993 resultados para Flame throwers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new, versatile, and simple method for quantitative analysis of zinc, copper, lead, and cadmium in fuel ethanol by anodic stripping voltammetry is described. These metals can be quantified by direct dissolution of fuel ethanol in water and subsequent voltammetric measurement after the accumulation step. A maximum limit of 20% (v/v) ethanol in water solution was obtained for voltammetric measurements without loss of sensitivity for metal species. Chemical and operational optimum conditions were analyzed in this study; the values obtained were pH 2.9, a 4.7-mum thickness mercury film, a 1,000-rpm rotation frequency of the working electrode, and a 600-s pre-concentration time. Voltammetric measurements were obtained using linear scan (LSV), differential pulse (DPV), and square wave (SWV) modes and detection limits were in the range 10(-9)-10(-8) mol L-1 for these metal species. The proposed method was compared with a traditional analytical technique, flame atomic absorption spectrometry (FAAS), for quantification of these metal species in commercial fuel ethanol samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clove basil (Ocimum gratissimum) extracts were obtained with supercritical CO2. Clove basil was cultivated using 0, 4, 8 and 12 kg/m(2) of organic fertilizer and was harvested in four seasons: winter, spring, summer and autumn, in the Southern Hemisphere. The extracts' global yields were determined at 40C and 150 bar for samples from all cultivation conditions and harvesting seasons. For selected samples, the extracts' global yields at 40C were determined for pressures of 100, 150, 200, 250 and 300 bar. The extracts were analyzed by gas chromatography-flame ionization detector. Antioxidant activity (AA) was assessed using the coupled reaction of beta-caroteneand linolenic acid. The extracts' global yields varied from 0.91 to 1.79% (dry basis), and the AAs varied from 62 to 84% compared with the control beta-carotene. Eugenol and beta-selinene were the major compounds. The relative proportion of eugenol varied from 35 to 60%, while the content of beta-selinene remained approximately constant (11.5-14.1%, area). The other substances quantified in the extracts were 1,8 cineole, trans-caryophyllene and alpha-selinene.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present research was to study the degradation and the persistence of phenthoate (Elsan 50 CE) residues in tomato fruits. The experiment was set in a tomato field located in Mombuca, State of São Paulo, Brazil, after 45 days from seedlings transplantation. Dosages of 600 (A), 800 (B), 1200 (C) and 1600 g a.i./ha (D) were sprayed at the beginning of the ripening period of fruits. Samples of 15 fruits each were collected 1, 4, 10, 20 and 40 days after products spraying. The utilized procedure consisted of extraction with acetone and purification by partition with dichloromethane. The purified extract was concentrated and injected into a gas chromatograph equipped with alkaly flame ionization detector (AFID). The limits of detection were of 0,01 ppm for this product. The recovery percentage from fortified samples varied from 60 to 81%. The degradation and the persistence half-lives were 1 to 2 and 3 to 6 days for phenthoate, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A fast and efficient procedure was elaborated to identify the alkaloid constituents from Tabernaemontana hilariana (Apocynaceae). The strategy based on fractioning of the crude alkaloid fraction in small silica cartridges followed by thin-layer chromatography (TLC), capillary gas chromatography-flame ionization detection as well as high-resolution gas chromatography-mass spectrometry afforded voacangine, coronaridine, ibogamine, voacangine pseudoindoxyl, voacangine hydroxyindolenine, 3-hydroxycoronaridine and 3-(2-oxopropyl)coronaridine. (C) 1997 Elsevier B.V. B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A total of 2400 samples of commercial Brazilian C gasoline were collected over a 6-month period from different gas stations in the São Paulo state, Brazil, and analysed with respect to 12 physicochemical parameters according to regulation 309 of the Brazilian Government Petroleum, Natural Gas and Biofuels Agency (ANP). The percentages (v/v) of hydrocarbons (olefins, aromatics and saturated) were also determined. Hierarchical cluster analysis (HCA) was employed to select 150 representative samples that exhibited least similarity on the basis of their physicochemical parameters and hydrocarbon compositions. The chromatographic profiles of the selected samples were measured by gas chromatography with flame ionisation detection and analysed using soft independent modelling of class analogy (SIMCA) method in order to create a classification scheme to identify conform gasolines according to ANP 309 regulation. Following the optimisation of the SIMCA algorithm, it was possible to classify correctly 96% of the commercial gasoline samples present in the training set of 100. In order to check the quality of the model, an external group of 50 gasoline samples (the prediction set) were analysed and the developed SIMCA model classified 94% of these correctly. The developed chemometric method is recommended for screening commercial gasoline quality and detection of potential adulteration. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The efficiency of two methods for determining 3-hydroxybutyrate and 3-hydroxyvalerate content in the biopolymer (poly(3-hydroxybutyrate-co-3-hydroxyvalerate) has been evaluated. Both methods are based on (a) the hydrolysis of polymers, (b) the esterification with methyl (method A) and isoamilic alcohol (method B) and (c) analysis of the esters by gas chromatography using flame ionization detection (GC-FID). After optimization of the analytical conditions, the main validation parameters (linearity, quantification limit, detection limit, recovery, sensitivity and precision) were determined showing that both analytical procedures can be applied to control the process of poly(3-hydroxybutyrate) production. However, method B gives better analytical results than method A and has the advantage of not using chlorinated solvents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A comparative study is reported between C-18 bonded silica gel and powdered polyethylene (PE) as sorbent for Cd, Cu, and Pb determination using ammonium diethyldithiophosphate (ADTP) as the complexing agent in a flow injection system. The complexes were formed in 0.14 mol L-1 HNO3 and processed in a simple flow system comprising a peristaltic pump, a manual injector-commutator, and a sorbent-packed minicolumn. Ethanol was selected as the eluent and analytes in the eluate were determined by flame atomic absorption spectrometry. The optimum concentration of the complexing agent was 0.1% (m/v) ADTP for Cu and Pb determination using either C-18 or PE, and 0.25% (m/v) ADTP for Cd determination using PE. The sample loading flow rates were 5.0, 3.6, and 3.0 mL min(-1) for Cu, Pb, and Cd, respectively. The best elution flow rate was 6.5 mL min(-1). For a 60-sec preconcentration time, the sampling rate was 40 h(-1) and the enrichment factors of 33, 36, and 11 times (C-18) or 18, 22, and 23 times (PE) were obtained for Cu, Pb, and Cd, respectively. The limits of detection (LOD) were 1.6 mug L-1 Cu, 11 mug L-1 Pb, and 2.0 mug L-1 Cd using C-18 or 2.9 mug L-1 Cu, 19 mug L-1 Pb, and 1.0 mug L-1 Cd using PE, respectively. The relative standard deviations (n = 12) were typically <2%, <2%, and <6% for Cd, Cu, and Pb, respectively. The recoveries of Cd, Cu, and Pb added to wine samples varied from 96-99%, 97-102%, and 90-99%, respectively, using C-18 or PE. Accuracy was checked for Cd, Cu, and Pb determination in six wine samples digested by block digestor and open-vessel microwave-assisted digestion systems. The results revealed that C-18 was more efficient for Cu and Pb determination, while PE was the best sorbent for Cd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study the levels of Cu, Fe, Pb and Zn, determined in hair of healthy children (25-85 months), living at Araraquara (São Paulo, Brasil) are reported. Analytical determinations were carried out by using atomic absorption spectrometry employing an air acetylene flame. The results obtained are discussed with regard to effect of sex and age, as well compared with others analogous studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the synthesis and characterization of 5-amino-1,3,4-thiadiazole-2-thiol modified silica gel (SiATT), and the results of a study of the adsorption and preconcentration (in batch, and in flow using a column technique) of Cd(II), Co(II), Cu(II), Fe(III), Ni(II), Pb(II) and Zn(II) in ethanol medium. The adsorption capacities for each metal ion were (in mmol g -1): Cd(II) = 0.11, Co(II) = 0.10, Cu(II) = 0.20, Fe(III) = 0.20, Ni(II) = 0.16, Pb(II) = 0.08 and Zn(II) = 0.12. The results obtained in the flow experiments, showed a recovery of ca. 100% of the metal ions adsorbed in a column packed with 2 g of SiATT, using 5 mL of 2.0 mol L -1 HCl solution as eluent. The sorption-desorption of the metal ions made possible the development of a preconcentration method and quantification by Flame AAS of metal ions at trace level in fuel ethanol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of oxygen to enrich the combustion air can be an attractive technique to increase capacity of an incinerator originally designed to operate with air. If incinerator parameters such as operation temperature, turbulence level and residence time are fixed for a certain fuel supply rate, it is possible to increase the residue consumption rate using enriched air. This paper presents the thermal analysis for operation with enriched air of an aqueous residue experimental incinerator. The auxiliary fuel was diesel oil. The theoretical results showed that there is a considerable increase in the incineration ratio up to approximately 50 % of O 2 in the oxidiser. The tendency was confirmed experimentally. Thermal analysis was demonstrated to be an important tool to predict possible incinerator capacity increase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Methods were developed for the analysis of acetonitrile and its metabolite cyanide in the blood of rats exposed to acetonitrile. Acetonitrile was analyzed by the headspace technique coupled to gas chromatography with detection by flame ionization, and cyanide was analyzed by high-performance liquid chromatography with fluorescence detection (λ ex = 418 nm and λ em = 460 nm) after derivatization of the ion with naphthalene 2,3-dicarboxyaldehyde and taurine. The quantitation limits of the methods for the analysis of acetonitrile and cyanide were 4.875 μg/mL and 0.025 μg/mL, respectively. The coefficients of variation of 10% or less obtained for intra- and interassay precision indicate the precision of these analytical methods and the systematic errors, all less than 5%, indicate that the methods are quite accurate. The methods were applied to an experimental study after the animals received acetonitrile at the doses of 2 mmol/kg or 5 mmol/kg.