840 resultados para ELECTROLYTE CONCENTRATION
Resumo:
Morphine is a potent analgesic opioid used extensively for pain treatment. During the last decade, global consumption grew more than 4-fold. However, molecular mechanisms elicited by morphine are not totally understood. Thus, a growing literature indicates that there are additional actions to the analgesic effect. Previous studies about morphine and oxidative stress are controversial and used concentrations outside the range of clinical practice. Therefore, in this study, we hypothesized that a therapeutic concentration of morphine (1 μM) would show a protective effect in a traditional model of oxidative stress. We exposed the C6 glioma cell line to hydrogen peroxide (H2O2) and/or morphine for 24 h and evaluated cell viability, lipid peroxidation, and levels of sulfhydryl groups (an indicator of the redox state of the cell). Morphine did not prevent the decrease in cell viability provoked by H2O2) but partially prevented lipid peroxidation caused by 0.0025% H2O2) (a concentration allowing more than 90% cell viability). Interestingly, this opioid did not alter the increased levels of sulfhydryl groups produced by exposure to 0.0025% H2O2), opening the possibility that alternative molecular mechanisms (a direct scavenging activity or the inhibition of NAPDH oxidase) may explain the protective effect registered in the lipid peroxidation assay. Our results demonstrate, for the first time, that morphine in usual analgesic doses may contribute to minimizing oxidative stress in cells of glial origin. This study supports the importance of employing concentrations similar to those used in clinical practice for a better approximation between experimental models and the clinical setting.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The pH values near a planar dissociating membrane are studied under a mean field approximation using the Poisson-Boltzmann equation and its linear form. The equations are solved in planar symmetry with the consideration that the charge density on the dissociating membrane surface results from an equilibrium process with the neighboring electrolyte. Results for the membrane dissociation degree are presented as a function of the electrolyte ionic strength and membrane surface charge density. Our calculations indicate that pH values have an appreciable variation within 2 nm from the membrane. It is shown that the dissociation process is enhanced due to the presence of bivalent ions and that pH values acquire better stability than in an electrolyte containing univalent ions.
Resumo:
Maceration and supercritical fluid extraction were used to prepare extracts from parts of plants (Holostylis reniformis) collected in two different regions of Brazil. ¹H NMR, HPLC-DAD-ESI/MS, HPLC-DAD, GC-MS, and chemometric techniques were used to analyse lignans in the extracts and showed that yields of SFE-CO2 were less than or equal to those of hexane maceration extracts. These analyses, in conjunction with the concentrations of aliphatic hydrocarbons, fatty acids and their methyl and ethyl derivatives in the extracts, also allowed the chemical composition of parts and provenance of the plant to be differentiated.
Resumo:
Pós-graduação em Química - IQ
Resumo:
Examining three bleaching systems, this in vivo clinical trial evaluated the relationship among tooth sensitivity, light activation, and agent concentration, and it correlated dental sensitivity with tooth thickness.Materials and Methods: Eighty-seven volunteer patients were included. Inclusion criteria were the presence of anterior teeth without restorations as well as the absence of a previous bleaching experience and absence of non-carious cervical lesions or dental pain. Exclusion criteria included pregnancy or breastfeeding, a maximum of TF3 hypoplasia, tetracycline-fluorosis stains, malpositioned teeth, orthodontic treatment, periodontal disease, and/or analgesic/anti-inflammatory intake. Patients were randomly assigned to three bleaching groups: Group A (n=25) was treated with 15% H2O2 and nitrogenous-titanium-dioxide and was light activated (Lase Peroxide Lite, DMC, SaoCarlos, Sao Paulo, Brazil); Group B (n=27) was treated with 35% H2O2 and was light activated (Lase Peroxide Sensy, DMC); and Group C (n=35) was treated with 35% H2O2 (White Gold Office, Dentsply, 38West Clark Ave., Milford, USA) without light activation. Tooth sensitivity (TS) was self-reported by the patients using the visual analog