970 resultados para Heart-rate Patterns
Resumo:
The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.
Resumo:
STUDY OBJECTIVE; To evaluate interactive effects of volemic status and positive end-expiratory pressure (PEEP) on the plasma levels of atrial natriuretic factor (ANF) in assist-controlled mechanical ventilation (MV). DESIGN: Three successive protocols applied in randomized order to each participant. SETTING: Clinical investigation laboratory. PARTICIPANTS: Twenty-one young, healthy adults. INTERVENTIONS: The three protocols were as follows: (1) MV+PEEP, normovolemia; (2) MV+PEEP, hypervolemia; and (3) spontaneous breathing (SB), hypervolemia. In protocols 1 and 2, a preliminary period of SB lasting 2 h was followed by MV alone (0.5 h), MV+20 cm H2O PEEP (1 h), and a recovery period of SB (1.5 h). Hypervolemia was induced by the continuous i.v. infusion of 3 L of 0.9% NaCl in 5 h (protocols 2 and 3). MEASUREMENTS AND RESULTS: Heart rate, BP, and the plasma levels of immunoreactive ANF and catecholamines were measured serially. During hypervolemia, ANF significantly decreased when PEEP was added to MV (protocol 2: from 31.1 +/- 2.7 to 20.7 +/- 1.5 fmol/mL; p < 0.01). This did not occur in normovolemia (protocol 1: from 20.0 +/- to 16.7 +/- 1.2 fmol/mL; p = NS). The different effects of MV+PEEP in normovolemia and hypervolemia were not related to differences in circulating catecholamine levels. CONCLUSIONS: These results demonstrate for the first time (to our knowledge) that volemic status modulates the response of plasma ANF to PEEP in humans. The role of ANF in the water and salt retention induced by MV with PEEP might be limited to hypervolemic conditions.
Resumo:
SUMMARY : The traditional medical advice for pregnant women has been to reduce their physical activity (PA) levels. The advice was based on concerns that exercise could affect pregnancy outcomes by increasing core body temperature, by increasing the risk of maternal musculoskeletal injury and by altering the transplacental transport of oxygen and nutrients to maternal skeletal muscle rather than to the developing foetus. In the meantime, several studies have provided new information on adaptation of the pregnant woman and her foetus to moderate PA. New investigations have shown no adverse maternal or neonatal outcomes, abnormal foetal growth, increase in early pregnancy loss, or late pregnancy complications. Moreover, enrolment in moderate PA has proven to result in marked health benefits including improved maternal cardiovascular function, reduction of excessive weight gain and fat retention, less complicated labour, improved foetal stress tolerance and neurobehavioral maturation. In view of the beneficial effects, current recommendations encourage healthy pregnant women to engage in 30 minutes of moderate PA on most, if not all, days of the week. This thesis work addressed several questions. Firstly, it examined whether compliance with the recommended levels of PA during pregnancy results in better preparedness for the sudden physical exertion of labour and delivery. Secondly, it measured PA during pregnancy as compared to postpartum. Lastly, it assessed the influence of pre-pregnancy body mass index on gestational resting metabolic rate. Data collection was conducted on healthy women living in Switzerland during the third trimester of pregnancy and postpartum. Total and activity energy expenditure was assessed through 24-hour heart rate and accelerations recordings, and cardiovascular fitness through an individual step-test. Information related to pregnancy, labour and delivery was collected from medical records. The results indicate that a minimum 30 min of moderate PA per day during pregnancy are associated with better cardiovascular fitness and lower risk of operative delivery with no negative effects on maternal and foetal conditions (study 1). Despite these benefits, a substantial proportion of pregnant women (39%) living in Switzerland do not meet the PA recommendations. The decrease in activity related energy expenditure during pregnancy compared to postpartum was measured to be around 100 kcal/day (~13%), whereas the total energy expenditure was found to increase by 300 kcal/day (study 2). Thus, the energy cost of late pregnancy in Switzerland corresponds to 200 kca/day. These findings are based on average values of the study group. It should be noted, however, that large variations in individual energy expenditure may occur depending on the pre-pregnancy body mass index (study 3). When adjusted to body weight, gestational resting metabolic rate is significantly lower among women of high pre-pregnancy body mass index compared to women of normal or low pre-pregnancy body mass index. This can be explained by the fact that resting metabolic rate is primarily a function of fat-free mass, and when expressed per kg body weight, it decreases as the percentage of body fat increases. If energy intake is not modified appropriately in order to match lower energy cost per kg body weight in overweight and obese women it will result in positive energy balance, thus contributing to the current trend towards increasing adiposity in affluent society. The results of these studies go beyond the current state of knowledge on PA and pregnancy (study 4) and provide valid evidence to guide clinical practice. In view of the current epidemic of sedentary behaviour and obesity related pathology, the findings contribute new and reliable information to public health policies regarding the effects of PA in pregnancy, an important period of life for both mother and infant.
