935 resultados para Fractures.
Resumo:
Fractures or the medial wall of the orbit are uncommon and clinical signs are often discreet. This report was focused on isolated fractures of the medial wall of the orbit. Blow-out trauma is usually the cause. In these cases the clinical signs ranged from simple ecchymosis to blindness by haematoma of the orbital cone. Computed tomography is a major tool for diagnosis and making therapeutic indications for these fractures. Treatment depends on the oculomotor involvements as measured by forced duction tests.
Resumo:
BACKGROUND: Women with diabetes mellitus have an increased risk of cardiovascular disease (CVD) mortality and current treatment guidelines consider diabetes to be equivalent to existing CVD, but few data exist about the relative importance of these risk factors for total and cause-specific mortality in older women. METHODS: We studied 9704 women aged ≥65 years enrolled in a prospective cohort study (Study of Osteoporotic Fractures) during a mean follow-up of 13 years and compared all-cause, CVD and coronary heart disease (CHD) mortality among non-diabetic women without and with a prior history of CVD at baseline and diabetic women without and with a prior history of CVD. Diabetes mellitus and prior CVD (history of angina, myocardial infarction or stroke) were defined as self-report of physician diagnoses. Cause of death was adjudicated from death certificates and medical records when available (>95% deaths confirmed). Ascertainment of vital status was 99% complete. Log-rank tests for the rates of death and multivariate Cox hazard models adjusted for age, smoking, physical activity, systolic blood pressure, waist girth and education were used to compare mortality among the four groups with non-diabetic women without CVD as the referent group. Results are reported as adjusted hazard ratios (HR) with 95% confidence intervals (CI). RESULTS: At baseline mean age was 71.7±5.3 years, 7.0% reported diabetes mellitus and 14.5% reported prior CVD. 4257 women died during follow-up, 36.6% were attributed to CVD. The incidence of CVD death per 1000 person-years was 9.9 and 21.6 among non-diabetic women without and with CVD, respectively, and 23.8 and 33.3 among diabetic women without and with CVD, respectively. Compared to nondiabetic women without prior CVD, the risk of CVD mortality was elevated among both non-diabetic women with CVD (HR=1.82, CI: 1.60-2.07, P<0.001) and diabetic women without prior CVD (HR=2.24, CI: 1.87-2.69, P<0.001). CVD mortality was highest among diabetic women with CVD (HR=3.41, CI: 2.61-4.45, P<0.001). Compared to non-diabetic women with CVD, diabetic women without prior CVD had a significantly higher adjusted HR for total and CVD mortality (P<0.001 and P<0.05 respectively). CHD mortality did not differ significantly between non-diabetic women with CVD and diabetic women without prior CVD. CONCLUSION: Older diabetic women without prior CVD have a higher risk of all-cause and CVD mortality and a similar risk of CHD mortality compared to non-diabetic women with pre-existing CVD. For older women, these data support the equivalence of prior CVD and diabetes mellitus in current guidelines for the prevention of CVD.
