921 resultados para Effective alveolar ventilation
Resumo:
This paper deals with the energy consumption and the evaluation of the performance of air supply systems for a ventilated room involving high- and low-level supplies. The energy performance assessment is based on the airflow rate, which is related to the fan power consumption by achieving the same environmental quality performance for each case. Four different ventilation systems are considered: wall displacement ventilation, confluent jets ventilation, impinging jet ventilation and a high level mixing ventilation system. The ventilation performance of these systems will be examined by means of achieving the same Air Distribution Index (ADI) for different cases. The widely used high-level supplies require much more fan power than those for low-level supplies for achieving the same value of ADI. In addition, the supply velocity, hence the supply dynamic pressure, for a high-level supply is much larger than for low-level supplies. This further increases the power consumption for high-level supply systems. The paper considers these factors and attempts to provide some guidelines on the difference in the energy consumption associated with high and low level air supply systems. This will be useful information for designers and to the authors' knowledge there is a lack of information available in the literature on this area of room air distribution. The energy performance of the above-mentioned ventilation systems has been evaluated on the basis of the fan power consumed which is related to the airflow rate required to provide equivalent indoor environment. The Air Distribution Index (ADI) is used to evaluate the indoor environment produced in the room by the ventilation strategy being used. The results reveal that mixing ventilation requires the highest fan power and the confluent jets ventilation needs the lowest fan power in order to achieve nearly the same value of ADI.
Resumo:
In designing modern office buildings, building spaces are frequently zoned by introducing internal partitioning, which may have a significant influence on the room air environment. This internal partitioning was studied by means of model test, numerical simulation, and statistical analysis as the final stage. In this paper, the results produced from the statistical analysis are summarized and presented.
Effect of internal partitioning on indoor air quality of rooms with mixing ventilation - basic study
Resumo:
The internal partitioning, which is frequently introduced in open-space planning due to its flexibility, was tested to study its effects on the room air quality as well as ventilation performance. For the study, physical tests using a small model room and numerical modeling using CFD computation were utilized to evaluate different test conditions employing mixing ventilation from the ceiling. The partition parameters, such as its location, height, and the gap underneath, as well as contaminant source location were tested under isothermal conditions. This paper summarizes the results from the study.
Resumo:
This paper presents an investigation of the natural ventilation cooling potential (NVCP) of office buildings in the five generally recognised climate zones in China using the Thermal Resistance Ventilation (TRV) model, which is a simplified, coupled, thermal and airflow model. The acceptable operative temperature for naturally conditioned space supplied by the ASHARE Standard 55-2004 has been used for the comfort temperature setting. Dynamic simulations for a typical office room in the five representative cities, which are Harbin, Beijing, Shanghai, Kunming and Guangzhou, have been carried out. The study demonstrates that the NVCP depends on the multiple impacts of climate, the building's thermal characteristics, internal gains, ventilation profiles and regimes. The work shows how the simplified method can be used to generate detailed, indoor, operative temperature data based on the various building conditions and control profiles which are used to investigate the NVCP at the strategic design stage. The simulation results presented in this paper can be used as a reference guideline for natural ventilation design in China.
Resumo:
The aim of this review paper is to present experimental methodologies and the mathematical approaches used to determine effective diffusivities of solutes in food materials. The paper commences by describing the diffusion phenomena related to solute mass transfer in foods and effective diffusivities. It then focuses on the mathematical formulation for the calculation of effective diffusivities considering different diffusion models based on Fick's second law of diffusion. Finally, experimental considerations for effective diffusivity determination are elucidated primarily based on the acquirement of a series of solute content versus time curves appropriate to the equation model chosen. Different factors contributing to the determination of the effective diffusivities such as the structure of food material, temperature, diffusion solvent, agitation, sampling, concentration and different techniques used are considered. (c) 2005 Elsevier Inc. All rights reserved.
Resumo:
There remains limited scientific evidence on the efficacy and safety of 'natural' therapies such as herbal remedies and dietary supplements. Nevertheless, breast cancer patients are particularly prone to purchasing such products because of the perception that 'natural' products are less toxic than conventional prescribed medicines. However, the potential for interactions of supplements with current medications, the potential for adverse effects from consumption at high levels, and the lack of disclosure of such treatments by the patient to their doctor are serious public health issues. Robust clinical trials are required to prove the efficacy and lack of adverse effects of such preparations, and communication between patients and doctors must be improved and doctors made more aware that their patients may be seeking advice and treatment from sources outside conventional medicine.
Resumo:
The aim of this study was to determine the cost effectiveness of influenza vaccination for healthy people aged 65-74 years living in the UK. People without risk factors for influenza (chronic heart, lung or renal disease, diabetic, immuno-suppressed or those living in an institution) were identified from 20 general practitioner (GP) practices in Liverpool in September 1999. 729/5875 (12.4%) eligible individuals were recruited and randomised to receive either influenza vaccine or placebo (ratio 3: 1)! with all participants receiving 23-valent-pneumococcal polysaccharide vaccine unless already administered. The primary analysis was the frequency of influenza as recorded by a GP diagnosis of pneumonia or influenza like illness. In 2000, the UK vaccination policy was changed with influenza vaccine becoming available. for all people aged 65 years and over irrespective of risk. As a consequence of this policy change. the study had to be fundamentally restructured and only results obtained over a one rather than the originally planned two-year randomised controlled trial framework were used. Results from 1999/2000 demonstrated no significant difference between groups for the primary outcome (relative risk 0.8, 95%, CI 0.16-4.1). In addition. there were no deaths or hospitalisations for influenza associated respiratory illness in either group. The subsequent analysis. using both national and local sources of evidence, estimated the following cost effectiveness indicators: (1) incremental NHS cost per GP consultation avoided = pound2000; (2) incremental NHS cost per hospital admission avoided = pound61,000: (3) incremental NHS cost per death avoided = pound1.900.000 and (4) incremental NHS cost per QALY gained = pound304,000. The analysis suggested that influenza vaccination in this Population would not be cost effective. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Objectives: To investigate people's views about the efficacy and specific risks of herbal, over-the-counter (OTC) conventional, and prescribed conventional medicines, and their likelihood of taking a second (herbal or OTC conventional) product in addition to a prescribed medicine. Methods: Experiment 1 (1 factor within-participant design); Experiment 2 (1 factor between-participant design). Convenience samples of general population were given a hypothetical scenario and required to make a number of judgements. Results: People believed herbal remedies to be less effective, but less risky than OTC and prescribed conventional medicines. Herbal medicines were not seen as being safer simply because of their easier availability. Participants indicated that they would be more likely to take a herbal medicine than a conventional OTC medicine in addition to a prescribed medicine, and less likely to consult their doctor in advance. Conclusion: People believe that herbal medicines are natural and relatively safe and can be used with less caution. People need to be given clear information about the risks and benefits of herbal medicines if they are to use such products safety and effectively. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
We have designed and implemented a low-cost digital system using closed-circuit television cameras coupled to a digital acquisition system for the recording of in vivo behavioral data in rodents and for allowing observation and recording of more than 10 animals simultaneously at a reduced cost, as compared with commercially available solutions. This system has been validated using two experimental rodent models: one involving chemically induced seizures and one assessing appetite and feeding. We present observational results showing comparable or improved levels of accuracy and observer consistency between this new system and traditional methods in these experimental models, discuss advantages of the presented system over conventional analog systems and commercially available digital systems, and propose possible extensions to the system and applications to non-rodent studies.