970 resultados para Collage indirect


Relevância:

10.00% 10.00%

Publicador:

Resumo:

An indirect ELISA for determination of post-vaccination rabies antibody was applied. Purified rabies virus was used as antigen to coat plates, and staphylococcal protein A linked with horseradish peroxidase was used for detecting IgG antibody in human sera. Sera from humans, vaccinated with cell-culture vaccine or suckling-mouse-brain vaccine, were examined. ELISA results were compared to those obtained from the virus neutralization test. The mean and standard deviation of OD were determined for 126 negative sera (pre-vaccination) and for 73 sera from vaccinated persons showing antibody titers lower than 0.5 IU/ml. Results were defined as ELISA -positive, -negative or -doubtful. Establishment of a doubtful region reduced the number of sera otherwise classified as positive (false-positive sera). In this way, the sensitivity, specificity and agreement values were respectively 87.5%, 92.4% and 88.5%. No significant differences were observed in these values when the group vaccinated with cell-culture vaccine and the group vaccinated with suckling-mouse-brain vaccine were compared. It was shown that much of the disagreement between the values obtained by neutralization test and ELISA occurred in sera obtained at the beginning of the immunization process, and was probably due to the presence of IgM in the serum samples, detected only by the former test. This ELISA method can be used as a screening test in rabies laboratories regardless of the kind of vaccine used for immunization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The occurrence of Toxoplasma antibodies in domestic outpatient cats in the city of São Paulo was evaluated using the indirect immunofluorescence assay. A total of 248 blood samples obtained from male and female cats seen at the Veterinary Teaching Hospital at the University of São Paulo between February 1996 and January 1997 were tested. Of these, 17.7% were positive, with a 64 titer being detected in most animals. The frequence of Toxoplasma antibodies was significantly higher in older cats, those fed raw meat and those with free access to the outdoor environment. There was no significant difference in reactivity between males and females. We conclude that diet and free access to the outdoor environment were equally important as predisposing factors to the risk of Toxoplasma infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Parasitological and immunological diagnoses were part of a study conducted among 151 children, 83 immunocompromised (IC) and 68 non-immunocompromised (non-IC) aged from zero to 12, seen at the University Hospital, Universidade Federal de Uberlândia, State of Minas Gerais, Brazil, from February, 1996, to June, 1998. Three fecal samples from each child were analyzed for the parasitological diagnosis by Baermann-Moraes and Lutz methods. The immunological diagnosis to detect IgG and IgM antibodies was carried out by the indirect immunofluorescence antibody test (IFAT) with cryo-microtome sections of Strongyloides stercoralis and Strongyloides ratti larvae as antigens and by the ELISA test with an alkaline extract of S. ratti as the antigens. Of the 151 children 5 (3.31%) were infected with larvae of S. stercoralis (2 cases IC, 2.41%, and 3 cases non-IC, 4.41%). The IFAT-IgG detected 7 (8.43%) serum samples positive among IC, and 2 (2.94%) cases among non-IC. The ELISA-IgG test detected 10 (12.05%) serum samples positive among IC, and 1 (1.47%) case among non-IC. The IFAT-IgM detected 6 (7.22%) positive cases among IC, and 3 (4.41%) cases among non-IC. ELISA-IgM test detected 10 (12.05%) positive cases among IC, and 3 (4.41%) cases among non-IC. It was concluded that the immunological tests can help in the diagnosis of strongyloidiasis in immunocompromised children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors report the isolation of dengue 3 virus for the first time in Brazil. The patient, resident in Limeira-SP, traveled to Nicaragua on May 16th, 1998, where he stayed for two months. Starting on August 14th he had fever, headache, myalgia, arthralgia, retro-orbital pain and diarrhea. He returned to Brazil on August 16th and was hospitalized in the next day. The patient had full recovery and was discharged on August 20th. The virus was isolated in C6/36 cell culture inoculated with serum collected on the 6th day after the onset of the symptoms. The serotype 3 was identified by indirect immunofluorescence assays performed with type-specific monoclonal antibodies. This serotype was further confirmed by polymerase chain reaction analysis. The introduction of a new dengue serotype in a susceptible population is a real threat for the occurrence of severe forms of the disease. The isolation and identification of dengue virus are important in order to monitoring the serotypes circulating in Brazil and to take the measures necessary to prevent and control an epidemic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dogs sera samples collected from Cotia County, São Paulo were tested