Resumo:
Résumé Introduction et objectif : l'articulation du coude est vulnérable à l'enraidissement, en particulier après un traumatisme. Le but de cette étude est d'évaluer les résultats du traitement chirurgical des raideurs post-traumatiques du coude. Type d'étude : étude rétrospective de cohorte. Les patients : dix-huit patients ont été évalués cliniquement par un observateur indépendant dans un intervalle moyen de 16 mois (6 à 43) après avoir subi une arthrolyse ouverte du coude, avec comme indication opératoire une raideur post traumatique du coude. Les traumatismes subis étaient : 11 fractures isolées, 1 luxation isolée, 6 fracture-luxations complexes. Les prises en charge initiales étaient : non-chirurgicales pour 3 patients, résection de la tête radiale pour 1 patient, réduction ouverte et ostéosynthèse pour 14 patients. Les patients ont présenté des types de raideurs mixtes pour la plupart d'entre eux. Type d'intervention : arthrolyse ouverte du coude. Evaluation : la fonction du coude et la satisfaction des patients furent les principales données récoltées. Lacs de l'évaluation, les scores de SECEC (Société Européenne de Chirurgie d'Epaule et du Coude) ont été calculés. Une analyse radiologique a aussi été effectuée. Résultats : trois patients ont présenté des complications postopératoires mineures : 1 déhiscence de plaie, 1 infection sous-cutanée, 1 sérome. Aucune de ces complications n'a eu de répercussion sur le résultat final. Le gain d'amplitude articulaire moyen était de 40°, avec un gain moyen en flexion du coude de 14° (0°-45°), et de 26° en extension (5°-67°) Aucun patient n'a présenté d'instabilité du coude. Il n'y a pas eu de signe de progression d'arthrose sur les clichés radiographiques à la revue. Nous n'avons pas mis en évidence de rapport entre le type de raideur et la voie d'abord sur les résultats. Les patients ayant présentés les raideurs les plus importantes ont bénéficiés des meilleurs résultats en terme de mobilité (p<0.001). Les meilleurs résultats ont été obtenus pour les patients opérés dans la première année aptes le traumatisme initial (p=0.008). Le score SECEC moyen était de 88 points pour les coudes opérés (52-100), et de 96 points pour les coudes sains (88-100). Conclusion : l'arthrolyse ouverte confère de bons résultats pour les patients présentant une raideur post traumatique du coude. Les meilleurs résultats sont obtenus pour les patients présentant une raideur sévère, prise en charge dans l'année qui suit le traumatisme initial.
Resumo:
Investigations of solute transport in fractured rock aquifers often rely on tracer test data acquired at a limited number of observation points. Such data do not, by themselves, allow detailed assessments of the spreading of the injected tracer plume. To better understand the transport behavior in a granitic aquifer, we combine tracer test data with single-hole ground-penetrating radar (GPR) reflection monitoring data. Five successful tracer tests were performed under various experimental conditions between two boreholes 6 m apart. For each experiment, saline tracer was injected into a previously identified packed-off transmissive fracture while repeatedly acquiring single-hole GPR reflection profiles together with electrical conductivity logs in the pumping borehole. By analyzing depth-migrated GPR difference images together with tracer breakthrough curves and associated simplified flow and transport modeling, we estimate (1) the number, the connectivity, and the geometry of fractures that contribute to tracer transport, (2) the velocity and the mass of tracer that was carried along each flow path, and (3) the effective transport parameters of the identified flow paths. We find a qualitative agreement when comparing the time evolution of GPR reflectivity strengths at strategic locations in the formation with those arising from simulated transport. The discrepancies are on the same order as those between observed and simulated breakthrough curves at the outflow locations. The rather subtle and repeatable GPR signals provide useful and complementary information to tracer test data acquired at the outflow locations and may help us to characterize transport phenomena in fractured rock aquifers.
Resumo:
Isolated fractures of the zygomatic arch represent 5% to 14% of all zygomatic complex fractures. Bilateral isolated zygomatic arch fractures, which are defined as fractures of both zygomatic arches without any other facial fracture, are extremely rare. In this case report, we present a rare case of this facial fracture pattern.
Resumo:
Introduction. - Le TBS ou Score Trabéculaire Osseux (TBS, Med- Imaps, France) est un index d'architecture osseuse apportant des informations indépendantes de la densité minérale osseuse (DMO), et calculé par la quantification des variations locales des niveaux de gris à partir d'examen de densitométrie (DXA) lombaire. Dans des études antérieures prospectives et cas-témoins, cet index a été considéré comme associé aux fractures. Nous avons comparé les effets du ranélate de strontium (RanSr) et de l'alendronate (ALN) sur l'architecture vertébrale à l'aide du TBS, chez des femmes ostéoporotiques ménopausées. Patients et méthodes. - Une analyse post hoc a été réalisée sur des DXA (Hologic and GE Lunar Devices) de 79 des 189 femmes incluses dans une étude en double aveugle et double placebo et réparties de façon randomisée entre un groupe à 2 g/jour de RanSr et un groupe à 70 mg/semaine d'ALN pendant 2 ans. Les paramètres de TBS ont été évalués en aveugle par TBS iNsight (v1,9) au niveau vertébral après 12 et 24 mois de traitement. Nous avons appliqué les règles de l'ISCD (International Society for Clinical Densitometry) pour chaque exclusion de vertèbre, de façon indépendante respectivement pour la DMO et le TBS. Des doubles mesures ayant été réalisées initialement, la reproductibilité est exprimée en % CV. Résultats. - Les caractéristiques initiales (moyenne ± DS) étaient identiques entre les groupes en termes d'âge, 69,2 ± 4,4 ans ; d'IMC, 23,8 ± 4,4 kg/m2 ; de T-score L1-L4, - 2,9 ± 0,9 et de TBS, 1,230 ± 0,09. Comme prévu, le coefficient de détermination entre la DMO et le TBS au niveau du rachis était très basse r2 = 0,12. Les reproductibilités brutes étaient respectivement de 1,1 et 1,6 % pour la DMO et le TBS au niveau vertébral. Après 1 et 2 ans, la DMO en L1-L4 a augmenté de façon significative de respectivement 5,6 % et 9 % dans le groupe RanSr et de respectivement 5,2 % et 7,6 % dans le groupe ALN. De même, le TBS au niveau vertébral a augmenté respectivement de 2,3 % (p < 0,001) et de 3,1 % (p < 0,001) dans le groupe RanSr et de 0,5 % (NS) et de 1 % (NS) dans le groupe ALN avec une différence entre groupe significative en faveur du RanSr (p = 0,04 et p = 0,03). Il n'y avait aucune corrélation entre la différence de DMO et de TBS à 1 ou 2 ans. Les deux traitements étaient bien tolérés. Discussion. - Ces résultats sur le TBS confortent des études précédentes qui sont en faveur de l'effet bénéfique du RanSr sur l'architecture osseuse. Conclusion. - Le ranélate de strontium a des effets plus importants que l'alendronate sur le score trabéculaire osseux, indice d'architecture osseuse au niveau vertébral, chez les femmes ayant une ostéoporose post-ménopausique, après 2 ans de traitement.
Resumo:
Les fractures du condyle externe de l'enfant sont un traumatisme relativement fréquent qui survient le plus souvent chez l'enfant entre 5 et 15 ans. Elles sont classées en 3 grades : le grade 1 sans déplacement qui peuvent être traitées conservativement et les grades 2 (déplacées) et 3 (disloquées) qui nécessitent une prise en charge chirurgicale par réduction ouverte et embrochage. Le traitement traditionnel de ces fractures consistent en la mise en place de broches/vis métalliques qui doivent être retirées quelques semaines plus tard lors d'une seconde intervention. Depuis les années 90, des matériaux bio-résorbables à base d'acide polyglycoliques sont apparus en chirurgie orthopédique et traumatologique. En raison de la survenue de complications telles que réactions inflammatoires, formation de séromes ou ostéolyse, l'utilisation du matériel conventionnel a été préférée. Cependant, depuis quelques années, de nouveaux matériaux en acide polylactique sont apparus sur le marché. La période de résorption étant beaucoup plus lente, ces matériaux induisent des réactions beaucoup plus faibles, sans conséquences cliniques relevées jusqu'à présent. Chez l'adulte, de récentes études ont prouvés l'efficacité et l'absence d'effets secondaires liés à ces matériaux. Par contre, chez l'enfant, peu d'études à moyen terme ont été réalisées et l'impact sur l'os en croissance est peu connu, même si pour l'heure aucune conséquence clinique n'a été relevée. Dans le cadre de notre étude, nous avons comparé 2 groupes d'enfants traités pour des fractures du condyle externe du coude. Le premier groupe traité par du matériel conventionnel et le second par matériel résorbable. Les enfants ont tous étés suivis de manière très étroite durant la première année et la récupération clinique est similaire pour les 2 groupes. A 4 ans du traumatisme, les résultats fonctionnels sont identiques pour les 2 groupes et aucune complication liée au matériel résorbable n'a été mise en évidence. Par ailleurs, à 1 et 4 ans, les clichés radiologiques montrent l'absence de lésions liées au matériel résorbable. En conclusion, dans le cadre de notre travail nous avons pu montrer l'efficacité des matériaux résorbables dans la prise en charge des fractures du condyle externe du coude chez l'enfant. Ces matériaux permettent d'optimiser la prise en charge de ce type de fracture en prévenant un risque opératoire et anesthésique liés à une seconde intervention nécessaire au retrait du matériel d'ostéosynthèse conventionnel. Par ailleurs le coût lié à la prise en charge globale de ce type de fracture est moindre lors de l'utilisation de matériel résorbable.