Resumo:
Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.
Resumo:
Master athletes are often considered to represent the ideal rate of decline of aerobic function; however, most of the studies interested in active elderly people are often limited to people younger than 75. We aimed to determine the physiological adaptations and aerobic fitness in a selected European population of active octogenarians during maximal and submaximal exercise tests. Aerobic capacity was measured during maximal incremental tests on treadmill (TR) and cycle-ergometer (CE) and functional capacity during a 6-minute walk test (6-MWT) in 17 subjects aged 81.2 +/- 0.8 years. Pulmonary gas exchange and heart rate (HR) were continuously measured during the different exercise tests. Maximal oxygen consumption (V.O (2max)) on TR and CE was significantly higher than predicted values (TR: 28.7 +/- 1.2 vs. 17 +/- 0.5 ml . kg (-1) . min (-1); CE: 23 +/- 1.2 vs. 16 +/- 0.6 ml . kg (-1) . min (-1) for measured and predicted values respectively). V.O (2max) and HR (max), as well as V.O (2) and HR at the ventilatory threshold (V.O (2)T (V.E) and HR T (V.E)) were significantly higher on TR than on CE (HR (max): 144 +/- 4 vs. 138 +/- 4 bpm; V.O (2)T (V.E): 22.5 +/- 0.8 vs. 17.7 +/- 0.9 ml . kg (-1) . min (-1) for TR and CE respectively). V.O (2)T (V.E) and HR T (V.E) on TR were equivalent to V.O (2) and HR measured during the 6-MWT. HR T (V.E) on TR and mean HR during the 6-MWT were strongly correlated (R = 0.82, p < 0.01). Maintenance of regular physical activity provides high aerobic fitness, in octogenarians, as was shown by the higher values of our subjects in comparison to predicted values. Moreover, the close relation between the intensity developed at T (V.E) on TR and 6-MWT could support the idea that a walk test is a submaximal test performed at high intensity that could provide a basis for exercise prescription in an individualized manner in active elderly people.
Resumo:
To study the functional role of individual alpha1-adrenergic (AR) subtypes in blood pressure (BP) regulation, we used mice lacking the alpha1B-AR and/or alpha1D-AR with the same genetic background and further studied their hemodynamic and vasoconstrictive responses. Both the alpha1D-AR knockout and alpha1B-/alpha1D-AR double knockout mice, but not the alpha1B-AR knockout mice, had significantly (p < 0.05) lower levels of basal systolic and mean arterial BP than wild-type mice in nonanesthetized condition, and they showed no significant change in heart rate or in cardiac function, as assessed by echocardiogram. All mutants showed a significantly (p < 0.05) reduced catecholamine-induced pressor and vasoconstriction responses. It is noteworthy that the infusion of norepinephrine did not elicit any pressor response at all in alpha1B-/alpha1D-AR double knockout mice. In an attempt to further examine alpha1-AR subtype, which is involved in the genesis or maintenance of hypertension, BP after salt loading was monitored by tail-cuff readings and confirmed at the endpoint by direct intra-arterial recording. After salt loading, alpha1B-AR knockout mice developed a comparable level of hypertension to wild-type mice, whereas mice lacking alpha1D-AR had significantly (p < 0.05) attenuated BP and lower levels of circulating catecholamines. Our data indicated that alpha1B- and alpha1D-AR subtypes participate cooperatively in BP regulation; however, the deletion of the functional alpha1D-AR, not alpha1B-AR, leads to an antihypertensive effect. The study shows differential contributions of alpha1B- and alpha1D-ARs in BP regulation.
