903 resultados para Fragmento TrkB-ICD


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with an implantable cardioverter defibrillator (ICD) have an ongoing risk of sudden incapacitation that might cause harm to others while driving a car. Driving restrictions vary across different countries in Europe. The most recent recommendations for driving of ICD patients in Europe were published in 1997 and focused mainly on patients implanted for secondary prevention. In recent years there has been a vast increase in the number of patients with an ICD and in the percentage of patients implanted for primary prevention. The EHRA task force on ICD and driving was formed to reassess the risk of driving for ICD patients based on the literature available. The recommendations are summarized in the following table and are further explained in the document, (Table see text). Driving restrictions are perceived as difficult for patients and their families, and have an immediate consequence for their lifestyle. To increase the adherence to the driving restrictions, adequate discharge of education and follow-up of patients and family are pivotal. The task force members hope this document may serve as an instrument for European and national regulatory authorities to formulate uniform driving regulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Phosphatidylethanol (PEth) is a direct ethanol metabolite, and has recently attracted attention as biomarker of ethanol intake. The aims of the current study are: (1) to characterize the normalization time of PEth in larger samples than previously conducted; (2) to elucidate potential gender differences; and (3) to report the correlation of PEth with other biomarkers and self-reported alcohol consumption. Fifty-seven alcohol-dependent patients (ICD 10 F 10.25; 9 females, 48 males) entering medical detoxification at three study sites were enrolled. The study sample was comprised of 48 males and 9 females, with mean age 43.5. Mean gamma glutamyl transpeptidase (GGT) was 209.61 U/l, average mean corpuscular volume (MCV) was 97.35 fl, mean carbohydrate deficient transferrin (%CDT) was 8.68, and mean total ethanol intake in the last 7 days was 1653 g. PEth was measured in heparinized whole blood with a high-pressure liquid chromatography method, while GGT, MCV and %CDT were measured using routine methods. PEth levels at day 1 of detoxification ranged between 0.63 and 26.95 micromol/l (6.22 mean, 4.70 median, SD 4.97). There were no false negatives at day 1. Sensitivities for the other biomarkers were 40.4% for MCV, 73.1% for GGT and 69.2% for %CDT, respectively. No gender differences were found for PEth levels at any time point. Our data suggest that PEth is (1) a suitable intermediate term marker of ethanol intake in both sexes; and (2) sensitivity is extraordinary high in alcohol dependent patients. The results add further evidence to the data that suggest that PEth has potential as a candidate for a sensitive and specific biomarker, which reflects longer-lasting intake of higher amounts of alcohol and seemingly has the above mentioned certain advantages over traditional biomarkers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with left ventricular noncompaction (LVNC) have an increased risk for life-threatening ventricular arrhythmias. The benefit from implantable cardioverter-defibrillators (ICD) in these patients has been investigated only in small series. Therefore, the aim of the present study was to analyze the clinical outcome of a larger population of patients with LVNC who were treated with an ICD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data on long-term renal function are scarce for ileal conduit diversion (ICD) and even rarer for orthotopic ileal bladder substitution (BS).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The implantable cardioverter defibrillator (ICD) is the gold standard therapy to prevent life-threatening arrhythmias. Phobic anxiety predicts ventricular arrhythmia in coronary heart disease patients, but little is known about phobic anxiety in ICD patients. This study aimed to identify determinants and the course of phobic anxiety in ICD patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background There is a lack of international research on suicide by drug overdose as a preventable suicide method. Sex- and age-specific rates of suicide by drug self-poisoning (ICD-10, X60-64) and the distribution of drug types used in 16 European countries were studied, and compared with other self-poisoning methods (X65-69) and intentional self-injury (X70-84). Methods Data for 2000-04/05 were collected from national statistical offices. Age-adjusted suicide rates, and age and sex distributions, were calculated. Results No pronounced sex differences in drug self-poisoning rates were found, either in the aggregate data (males 1.6 and females 1.5 per 100,000) or within individual countries. Among the 16 countries, the range (from some 0.3 in Portugal to 5.0 in Finland) was wide. 