scale (VAS) at baseline (TSO), immediately after treatment (TSI), and at seven days after treatment (TS7). In 46 patients, tooth thickness was determined by computed tomography. TSO, TSI, and TS7 were compared between the A and B groups to determine the effect of concentration and between the B and C groups to determine the effect of light using analysis of covariance. The correlation between tooth thickness and TSI was determined by Spearman Rho test (SPSS 15).Results: Eighty-seven patients were evaluated at baseline, and 61 were evaluated at seven days. Separated by groups, tooth sensitivity, expressed as VAS value at the time points TS0, TS1, and TS7, respectively, were as follows: Group A: 13.76 +/- 13.53, 24.40 +/- 25.24, and 5.94 +/- 5.5; Group B: 15.07 +/- 18.14, 42.4 +/- 31.78, and 8.68 +/- 17.99; and Group C: 10.80 +/- 14.83, 31.51 +/- 29.34, and 7.24 +/- 9.2. Group A showed significantly lower tooth sensitivity than group B at TSI (p=0.032). No differences were observed in the tooth sensitivities between groups B and C. No correlation was encountered between tooth thickness and tooth sensitivity immediately after treatment (Rho=-0.088,p=0.563). The median tooth thickness was 2.78 +/- 0.21 mm.Conclusions: Increases in the concentration of bleaching agents directly affect tooth sensitivity, and LED/laser activation and tooth thickness are not correlated with tooth sensitivity after dental bleaching.
Resumo:
Based on extensive Monte Carlo simulations and analytical considerations we study the electrostatically driven adsorption of flexible polyelectrolyte chains onto charged Janus nanospheres. These net-neutral colloids are composed of two equally but oppositely charged hemispheres. The critical binding conditions for polyelectrolyte chains are analysed as function of the radius of the Janus particle and its surface charge density, as well as the salt concentration in the ambient solution. Specifically for the adsorption of finite-length polyelectrolyte chains onto Janus nanoparticles, we demonstrate that the critical adsorption conditions drastically differ when the size of the Janus particle or the screening length of the electrolyte are varied. We compare the scaling laws obtained for the adsorption-desorption threshold to the known results for uniformly charged spherical particles, observing significant disparities. We also contrast the changes to the polyelectrolyte chain conformations close to the surface of the Janus nanoparticles as compared to those for simple spherical particles. Finally, we discuss experimentally relevant physicochemical systems for which our simulations results may become important. In particular, we observe similar trends with polyelectrolyte complexation with oppositely but heterogeneously charged proteins.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This study aimed to evaluate and correlate intraocular pressure (IOP), endothelial cell density (CD), and hexagonality (HEX), and the aqueous humor prostaglandin E-2 (PGE(2)) concentration in dogs with mature (MG, n = 8) and hypermature (HG, n = 8) cataracts. Eight laboratory beagles with no ocular abnormalities were included as a control group (CG). The IOP was measured using a digital applanation tonometer. Noncontact specular microscopy was used to evaluate CD and HEX. Samples of aqueous humor were used to determine prostaglandin E-2 concentration using enzyme-linked immunoassay. Data were compared by ANOVA and Bonferroni's multiple comparison test, and possible correlations among the PGE(2) aqueous concentration and corneal endothelium cell parameters were assessed by Person's test (P < 0.05). Average values of IOP (P = 0.45) and CD (P = 0.39) were not significantly different between MG, HM, and CG. Average values of HEX were lower, and PGE(2) concentration was increased in the MG and HG in comparison with CG (P < 0.05); however, such parameters did not change significantly between MG and HG (P > 0.05). PGE(2) values did not correlate with IOP, CD, and HEX in any group (P > 0.05). Although there were a small number of dogs studied, our results demonstrated that cataract progression from mature to hypermature did not have a significant change in PGE(2) aqueous concentration, IOP, corneal endothelial cell count, or morphology. In addition, PGE(2) concentration was not correlated with parameters of the corneal endothelium or IOP in dogs with mature or hypermature cataracts.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)