Resumo:
The blood pressure (BP), heart rate (HR), and humoral effects of single intravenous (i.v.) doses of the angiotensin-converting enzyme (ACE) inhibitor captopril was investigated in five normotensive healthy volunteers. Each subject received at 1-week intervals a bolus dose of either captopril (1, 5, and 25 mg) or its vehicle. The study was conducted in a single-blind fashion, and the order of treatment phases was randomized. The different doses of captopril had no acute effect on BP and HR. They induced a dose-dependent decrease in plasma ACE activity and plasma angiotensin II levels. The angiotensin-(1-8) octapeptide was isolated by solid-phase extraction and high-performance liquid chromatography (HPLC) prior to radioimmunoassay (RIA). All three doses of captopril reduced circulating angiotensin II levels within 15 min of drug administration. Only with the 25-mg dose was the angiotensin II concentration below the detection limit at 15 min and still significantly reduced 90 min after drug administration. Simultaneous and progressive decreases in plasma aldosterone levels were observed both with ACE inhibition and during vehicle injection, but the relative fall was more pronounced after captopril administration. No adverse reaction was noticed. These results demonstrate that captopril given parenterally blocks the renin-angiotensin system in a dose-dependent manner. Only with the dose of 25 mg was the inhibition of plasma-converting enzyme activity and the reduction of plasma angiotensin II sustained for at least 1 1/2 h.
Resumo:
BACKGROUND: Isolated congenital atrioventricular block (CAVB) diagnosed in utero is associated with a high morbidity and mortality. Prognosis is especially poor when heart rate drops below 55 beats per minute (bpm) and when fetal hydrops develops. We describe the natural history and outcome of 24 infants with isolated CAVB diagnosed in utero, review the literature, and assess the risk factors that could predict outcome. METHODS: This was a retrospective multicenter study of 24 patients with isolated CAVB diagnosed in utero. RESULTS: CAVB was detected at a mean gestational age (GA) of 24.7 +/- 5.1 weeks. Ten fetuses initially presented with complete heart block. Low heart rate or incomplete heart block was the first documentation of bradyarrhythmia in the other 14 fetuses. In 11 of them, CAVB developed during pregnancy after a median time of 3 (range 1-16) weeks. Fetal hydrops developed in 10 of 24 (42%) fetuses at a mean GA of 27.6 +/- 5.1 weeks. Hydropic fetuses showed lower heart rates during pregnancy (47 +/- 10 bpm) than non-hydropic fetuses (57 +/- 10 bpm). There were three intrauterine deaths; all were hydropic and female. Nine viable females and 12 males were born at a mean GA of 37.1 +/- 6.1 weeks with an average birth weight of 3097 +/- 852 g. Fifteen CAVB patients required pacemaker (PM) intervention, 10 of them immediately after birth. Dilated cardiomyopathy (DCM) developed in three infants of whom two died of congestive heart failure, shortly after the diagnosis was made; one is still alive. Mortality before or after birth was 21%, and was associated with heart rates below 50 bpm and development of fetal hydrops. Poor outcome, defined as death, PM implantation, or development of DCM, occurred in 83% of cases and was associated with heart rates below 60 bpm during pregnancy. CONCLUSIONS: Isolated CAVB diagnosed in utero is associated with high morbidity and mortality. Patients who develop fetal hydrops show lower heart rates during pregnancy than patients who do not. A fetal heart rate below 50 bpm and development of fetal hydrops is associated with increased mortality. Rates below 60 bpm are associated with PM requirement and/or DCM.
Resumo:
This study describes major electrocardiogram (ECG) measurements and diagnoses in a population of African individuals; most reference data have been collected in Caucasian populations and evidence exists for interethnic differences in ECG findings. This study was conducted in the Seychelles islands (Indian Ocean) and included 709 black individuals (343 men and 366 women) aged 25 to 64 years randomly selected from the general population. Resting ECG were recorded by using a validated ECG unit equipped with a measurement and interpretation software (Cardiovit AT-6, Schiller, Switzerland). The epidemiology of 14 basic ECG measurements, 6 composite criteria for left ventricular hypertrophy and 19 specific ECG diagnoses including abnormal rhythms, conduction abnormalities, repolarization abnormalities, and myocardial infarction were examined. Substantial gender and age differences were found for several ECG parameters. Moreover, tracings recorded in African individuals of the Seychelles differed from those collected similarly in Caucasian populations in many respects. For instance, heart rate was approximately 5 beats per minute lower in the African individuals than in selected Caucasian populations, prevalence of first degree atrio-ventricular block was especially high (4.8%), and the average Sokolow-Lyon voltage was markedly higher in African individuals of the Seychelles compared with black and white Americans. The integrated interpretation software detected "old myocardial infarction" in 3.8% of men and 0% of women and "old myocardial infarction possible" in 6.1% and 3%, respectively. Cardiac infarction injury scores are also provided. In conclusion, the study provides reference values for ECG findings in a specific population of people of African descent and stresses the need to systematically consider gender, age, and ethnicity when interpreting ECG tracings in individuals.
Resumo:
In a prospective nonrandomized study, using each baby as his or her own control, we compared intracranial pressure (anterior fontanel pressure as measured with the Digilab pneumotonometer), cerebral perfusion pressure, BP, heart rate, transcutaneous Po2, and transcutaneous Pco2 before, during, and after endotracheal suctioning, with and without muscle paralysis, in 28 critically ill preterm infants with respiratory distress syndrome. With suctioning, there was a small but significant increase in intracranial pressure in paralyzed patients (from 13.7 [mean] +/- 4.4 mm Hg [SD] to 15.8 +/- 5.2 mm Hg) but a significantly larger (P less than .001) increase when they were not paralyzed (from 12.5 +/- 3.6 to 28.5 +/- 8.3 mm Hg). Suctioning led to a slight increase in BP with (from 45.3 +/- 9.1 to 48.0 +/- 8.7 mm Hg) and without muscle paralysis (from 45.1 +/- 9.4 to 50.0 +/- 11.7 mm Hg); but there was no significant difference between the two groups. The cerebral perfusion pressure in paralyzed infants did not show any significant change before, during, and after suctioning (31.5 +/- 9.1 mm Hg before v 32.0 +/- 8.7 mm Hg during suctioning), but without muscle paralysis cerebral perfusion pressure decreased (P less than .001) from 32.8 +/- 9.7 to 21.3 +/- 13.1 mm Hg. Suctioning induced a slight decrease in mean heart rate and transcutaneous Po2, but pancuronium did not alter these changes. There was no statistical difference in transcutaneous Pco2 before, during, and after suctioning with and without muscle paralysis.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
This study examined the validity and reliability of a sequential "Run-Bike-Run" test (RBR) in age-group triathletes. Eight Olympic distance (OD) specialists (age 30.0 ± 2.0 years, mass 75.6 ± 1.6 kg, run VO2max 63.8 ± 1.9 ml· kg(-1)· min(-1), cycle VO2peak 56.7 ± 5.1 ml· kg(-1)· min(-1)) performed four trials over 10 days. Trial 1 (TRVO2max) was an incremental treadmill running test. Trials 2 and 3 (RBR1 and RBR2) involved: 1) a 7-min run at 15 km· h(-1) (R1) plus a 1-min transition to 2) cycling to fatigue (2 W· kg(-1) body mass then 30 W each 3 min); 3) 10-min cycling at 3 W· kg(-1) (Bsubmax); another 1-min transition and 4) a second 7-min run at 15 km· h(-1) (R2). Trial 4 (TT) was a 30-min cycle - 20-min run time trial. No significant differences in absolute oxygen uptake (VO2), heart rate (HR), or blood lactate concentration ([BLA]) were evidenced between RBR1 and RBR2. For all measured physiological variables, the limits of agreement were similar, and the mean differences were physiologically unimportant, between trials. Low levels of test-retest error (i.e. ICC <0.8, CV<10%) were observed for most (logged) measurements. However [BLA] post R1 (ICC 0.87, CV 25.1%), [BLA] post Bsubmax (ICC 0.99, CV 16.31) and [BLA] post R2 (ICC 0.51, CV 22.9%) were least reliable. These error ranges may help coaches detect real changes in training status over time. Moreover, RBR test variables can be used to predict discipline specific and overall TT performance. Cycle VO2peak, cycle peak power output, and the change between R1 and R2 (deltaR1R2) in [BLA] were most highly related to overall TT distance (r = 0.89, p < 0. 01; r = 0.94, p < 0.02; r = 0.86, p < 0.05, respectively). The percentage of TR VO2max at 15 km· h(-1), and deltaR1R2 HR, were also related to run TT distance (r = -0.83 and 0.86, both p < 0.05).