'Other and unspecified drugs' (X64) were recorded most frequently, with a range of 0.2-1.9, and accounted for more than 70% of deaths by drug overdose in France, Luxembourg, Portugal and Spain. Psychotropic drugs (X61) ranked second. The X63 category ('other drugs acting on the autonomic nervous system') was least frequently used. Finland showed low X64 and high X61 figures, Scotland had high levels of X62 ('narcotics and hallucinogens, not elsewhere classified') for both sexes, while England exceeded other countries in category X60. Risk was highest among the middle-aged everywhere except in Switzerland, where the elderly were most at risk. Conclusions Suicide by drug overdose is preventable. Intentional self-poisoning with drugs kills as many males as females. The considerable differences in patterns of self-poisoning found in the various European countries are relevant to national efforts to improve diagnostics of suicide and appropriate specific prevention. The fact that vast majority of drug-overdose suicides came under the category X64 refers to the need of more detailed ICD coding system for overdose suicides is needed to permit better design of suicide-prevention strategies at national level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mutations in the plakoglobin (JUP) gene have been identified in arrhythmogenic right ventricular cardiomyopathy (ARVC) patients. However, the mechanisms underlying plakoglobin dysfunction involved in the pathogenesis of ARVC remain poorly understood. Plakoglobin is a component of both desmosomes and adherens junctions located at the intercalated disc (ICD) of cardiomyocytes, where it functions to link cadherins to the cytoskeleton. In addition, plakoglobin functions as a signaling protein via its ability to modulate the Wnt/beta-catenin signaling pathway. To investigate the role of plakoglobin in ARVC, we generated an inducible cardiorestricted knockout (CKO) of the plakoglobin gene in mice. Plakoglobin CKO mice exhibited progressive loss of cardiac myocytes, extensive inflammatory infiltration, fibrous tissue replacement, and cardiac dysfunction similar to those of ARVC patients. Desmosomal proteins from the ICD were decreased, consistent with altered desmosome ultrastructure in plakoglobin CKO hearts. Despite gap junction remodeling, plakoglobin CKO hearts were refractory to induced arrhythmias. Ablation of plakoglobin caused increase beta-catenin stabilization associated with activated AKT and inhibition of glycogen synthase kinase 3beta. Finally, beta-catenin/TCF transcriptional activity may contribute to the cardiac hypertrophy response in plakoglobin CKO mice. This novel model of ARVC demonstrates for the first time how plakoglobin affects beta-catenin activity in the heart and its implications for disease pathogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mortality among HIV-infected persons is decreasing, and causes of death are changing. Classification of deaths is hampered because of low autopsy rates, frequent deaths outside of hospitals, and shortcomings of International Statistical Classification of Diseases and Related Health Problems (ICD-10) coding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Recently, several cases of symptomatic and/or electrically detectable intracardiac inside-out abrasions in silicon-coated Riata® and Riata® ST leads have been described. However, the prevalence in asymptomatic patients with unremarkable implantable cardioverter defibrillator (ICD) interrogation is unknown. The aim of this study was to determine the prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads. METHODS: All 52 patients with an active silicone-coated Riata® and Riata® ST lead followed up in our outpatient clinic were scheduled for a premature ICD interrogation and a biplane chest radiograph. When an intracardiac inside-out abrasion was suspected, this finding was confirmed by fluoroscopy. RESULTS: Mean time since implantation was 71±18months. An intracardiac inside-out abrasion was confirmed by fluoroscopy in 6 patients (11.5%). Mean time from lead implantation to detection of intracardiac inside-out abrasion was 79±14months. In all patients with an intracardiac inside-out abrasion, ICD interrogation showed normal and stable electrical parameters. Retrospectively, in 4 of these 6 patients, a coronary angiography performed 25±18months before diagnosis of intracardiac inside-out abrasion already showed the defect. Despite undetected intracardiac inside-out abrasion, 2 of these 4 patients experienced adequate antitachycardia pacing and ICD-shocks. ICD leads were replaced in all 6 patients. CONCLUSIONS: The prevalence of asymptomatic intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST leads is higher than 10% when assessed by fluoroscopy, and most intracardiac inside-out abrasions are not detectable by ICD interrogation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digital signal processing (DSP) techniques for biological sequence