consequently diagnosis is often impeded due to the presence of false-negative results. The aim of this study is to present the PCR reamplification (Re-PCR) protocol for the detection of Schistosoma mansoni in samples with low parasite load (with less than 100 eggs per gram (epg) of feces). Three methods were used for the lysis of the envelopes of the S. mansoni eggs and two techniques of DNA extraction were carried out. Extracted DNA was quantified, and the results suggested that the extraction technique, which mixed glass beads with a guanidine isothiocyanate/phenol/chloroform (GT) solution, produced good results. PCR reamplification was conducted and detection sensitivity was found to be five eggs per 500 mg of artificially marked feces. The results achieved using these methods suggest that they are potentially viable for the detection of Schistosoma infection with low parasite load.
Resumo:
Enteric parasitosis remains an important public health problem in many areas around the world including in Brazil, and it is frequently associated with poverty and lack of sanitation facilities. Research carried out over the course of a year revealed that 96.6% (28/29) of children randomly selected from a 'landless farm workers' settlement in Araras, São Paulo, aged 4 - 15 years, presented Giardia intestinalis cysts. After referral to the neighborhood Health Office, all the children received tinidazole, given as a single dose of 50 mg/kg and 12 months later, new fecal samples were collected and analyzed. Despite the low adherence to the study, a high percentage (64.3% - 9/14) of the children remained positive for the parasite. This study showed a high positivity of giardiasis in child residents of the settlement, even after treatment; adults were not sensitized to the study and did not collected and/or deliver children fecal samples. The precarious living conditions are consistent with a high susceptibility to parasitic diseases, suggesting that the treatment of the infected individuals without identifying and eradicating the means of contamination is simply a palliative measure.
Resumo:
SUMMARY High-risk human papillomavirus (hr-HPV) infection is necessary but not sufficient for cervical cancer development. Recently, P16INK4A gene silencing through hypermethylation has been proposed as an important cofactor in cervical carcinogenesis due to its tumor suppressor function. We aimed to investigate P16INK4A methylation status in normal and neoplastic epithelia and evaluate an association with HPV infection and genotype. This cross-sectional study was performed with 141 cervical samples from patients attending Hospital Moncorvo Filho, Rio de Janeiro. HPV detection and genotyping were performed through PCR and P16INK4A methylation by nested-methylation specific PCR (MSP). HPV frequency was 62.4% (88/141). The most common HPV were HPV16 (37%), HPV18 (16.3%) and HPV33/45(15.2%). An upward trend was observed concerning P16INK4A methylation and lesion degree: normal epithelia (10.7%), low grade lesions (22.9%), high grade (57.1%) and carcinoma (93.1%) (p < 0.0001). A multivariate analysis was performed to evaluate an association between methylation, age, tobacco exposure, HPV infection and genotyping. A correlation was found concerning methylation with HPV infection (p < 0.0001), hr-HPV (p = 0.01), HSIL (p < 0.0007) and malignant lesions (p < 0.0001). Since viral infection and epigenetic alterations are related to cervical carcinoma, we suggest that P16INK4A methylation profile maybe thoroughly investigated as a biomarker to identify patients at risk of cancer.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
A crescente necessidade de reduzir a dependência energética e a emissão de gases de efeito de estufa levou à adoção de uma série de políticas a nível europeu com vista a aumentar a eficiência energética e nível de controlo de equipamentos, reduzir o consumo e aumentar a percentagem de energia produzida a partir de fontes renováveis. Estas medidas levaram ao desenvolvimento de duas situações críticas para o setor elétrico: a substituição das cargas lineares tradicionais, pouco eficientes, por cargas não-lineares mais eficientes e o aparecimento da produção distribuída de energia a partir de fontes renováveis. Embora apresentem vantagens bem documentadas, ambas as situações podem afetar negativamente a qualidade de energia elétrica na rede de distribuição, principalmente na rede de baixa tensão onde é feita a ligação com a maior parte dos clientes e onde se encontram as cargas não-lineares e a ligação às fontes de energia descentralizadas. Isto significa que a monitorização da qualidade de energia tem, atualmente, uma importância acrescida devido aos custos relacionados com perdas inerentes à falta de qualidade de energia elétrica na rede e à necessidade de verificar que determinados parâmetros relacionados com a qualidade de energia elétrica se encontram dentro dos limites previstos nas normas e nos contratos com clientes de forma a evitar disputas ou reclamações. Neste sentido, a rede de distribuição tem vindo a sofrer alterações a nível das subestações e dos postos de transformação que visam aumentar a visibilidade da qualidade de energia na rede em tempo real. No entanto, estas medidas só permitem monitorizar a qualidade de energia até aos postos de transformação de média para baixa tensão, não revelando o estado real da qualidade de energia nos pontos de entrega ao cliente. A monitorização nestes pontos é feita periodicamente e não em tempo real, ficando aquém do necessário para assegurar a deteção correta de problemas de qualidade de energia no lado do consumidor. De facto, a metodologia de monitorização utilizada atualmente envolve o envio de técnicos ao local onde surgiu uma reclamação ou a um ponto de medição previsto para instalar um analisador de energia que permanece na instalação durante um determinado período de tempo. Este tipo de monitorização à posteriori impossibilita desde logo a deteção do problema de qualidade de energia que levou à reclamação, caso não se trate de um problema contínuo. Na melhor situação, o aparelho poderá detetar uma réplica do evento, mas a larga percentagem anomalias ficam fora deste processo por serem extemporâneas. De facto, para detetar o evento que deu origem ao problema é necessário monitorizar permanentemente a qualidade de energia. No entanto este método de monitorização implica a instalação permanente de equipamentos e não é viável do ponto de vista das empresas de distribuição de energia já que os equipamentos têm custos demasiado elevados e implicam a necessidade de espaços maiores nos pontos de entrega para conter os equipamentos e o contador elétrico. Uma alternativa possível que pode tornar viável a monitorização permanente da qualidade de energia consiste na introdução de uma funcionalidade de monitorização nos contadores de energia de determinados pontos da rede de distribuição. Os contadores são obrigatórios em todas as instalações ligadas à rede, para efeitos de faturação. Tradicionalmente estes contadores são eletromecânicos e recentemente começaram a ser substituídos por contadores inteligentes (smart meters), de natureza eletrónica, que para além de fazer a contagem de energia permitem a recolha de informação sobre outros parâmetros e aplicação de uma serie de funcionalidades pelo operador de rede de distribuição devido às suas capacidades de comunicação. A reutilização deste equipamento com finalidade de analisar a qualidade da energia junto dos pontos de entrega surge assim como uma forma privilegiada dado que se trata essencialmente de explorar algumas das suas características adicionais. Este trabalho tem como objetivo analisar a possibilidade descrita de monitorizar a qualidade de energia elétrica de forma permanente no ponto de entrega ao cliente através da utilização do contador elétrico do mesmo e elaborar um conjunto de requisitos para o contador tendo em conta a normalização aplicável, as características dos equipamentos utilizados atualmente pelo operador de rede e as necessidades do sistema elétrico relativamente à monitorização de qualidade de energia.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.