Resumo:
Hormone replacement therapy (HRT) is an established approach for the treatment and the prevention of osteoporosis. Many studies with bone mineral density as primary outcome have shown significant efficacy. Observational studies have indicated a significant reduction of hip fracture risk in cohorts of women who maintained HRT therapy. The Women's Health Initiative is the first prospective randomised controlled study which showed a positive effect of HRT in terms of reduction of vertebral and hip fractures risk. Unfortunately, this study has been interrupted after 5.2 years because of the unsupportable increase of risk of cardiovascular disease and breast cancer. Compliance with HRT, however, is typically poor because of the potential side effects and possible increased risk of breast or endometrial cancer. Nevertheless, there is now evidence that lower doses of estrogens in elderly women may prevent bone loss while minimizing the side effects seen with higher doses. Combination therapies using low doses estrogen should probably be reserved for patients who continue to fracture on single therapy. Selective estrogen receptor modulators (SERMs) are very interesting drugs. The goal of these agents is to maximize the beneficial effect of estrogen on bone and to minimize or antagonize the deleterious effects on the breast and endometrium. Raloxifene, approved for the prevention and the treatment of osteoporosis, has been shown to reduce the risks of vertebral fracture in large clinical trials. However, they don't reduce non vertebral fractures. Tibolone is a synthetic steroid that increased bone mineral density at lumbar spine and femoral neck. But no trial has been performed with fractures as end point.
Resumo:
Vertebroplasty and kyphoplasty have been reported to alter the mechanical behavior of the treated and adjacent-level segments, and have been suggested to increase the risk for adjacent-level fractures. The intervertebral disc (IVD) plays an important role in the mechanical behavior of vertebral motion segments. Comparisons between normal and degenerative IVD motion segments following cement augmentation have yet to be reported. A microstructural finite element model of a degenerative IVD motion segment was constructed from micro-CT images. Microdamage within the vertebral body trabecular structure was used to simulate a slightly (I = 83.5% of intact stiffness), moderately (II = 57.8% of intact stiffness), and severely (III = 16.0% of intact stiffness) damaged motion segment. Six variable geometry single-segment cement repair strategies (models A-F) were studied at each damage level (I-III). IVD and bone stresses, and motion segment stiffness, were compared with the intact and baseline damage models (untreated), as well as, previous findings using normal IVD models with the same repair strategies. Overall, small differences were observed in motion segment stiffness and average stresses between the degenerative and normal disc repair models. We did however observe a reduction in endplate bulge and a redistribution in the microstructural tissue level stresses across both endplates and in the treated segment following early stage IVD degeneration. The cement augmentation strategy placing bone cement along the periphery of the vertebra (model E) proved to be the most advantageous in treating the degenerative IVD models by showing larger reductions in the average bone stresses (vertebral and endplate) as compared to the normal IVD models. Furthermore, only this repair strategy, and the complete cement fill strategy (model F), were able to restore the slightly damaged (I) motion segment stiffness above pre-damaged (intact) levels. Early stage IVD degeneration does not have an appreciable effect in motion segment stiffness and average stresses in the treated and adjacent-level segments following vertebroplasty and kyphoplasty. Placing bone cement in the periphery of the damaged vertebra in a degenerative IVD motion segment, minimizes load transfer, and may reduce the likelihood of adjacent-level fractures.