analysis continue to grow in popularity due to the inherent digital nature of these sequences. DSP methods have demonstrated early success for detection of coding regions in a gene. Recently, these methods are being used to establish DNA gene similarity. We present the inter-coefficient difference (ICD) transformation, a novel extension of the discrete Fourier transformation, which can be applied to any DNA sequence. The ICD method is a mathematical, alignment-free DNA comparison method that generates a genetic signature for any DNA sequence that is used to generate relative measures of similarity among DNA sequences. We demonstrate our method on a set of insulin genes obtained from an evolutionarily wide range of species, and on a set of avian influenza viral sequences, which represents a set of highly similar sequences. We compare phylogenetic trees generated using our technique against trees generated using traditional alignment techniques for similarity and demonstrate that the ICD method produces a highly accurate tree without requiring an alignment prior to establishing sequence similarity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Clustering ventricular arrhythmias are the consequence of acute ventricular electrical instability and represent a challenge in the management of the growing number of patients with an implantable cardioverter-defibrillator (ICD). Triggering factors can rarely be identified. OBJECTIVES: Several studies have revealed seasonal variations in the frequency of cardiovascular events and life-threatening arrhythmias, and we sought to establish whether seasonal factors may exacerbate ventricular electrical instability leading to arrhythmia clusters and electrical storm. METHODS: Two hundred and fourteen consecutive defibrillator recipients were followed-up during 3.3 +/- 2.2 years. Arrhythmia cluster was defined as the occurrence of three or more arrhythmic events triggering appropriate defibrillator therapies within 2 weeks. Time intervals between two clusters were calculated for each month and each season, and were compared using Kruskal-Wallis test and Wilcoxon-Mann-Whitney test with Bonferroni adjustment. RESULTS: During a follow-up of 698 patient years, 98 arrhythmia clusters were observed in 51 patients; clustering ventricular arrhythmias were associated with temporal variables; they occurred more frequently in the winter and spring months than during the summer and fall. Accordingly, the time intervals between two clusters were significantly shorter during winter and spring (median and 95% CI): winter 16 (5-19), spring 11.5 (7-25), summer 34.5 (15-55), fall 50.5 (19-65), P = 0.0041. CONCLUSION: There are important seasonal variations in the incidence of arrhythmia clusters in ICD recipients. Whether these variations are related to environmental factors, change in physical activity, or psychological factors requires further study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Whereas most studies focus on laboratory and clinical research, little is known about the causes of death and risk factors for death in critically ill patients. METHODS: Three thousand seven hundred patients admitted to an adult intensive care unit (ICU) were prospectively evaluated. Study endpoints were to evaluate causes of death and risk factors for death in the ICU, in the hospital after discharge from ICU, and within one year after ICU admission. Causes of death in the ICU were defined according to standard ICU practice, whereas deaths in the hospital and at one year were defined and grouped according to the ICD-10 (International Statistical Classification of Diseases and Related Health Problems) score. Stepwise logistic regression analyses were separately calculated to identify independent risk factors for death during the given time periods. RESULTS: Acute, refractory multiple organ dysfunction syndrome was the most frequent cause of death in the ICU (47%), and central nervous system failure (relative risk [RR] 16.07, 95% confidence interval [CI] 8.3 to 31.4, p < 0.001) and cardiovascular failure (RR 11.83, 95% CI 5.2 to 27.1, p < 0.001) were the two most important risk factors for death in the ICU. Malignant tumour disease and exacerbation of chronic cardiovascular disease were the most frequent causes of death in the hospital (31.3% and 19.4%, respectively) and at one year (33.2% and 16.1%, respectively). CONCLUSION: In this primarily surgical critically ill patient population, acute or chronic multiple organ dysfunction syndrome prevailed over single-organ failure or unexpected cardiac arrest as a cause of death in the ICU. Malignant tumour disease and chronic cardiovascular disease were the most important causes of death after ICU discharge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE : To describe the methodology and to present the baseline findings of the Attention-deficit/hyperactivity Disorder Observational Research in Europe (ADORE) study, the primary objective of which is to describe