985 resultados para Detector uniformity
Resumo:
The Short Baseline Neutrino Program at Fermilab aims to confirm or definitely rule out the existence of sterile neutrinos at the eV mass scale. The program will perform the most sensitive search in both the nue appearance and numu disappearance channels along the Booster Neutrino Beamline. The far detector, ICARUS-T600, is a high-granularity Liquid Argon Time Projection Chamber located at 600 m from the Booster neutrino source and at shallow depth, thus exposed to a large flux of cosmic particles. Additionally, ICARUS is located 6 degrees off axis with respect to the Neutrino beam from the Main Injector. This thesis presents the construction, installation and commissioning of the ICARUS Cosmic Ray Tagger system, providing a 4 pi coverage of the active liquid argon volume. By exploiting only the precise nanosecond scale synchronization of the cosmic tagger and the PMT optical flashes it is possible to determine if an event was likely triggered by a cosmic particle. The results show that using the Top Cosmic Ray Tagger alone a conservative rejection larger than 65% of the cosmic induced background can be achieved. Additionally, by requiring the absence of hits in the whole cosmic tagger system it is possible to perform a pre-selection of contained neutrino events ahead of the full event reconstruction.
Resumo:
The neutrino mass ordering and the leptonic CP violation phase are key parameters of the three-neutrino flavour mixing still to be determined. Measuring these parameters is the main goal of DUNE, a next generation Long Baseline neutrino experiment under construction in the United States. DUNE will feature a Near and a Far Detector site. An important component of the Near detector complex is the SAND apparatus, which will include GRAIN, a novel liquid Argon detector that aims at imaging neutrino interactions using scintillation light. For this purpose, an innovative optical readout system based on Coded Aperture Masks is under study. This thesis work is aimed at a first quantitative assessment of a 3D neutrino event reconstruction algorithm for GRAIN. The processing procedure is optimized and the reconstruction performance is evaluated. Promising results are obtained.
Resumo:
L’Electron Ion Collider (EIC) è un futuro acceleratore di particelle che ha l’obiettivo di approfondire le nostre conoscenze riguardo l’interazione forte, una delle quattro interazioni fondamentali della natura, attraverso collisioni di elettroni su nuclei e protoni. L’infrastruttura del futuro detector comprende un sistema d’identificazione basato sull’emissione di luce Cherenkov, un fenomeno che permette di risalire alla massa delle particelle. Una delle configurazioni prese in considerazione per questo sistema è il dual-radiator RICH, basato sulla presenza di due radiatori all’esterno dei quali si trovano dei fotorivelatori. Un’opzione per questi sensori sono i fotorivelatori al silicio SiPM, oggetto di questo lavoro di tesi. L’obiettivo dell’attività è lo studio di un set-up per la caratterizzazione della risposta di sensori SiPM a basse temperature, illuminati attraverso un LED. Dopo un’analisi preliminare per determinare le condizioni di lavoro, si è trovato che la misura è stabile entro un errore del 3.5%.
Resumo:
DUNE (Deep Underground Neutrino Experiment) è un esperimento internazionale attualmente in costruzione al laboratorio Fermilab in Illinois, Stati Uniti. Il suo scopo sarà quello di studiare alcuni dei fenomeni e quesiti aperti che riguardano i neutrini: particelle debolmente interagenti facenti parte del Modello Standard. In particolare DUNE intende studiare il fenomeno dell'oscillazione di sapore dei neutrini, osservare neutrini provenienti da supernove e stelle di neutroni per studiarne la formazione e ricercare l'eventuale decadimento dei protoni. L'esperimento sarà formato da due siti sperimentali distanti circa 1300 km tra loro: il Near Detector situato a Fermilab ed il Far Detector, situato al Sanford Underground Research Facility (SURF) in South Dakota. Questa tesi è rivolta in particolare al sistema di fotorivelazione del Far Detector, che utilizza fotomoltiplicatori al silicio (Silicon Photomultipliers, o SiPM). Questi dispositivi dovranno funzionare in condizioni criogeniche in argon liquido, perciò è stata avviata un'intensiva campagna di test volta alla caratterizzazione e validazione dei sensori che saranno montati nell'apparato. La sezione INFN di Bologna è coinvolta in questa campagna e dovrà testare una parte dei SiPM destinati all'impiego in DUNE. A tale scopo è stato realizzato, nei laboratori INFN, un sistema per il test di tali dispositivi in criogenia su larga scala. L'attività di tesi ha previsto la caratterizzazione di diversi SiPM sia a temperatura ambiente sia in criogenia e l'analisi delle distribuzioni statistiche dei parametri di diversi campioni di SiPM.
