962 resultados para Digital-to-analog converters
Resumo:
The present study was carried out to check whether classic osteometric parameters can be determined from the 3D reconstructions of MSCT (multislice computed tomography) scans acquired in the context of the Virtopsy project. To this end, four isolated and macerated skulls were examined by six examiners. First the skulls were conventionally (manually) measured using 32 internationally accepted linear measurements. Then the skulls were scanned by the use of MSCT with slice thicknesses of 1.25 mm and 0.63 mm, and the 33 measurements were virtually determined on the digital 3D reconstructions of the skulls. The results of the traditional and the digital measurements were compared for each examiner to figure out variations. Furthermore, several parameters were measured on the cranium and postcranium during an autopsy and compared to the values that had been measured on a 3D reconstruction from a previously acquired postmortem MSCT scan. The results indicate that equivalent osteometric values can be obtained from digital 3D reconstructions from MSCT scans using a slice thickness of 1.25 mm, and from conventional manual examinations. The measurements taken from a corpse during an autopsy could also be validated with the methods used for the digital 3D reconstructions in the context of the Virtopsy project. Future aims are the assessment and biostatistical evaluation in respect to sex, age and stature of all data sets stored in the Virtopsy project so far, as well as of future data sets. Furthermore, a definition of new parameters, only measurable with the aid of MSCT data would be conceivable.
Resumo:
El debat sobiranista català està a l‟ordre del dia i actualment no passa desapercebut en cap mitjà de comunicació ni tampoc en el món polític, econòmic i empresarial. El fet d‟estar tan viva una temàtica així de delicada està ocasionant controvèrsies dins l‟empresariat català o que té la seva empresa ubicada a Catalunya perquè tot plegat provoca moltes incerteses, que són el pitjor enemic dels empresaris i dels negocis. Tanmateix, però, les informacions publicades o emeses venen marcades per les opinions polítiques i periodístiques, que es troben censurades en certa mesura perquè segueixen una determinada línia política i/o editorial. Per això s‟ha elaborat un reportatge digital focalitzat en l‟empresariat català i l‟encaix Catalunya-Espanya que pretén aportar noves valoracions entorn a aquest debat donant veu a empresaris i professionals, entre altres. La part teòrica de la memòria defineix els conceptes bàsics que són de forçat coneixement per realitzar una part pràctica que ha de ser entesa per qualsevol persona i que s‟ha de tractar amb la major objectivitat possible. Per això, el web http://laquestiocatalana.cat aporta un llenguatge planer i les eines bàsiques per donar a conèixer una matèria molt criticada per alguns sectors. A través d‟entrevistes a personatges rellevants, el web introdueix nous punts de vista sobre una qüestió marcada, a simple vista, per la preocupació d‟un possible boicot per part d‟Espanya. Però aquesta no sembla ser la principal inquietud dels entesos, i és que hi ha altres aspectes encara més alarmants que poden influir en l‟empresariat i que no són tractats per cap mitjà de comunicació convencional.
Resumo:
The main difficulty in the successful treatment of metastatic melanoma is that this type of cancer is known to be resistant to chemotherapy. Chemotherapy remains the treatment of choice, and dacarbazine (DTIC) is the best standard treatment. The DM-1 compound is a curcumin analog that possesses several curcumin characteristics, such as antiproliferative, antitumor, and antimetastatic properties. The objective of this study was to evaluate the signaling pathways involved in melanoma cell death after treatment with DM-1 compared to the standard agent for melanoma treatment, DTIC. Cell death was evaluated by flow cytometry for annexin V and iodide propide, cleaved caspase 8, and TNF-R1 expression. Hoechst 33342 staining was evaluated by fluorescent microscopy; lipid peroxidation and cell viability (MTT) were evaluated by colorimetric assays. The antiproliferative effects of the drugs were evaluated by flow cytometry for cyclin D1 and Ki67 expression. Mice bearing B16F10 melanoma were treated with DTIC, DM-1, or both therapies. DM-1 induced significant apoptosis as indicated by the presence of cleaved caspase 8 and an increase in TNF-R1 expression in melanoma cells. Furthermore, DM-1 had antiproliferative effects in this the same cell line. DTIC caused cell death primarily by necrosis, and a smaller melanoma cell population underwent apoptosis. DTIC induced oxidative stress and several physiological changes in normal melanocytes, whereas DM-1 did not significantly affect the normal cells. DM-1 antitumor therapy in vivo showed tumor burden decrease with DM-1 monotherapy or in combination with DTIC, besides survival rate increase. Altogether, these data confirm DM-1 as a chemotherapeutic agent with effective tumor control properties and a lower incidence of side effects in normal cells compared to DTIC.
Resumo:
In this review, we summarize how the new concept of digital optics applied to the field of holographic microscopy has allowed the development of a reliable and flexible digital holographic quantitative phase microscopy (DH-QPM) technique at the nanoscale particularly suitable for cell imaging. Particular emphasis is placed on the original biological information provided by the quantitative phase signal. We present the most relevant DH-QPM applications in the field of cell biology, including automated cell counts, recognition, classification, three-dimensional tracking, discrimination between physiological and pathophysiological states, and the study of cell membrane fluctuations at the nanoscale. In the last part, original results show how DH-QPM can address two important issues in the field of neurobiology, namely, multiple-site optical recording of neuronal activity and noninvasive visualization of dendritic spine dynamics resulting from a full digital holographic microscopy tomographic approach.
Resumo:
The SHRP Modified Georgia Digital Faultmeter was loaned to the Iowa Department of Transportation in January 1993 for evaluation. A study was undertaken comparing the faultmeter to Iowa's current method of fault measurement. The following conclusions were made after comparing the faultmeter to Iowa's gauge: The faultmeter was lighter and easier to maneuver and position. The faultmeter's direct readout was quicker to read. The faultmeter has increased precision. The faultmeter gave consistently lower fault readings than the Iowa gauge.
Resumo:
Context: Ovarian tumors (OT) typing is a competency expected from pathologists, with significant clinical implications. OT however come in numerous different types, some rather rare, with the consequence of few opportunities for practice in some departments. Aim: Our aim was to design a tool for pathologists to train in less common OT typing. Method and Results: Representative slides of 20 less common OT were scanned (Nano Zoomer Digital Hamamatsu®) and the diagnostic algorithm proposed by Young and Scully applied to each case (Young RH and Scully RE, Seminars in Diagnostic Pathology 2001, 18: 161-235) to include: recognition of morphological pattern(s); shortlisting of differential diagnosis; proposition of relevant immunohistochemical markers. The next steps of this project will be: evaluation of the tool in several post-graduate training centers in Europe and Québec; improvement of its design based on evaluation results; diffusion to a larger public. Discussion: In clinical medicine, solving many cases is recognized as of utmost importance for a novice to become an expert. This project relies on the virtual slides technology to provide pathologists with a learning tool aimed at increasing their skills in OT typing. After due evaluation, this model might be extended to other uncommon tumors.
Resumo:
Objective. Collaborative quality improvement programs have been successfully used to manage chronic diseases in adults and acute lung complications in premature infants. Their effectiveness to improve pain management in acute care hospitals is currently unknown. The purpose of this study was to determine whether a collaborative quality improvement program implemented at hospital level could improve pain management and overall pain relief. Design.To assess the effectiveness of the program, we performed a before-after trial comparing patient's self-reported pain management and experience before and after program implementation. We included all adult patients hospitalized for more than 24 hours and discharged either to their home or to a nursing facility, between March 1, 2001 and March 31, 2001 (before program implementation) and between September 15, 2005 and October 15, 2005 (after program implementation). Setting.A teaching hospital of 2,096 beds in Geneva, Switzerland. Patients.All adult patients hospitalized for more than 24 hours and discharged between 1 to 31 March 2001 (before program) and 15 September to 15 October 2005 (after program implementation). Interventions.Implementation of a collaborative quality improvement program using multifaceted interventions (staff education, opinion leaders, patient education, audit, and feedback) to improve pain management at hospital level. Outcome Measures.Patient-reported pain experience, pain management, and overall hospital experience based on the Picker Patient Experience questionnaire, perceived health (SF-36 Health survey). Results.After implementation of the program only 2.3% of the patients reported having no pain relief during their hospital stay (vs 4.5% in 2001, P = 0.05). Among nonsurgical patients, improvements were observed for pain assessment (42.3% vs 27.9% of the patients had pain intensity measured with a visual analog scale, P = 0.012), pain management (staff did everything they could to help in 78.9% vs 67.9% of cases P = 0.003), and pain relief (70.4% vs 57.3% of patients reported full pain relief P = 0.008). In surgical patients, pain assessment also improved (53.7.3% vs 37.6%) as well as pain treatment. More patients received treatments to relieve pain regularly or intermittently after program implementation (95.1% vs 91.9% P = 0.046). Conclusion.Implementation of a collaborative quality improvement program at hospital level improved both pain management and pain relief in patients. Further studies are needed to determine the overall cost-effectiveness of such programs.
Resumo:
El trabajo muestra un estudio comparativo de las soluciones que plantean diferentes soluciones comerciales y/o libres para la adecuación o no a su integración en un entorno como es el campus virtual de la UOC. Para esto se ha elaborado una lista de indicadores clave y más adelante se ha hecho una valoración de la integración en el entorno UOC, relacionando los indicadores anteriores con los requerimientos de la UOC. Investigando previamente cuales son estos. Por último se ha comprobado y corroborado la posible integración de la solución elegida al campus virtual, con el desarrollo de una pequeña aplicación web.
Resumo:
Background: Visual analog scales (VAS) are used to assess readiness to changeconstructs, which are often considered critical for change.Objective: We studied whether 3 constructs -readiness to change, importance of changing and confidence inability to change- predict risk status 6 months later in 20 year-old men with either orboth of two behaviors: risky drinking and smoking. Methods: 577 participants in abrief intervention randomized trial were assessed at baseline and 6 months later onalcohol and tobacco consumption and with three 1-10 VAS (readiness, importance,confidence) for each behavior. For each behavior, we used one regression model foreach constructs. Models controlled for receipt of a brief intervention and used thelowest level (1-4) in each construct as the reference group (vs medium (5-7) and high(8-10) levels).Results: Among the 475 risky drinkers, mean (SD) readiness, importance and confidence to change drinking were 4.0 (3.1), 2.8 (2.2) and 7.2 (3.0).Readiness was not associated with being alcohol-risk free 6 months later (OR 1.3[0.7; 2.2] and 1.4 [0.8; 2.6] for medium and high readiness). High importance andhigh confidence were associated with being risk free (OR 0.9 [0.5; 1.8] and 2.9 [1.2;7.5] for medium and high importance; 2.1 [1.0;4.8] and 2.8 [1.5;5.6] for medium andhigh confidence). Among the 320 smokers, mean readiness, importance andconfidence to change smoking were 4.6 (2.6), 5.3 (2.6) and 5.9 (2.6). Neitherreadiness nor importance were associated with being smoking free (OR 2.1 [0.9; 4.7]and 2.1 [0.8; 5.8] for medium and high readiness; 1.4 [0.6; 3.4] and 2.1 [0.8; 5.4] formedium and high importance). High confidence was associated with being smokingfree (OR 2.2 [0.8;6.6] and 3.4 [1.2;9.8] for medium and high confidence).Conclusions: For drinking and smoking, high confidence in ability to change wasassociated -with similar magnitude- with a favorable outcome. This points to thevalue of confidence as an important predictor of successful change.
Resumo:
Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative method based on the detectability index (d') calculated for a non-prewhitened model observer with an eye filter (NPWE). The detectability index was calculated from the normalized noise power spectrum and image contrast, both measured from an image of a 5 cm poly(methyl methacrylate) phantom containing a 0.2 mm thick aluminium square, and the pre-sampling modulation transfer function. This was performed as a function of air kerma at the detector for 11 different digital mammography systems. These calculated d' values were compared against threshold gold thickness (T) results measured with the CDMAM test object and against derived theoretical relationships. A simple relationship was found between T and d', as a function of detector air kerma; a linear relationship was found between d' and contrast-to-noise ratio. The values of threshold thickness used to specify acceptable performance in the European Guidelines for 0.10 and 0.25 mm diameter discs were equivalent to threshold calculated detectability indices of 1.05 and 6.30, respectively. The NPWE method is a validated alternative to CDMAM scoring for use in the image quality specification, quality control and optimization of digital x-ray systems for screening mammography.
Resumo:
During John Lake's visit to Barcelona to take part in a seminar organized by the Facultat de Biblioteconomia i Documentació (Department of Library and Information Science) at the University of Barcelona (UB)1 EPI sought an interview to further explore some of the themes addressed in the seminar, drawing on his extensive experience in the world of public libraries.
Resumo:
PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.
Resumo:
The potential of digital holography for complex manipulation of micron-sized particles with optical tweezers has been clearly demonstrated. By contrast, its use in quantitative experiments has been rather limited, partly due to fluctuations introduced by the spatial light modulator (SLM) that displays the kinoforms. This is an important issue when high temporal or spatial stability is a concern. We have investigated the performance of both an analog-addressed and a digitally-addressed SLM, measuring the phase fluctuations of the modulated beam and evaluating the resulting positional stability of a holographic trap. We show that, despite imparting a more unstable modulation to the wavefront, our digitally-addressed SLM generates optical traps in the sample plane stable enough for most applications. We further show that traps produced by the analog-addressed SLM exhibit a superior pointing stability, better than 1 nm, which is comparable to that of non-holographic tweezers. These results suggest a means to implement precision force measurement experiments with holographic optical tweezers (HOTs).
Resumo:
In our capacity as creative artists, researchers and fine arts professors, most part of our activity focuses on the relationships between people and creativity, technology, and resources, and, most frequently, what we aim to offer are new enjoyable and subversive ways of interacting with these three fields. As art teachers, we ask 'why and how' to teach dynamic bearing in mind that digital technology will undoubtedly impact on contemporary art practice.