898 resultados para Force transducer
Resumo:
Glassy carbon electrodes (GCE) were modified with poly(glutamic acid) acid films prepared using three different procedures: glutamic acid monomer electropolymerization (MONO), evaporation of poly(glutamic acid) (PAG) and evaporation of a mixture of poly(glutamic acid)/glutaraldehyde (PAG/GLU). All three films showed good adherence to the electrode surface. The performance of the modified GCE was investigated by cyclic voltammetry and differential pulse voltammetry, and the films were characterized by atomic force microscopy (AFM) and electrochemical impedance spectroscopy (EIS). The three poly(glutamic acid) modified GCEs were tested using the electrochemical oxidation of ascorbic acid and a decrease of the overpotential and the improvement of the oxidation peak current was observed. The PAG modified electrode surfaces gave the best results. AFM morphological images showed a polymeric network film formed by well-defined nanofibres that may undergo extensive swelling in solution, allowing an easier electron transfer and higher oxidation peaks. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
We present a new strategy for the label-free electrochemical detection of DNA hybridization for detecting hepatitis C virus based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes. Synthetic single-stranded 18-mer HCV genotype-1-specific probe DNA has been immobilized at a 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole film established by electropolymerization at the previously formed polypyrrole layer. HCV DNA sequences (244-mer) resulting from the reverse transcriptase-linked polymerase chain reaction amplification of the original viral RNA were monitored by affecting the ion-exchange properties of the polypyrrole film. The performance of this miniaturized DNA sensor system was studied in respect to selectivity, sensitivity, and reproducibility. The limit of detection was determined at 1.82 x 10(-21) mol L-1. Control experiments were performed with cDNA from HCV genotypes 2a/c, 2b, and 3 and did not show any unspecific binding. Additionally, the influence of the spacer length of 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole on the behavior of the DNA sensor was investigated. This biosensing scheme was finally extended to the electrochemical detection of DNA at submicrometer-sized DNA biosensors integrated into bifunctional atomic force scanning electrochemical microscopy probes. The 18-mer DNA target was again monitored by following the ion-exchange properties of the polypyrrole film. Control experiments were performed with 12-base pair mismatched sequences.
Resumo:
The influence of afterload on the rate of force generation by the myocardium was investigated using two types of preparations: the in situ dog heart (dP/dt) and isolated papillary muscle of rats (dT/dt). Thirteen anesthetized, mechanically ventilated and thoracotomized dogs were submitted to pharmacological autonomic blockade (3.0 mg/kg oxprenolol plus 0.5 mg/kg atropine). A reservoir connected to the left atrium permitted the control of left ventricular end-diastolic pressure (LVEDP). A mechanical constriction of the descending thoracic aorta allowed to increase the systolic pressure in two steps of 20 mmHg (conditions H1 and H2) above control values (condition C). After arterial pressure elevations (systolic pressure C: 119 ± 8.1; H1: 142 ± 7.9; H2 166 ± 7.7 mmHg; P<0.01), there were no significant differences in heart rate (C: 125 ± 13.9; H1: 125 ± 13.5; H2: 123 ± 14.1 bpm; P>0.05) or LVEDP (C: 6.2 ± 2.48; H1: 6.3 ± 2.43; H2: 6.1 ± 2.51 mmHg; P>0.05). The values of dP/dt did not change after each elevation of arterial pressure (C: 3,068 ± 1,057; H1: 3,112 ± 996; H2: 3,086 ± 980 mmHg/s; P>0.05). In isolated rat papillary muscle, an afterload corresponding to 50% and 75% of the maximal developed tension did not alter the values of the maximum rate of tension development (100%: 78 ± 13; 75%: 80 ± 13; 50%: 79 ± 11 g mm-2 s-1, P>0.05). The results show that the rise in afterload per se does not cause changes in dP/dt or dT/dt
A utilização de diferentes configurações de molas T para a obtenção de sistemas de forças otimizados
Resumo:
OBJETIVO: determinar as características mecânicas de molas T e T com helicóides, quando da incorporação de variações na liga metálica (aço inoxidável e beta-titânio), na intensidade de dobras de pré-ativação (0º e 40º/180º) e na secção transversal do fio utilizado para a construção destas molas (0,017 x 0,025 e 0,019 x 0,025). METODOLOGIA: foram submetidas ao ensaio mecânico 80 molas para fechamento de espaços, sendo estas centralizadas em um espaço de 21mm. As magnitudes de força horizontal, proporção momento/força e relação carga/deflexão produzidas pelos corpos de prova foram quantificadas utilizando-se um transdutor de momentos acoplado ao módulo indicador digital para extensiometria e adaptado a uma máquina universal de ensaios Instron. As molas foram submetidas a uma ativação total de 5mm, sendo registrados os valores a cada 1mm de ativação. No tratamento estatístico dos dados obtidos, foi realizada a análise de variância, sendo esta complementada pelo teste de comparações múltiplas de Tukey, considerando o nível de significância de 5%. RESULTADOS E CONCLUSÕES: os resultados demonstraram que, de maneira geral, as molas T com helicóides produziram menores magnitudes de força horizontal e relação carga/deflexão do que as molas T. Na presença de pré-ativação, as molas produziram altas proporções momento/força, enquanto, na ausência de dobras de pré-ativação, as mesmas geraram baixas proporções momento/força. Dentre todas as variáveis analisadas, aquela que apresentou uma maior influência na força horizontal e na relação carga/deflexão produzidas pelas molas foi a liga metálica. Já a proporção momento/força mostrou ser influenciada em maior grau pela pré-ativação das molas de fechamento.
Resumo:
We describe a numerical procedure for plotting the force-versus-time curves in elastic collisions between identical conducting balls. A system of parametric equations relating the force and the time to a dimensionless parameter is derived from the assumption of a force compatible with Hertz's theory of collision. A simple experimental arrangement consisting of a mechanical system of colliding balls and an electrical circuit containing a crystal oscillator and an electronic counter is used to measure the collision time as a function of the energy of impact. From the data we can determine the relevant parameters. The calculated results agree very well with the expected values and are consistent with the assumption that the collisions are elastic. (C) 2006 American Association of Physics Teachers.
Resumo:
In this work the problem of a spacecraft bi-impulsive transfer between two given non coplanar elliptical orbits, with minimum fuel consumption, is solved considering a non-Keplerian force field (the perturbing forces include Earth gravity harmonics and atmospheric drag). The problem is transformed in the Two Point Boundary Value Problem. It is developed and implemented a new algorithm, that uses the analytical expressions developed here. A dynamics that considered a Keplerian force field was used to produce an initial guess to solve the Two Point Boundary Value Problem. Several simulations were performed to observe the spacecraft orbital behaviour by different kind of perturbations and constraints, on a fuel consumption optimization point of view. (C) 2002 COSPAR. Published by Elsevier B.V. Ltd. All rights reserved.
Resumo:
The microbiological leaching of chalcopyrite (CuFeS2) is of great interest because of its potential application to many CuFeS2-rich ore materials. However, the efficiency of the microbiological process is very limited because this mineral is one of the most refractory to bacterial attack. Knowledge of bacterial role during chalcopyrite oxidation is very important in order to improve the efficiency of bioleaching operation. The oxidative dissolution of a massive chalcopyrite electrode by Acidithiobacillus ferrooxidans was evaluated by electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM). A massive chalcopyrite electrode was utilized in a Tait-type electrochemical cell in acid medium for different immersion times in the presence or absence of bacterium. The differences observed in the impedance diagrams were correlated with the adhesion process of bacteria on the mineral surface. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Thin films of BaBi2Ta2O9 (BBT) composition were prepared through the metal organic decomposition method. The crystallinity, phase formation, crystallite size and morphology of the thin films were measured as a function of the type of substrate, stoichiometry of solution and process variables such as thickness and temperature. The thin films were investigated by grazing incidence X-ray diffractometry and atomic force microscopy (AFM) techniques. For the sample without excess of bismuth, diffraction peaks other than that of the BBT phase were observed. A well crystallized BBT single phase was observed for films prepared from a solution with 10% excess of bismuth, deposited on Si/Pt substrate, with a thickness up to 150 nm and sintered at temperatures of 700 degreesC. The thin BBT phase films heat-treated at 600 degreesC presented a diffraction pattern characteristic of samples with lower degree of crystallinity whereas for the thin films heat-treated at 800 degreesC, we observed the presence of other phases than the BBT. For the thin film deposited on the Sin+ substrate, we observe that the peaks corresponding to the BBT phase are broader than that observed on the samples deposited on the Pt and Si/Pt substrates. No variation of average crystallite size was observed as the excess of Bi increased from 10 to 20%. AFM images for the samples showed that the increasing the amount of bismuth promotes grain growth. The average surface roughness measured was in the range of 16-22 nm showing that the bismuth amount had no or little effect on the roughness of films. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
The production of metallic junctions employing elastomers is an unconventional technique that has been in development in the last 20 years. The forming process gets successfull just if a simultaneous compression between the elastomers and the tube takes place. Exact solutions for problems involving forming with elastomers are quite difficult to determine. However, the upper-bound theory can be used in order to predict the necessary load for junctions forming. Thus, it is necessary to develop a model capable to provide an estimate of the total forming force, which is useful to set-up tools and equipments required for the process. In this work, Von Mises, Hill's 1948 and Hill's 1979 associated yielding theories, and the Hosford's theory (1979) as well, were used in order to study the anisotropic behaviour on total forming force of junctions using elastomers, insuring the functionality of the proposed model. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
This study evaluated retention force and fatigue resistance of two overdenture attachment systems. Twenty samples (O-ring and Bar-Clip) from two manufacturers (Conexao Sistemas de Protese and Lifecore Biomedical) were prepared and divided into four groups: (i) Conexao/O-ring; (ii) Conexao/Bar-Clip; (iii) Lifecore/O-ring and (iv) Lifecore/Bar-Clip, with five samples in each group. They were submitted to mechanical fatigue test using a servohydraulic machine performing 5500 cycles of insertion and removal (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained three times (0, 3000 and after 5500 cycles) simulating the clinical service, using a tensile strength at 1 mm min(-1) and load cell of 1 kN. Data were analysed with analysis of variance and Tukey's test at 5% level. Results showed that Conexao/Bar-Clip specimens had significantly higher retention values than Lifecore/Bar-Clip (44.61 and 18.44 N, respectively), Conexao/O-ring specimens had significantly lower values than Lifecore/O-ring (13.91 and 19.75 N, respectively). Conexao/Bar-Clip values were always significantly higher than those of Conexao/O-ring group (44.61 and 13.91 N, respectively). Lifecore (O-ring and Bar-Clip) presented similar values (19.75 and 18.44 N, respectively). The systems evaluated showed satisfactory retention force values, before and after fatigue testing. Conexao/Bar-Clip specimens presented the highest values. A 5-year simulation of insertion and removal did not decrease retention values or fracture components.
Resumo:
This paper discuss the qualitative use of electrostatic force microscopy to study the grain boundary active potential barrier present in dense SnO2-based polycrystalline semiconductors. The effect of heat treatment under rich- and poor-oxygen atmospheres was evaluated while especially considering the number of active barriers at grain boundary regions. The results show that the number of active barriers decrease after heat treatment in an oxygen-poor atmosphere and increase after heat treatment in oxygen-rich atmospheres. The observed effect was explained by considering the presence of oxidized transition metal elements segregated at grain boundary regions which leads to the p-type character of this region, in agreement with the atomic barrier formation mechanism in metal oxide varistor systems.
Resumo:
This paper describes a technique for extending the force range of thin conductive polymer force sensors used for measuring contact force. These sensors are conventionally used for measuring force by changing electrical resistance when they are compressed. The new method involves measuring change in electrical resistance when the flexible sensor, which is sensitive to both compression and bending, is sandwiched between two layers of spring steel, and the structure is supported on a thin metal ring. When external force is applied, the stiffened sensor inside the spring steel is deformed within the annular center of the ring, causing the sensor to bend in proportion to the applied force. This method effectively increases the usable force range, while adding little in the way of thickness and weight. Average error for loads between 10 N and 100 N was 2.2 N (SD = 1.7) for a conventional conductive polymer sensor, and 0.9 N (SD = 0.4) using the new approach. Although this method permits measurement of greater loads with an error less than 1 N, it is limited since the modified sensor is insensitive to loads less than 5 N. These modified sensors are nevertheless useful for directly measuring normal force applied against handles and tools and other situations involving forceful manual work activities, such as grasp, push, pull, or press that could not otherwise be measured in actual work situations.