909 resultados para Fisioterapia Respiratoria
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper presents a proposal to redesign a physical therapy device for patients with quadriplegia, called parapodium. With the help of the Association of Parents and Exceptional Friends of Guaratinguetá, it was possible to know the currently used device and from this it was conceived changes, allowing the increase of freedom of its central portion, in the down and across positions with mechanical drive . This adaptation is to introduce improvements in the routine of physical therapy professionals and reduce ergonomic problems resulting from repetitive strain during the transfer of patients to the parapodium. In addition to providing greater security for patients who require the use of this equipment. The proposed device comprises: wheel, gearbox and brake systems used for actuation, allowing a degree of turning of the rear post, along an axis which is fixed to the gearbox and the rear structure that permits posterior movement. The mechanism allows the rear post rotate from 0 ° to 90 °. The estimated cost to make the proposal is lower than the marketed parapodiuns, reaching the device's functional expectations
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper presents a proposal to redesign a physical therapy device for patients with quadriplegia, called parapodium. With the help of the Association of Parents and Exceptional Friends of Guaratinguetá, it was possible to know the currently used device and from this it was conceived changes, allowing the increase of freedom of its central portion, in the down and across positions with mechanical drive . This adaptation is to introduce improvements in the routine of physical therapy professionals and reduce ergonomic problems resulting from repetitive strain during the transfer of patients to the parapodium. In addition to providing greater security for patients who require the use of this equipment. The proposed device comprises: wheel, gearbox and brake systems used for actuation, allowing a degree of turning of the rear post, along an axis which is fixed to the gearbox and the rear structure that permits posterior movement. The mechanism allows the rear post rotate from 0 ° to 90 °. The estimated cost to make the proposal is lower than the marketed parapodiuns, reaching the device's functional expectations
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background: Walking speed seems to be related to aerobic capacity, lower limb strength, and functional mobility, however it is not clear whether there is a direct relationship between improvement in muscle strength and gait performance in early postmenopausal women. Objective: To evaluate the effect of muscle strengthening exercises on the performance of the 6-minute walk test in women within 5 years of menopause. Methods: The women were randomized into control group (n=31), which performed no exercise, and exercise group (n=27), which performed muscle strengthening exercises. The exercises were performed twice a week for 3 months. The exercise protocol consisted of warm-up, stretching, and strengthening of the quadriceps, hamstring, calf, tibialis anterior, gluteus maximus, and abdominal muscles, followed by relaxation. Muscular strength training started with 60% of 1MR (2 series of 10-15 repetitions), reaching 85% until the end of the 3-month period (4 series of 6 repetitions each). Results: The between-group comparisons pre- and post-intervention did not show any difference in distance walked, heart rate or blood pressure (p>0.05), but showed differences in muscle strength post-intervention, with the exercise group showing greater strength (p<0.05). In the within-group comparison, there were differences in final heart rate and quadriceps and hamstring strength pre- and post-intervention in the exercise group (p<0.05). Conclusion: The results suggest that muscle strengthening of the lower limbs did not improve performance in the 6-minute walk test in this population of postmenopausal women. Trial registration ACTRN12609001053213.
Resumo:
Objective: To identify whether flight training activities cause postural changes in cadets and pilots of the Brazilian Air Force Academy (AFA). Methods: Eighty subjects were assessed through photographic images in anterior and right side views. Four groups of cadets (n=20 per group) divided according to the year since enlistment and a fifth group of fifteen pilots from the Air Demonstration Squadron (ADS) were included. Pictures were analyzed using the Postural Analysis Program (SAPO) and angles related to head vertical alignment (HVA), head horizontal alignment (HHA), acromion horizontal alignment (AHA) and anterior-superior iliac spine horizontal alignment (HAS) were plotted. Results: We did not find statistical significant differences in the angles: HVA, HHA and AHA. However, a significant difference was found for the HAS angle with pilots having lower values than cadets, suggesting greater postural stability for this variable in pilots. Conclusion: The horizontal alignment of the anterior-superior iliac spine was the only measure that showed significant difference in the comparison between pilots and cadets. The remaining alignments were not different, possibility because of the strict criteria used for admission of cadets at the AFA and the efficiency of the physical training that is performed periodically.