using indirect immunoenzymatic test (ELISA) in order to study Lyme disease serology in dogs. ELISA method was standardized and G39/40 North American strain of Borrelia burgdorferi was used as antigen. Positive results were confirmed employing the Western blotting technique. Because of the possibility of cross-reactions, sera were also tested for different serological strains of Leptospira interrogans and L. biflexa using microscopic sera agglutination test. Twenty-three of 237 (9.7%) serum samples were positive in the ELISA; 20 of them (86.9%) were confirmed by the Western blotting, what suggests that Cotia may be a risk area for Lyme disease. Although 4 samples (1.7%) were positive for Lyme disease and leptospirosis, no correlation was found between the results (X² = 0.725; p = 0.394) what suggests absence of serological cross reactivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to study B. henselae transmission among cats, five young cats were kept in confinement for two years, one of them being inoculated by SC route with B. henselae (10(5) UFC). Only occasional contact among cats occurred but the presence of fleas was observed in all animals throughout the period. Blood culture for isolation of bacteria, PCR-HSP and FTSZ (gender specific), and BH-PCR (species-specific), as well as indirect immunofluorescence method for anti-B. henselae antibodies were performed to confirm the infection of the inoculated cat as well as the other naive cats. Considering the inoculated animal, B. henselae was first isolated by blood culture two months after inoculation, bacteremia last for four months, the specific antibodies being detected by IFI during the entire period. All contacting animals presented with bacteremia 6 months after experimental inoculation but IFI did not detect seroconversion in these animals. All the isolates from these cats were characterized as Bartonella (HSP and FTSZ-PCR), henselae (BH-PCR). However, DNA of B. henselae could not be amplified directly from peripheral blood by the PCR protocols used. Isolation of bacteria by blood culture was the most efficient method to diagnose infection compared to PCR or IFI. The role of fleas in the epidemiology of B. henselae infection in cats is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Serum samples (n: 110) from blood donors and high risk individuals from Cordoba, Argentina with indeterminate HIV-1 and HTLV-I/II Wb profiles were studied for specific antibodies to HTLV-I/II and HIV-1 by indirect immunofluorescence assay (IFA) and for the presence or absence of HIV-1 and HTLV-I/II specific bands by Wb. This study was carried out in order to characterize their putative reactions with HIV-1 and HTLV-I/II proteins and to resolve the retrovirus infection status of these individuals. Results indicated that blood donors sera displaying indeterminate HIV-1 or HTLV-I/II Wb patterns were not immunoreactive to HTLV-I/II and HIV-1 on IFA. However, a high rate of indeterminate HIV-1 and HTLV-I/II Wb samples from high risk individuals had positive HTLV-I/II and HIV-1 IFA results respectively. Our study supports the growing evidence that HTLV-HIV indeterminate seroreactivity in low risk population is due to a cross reaction against nonviral antigens, and in high risk populations the indeterminate samples show serological cross-recognition between HIV-1 proteins and HTLV-I/II proteins on Wb. These results point out the necessity to investigate the HTLV-I/II reactivity in indeterminate HIV-1 samples and viceversa in order to confirm the diagnosis. Finally, this study shows the potential usefulness of IFA in elucidating the status of HIV-1 and HTLV-I/II infection of individuals with indeterminate Wb profiles, thus enabling resolution of retrovirus infection status.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this article is to present an investigation of cure rate, after long follow up, of specific chemotherapy with benznidazole in patients with both acute and chronic Chagas disease, applying quantitative conventional serological tests as the base of the criterion of cure. Twenty one patients with the acute form and 113 with one or other of the various chronic clinical forms of the disease were evaluated, after a follow up period of 13 to 21 years, for the acute, and 6 to 18 years, for the chronic patients. The duration of the acute as well as the chronic disease, a condition which influences the results of the treatment, was determined. The therapeutic schedule was presented, with emphasis on the correlation between adverse reactions and the total dose of 18 grams, approximately, as well as taking into consideration precautions to assure the safety of the treatment. Quantitative serological reactions consisting of complement fixation, indirect immunofluorescence, indirect hemagglutination, and, occasionally, ELISA, were used. Cure was found in 76 per cent of the acute patients but only in 8 per cent of those with chronic forms of the disease. In the light of such contrasting results, fundamentals of the etiological therapy of Chagas disease were discussed, like