Resumo:
On 1 January 2012 Swiss Diagnosis Related Groups (DRG), a new uniform payment system for in-patients was introduced in Switzerland with the intention to replace a "cost-based" with a "case-based" reimbursement system to increase efficiency. With the introduction of the new payment system we aim to answer questions raised regarding length of stay as well as patients' outcome and satisfaction. This is a prospective, two-centre observational cohort study with data from University Hospital Basel and the Cantonal Hospital Aarau, Switzerland, from January to June 2011 and 2012, respectively. Consecutive in-patients with the main diagnosis of either community-acquired pneumonia, exacerbation of COPD, acute heart failure or hip fracture were included. A questionnaire survey was sent out after discharge investigating changes before and after SwissDRG implementation. Our primary endpoint was LOS. Of 1,983 eligible patients 841 returned the questionnaire and were included into the analysis (429 in 2011, 412 in 2012). The median age was 76.7 years (50.8% male). Patients in the two years were well balanced in regard to main diagnoses and co-morbidities. Mean LOS in the overall patient population was 10.0 days and comparable between the 2011 cohort and the 2012 cohort (9.7 vs 10.3; p = 0.43). Overall satisfaction with care changed only slightly after introduction of SwissDRG and remained high (89.0% vs 87.8%; p = 0.429). Investigating the influence of the implementation of SwissDRG in 2012 regarding LOS patients' outcome and satisfaction, we found no significant changes. However, we observed some noteworthy trends, which should be monitored closely.
Resumo:
Introduction. - L'ostéoporose est caractérisée par une diminution de la DMO et une altération de la microarchitecture (MA). La MA est évaluable en routine clinique par la mesure du Trabecular Bone Score (TBS), par simple ré-analyse de l'image lombaire de la DMO. Le TBS a démontré sa valeur diagnostique et pronostique, partiellement indépendante des FRC et le la DMO. Le but de la cohorte OsteoLaus est de combiner en routine clinique les FRC et les informations données par la DXA (DMO, TBS, VFA) et FRAX pour mieux identifier les femmes à risque de fracture. Matériels et Méthodes. - Dans la cohorte OsteoLaus (1 500 femmes, 50 à 80 ans, Lausanne, Suisse) les FRC, la DMO lombaire et de la hanche, l'IVA, le TBS et le FRAX sont relevés. La sensibilité et la spécificité des différents outils pour prédire les fractures vertébrales (FxV) de grade 2/3 ont été calculées. Résultats. - Nous avons inclus 451 femmes : âge 67,4 ± 6,7 ans, IMC 26,1 ± 4,6, DMO lombaire 0,943 ± 0,168 (T-score -1,4 SD), TBS 1,271 ± 0,103. La corrélation entre DMO et TBS est faible (r2 = 0,16). La prévalence des FxV 2/3 est de 9,3 %. Conclusion. - L'IMC a un mauvais pouvoir discriminant dans notre cohorte. Ces résultats préliminaires confirment l'indépendance partielle entre le TBS et la DMO. Une approche combinant TBS et FRAX semble être le meilleur compromis en termes de sensibilité/spécificité pour identifier les femmes avec une FxV 2/3 prévalente qui aurait pu être mal classifiée par la DMO ou le TBS ou le FRAX seuls.