Resumo:
Background: The rapid shallow breathing index (RSBI) is the most widely used index within intensive care units as a predictor of the outcome of weaning, but differences in measurement techniques have generated doubts about its predictive value. Objective: To investigate the influence of low levels of pressure support (PS) on the RSBI value of ill patients. Method: Prospective study including 30 patients on mechanical ventilation (MV) for 72 hours or more, ready for extubation. Prior to extubation, the RSBI was measured with the patient connected to the ventilator (Drager (TM) Evita XL) and receiving pressure support ventilation (PSV) and 5 cmH(2)O of positive end expiratory pressure or PEEP (RSBI_MIN) and then disconnected from the VM and connected to a Wright spirometer in which respiratory rate and exhaled tidal volume were recorded for 1 min (RSBI_ESP). Patients were divided into groups according to the outcome: successful extubation group (SG) and failed extubation group (FG). Results: Of the 30 patients, 11 (37%) failed the extubation process. In the within-group comparison (RSBI_MIN versus RSBI_ESP), the values for RSBI_MIN were lower in both groups: SG (34.79 +/- 4.67 and 60.95 +/- 24.64) and FG (38.64 +/- 12.31 and 80.09 +/- 20.71; p<0.05). In the between-group comparison, there was no difference in RSBI_MIN (34.79 +/- 14.67 and 38.64 +/- 12.31), however RSBI_ESP was higher in patients with extubation failure: SG (60.95 +/- 24.64) and FG (80.09 +/- 20.71; p<0.05). Conclusion: In critically ill patients on MV for more than 72h, low levels of PS overestimate the RSBI, and the index needs to be measured with the patient breathing spontaneously without the aid of pressure support.
Resumo:
Background: Evidence of self-sustained muscle activation following a brief electrical stimulation has been reported in the literature for certain muscles. Objectives: This report shows that the foot muscle (Flexor Digitorum Brevis - FDB) shows a self-sustained increase in muscle activity during upright stance in some subjects following a train of stimuli to the tibial nerve. Methods: Healthy subjects were requested to stand upright and surface EMG electrodes were placed on the FDB, Soleus and Tibialis Anterior muscles. After background muscle activity (BGA) acquisition, a 50 Hz train of stimuli was applied to the tibial nerve at the popliteal fossa. The root mean square values (RMS) of the BGA and the post-stimulus muscle activation were computed. Results: There was a 13.8% average increase in the FDB muscle EMG amplitude with respect to BGA after the stimulation was turned off. The corresponding post-stimulus Soleus EMG activity decreased by an average of 9.2%. We hypothesize that the sustained contraction observed in the FDB following stimulus may be evidence of persistent inward currents (PIC) generated in FDB spinal motoneurons. The post-stimulus decrease in soleus activity may have occurred due to the action of inhibitory interneurons caused by the PICs, which were triggered by the stimulus train. Conclusions: These sustained post-stimulation changes in postural muscle activity, found in different levels in different subjects, may be part of a set of possible responses that contribute to overall postural control.
Resumo:
Background: In the literature, there are several experimental models that induce scoliosis in rats; however, they make use of drugs or invasive interventions to generate a scoliotic curve. Objectives: To design and apply a non-invasive immobilization model to induce scoliosis in rats. Methods: Four-week old male Wistar rats (85 +/- 3.3 g) were divided into two groups: control (CG) and scoliosis (SG). The animals in the SG were immobilized by two vests (scapular and pelvic) made from polyvinyl chloride (PVC) and externally attached to each other by a retainer that regulated the scoliosis angle for twelve weeks with left convexity. After immobilization, the abdominal, intercostal, paravertebral, and pectoral muscles were collected for chemical and metabolic analyses. Radiographic reports were performed every 30 days over a 16-week period. Results: The model was effective in the induction of scoliosis, even 30 days after immobilization, with a stable angle of 28 +/- 5 degrees. The chemical and metabolic analyses showed a decrease (p<0.05) in the glycogenic reserves and in the relationship between DNA and total protein reserves of all the muscles analyzed in the scoliosis group, being lower (p<0.05) in the convex side. The values for the Homeostatic Model Assessment of Insulin Resistance indicated a resistance condition to insulin (p<0.05) in the scoliosis group (0.66 +/- 0.03), when compared to the control group (0.81 +/- 0.02). Conclusions: The scoliosis curvature remained stable 30 days after immobilization. The chemical and metabolic analyses suggest changes in muscular homeostasis during the induced scoliosis process.
Resumo:
CONTEXTUALIZAÇÃO: A dor no ombro em profissionais de enfermagem pode acarretar limitação das atividades diárias e ocupacionais e interferir na qualidade de vida. OBJETIVO: Comparar o efeito da aplicação de dois programas fisioterapêuticos diferenciados pelos exercícios de propriocepção em trabalhadores de enfermagem com desordem do manguito rotador, segundo indicadores de qualidade de vida, satisfação no trabalho e intensidade da dor. MÉTODO: Trata-se de um estudo experimental, randomizado, prospectivo, comparativo, com análise quantitativa dos dados. A coleta de dados foi realizada no período de junho de 2010 a julho de 2011, por meio de um questionário sociodemográfico e profissional, questionário Western Ontario Rotador Cuff Index (WORC), Escala de Satisfação no Trabalho (Occupational Stress Indicator) e Escala Visual Numérica (EVN) para intensidade da dor. Após randomização, os sujeitos foram alocados em dois grupos. No Grupo 1 (controle), foram aplicados exercícios de alongamento, fortalecimento e crioterapia. No Grupo 2 (experimental), foram realizados os mesmos exercícios que no Grupo 1 acrescidos de exercícios proprioceptivos. Os dados foram analisados por meio do Statistical Package for the Social Science, versão 16.0 para Windows. RESULTADOS: Após os tratamentos fisioterapêuticos, houve melhora significativa da dor nos sujeitos dos dois grupos e da qualidade de vida nos trabalhadores do Grupo 2. Não houve alteração dos indicadores de satisfação no trabalho nos dois grupos. CONCLUSÕES: Os exercícios proprioceptivos foram importantes no tratamento dos distúrbios osteomusculares. No entanto, os resultados não permitiram inferir a melhor efetividade deles em relação ao outro tratamento, pois não houve diferença significativa entre os grupos. Ensaio clínico registrado no ClinicalTrials.gov NCT01465932.
Resumo:
Background: Previous studies show that chronic hemiparetic patients after stroke, presents inabilities to perform movements in paretic hemibody. This inability is induced by positive reinforcement of unsuccessful attempts, a concept called learned non-use. Forced use therapy (FUT) and constraint induced movement therapy (CIMT) were developed with the goal of reversing the learned non-use. These approaches have been proposed for the rehabilitation of the paretic upper limb (PUL). It is unknown what would be the possible effects of these approaches in the rehabilitation of gait and balance. Objectives: To evaluate the effect of Modified FUT (mFUT) and Modified CIMT (mCIMT) on the gait and balance during four weeks of treatment and 3 months follow-up. Methods: This study included thirty-seven hemiparetic post-stroke subjects that were randomly allocated into two groups based on the treatment protocol. The non-paretic UL was immobilized for a period of 23 hours per day, five days a week. Participants were evaluated at Baseline, 1st, 2nd, 3rd and 4th weeks, and three months after randomization. For the evaluation we used: The Stroke Impact Scale (SIS), Berg Balance Scale (BBS) and Fugl-Meyer Motor Assessment (FM). Gait was analyzed by the 10-meter walk test (T10) and Timed Up & Go test (TUG). Results: Both groups revealed a better health status (SIS), better balance, better use of lower limb (BBS and FM) and greater speed in gait (T10 and TUG), during the weeks of treatment and months of follow-up, compared to the baseline. Conclusion: The results show mFUT and mCIMT are effective in the rehabilitation of balance and gait. Trial Registration ACTRN12611000411943.
Resumo:
CONTEXTUALIZAÇÃO: A biofotogrametria é uma técnica difundida na área da saúde e, apesar dos cuidados metodológicos, há distorções nas leituras angulares das imagens fotográficas. OBJETIVO: Mensurar o erro das medidas angulares em imagens fotográficas com diferentes resoluções digitais em um objeto com ângulos pré-demarcados. MÉTODOS: Utilizou-se uma esfera de borracha com 52 cm de circunferência. O objeto foi previamente demarcado com ângulos de 10º, 30º, 60º e 90º, e os registros fotográficos foram realizados com o eixo focal da câmera a três metros de distância e perpendicular ao objeto, sem utilização de zoom óptico e com resolução de 3, 5 e 10 Megapixels (Mp). Todos os registros fotográficos foram armazenados, e os valores angulares foram analisados por um experimentador previamente treinado, utilizando o programa ImageJ. As aferições das medidas foram realizadas duas vezes, com intervalo de 15 dias entre elas. Posteriormente, foram calculados os valores de acurácia, erro relativo e em graus, precisão e Coeficiente de Correlação Intraclasse (ICC). RESULTADOS: Quando analisado o ângulo de 10º, a média da acurácia das medidas foi maior para os registros com resolução de 3 Mp em relação às resoluções de 5 e 10 Mp. O ICC foi considerado excelente para as três resoluções de imagem analisadas e, em relação aos ângulos analisados nos registros fotográficos, pôde-se verificar maior acurácia, menor erro relativo e em graus e maior precisão para o ângulo de 90º, independentemente da resolução da imagem. CONCLUSÃO: Os registros fotográficos realizados com a resolução de 3 Mp proporcionaram medidas de maiores valores de acurácia e precisão e menores valores de erro, sugerindo ser a resolução mais adequada para gerar imagem de ângulos de 10º e 30º.