the criterion of cure, the pathogenesis and the role of immunosuppression showing tissue parasitism in long standing chronic disease, in support of the concept that post-therapeutic consistently positive serological reactions mean the presence of the parasite in the patient's tissues. In relation to the life-cycle of T. cruzi in vertebrate host, there are still some obscure and controversial points, though there is no proof of the existence of resistant or latent forms. However, the finding over the last 15 years, that immunosuppression brings about the reappearance of acute disease in long stand chronic patients justifies a revision of the matter. Facts were quoted in favor of the treatment of chronic patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current article reports the case of a 19-month-old-girl, from the state of Minas Gerais, Brazil, with visceral leishmaniasis, by Leishmania (Viannia) braziliensis, and Human Immunodeficiency Virus (HIV) co-infection. The child's mother and father, aged 22 and 27 years old, respectively, were both HIV positive. The child was admitted to the General Pediatric Center, in Belo Horizonte, presenting high fever, fatigue, weight loss and enlargement of liver and spleen. Indirect immunofluorescent test revealed a titer of 1:320 for Leishmania. Such result was confirmed by the presence of amastigotes in bone marrow aspirate samples and culture of promastigote forms. Parasites were identified as being Leishmania (Viannia) braziliensis through PCR, using a L. braziliensis complex primer and a generic primer, followed by hibridization. Specific leishmaniasis therapy (GlucantimeÒ antimonial) was intravenously administered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new conglomerate family sample of 194 dwellings with 996 resident persons were studied in the town of Barcelos, State of Amazonas, in order to re-evaluate the risk of Chagas disease. During the survey the persons were interviewed and in this occasion we showed to them a collection of Panstrongylus, Rhodnius and Triatoma, asking if they recognized and eventually have been bitten by this kind of bugs. At this time we collected 500 ul of blood in microtainer® tubes from 886 interviewed persons who gave permission after informed consent. A screening test for T. cruzi antibodies based on agglutination of colored polymer particles, sensitized with three different synthetic peptides of T. cruzi (ID-PaGIA Chagas Test)®, showed 13.2% of sera positivity, but only 6.8% were confirmed by indirect immunofluorescence, and ELISA with purified T. cruzi antigens. Two hundred and six interviewed persons (20.7%) recognized the triatomines, as "piaçavas' lice" and 62 (30%) confirmed that have been bitten by the bugs, 25.8% of them had a positive serology for T. cruzi infection. Electrocardiographic alterations were shown in 9.3% of the seropositives and in 11.9% of the seronegative cases. This was considered not statistically significant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ammonia is an important gas in many power plants and industrial processes so its detection is of extreme importance in environmental monitoring and process control due to its high toxicity. Ammonia’s threshold limit is 25 ppm and the exposure time limit is 8 h, however exposure to 35 ppm is only secure for 10 min. In this work a brief introduction to ammonia aspects are presented, like its physical and chemical properties, the dangers in its manipulation, its ways of production and its sources. The application areas in which ammonia gas detection is important and needed are also referred: environmental gas analysis (e.g. intense farming), automotive-, chemical- and medical industries. In order to monitor ammonia gas in these different areas there are some requirements that must be attended. These requirements determine the choice of sensor and, therefore, several types of sensors with different characteristics were developed, like metal oxides, surface acoustic wave-, catalytic-, and optical sensors, indirect gas analyzers, and conducting polymers. All the sensors types are described, but more attention will be given to polyaniline (PANI), particularly to its characteristics, syntheses, chemical doping processes, deposition methods, transduction modes, and its adhesion to inorganic materials. Besides this, short descriptions of PANI nanostructures, the use of electrospinning in the formation of nanofibers/microfibers, and graphene and its characteristics are included. The created sensor is an instrument that tries to achieve a goal of the medical community in the control of the breath’s ammonia levels being an easy and non-invasive method for diagnostic of kidney malfunction and/or gastric ulcers. For that the device should be capable to detect different levels of ammonia gas concentrations. So, in the present work an ammonia gas sensor was developed using a conductive polymer composite which was immobilized on a carbon transducer surface. The experiments were targeted to ammonia measurements at ppb level. Ammonia gas measurements were