Resumo:
L'utilisation efficace des systèmes géothermaux, la séquestration du CO2 pour limiter le changement climatique et la prévention de l'intrusion d'eau salée dans les aquifères costaux ne sont que quelques exemples qui démontrent notre besoin en technologies nouvelles pour suivre l'évolution des processus souterrains à partir de la surface. Un défi majeur est d'assurer la caractérisation et l'optimisation des performances de ces technologies à différentes échelles spatiales et temporelles. Les méthodes électromagnétiques (EM) d'ondes planes sont sensibles à la conductivité électrique du sous-sol et, par conséquent, à la conductivité électrique des fluides saturant la roche, à la présence de fractures connectées, à la température et aux matériaux géologiques. Ces méthodes sont régies par des équations valides sur de larges gammes de fréquences, permettant détudier de manières analogues des processus allant de quelques mètres sous la surface jusqu'à plusieurs kilomètres de profondeur. Néanmoins, ces méthodes sont soumises à une perte de résolution avec la profondeur à cause des propriétés diffusives du champ électromagnétique. Pour cette raison, l'estimation des modèles du sous-sol par ces méthodes doit prendre en compte des informations a priori afin de contraindre les modèles autant que possible et de permettre la quantification des incertitudes de ces modèles de façon appropriée. Dans la présente thèse, je développe des approches permettant la caractérisation statique et dynamique du sous-sol à l'aide d'ondes EM planes. Dans une première partie, je présente une approche déterministe permettant de réaliser des inversions répétées dans le temps (time-lapse) de données d'ondes EM planes en deux dimensions. Cette stratégie est basée sur l'incorporation dans l'algorithme d'informations a priori en fonction des changements du modèle de conductivité électrique attendus. Ceci est réalisé en intégrant une régularisation stochastique et des contraintes flexibles par rapport à la gamme des changements attendus en utilisant les multiplicateurs de Lagrange. J'utilise des normes différentes de la norme l2 pour contraindre la structure du modèle et obtenir des transitions abruptes entre les régions du model qui subissent des changements dans le temps et celles qui n'en subissent pas. Aussi, j'incorpore une stratégie afin d'éliminer les erreurs systématiques de données time-lapse. Ce travail a mis en évidence l'amélioration de la caractérisation des changements temporels par rapport aux approches classiques qui réalisent des inversions indépendantes à chaque pas de temps et comparent les modèles. Dans la seconde partie de cette thèse, j'adopte un formalisme bayésien et je teste la possibilité de quantifier les incertitudes sur les paramètres du modèle dans l'inversion d'ondes EM planes. Pour ce faire, je présente une stratégie d'inversion probabiliste basée sur des pixels à deux dimensions pour des inversions de données d'ondes EM planes et de tomographies de résistivité électrique (ERT) séparées et jointes. Je compare les incertitudes des paramètres du modèle en considérant différents types d'information a priori sur la structure du modèle et différentes fonctions de vraisemblance pour décrire les erreurs sur les données. Les résultats indiquent que la régularisation du modèle est nécessaire lorsqu'on a à faire à un large nombre de paramètres car cela permet d'accélérer la convergence des chaînes et d'obtenir des modèles plus réalistes. Cependent, ces contraintes mènent à des incertitudes d'estimations plus faibles, ce qui implique des distributions a posteriori qui ne contiennent pas le vrai modèledans les régions ou` la méthode présente une sensibilité limitée. Cette situation peut être améliorée en combinant des méthodes d'ondes EM planes avec d'autres méthodes complémentaires telles que l'ERT. De plus, je montre que le poids de régularisation des paramètres et l'écart-type des erreurs sur les données peuvent être retrouvés par une inversion probabiliste. Finalement, j'évalue la possibilité de caractériser une distribution tridimensionnelle d'un panache de traceur salin injecté dans le sous-sol en réalisant une inversion probabiliste time-lapse tridimensionnelle d'ondes EM planes. Etant donné que les inversions probabilistes sont très coûteuses en temps de calcul lorsque l'espace des paramètres présente une grande dimension, je propose une stratégie de réduction du modèle ou` les coefficients de décomposition des moments de Legendre du panache de traceur injecté ainsi que sa position sont estimés. Pour ce faire, un modèle de résistivité de base est nécessaire. Il peut être obtenu avant l'expérience time-lapse. Un test synthétique montre que la méthodologie marche bien quand le modèle de résistivité de base est caractérisé correctement. Cette méthodologie est aussi appliquée à un test de trac¸age par injection d'une solution saline et d'acides réalisé dans un système géothermal en Australie, puis comparée à une inversion time-lapse tridimensionnelle réalisée selon une approche déterministe. L'inversion probabiliste permet de mieux contraindre le panache du traceur salin gr^ace à la grande quantité d'informations a priori incluse dans l'algorithme. Néanmoins, les changements de conductivités nécessaires pour expliquer les changements observés dans les données sont plus grands que ce qu'expliquent notre connaissance actuelle des phénomenès physiques. Ce problème peut être lié à la qualité limitée du modèle de résistivité de base utilisé, indiquant ainsi que des efforts plus grands devront être fournis dans le futur pour obtenir des modèles de base de bonne qualité avant de réaliser des expériences dynamiques. Les études décrites dans cette thèse montrent que les méthodes d'ondes EM planes sont très utiles pour caractériser et suivre les variations temporelles du sous-sol sur de larges échelles. Les présentes approches améliorent l'évaluation des modèles obtenus, autant en termes d'incorporation d'informations a priori, qu'en termes de quantification d'incertitudes a posteriori. De plus, les stratégies développées peuvent être appliquées à d'autres méthodes géophysiques, et offrent une grande flexibilité pour l'incorporation d'informations additionnelles lorsqu'elles sont disponibles. -- The efficient use of geothermal systems, the sequestration of CO2 to mitigate climate change, and the prevention of seawater intrusion in coastal aquifers are only some examples that demonstrate the need for novel technologies to monitor subsurface processes from the surface. A main challenge is to assure optimal performance of such technologies at different temporal and spatial scales. Plane-wave electromagnetic (EM) methods are sensitive to subsurface electrical conductivity and consequently to fluid conductivity, fracture connectivity, temperature, and rock mineralogy. These methods have governing equations that are the same over a large range of frequencies, thus allowing to study in an analogous manner processes on scales ranging from few meters close to the surface down to several hundreds of kilometers depth. Unfortunately, they suffer from a significant resolution loss with depth due to the diffusive nature of the electromagnetic fields. Therefore, estimations of subsurface models that use these methods should incorporate a priori information to better constrain the models, and provide appropriate measures of model uncertainty. During my thesis, I have developed approaches to improve the static and dynamic characterization of the subsurface with plane-wave EM methods. In the first part of this thesis, I present a two-dimensional deterministic approach to perform time-lapse inversion of plane-wave EM data. The strategy is based on the incorporation of prior information into the inversion algorithm regarding the expected temporal changes in electrical conductivity. This is done by incorporating a flexible stochastic regularization and constraints regarding the expected ranges of the changes by using Lagrange multipliers. I use non-l2 norms to penalize the model update in order to obtain sharp transitions between regions that experience temporal changes and regions that do not. I also incorporate a time-lapse differencing strategy to remove systematic errors in the time-lapse inversion. This work presents improvements in the characterization of temporal changes with respect to the classical approach of performing separate inversions and computing differences between the models. In the second part of this thesis, I adopt a Bayesian framework and use Markov chain Monte Carlo (MCMC) simulations to quantify model parameter uncertainty in plane-wave EM inversion. For this purpose, I present a two-dimensional pixel-based probabilistic inversion strategy for separate and joint inversions of plane-wave EM and electrical resistivity tomography (ERT) data. I compare the uncertainties of the model parameters when considering different types of prior information on the model structure and different likelihood functions to describe the data errors. The results indicate that model regularization is necessary when dealing with a large number of model parameters because it helps to accelerate the convergence of the chains and leads to more realistic models. These constraints also lead to smaller uncertainty estimates, which imply posterior distributions that do not include the true underlying model in regions where the method has limited sensitivity. This situation can be improved by combining planewave EM methods with complimentary geophysical methods such as ERT. In addition, I show that an appropriate regularization weight and the standard