964 resultados para ESPECTROSCOPIA RAMAN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the first WDM numerical characterisation of crosstalk growth in cascaded Raman-Assisted Fibre Optical Parametric Amplifiers (RA-FOPAs). A cascade of ten RA-FOPAs results in ∼13dB lower crosstalk than the equivalent cascade of conventional FOPAs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Benzodiazepines are among the most prescribed compounds for anti-anxiety and are present in many toxicological screens. These drugs are also prominent in the commission of drug facilitated sexual assaults due their effects on the central nervous system. Due to their potency, a low dose of these compounds is often administered to victims; therefore, the target detection limit for these compounds in biological samples is 10 ng/mL. Currently these compounds are predominantly analyzed using immunoassay techniques; however more specific screening methods are needed. The goal of this dissertation was to develop a rapid, specific screening technique for benzodiazepines in urine samples utilizing surface-enhanced Raman spectroscopy (SERS), which has previously been shown be capable of to detect trace quantities of pharmaceutical compounds in aqueous solutions. Surface enhanced Raman spectroscopy has the advantage of overcoming the low sensitivity and fluorescence effects seen with conventional Raman spectroscopy. The spectra are obtained by applying an analyte onto a SERS-active metal substrate such as colloidal metal particles. SERS signals can be further increased with the addition of aggregate solutions. These agents cause the nanoparticles to amass and form hot-spots which increase the signal intensity. In this work, the colloidal particles are spherical gold nanoparticles in aqueous solution with an average size of approximately 30 nm. The optimum aggregating agent for the detection of benzodiazepines was determined to be 16.7 mM MgCl2, providing the highest signal intensities at the lowest drug concentrations with limits of detection between 0.5 and 127 ng/mL. A supported liquid extraction technique was utilized as a rapid clean extraction for benzodiazepines from urine at a pH of 5.0, allowing for clean extraction with limits of detection between 6 and 640 ng/mL. It was shown that at this pH other drugs that are prevalent in urine samples can be removed providing the selective detection of the benzodiazepine of interest. This technique has been shown to provide rapid (less than twenty minutes), sensitive, and specific detection of benzodiazepines at low concentrations in urine. It provides the forensic community with a sensitive and specific screening technique for the detection of benzodiazepines in drug facilitated assault cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cadwaladerite (Al(OH)2Cl∙4H2O) collected from Cerro Pintados, Chile described by Gordon in 1941 is designated as “doubtful” by the IMA. Material collected from the same locality in 2015 resembling the description of cadwaladerite gave a powder XRD pattern similar to lesukite (Al2(OH)5Cl∙2H2O). However, Gordon provided no X-ray data for his material from Cerro Pintados. In order to determine whether cadwaladerite and lesukite are the same mineral species, measurements were made on a suite of samples from various localities. A portion of the material collected by Gordon in 1941 was also obtained from the Mineralogical Museum of Harvard University. Type material of lesukite from a fumarolic environment at the Tolbachik Fissure in Kamchatka, Russia was obtained as well as lesukite from the Maria Mine, Chile (Arica Province) and a previously undescribed locality for lesukite (Barranaca del Sulfato, Mejillones Peninsula, Antofagasta Province). All samples are yellow to yellow-orange in colour and all exhibit small cubic crystals (up to 50µm), even Gordon’s cadwaladerite which was thought to be amorphous. The Chilean samples are all associated with halite and sometimes with anhydrite. These five samples were studied by SEM, FTIR, powder XRD, and Raman spectroscopy. A ratio of Al:Cl less than or equal to 1.3:1 was observed for all the samples, including measurements made on lesukite from the Russian locality Vergasova et al. studied in 1997, and determined to have a 2:1 ratio. SEM-EDS analyses also show all samples to have minor iron substitution, as well as copper substitution in two samples. FTIR spectra are very similar for all samples. Raman spectroscopy done on both samples collected in Cerro Pintados and the Russian lesukite gave similar spectra. Powder XRD analyses on all samples showed spectra identified to be lesukite, including Gordon’s cadwaladerite. Crystal cell parameters calculated from powder XRD ranged from 19.778Å to 19.878Å. Results using modern instrumental techniques confirm Gordon’s cadwaladerite, collected in 1939 and described in 1941, and lesukite are the same mineral species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface-enhanced Raman spectroscopy (SERS) is now widely used as a rapid and inexpensive tool for chemical/biochemical analysis. The method can give enormous increases in the intensities of the Raman signals of low-concentration molecular targets if they are adsorbed on suitable enhancing substrates, which are typically composed of nanostructured Ag or Au. However, the features of SERS that allow it to be used as a chemical sensor also mean that it can be used as a powerful probe of the surface chemistry of any nanostructured material that can provide SERS enhancement. This is important because it is the surface chemistry that controls how these materials interact with their local environment and, in real applications, this interaction can be more important than more commonly measured properties such as morphology or plasmonic absorption. Here, the opportunity that this approach to SERS provides is illustrated with examples where the surface chemistry is both characterized and controlled in order to create functional nanomaterials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raman analysis of dilute aqueous solutions is normally prevented by their low signal levels. A very general method to increase the concentration to detectable levels is to evaporate droplets of the sample to dryness, creating solid deposits which are then Raman probed. Here, superhydrophobic (SHP) wires with hydrophilic tips have been used as supports for drying droplets, which have the advantage that the residue is automatically deposited