Resumo:
The High Energy Rapid Modular Ensemble of Satellites (HERMES) is a new mission concept involving the development of a constellation of six CubeSats in low Earth orbit with new miniaturized instruments that host a hybrid Silicon Drift Detector/GAGG:Ce based system for X-ray and γ-ray detection, aiming to monitor high-energy cosmic transients, such as Gamma Ray Bursts and the electromagnetic counterparts of gravitational wave events. The HERMES constellation will also operate together with the Australian-Italian SpIRIT mission, which will house a HERMES-like detector. The HERMES pathfinder mini-constellation, consisting of six satellites plus SpIRIT, is likely to be launched in 2023. The HERMES detectors are based on the heritage of the Italian ReDSoX collaboration, with joint design and production by INFN-Trieste and Fondazione Bruno Kessler, and the involvement of several Italian research institutes and universities. An application-specific, low-noise, low-power integrated circuit (ASIC) called LYRA was conceived and designed for the HERMES readout electronics. My thesis project focuses on the ground calibrations of the first HERMES and SpIRIT flight detectors, with a performance assessment and characterization of the detectors. The first part of this work addresses measurements and experimental tests on laboratory prototypes of the HERMES detectors and their front-end electronics, while the second part is based on the design of the experimental setup for flight detector calibrations and related functional tests for data acquisition, as well as the development of the calibration software. In more detail, the calibration parameters (such as the gain of each detector channel) are determined using measurements with radioactive sources, performed at different operating temperatures between -20°C and +20°C by placing the detector in a suitable climate chamber. The final part of the thesis involves the analysis of the calibration data and a discussion of the results.
Resumo:
Il lavoro presentato in questa tesi analizza il comportamento elettrico di prototipi di sensori Low-Gain Avalanche Detector (LGAD) ultrasottili. L'analisi consiste in una verifica sperimentale delle caratteristiche attese di questi sensori, che sono stati selezionati come possibili candidati per la realizzazione del sistema di Time-Of-Flight (TOF) nell'esperimento ALICE 3. Concepito come evoluzione dell'esperimento ALICE attualmente in funzione al CERN, ALICE 3 rappresenta l'archetipo di una nuova generazione di esperimenti nella fisica delle collisioni di ioni pesanti, ed è previsto iniziare la propria attività di presa dati per LHC Run 5 nel 2032. Sono stati presi in considerazione 22 campioni di LGAD, di cui 11 provenienti dal wafer di produzione 5 (spessore 25 um) e gli altri 11 dal wafer 6 (spessore 35 um). In entrambi i casi, di questi 11 sensori, 6 sono campioni in configurazione LGAD-PIN e 5 sono matrici. Tutti e 22 i campioni sono stati sottoposti a misure di corrente in funzione del voltaggio, mentre solo quelli appartenenti al wafer 5 anche a misure di capacità. L'obiettivo è quello di misurare la caratteristica IV e CV per ognuno dei campioni e da queste estrarre, rispettivamente, tensione di breakdown e profilo di doping.
Resumo:
According to the SM, while Lepton Flavour Violation is allowed in the neutral sector, Charged Lepton Flavour Violation (CLFV) processes are forbidden. The Mu2e Experiment at Fermilab will search for the CLFV process of neutrinoless conversion of a muon into an electron within the field of an Al nucleus. The Mu2e detectors and its state-of-the-art superconducting magnetic system are presented, with special focus put to the electromagnetic crystal calorimeter. The calorimeter is composed by two annular disks, each one hosting pure CsI crystals read-out by custom silicon photomultipliers (SiPMs). The SiPMs are amplified by custom electronics (FEE) and are glued to copper holders in group of 2 SiPMs and 2 FEE boards thus forming a crystal Readout Unit. These Readout Units are being tested at the Quality Control (QC) Station, whose design, realization and operations are presented in this work. The QC Station allows to determine the gain, the response and the photon detection efficiency of each unit and to evaluate the dependence of these parameters from the supply voltage and temperature. The station is powered by two remotely-controlled power supplies and monitored thanks to a Slow Control system which is also illustrated in this work. In this thesis, we also demonstrated that the calorimeter can perform its own measurement of the Mu2e normalization factor, i.e. the counting of the 1.8 MeV photon line produced in nuclear muon captures. A specific calorimeter sub-system called CAPHRI, composed by four LYSO crystals with SiPM readout, has been designed and tested. We simulated the capability of this system on performing this task showing that it can get a faster and more reliable measurement of the muon capture rates with respect to the current Mu2e detector dedicated to this measurement. The characterization of energy resolution and response uniformity of the four procured LYSO crystals are llustrated.
Resumo:
The GRAIN detector is part of the SAND Near Detector of the DUNE neutrino experiment. A new imaging technique involving the collection of the scintillation light will be used in order to reconstruct images of particle tracks in the GRAIN detector. Silicon photomultiplier (SiPM) matrices will be used as photosensors for collecting the scintillation light emitted at 127 nm by liquid argon. The readout of SiPM matrices inside the liquid argon requires the use of a multi-channel mixed-signal ASIC, while the back-end electronics will be implemented in FPGAs outside the cryogenic environment. The ALCOR (A Low-power Circuit for Optical sensor Readout) ASIC, developed by Torino division of INFN, is under study, since it is optimized to readout SiPMs at cryogenic temperatures. I took part in the realization of a demonstrator of the imaging system, which consists of a SiPM matrix connected to a custom circuit board, on which an ALCOR ASIC is mounted. The board communicates with an FPGA. The first step of the present project that I have accomplished was the development of an emulator for the ALCOR ASIC. This emulator allowed me to verify the correct functioning of the initial firmware before the real ASIC itself was available. I programmed the emulator using VHDL and I also developed test benches in order to test its correct working. Furthermore, I developed portions of the DAQ software, which I used for the acquisition of data and the slow control of the ASICs. In addition, I made some parts of the DAQ firmware for the FPGAs. Finally, I tested the complete SiPMs readout system at both room and cryogenic temperature in order to ensure its full functionality.
Resumo:
Rapidity-odd directed flow (v1) measurements for charged pions, protons, and antiprotons near midrapidity (y=0) are reported in sNN=7.7, 11.5, 19.6, 27, 39, 62.4, and 200 GeV Au+Au collisions as recorded by the STAR detector at the Relativistic Heavy Ion Collider. At intermediate impact parameters, the proton and net-proton slope parameter dv1/dy|y=0 shows a minimum between 11.5 and 19.6 GeV. In addition, the net-proton dv1/dy|y=0 changes sign twice between 7.7 and 39 GeV. The proton and net-proton results qualitatively resemble predictions of a hydrodynamic model with a first-order phase transition from hadronic matter to deconfined matter, and differ from hadronic transport calculations.
Resumo:
Thoracic injuries in general are of great importance due to their high incidence and high mortality. Thoracic impalement injuries are rare but severe due to the combination of cause, effect and result. This study's primary objective is to report the case of a young man who was impaled by a two-wheeled horse carriage shaft while crashing his motorcycle in a rural zone. An EMT-B ferry was called at the crash scene and a conscious patient was found, sustaining a severe impalement injury to the left hemithorax, suspended over the floor by the axial skeleton with the carriage shaft coming across his left chest. As a secondary objective, a literature review of thoracic impalement injuries is performed. Cases of thoracic impalement injury require unique and individualized care based on injury severity and affected organs. Reported protocols for managing impalement injuries are entirely anecdotal, with no uniformity on impaled patient's approach and management. In penetrating trauma, it is essential not to remove the impaled object, so that possible vascular lesions remain buffered by the object, avoiding major bleeding and exsanguination haemorrhage. Severed impaled thoracic patients should be transferred to a specialist centre for trauma care, as these lesions typically require complex multidisciplinary treatment. High-energy thoracic impalement injuries are rare and hold a high mortality rate, due to the complexity of trauma and associated injuries such as thoracic wall and lung lesions. Modern medicine still seems limited in cases of such seriousness, not always with satisfactory results.
Resumo:
Bacterial strains and metagenomic clones, both obtained from petroleum reservoirs, were evaluated for petroleum degradation abilities either individually or in pools using seawater microcosms for 21 days. Gas Chromatography-Flame Ionization Detector (GC-FID) and Gas Chromatography-Mass Spectrometry (GC-MS) analyses were carried out to evaluate crude oil degradation. The results showed that metagenomic clones 1A and 2B were able to biodegrade n-alkanes (C14 to C33) and isoprenoids (phytane and pristane), with rates ranging from 31% to 47%, respectively. The bacteria Dietzia maris CBMAI 705 and Micrococcus sp. CBMAI 636 showed higher rates reaching 99% after 21 days. The metagenomic clone pool biodegraded these compounds at rates ranging from 11% to 45%. Regarding aromatic compound biodegradation, metagenomic clones 2B and 10A were able to biodegrade up to 94% of phenanthrene and methylphenanthrenes (3-MP, 2-MP, 9-MP and 1-MP) with rates ranging from 55% to 70% after 21 days, while the bacteria Dietzia maris CBMAI 705 and Micrococcus sp. CBMAI 636 were able to biodegrade 63% and up to 99% of phenanthrene, respectively, and methylphenanthrenes (3-MP, 2-MP, 9-MP and 1-MP) with rates ranging from 23% to 99% after 21 days. In this work, isolated strains as well as metagenomic clones were capable of degrading several petroleum compounds, revealing an innovative strategy and a great potential for further biotechnological and bioremediation applications.
Resumo:
In this work, the energy response functions of a CdTe detector were obtained by Monte Carlo (MC) simulation in the energy range from 5 to 160keV, using the PENELOPE code. In the response calculations the carrier transport features and the detector resolution were included. The computed energy response function was validated through comparison with experimental results obtained with (241)Am and (152)Eu sources. In order to investigate the influence of the correction by the detector response at diagnostic energy range, x-ray spectra were measured using a CdTe detector (model XR-100T, Amptek), and then corrected by the energy response of the detector using the stripping procedure. Results showed that the CdTe exhibits good energy response at low energies (below 40keV), showing only small distortions on the measured spectra. For energies below about 80keV, the contribution of the escape of Cd- and Te-K x-rays produce significant distortions on the measured x-ray spectra. For higher energies, the most important correction is the detector efficiency and the carrier trapping effects. The results showed that, after correction by the energy response, the measured spectra are in good agreement with those provided by a theoretical model of the literature. Finally, our results showed that the detailed knowledge of the response function and a proper correction procedure are fundamental for achieving more accurate spectra from which quality parameters (i.e., half-value layer and homogeneity coefficient) can be determined.
Resumo:
The aim of this study was to estimate barite mortar attenuation curves using X-ray spectra weighted by a workload distribution. A semi-empirical model was used for the evaluation of transmission properties of this material. Since ambient dose equivalent, H(⁎)(10), is the radiation quantity adopted by IAEA for dose assessment, the variation of the H(⁎)(10) as a function of barite mortar thickness was calculated using primary experimental spectra. A CdTe detector was used for the measurement of these spectra. The resulting spectra were adopted for estimating the optimized thickness of protective barrier needed for shielding an area in an X-ray imaging facility.
Resumo:
Primary X-ray spectra were measured in the range of 80-150kV in order to validate a computer program based on a semiempirical model. The ratio between the characteristic and total air Kerma was considered to compare computed results and experimental data. Results show that the experimental spectra have higher first HVL and mean energy than the calculated ones. The ratios between the characteristic and total air Kerma for calculated spectra are in good agreement with experimental results for all filtrations used.
Resumo:
The application of sand filters in localized irrigation systems is recommended in the presence of organic and algae contamination. The proper design and maintenance of these equipments are essential to assure an effective water quality control, in order to reduce the emitters clogging, to keep its water application uniformity, and to prevent increasing in the system operation costs. Despite the existence of some references about design, operation and maintenance of these filters, they are dispersed, with not enough details to guarantee the optimization of its hydraulics structure design and the proper selection of porous media to be used. Therefore, the objective of this work was to report a current literature review, relating practical information with scientific knowledge. The content of this review would help to induce and intensify the research on this subject and to contribute so the operational functions for the equipment are reached. It is also expected to assist the improvement of the filtration and flushing processes in the agricultural irrigation and the development of original design procedures and the rational use of these devices.