deviation of the data errors can be retrieved by the MCMC inversion. Finally, I evaluate the possibility of characterizing the three-dimensional distribution of an injected water plume by performing three-dimensional time-lapse MCMC inversion of planewave EM data. Since MCMC inversion involves a significant computational burden in high parameter dimensions, I propose a model reduction strategy where the coefficients of a Legendre moment decomposition of the injected water plume and its location are estimated. For this purpose, a base resistivity model is needed which is obtained prior to the time-lapse experiment. A synthetic test shows that the methodology works well when the base resistivity model is correctly characterized. The methodology is also applied to an injection experiment performed in a geothermal system in Australia, and compared to a three-dimensional time-lapse inversion performed within a deterministic framework. The MCMC inversion better constrains the water plumes due to the larger amount of prior information that is included in the algorithm. The conductivity changes needed to explain the time-lapse data are much larger than what is physically possible based on present day understandings. This issue may be related to the base resistivity model used, therefore indicating that more efforts should be given to obtain high-quality base models prior to dynamic experiments. The studies described herein give clear evidence that plane-wave EM methods are useful to characterize and monitor the subsurface at a wide range of scales. The presented approaches contribute to an improved appraisal of the obtained models, both in terms of the incorporation of prior information in the algorithms and the posterior uncertainty quantification. In addition, the developed strategies can be applied to other geophysical methods, and offer great flexibility to incorporate additional information when available.
Resumo:
5 to 10% of all fractures present with a delayed union, whereas 1 to 5% progress to a nonunion, which can be defined as a fracture older than 6 months and lacks any potential to heal without any further intervention. Different fracture and patient related risk factors exist, and the management of a nonunion needs a thorough clinical, radiological and biological workup to classify them in one of the two main categories, the viable nonunions that need essentially more stability, usually by a more rigid fixation, and the non-viable nonunions that need essentially a biological stimulation by decortication and bone grafting. This treatment still remains the first choice with bony healing obtained in 85 to 95% of cases, but it also comes along with certain risks, and some valuable alternatives exist if chosen on the basis of rigid criteria.
Resumo:
The trabecular bone score (TBS) is a new parameter that is determined from gray-level analysis of dual-energy X-ray absorptiometry (DXA) images. It relies on the mean thickness and volume fraction of trabecular bone microarchitecture. This was a preliminary case-control study to evaluate the potential diagnostic value of TBS as a complement to bone mineral density (BMD), by comparing postmenopausal women with and without fractures. The sample consisted of 45 women with osteoporotic fractures (5 hip fractures, 20 vertebral fractures, and 20 other types of fracture) and 155 women without a fracture. Stratification was performed, taking into account each type of fracture (except hip), and women with and without fractures were matched for age and spine BMD. BMD and TBS were measured at the total spine. TBS measured at the total spine revealed a significant difference between the fracture and age- and spine BMD-matched nonfracture group, when considering all types of fractures and vertebral fractures. In these cases, the diagnostic value of the combination of BMD and TBS likely will be higher compared with that of BMD alone. TBS, as evaluated from standard DXA scans directly, potentially complements BMD in the detection of osteoporotic fractures. Prospective studies are necessary to fully evaluate the potential role of TBS as a complementary risk factor for fracture.
Resumo:
The morbidity of bone graft harvesting from the iliac crest has been widely discussed in the literature. For some authors, it is considered to be low and for others relatively high. We report on a case of a fracture of the iliac wing after graft harvesting from the anterior iliac crest despite good surgical technique. This complication is well known and most of these fractures heal uneventfully if treated conservatively. However, if anatomical and technical considerations are respected, the patient could be spared this inconvenience. Based on a literature review, we discuss the procedure's potential complications and how to avoid them in an update.