carried out in the concentration range from 1 ppb to 500 ppb. A commercial substrate was used; screen-printed carbon electrodes. After adequate surface pre-treatment of the substrate, its electrodes were covered by a nanofibrous polymeric composite. The conducting polyaniline doped with sulfuric acid (H2SO4) was blended with reduced graphene oxide (RGO) obtained by wet chemical synthesis. This composite formed the basis for the formation of nanofibers by electrospinning. Nanofibers will increase the sensitivity of the sensing material. The electrospun PANI-RGO fibers were placed on the substrate and then dried at ambient temperature. Amperometric measurements were performed at different ammonia gas concentrations (1 to 500 ppb). The I-V characteristics were registered and some interfering gases were studied (NO2, ethanol, and acetone). The gas samples were prepared in a custom setup and were diluted with dry nitrogen gas. Electrospun nanofibers of PANI-RGO composite demonstrated an enhancement in NH3 gas detection when comparing with only electrospun PANI nanofibers. Was visible higher range of resistance at concentrations from 1 to 500 ppb. It was also observed that the sensor had stable, reproducible and recoverable properties. Moreover, it had better response and recovery times. The new sensing material of the developed sensor demonstrated to be a good candidate for ammonia gas determination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Serological survey was performed to detect IgG antibodies anti-Taenia solium metacestodes in blood donors of Hemocentro Regional de Uberlândia, Minas Gerais, Brazil. A total of 1133 sera from blood donors coming from four cities of Triângulo Mineiro area were analyzed by the indirect fluorescence antibody test (IFAT) and the enzyme linked immunosorbent assay (ELISA). Specific IgG antibodies were found in 5.6% of the studied population, showing differences in the positive rates according to their origin: Araguari (13.5%), Tupaciguara (5.0%), Monte Alegre de Minas (4.8%) and Uberlândia (4.7%). The results indicate the probable endemicity of cysticercosis in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A monitorização da qualidade da energia eléctrica tem revelado importância crescente na gestão e caracterização da rede eléctrica. Estudos revelam que os custos directos relacionados com perda de qualidade da energia eléctrica podem representar cerca de 1,5 % do PIB nacional. Para além destes, tem-se adicionalmente os custos indirectos o que se traduz num problema que necessita de minimização. No contexto da minimização dos danos causados pela degradação de energia, são utilizados equipamentos com capacidade de caracterizar a energia eléctrica através da sua monitorização. A utilização destes equipamentos têm subjacente normas de qualidade de energia, que impõem requisitos mínimos de modo a enquadrar e classificar eventos ocorridos na rede eléctrica. Deste modo obtêm-se dados coerentes provenientes de diferentes equipamentos. A monitorização dos parâmetros associados à energia eléctrica é frequentemente realizada através da instalação temporária dos esquipamentos na rede eléctrica, o que resulta numa observação de distúrbios a posteriori da sua ocasião. Esta metodologia não permite detectar o evento eléctrico original mas, quando muito, outros que se espera que sejam semelhantes ao ocorrido. Repare-se, no entanto, que existe um conjunto alargado de eventos que não são repetitivos, constituindo assim uma limitação aquela metodologia. Este trabalho descreve uma alternativa à metodologia de utilização tradicional dos equipamentos. A solução consiste em realizar um analisador de energia que faça parte integrante da instalação e permita a monitorização contínua da rede eléctrica. Este equipamento deve ter um custo suficientemente baixo para que seja justificável nesta utilização alternativa. O analisador de qualidade de energia a desenvolver tem por base o circuito integrado ADE7880, que permite obter um conjunto de parâmetros da qualidade de energia eléctrica de acordo com as normas de energia IEC 61000-4-30 e IEC 61000-4-7. Este analisador permite a recolha contínua de dados específicos da rede eléctrica, e que posteriormente serão armazenados e colocados à disposição do utilizador. Deste modo os dados recolhidos serão apresentados ao utilizador para consulta, de maneira a verificar, de modo continuo a eventual ocorrência das anomalias na rede. Os valores adquiridos podem ainda ser reutilizados vantajosamente para muitas outras finalidades tais como efectuar estudos sobre a optimização energética. O trabalho presentemente desenvolvido decorre de uma utilização alternativa do dispositivo WeSense Energy1 desenvolvido pela equipa da Evoleo Technologies. A presente vertente permite obter parâmetros determinados pelo ADE7880 tais como por exemplo harmónicos, eventos transitórios de tensão e corrente e o desfasamento entre fases, realizando assim uma nova versão do dispositivo, o WeSense Energy2. Adicionalmente este trabalho inclui a visualização remota dos através de uma página web.