the relationship between treatment regimen prescribed and quality of life of children with ADHD in actual practice. METHODS : In this 2-year prospective observational study, data on diagnosis, prescribed treatment and outcomes of ADHD were collected at seven time points by paediatricians and child psychiatrists on 1,573 children recruited in 10 European countries. The data presented here from the 1,478 patients included in the analyses describe the baseline condition, initial treatment regimen prescribed and quality of life of families with children with ADHD. RESULTS : Patients had a mean age of 9.0 years (SD 2.5) and 84% were male. Physicians diagnoses were made using DSM-IV (43 %), ICD-10 (32%) and both DSM-IV and ICD-10 (12 %). Mean age of awareness of a problem was 5.1 years, suggesting an average delay of approximately 4 years between awareness and diagnosis of ADHD. Baseline ADHD rating scale scores (physicianrated) indicated moderate to severe ADHD. Parent-rated SDQ scores were in agreement and suggested significant levels of co-existing problems. CGI-S, CGAS and CHIPCE scores also indicated significant impairment. Patients were offered the following treatments after the initial assessment: pharmacotherapy (25 %), psychotherapy (19 %), combination of pharmacotherapy and psychotherapy (25 %), other therapy (10 %) and no treatment (21 %). CONCLUSION : The ADORE study shows that ADHD is similarly recognised across 10 European countries and that the children are significantly impaired across a wide range of domains. In this respect, they resemble children described in previous ADHD samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: In patients with an implantable defibrillator (ICD), inappropriate ICD interventions alter the quality of life, may cause hospitalisations and limit cost-effectiveness. The aim of the study was to determine the incidence and causes of inappropriate ICD interventions, and to identify patients at risk. METHODS: For this observational longitudinal study, consecutive patients undergoing ICD implantation at the University Hospital of Berne were included in a registry. All stored electrograms of episodes triggering ICD interventions were systematically reviewed and analysed to determine whether ICD interventions were appropriate or inappropriate. Inappropriate ICD interventions were classified according to their cause, and risk factors were sought. RESULTS: 214 consecutive patients were followed during a median time of 2.7 years (3.7 years IQR, 698 patient years). 81 inappropriate ICD interventions occurred in 58 patients (27%). Factors triggering inappropriate ICD interventions included atrial fibrillation and flutter (n = 35, 44%), sinus tachycardia (n = 26, 32%), lead fracture (n = 12), recurrent self-terminating ventricular tachycardia (n = 5), double-counting due to T-wave oversensing (n = 3). The only identifiable risk factor for inappropriate ICD interventions was sustained ventricular tachycardia as index arrhythmia. CONCLUSIONS: An important proportion of ICD patients suffer inappropriate ICD interventions that are most commonly due to supraventricular arrhythmias. Patients with ventricular tachycardia prior to ICD implantation are at higher risk of inappropriate ICD interventions. Interventions aiming at decreasing the risk of inappropriate ICD interventions should be considered in these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: Alcohol ablation (AA) of the septum has been introduced as new therapy in hypertrophic cardiomyopathy (HCM). It was feared that iatrogenic myocardial infarction due to AA may induce re-entry tachyarrhythmias and increase sudden cardiac death. METHODS AND RESULTS: Twenty-four patients (mean age 52 years) underwent successful AA. Clinical follow-up (FU) ranged from 0.3 to 0.7 years (mean 2.8). One patient died (suicide) 4 years after AA. Left ventricular (LV) outflow gradient (peak-to-peak) decreased (median) after AA from 43 (IQR 25 to 4) mmHg to 1 (IQR 0 to 12) mmHg (rest) (p <0.001) and from 130 (IQR 75 to 165) mmHg to 13 (IQR 0 to 31) mmHg (postextrasystolic) (p <0.001). Transient AV block occurred in 22% (5/24) necessitating temporary pacing. A permanent pacemaker was implanted in 4% (1/24). NYHA-class was 2.5 (IQR 2.0 to 3.0) before and 1.5 (IQR 1.3 to 2.0) (p <0.001) after AA. During FU, 2 pacemakers were implanted due to bradycardia (no AV block). A right bundle branch block was found in 13% (2/24) before and 46 % (11/24) after AA (p = 0.003). Non-sustained ventricular tachycardia (NSVT) was observed in 13% (2/16) before and 22% (5/23) (p = 0.46) after AA. Two patients required ICD implantation. CONCLUSIONS: Long-term FU is excellent in HCM after AA. The pressure gradient drops below 25 mm Hg in 95% (23/24) of all patients. Transient AV block occurs in 22% (5/24), but permanent pacemaker implantation is rarely needed (13%, 2/24). Severe NSVT occurs in 13% (2/16) before and 22% (5/23) after AA but ICD implantation is only occasionally required.