Resumo:
It is widely accepted that pharmacologic reduction of the blood pressure of hypertensive patients reduces the risk of at least some of the major cardiovascular complications (1-5). All major studies were carried out before orally active converting enzyme inhibitors had become available. In other words, very effective antihypertensive drugs have been around for quite some time and have already proven their efficacy. Therefore, the considerable enthusiasm that has developed during the very recent years for the new converting enzyme inhibitors should be evaluated in the light of previously available antihypertensive drugs, the more so, as drugs cheaper than converting enzyme inhibiting agents are presently available. Thus, the increased expense when using this new class of antihypertensive compounds should be justified by a therapeutic gain. When evaluating a class of antihypertensive drugs such as converting enzyme inhibitors, there are basically three main considerations: What is their efficacy in long-term use? This includes the effect on blood pressure, on heart, on hemodynamics, and on blood flow distribution. What are the metabolic effects? What is the effect on sodium and potassium excretion? How are the serum lipids affected by its use? Are there any untoward effects related either to the chemical structure of the compound per se or rather to the approach? In particular, are there any central effects of the drug which can cause discomfort to the patient? The following discussion has the principal aim to review these aspects with chronic use of oral converting enzyme inhibiting agents without, however, even attempting to provide an exhaustive review of the subject.
Resumo:
How long induced moods last is a critical question for mood research but has been only poorly addressed. In particular, physiological parameters have been rarely included to assess the effectiveness of mood induction procedures. We investigated the persistence of four different moods (positive high-arousal, positive low-arousal, negative high-arousal and negative low-arousal) induced by film clips during a computer task. We measured subjective affective state, respiration, skin conductance level (SCL), heart rate, and corrugator activity. People who watched the two negative clips reported more negative valence after the task and showed more facial frowning and lower SCL during the task than the people who watched the two positive clips. No arousal effects persisted throughout the task. The results suggest that induced changes in the valence dimension of moods are maintained throughout an intervening task and are physiologically best reflected by corrugator activity and SCL, whereas induced changes in the arousal dimension dissipate quickly. The implications of these findings for mood research are discussed. [Authors]
Resumo:
This study assessed the pharmacodynamic and pharmacokinetic effects of the interaction between the selective norepinephrine (NE) transporter inhibitor reboxetine and 3,4-methylenedioxymethamphetamine (MDMA, "ecstasy") in 16 healthy subjects. The study used a double-blind, placebo-controlled crossover design. Reboxetine reduced the effects of MDMA including elevations in plasma levels of NE, increases in blood pressure and heart rate, subjective drug high, stimulation, and emotional excitation. These effects were evident despite an increase in the concentrations of MDMA and its active metabolite 3,4-methylenedioxyamphetamine (MDA) in plasma. The results demonstrate that transporter-mediated NE release has a critical role in the cardiovascular and stimulant-like effects of MDMA in humans.
Resumo:
The effect of acute intravenous dopamine (DA) administration at three sequential (but randomized) infusion rates was studied in eight young male volunteers. DA was infused at 2.5, 5, and 10 micrograms.kg-1.min-1. O2 consumption (VO2) and CO2 production (VCO2) were measured continuously by means of a computerized indirect calorimeter (blood system). In response to the 5- and 10-micrograms.kg-1.min-1 DA infusion rates, a significant increase (P less than 0.01) in VO2 corresponding to a 6% (range, 3-10) and 15% (range, 12-23) increase, respectively, of preinfusion values was observed. In contrast, at the low dose (2.5 micrograms.kg-1.min-1), DA induced no significant change in VO2. Cardiac output (Qc) increased significantly after the three DA administration rates [19% (range, 0-42), 34% (range, 17-71), and 25% (range, -3 to +47)] for the doses 2.5, 5, and 10 micrograms.-kg-1.min-1, respectively. The increase in O2 delivery (QO2) outweighed VO2 at all administration rates despite the relative drop in QO2 at the maximal DA administration rate. These results indicate that in humans DA improves net O2 supply to tissues proportionally more than it increases VO2 at all doses used in the present study.