at the tip. The SHP wires were readily prepared in minutes using electroless galvanic deposition of Ag onto copper wires followed by modification with a polyfluorothiol (3,3,4,4,5,5,6,6,7,7,8,8,9,9,10,10,10-heptadecafluoro-1-decanethiol, HDFT). Cutting the coated wires with a scalpel revealed hydrophilic tips which could support droplets whose maximum size was determined by the wire diameter. Typically, 230 μm wires were used to support 0.6 μL droplets. Evaporation of dilute melamine droplets gave solid deposits which could be observed by scanning electron microscopy (SEM) and Raman spectroscopy. The limit of detection for melamine using a two stage evaporation procedure was 1 × 10-6 mol dm-3. The physical appearance of dried droplets of sucrose and glucose showed that the samples retained significant amounts of water, even under high vacuum. Nonetheless, the Raman detection limits of sucrose and glucose were 5 × 10-4 and 2.5 × 10-3 mol dm-3, respectively, which is similar to the sensitivity reported for surface-enhanced Raman spectroscopy (SERS) detection of glucose. It was also possible to quantify the two sugars in mixtures at concentrations which were similar to those found in human blood through multivariate analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large (10 × 10 cm) sheets of surface-enhanced Raman spectroscopy (SERS) active polymer have been prepared by stabilising metal nanoparticle aggregates within dry hydroxyethylcellulose (HEC) films. In these films the aggregates are protected by the polymer matrix during storage but in use they are released when aqueous analyte droplets cause the films to swell to their gel form. The fact that these "Poly-SERS" films can be prepared in bulk but then cut to size and stored in air before use means that they provide a cost effective and convenient method for routine SERS analysis. Here we have tested both Ag and Au Poly-SERS films for use in point-of-care monitoring of therapeutic drugs, using phenytoin as the test compound. Phenytoin in water could readily be detected using Ag Poly-SERS films but dissolving the compound in phosphate buffered saline (PBS) to mimic body fluid samples caused loss of the drug signal due to competition for metal surface sites from Cl- ions in the buffer solution. However, with Au Poly-SERS films there was no detectable interference from Cl- and these materials allowed phenytoin to be detected at 1.8 mg L-1, even in PBS. The target range of detection of phenytoin in therapeutic drug monitoring is 10-20 mg L-1. With the Au Poly-SERS films, the absolute signal generated by a given concentration of phenytoin was lower for the films than for the parent colloid but the SERS signals were still high enough to be used for therapeutic monitoring, so the cost in sensitivity for moving from simple aqueous colloids to films is not so large that it outweighs the advantages which the films bring for practical applications, in particular their ease of use and long shelf life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of seized "legal high'' samples and pure novel psychoactive substances have been examined by surface-enhanced Raman spectroscopy using polymer-stabilized Ag nanoparticle (Poly-SERS) films. The films both quenched fluorescence in bulk samples and allowed identification of mu g quantities of drugs collected with wet swabs from contaminated surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this work was to develop a novel dimensionality reduction technique as a part of an integrated pattern recognition solution capable of identifying adulterants such as hazelnut oil in extra virgin olive oil at low percentages based on spectroscopic chemical fingerprints. A novel Continuous Locality Preserving Projections (CLPP) technique is proposed which allows the modelling of the continuous nature of the produced in-house admixtures as data series instead of discrete points. The maintenance of the continuous structure of the data manifold enables the better visualisation of this examined classification problem and facilitates the more accurate utilisation of the manifold for detecting the adulterants. The performance of the proposed technique is validated with two different spectroscopic techniques (Raman and Fourier transform infrared, FT-IR). In all cases studied, CLPP accompanied by k-Nearest Neighbors (kNN) algorithm was found to outperform any other state-of-the-art pattern recognition techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le tradizionali tecniche usate per l’analisi della struttura e della composizione comprendono, tra le altre, microscopia ottica, microscopia elettronica, diffrazione a raggi X e analisi chimica. In generale però, la maggior parte di questi metodi richiede una procedura di preparazione che può modificare la struttura o la composizione del campione. È necessario infatti che il campione non subisca alterazioni particolari durante la fase di preparazioni in modo tale che le condizioni fisiologiche rimangano il più possibile simili a quelle che si hanno in situ. Una tecnica che ultimamente sta diventando sempre più significativa in ambito biomedico è la spettroscopia Raman. Innanzitutto con l’analisi Raman la quantità di materiale da studiare per ottenere buoni risultati è minima, visto che possono essere studiati campioni che vanno dai micro ai nanogrammi; inoltre, possono essere analizzati campioni umidi e a pressione atmosferica, condizioni che rispecchiano verosimilmente quelle fisiologiche. Questo tipo di analisi è inoltre vantaggiosa dato che riesce a identificare diversi composti chimici, ha un’elevata risoluzione spaziale (0.6-1µm), riuscendo quindi ad analizzare campioni molto piccoli, ha tempi di misura brevi e può essere utilizzato più volte sullo stesso campione senza che quest’ultimo venga danneggiato. Nel seguente elaborato si sono riportati i risultati di diversi studi condotti sull’idrossiapatite naturale/biologica e sintetica ottenuti mediante questa tecnica spettroscopica. In particolare, ci si è soffermati sulla diversa concentrazione di OH- presente nell’apatite stechiometrica rispetto a quella biologica e di come tale concentrazione sia influenzata dalla presenza o meno dello ione carbonato. Si riportano inoltre le analisi condotte su campioni sintetici e biologici per comprendere se le molecole di acqua si trovino all’interno della struttura del minerale (acqua di bulk) o se siano solamente assorbite in superficie.

Relevância:

20.00% 20.00%

Publicador: